Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Report on High Energy Arcing Fault Experiments: Experimental Results from Open Box Enclosures

This report documents an experimental program designed to investigate High Energy Arcing Fault (HEAF) phenomena. The experiments focus on providing data to better characterize the arc to improve the prediction of arc energy emitted during a HEAF event. An open box experiment allow for direct observation of the arc, which allows diagnostic instrumentation to record the phenomenological data needed for better characterization of the arc energy source term. The data collected supports characterization of the arc and arc jet, enclosure breach, material loss, and electrical properties. These results will be used to better characterizing the hazard for improvements in fire probabilistic risk assessment (PRA) realism. The experiments were performed at KEMA Labs located in Chalfont, Pennsylvania. The experimental design, setup, and execution were completed by staff from the NRC, the National Institute of Standards and Technology (NIST), Sandia National Laboratories (SNL) and KEMA Labs. In addition, representatives from the Electric Power Research Institute (EPRI) observed some of the experimental setup and execution. The HEAF experiments were performed between August 22, 2020 and September 18, 2020 on near-identical 51 cm (20 in) cube metal boxes suspended from a Unistrut support structure. The three-phase arcing fault was initiated at the ends of the conductors oriented vertically and located at the center of the box. Either aluminum or copper conductors were used for the conductors. The low-voltage experiments used 1 000 volts AC, while the medium-voltage experiments used 6 900 volts AC consistent with other recently completed experiments. Durations of the experiment ranged from 1 s to 5 s with fault currents ranging from 1 kA to 30 kA. Real-time electrical operating conditions, including voltage, current and frequency, were measured during the experiments. Heat fluxes and incident energies were measured with plate thermometers, radiometers, and slug calorimeters at various locations around the electrical enclosures. The experiments were documented with normal and high-speed videography, infrared imaging and photography.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Global Seismic Nowcasting With Shannon Information Entropy

Abstract Seismic nowcasting uses counts of small earthquakes as proxy data to estimate the current dynamical state of an earthquake fault system . The result is an earthquake potential score that characterizes the current state of progress of a defined geographic region through its nominal earthquake “cycle.” The count of small earthquakes since the last large earthquake is the natural time that has elapsed since the last large earthquake (Varotsos et al., 2006, https://doi.org/10.1103/PhysRevE.74.021123 ). In addition to natural time, earthquake sequences can also be analyzed using Shannon information entropy (“information”), an idea that was pioneered by Shannon (1948, https://doi.org/10.1002/j.1538‐7305.1948.tb01338.x ). As a first step to add seismic information entropy into the nowcasting method, we incorporate magnitude information into the natural time counts by using event self‐information. We find in this first application of seismic information entropy that the earthquake potential score values are similar to the values using only natural time. However, other characteristics of earthquake sequences, including the interevent time intervals, or the departure of higher magnitude events from the magnitude‐frequency scaling line, may contain additional information.

79 ASTRONOMY AND ASTROPHYSICS↗

Cooling-induced reactivation of distant faults during long-term geothermal energy production in hot sedimentary aquifers

Deep geothermal energy (DGE) represents an opportunity for a sustainable and carbon-free energy supply. One of the main concerns of DGE is induced seismicity that may produce damaging earthquakes, challenging its widespread exploitation. It is widely believed that the seismicity risk can be controlled by using doublet systems circulating water to minimize the injection-induced pressure changes. However, cold water reinjection may also give rise to thermal stresses within and beyond the cooled region, whose potential impacts on fault reactivation are less well understood. Here, we investigate by coupled thermo-hydro-mechanical modeling the processes that may lead to fault reactivation in a hot sedimentary aquifer (HSA) in which water is circulated through a doublet. We show that thermal stresses are transmitted much ahead of the cooled region and are likely to destabilize faults located far away from the doublet. Meanwhile, the fault permeability mainly controls the fault reactivation timing, which entails the importance of employing appropriate characterization methods. This investigation is crucial for understanding the mechanisms controlling induced seismicity associated with DGE in a HSA and allows the success of future DGE projects.

15 GEOTHERMAL ENERGY↗

High contrast imaging and thickness determination of graphene with in-column secondary electron microscopy

We report a new method for quantitative estimation of graphene layer thicknesses using high contrast imaging of graphene films on insulating substrates with a scanning electron microscope. By detecting the attenuation of secondary electrons emitted from the substrate with an in-column low-energy electron detector, we have achieved very high thickness-dependent contrast that allows quantitative estimation of thickness up to several graphene layers. The nanometer scale spatial resolution of the electron micrographs also allows a simple structural characterization scheme for graphene, which has been applied to identify faults, wrinkles, voids, and patches of multilayer growth in large-area chemical vapor deposited graphene. We have discussed the factors, such as differential surface charging and electron beam induced current, that affect the contrast of graphene images in detail.

36 MATERIALS SCIENCE↗

Growth of very large InN microcrystals by molecular beam epitaxy using epitaxial lateral overgrowth

Very thick InN (∼40 μm) was grown by molecular beam epitaxy using the epitaxial lateral overgrowth (ELO) technique. In some regions, the ELO of InN was observed as expected, indicating an important step toward fabricating quasi-bulk InN substrates. Interestingly, most parts of the sample consist of large flat-topped microcrystals and well-faceted microstructures. This is likely due to local growth condition variations during ELO, which is supported by an experiment where ELO of InN was performed on a substrate with various stripe mask patterns. TEM characterization of a flat top InN microcrystal revealed few stacking faults and only related threading dislocations. Defect-free small faceted microcrystals were also observed. The thick InN crystals show a narrow photoluminescence spectrum with a peak at 0.679 eV and linewidth of 16.8 meV at 4 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SECARB Design Specifications for Seismic Survey (SECARB Phase III Work Product 4.2.2.a)

A test site and anthropogenic CO 2 source have been selected for a large-scale demonstration of carbon dioxide separation, capture and sequestration in southwestern Alabama as part of the Southeastern Regional Carbon Sequestration Partnership’s (SECARB) Phase III initiative. The James M. Barry Generating Plant, a major coal-fired power plant in southwestern Alabama, is the selected anthropogenic CO 2 source for the project. The proposed storage test site is located in the Southeast Unit of the Citronelle oil field, which lies at the crest of the Citronelle Dome about 10 miles to the west of the power plant. The proposed storage site appears to be suitable for deep underground injection of CO 2 . An evaluation of the storage capacity and geological integrity of the proposed injection and confining intervals is a critical step in the assessment of the test site. This evaluation is important for several reasons, including project planning, permitting of injection wells, and the design and execution of injection and monitoring operations. Accordingly, the Geological Survey of Alabama (GSA) will conduct a detailed geological evaluation of the Southeast Citronelle Unit that emphasizes the acquisition, interpretation, and analysis of seismic reflection data. The goals of this work are to characterize the geologic structure of the area, verify that no faults are present, determine and analyze the seismic expression of sandstone and shale bodies in the Paluxy target interval, and to assist in the Underground Injection Control (UIC) permitting process.

01 COAL, LIGNITE, AND PEAT↗

On-line diagnosis of sequential systems, 3

A formal model is introduced which can serve as the basis for a theoretical investigation of on-line diagnosis. Within this model a fault of a system S is considered to be a transformation of S into another system S prime at some time tau. The resulting faulty system is taken to be the system which looks like S up to time tau and like S prime thereafter. The on-line diagnosis of systems which are structurally decomposed and represented as a network of smaller systems is also investigated. The fault set considered is the set of unrestricted component faults; namely, the set of faults which only affect one component of the network. A characterization of networks which can be diagnosed using a combinational detector is obtained. It is further shown that any network can be made diagnosable in the above sense through the addition of one component. In addition, a lower bound is obtained on the complexity of any component, the addition of which is sufficient to make a particular network combinationally diagnosable.

Sundstrom, R. J.↗

Diagnosis without repair for hybrid fault situations

In the present paper, the concept of a hybrid fault situation is introduced, which specifies bounded combinations of permanently faulty and intermittently faulty units in a system. The general class of hybrid fault situations includes, as special cases, the all permanent fault case and the unrestricted intermittent fault case, which have been previously considered with PMC models. An approach compatible with the diagnosis of permanent fault situations is then applied to the diagnosis of hybrid fault situation. The motivation for doing so is the common practice of testing for the presence of intermittent faults in systems by means of repeated applications of tests that are designed for the detection of permanent faults. The testing assignment of PMC models of system is characterized, and interrelationships between the number of intermittently and permanently faulty units that can be diagnosed is established.

Mallela, S.↗

Design of the hybrid automated reliability predictor

The design of the Hybrid Automated Reliability Predictor (HARP), now under development at Duke University, is presented. The HARP approach to reliability prediction is characterized by a decomposition of the overall model into fault-occurrence and fault-handling sub-models. The fault-occurrence model is a non-homogeneous Markov chain which is solved analytically, while the fault-handling model is a Petri Net which is simulated. HARP provides automated analysis of sensitivity to uncertainties in the input parameters and in the initial state specifications. It then produces a predicted reliability band as a function of mission time, as well as estimates of the improvement (narrowing of the band) to be gained by a specified amount of reduction in uncertainty.

Geist, R.↗

General Purpose Data-Driven Online System Health Monitoring with Applications to Space Operations

Modern space transportation and ground support system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional parameter limit checking, or model-based or rule-based methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults, failures, or precursors of significant failures. The Inductive Monitoring System (IMS) is a general purpose, data-driven system health monitoring software tool that has been successfully applied to several aerospace applications and is under evaluation for anomaly detection in vehicle and ground equipment for next generation launch systems. After an introduction to IMS application development, we discuss these NASA online monitoring applications, including the integration of IMS with complementary model-based and rule-based methods. Although the examples presented in this paper are from space operations applications, IMS is a general-purpose health-monitoring tool that is also applicable to power generation and transmission system monitoring.

Iverson, David L.↗

Quantitative Measures for Software Independent Verification and Validation

As software is maintained or reused, it undergoes an evolution which tends to increase the overall complexity of the code. To understand the effects of this, we brought in statistics experts and leading researchers in software complexity, reliability, and their interrelationships. These experts' project has resulted in our ability to statistically correlate specific code complexity attributes, in orthogonal domains, to errors found over time in the HAL/S flight software which flies in the Space Shuttle. Although only a prototype-tools experiment, the result of this research appears to be extendable to all other NASA software, given appropriate data similar to that logged for the Shuttle onboard software. Our research has demonstrated that a more complete domain coverage can be mathematically demonstrated with the approach we have applied, thereby ensuring full insight into the cause-and-effects relationship between the complexity of a software system and the fault density of that system. By applying the operational profile we can characterize the dynamic effects of software path complexity under this same approach We now have the ability to measure specific attributes which have been statistically demonstrated to correlate to increased error probability, and to know which actions to take, for each complexity domain. Shuttle software verifiers can now monitor the changes in the software complexity, assess the added or decreased risk of software faults in modified code, and determine necessary corrections. The reports, tool documentation, user's guides, and new approach that have resulted from this research effort represent advances in the state of the art of software quality and reliability assurance. Details describing how to apply this technique to other NASA code are contained in this document.

Lee, Alice↗

Above zone pressure interpretation for leaky well characterization and its identification from leaky caprock/fault

Pressure transient analysis has long been used for reservoir characterization. Above-zone (AZ) pressure has been recently investigated for inferring leakage pathway characteristics in leakage events from subsurface injection operations. The recorded pressure in the AZ should be purely related to leakage and therefore it can be safely inverted to deduce leakage characteristics. It is crucial to evaluate fluid leakage through abandoned wells to plan for further measurements of leakage prevention. However, the recorded AZ leakage signal may not be related to leaky well(s). Therefore, identification and spatial investigation of well leakage is required for leakage evaluation. Here in this paper, we propose a pressure interpretation method for early detection of leaky pathways, applying two observation points in the AZ. We distinguish leaky well, fault and caprock based on their corresponding flow regime identification. We show that the pressure difference of the two observation wells can be applied as a proxy for unknown leakage rate, which is crucial for leakage identification as well as characterization. Results show that the estimated location of the leaky well, leakage coefficient, and the leakage rate are in good agreement with the actual values. The estimated leakage coefficient of the leaky well can be used to evaluate well leakage in multiphase systems such as carbon dioxide leakage in deep saline aquifers.

02 PETROLEUM↗

Geology of Biblis Patera, Ulysses Patera, and Jovis Tholus, Mars

There are a variety of constructional volcanic features in Tharsis. These features range from Olympus Mons and the Tharsis Montes shields, to the small low shields and fissure eruptions that characterize much of the volcanic plains, to the smaller volcanic constructs in the northeast and western parts of Tharsis. I describe the geology of the western group, which includes Biblis Patera, Ulysses Patera, and Jovis Tholus. Each of these volcanoes has had a unique, and complex geologic history. Biblis Patera is located at 2.3 deg. N, 123.8 deg. The volcano is elongate in a northwesterly direction and has a large, faulted caldera complex. The flanks of the volcano and adjacent plains are characterized by lava flows, northwest-trending graben and troughs, and caldera-concentric graben and troughs. Biblis Patera is approximately 66 x 127 km with an oval 51 x 56 km caldera; the summit elevation is approximately 2 km above the surrounding plains. The constrcut has an estimated volume of 8-22 x 10(exp 3) cu km. Ulysses Patera is located at 2.7 deg. N, 121.3 deg. W and stands approx. 2-3 km above the surrounding plain; flank slopes are approximately 7 deg. to 12 deg. The caldera floor is quite deep, lying 1.8 to 2.2 km below the caldera rim. The caldera has a void volume of approximately 5000 cu km, the total solid mass volume of the volcano is 7-16 x 10(exp 3) cu km. Jovis Tholus is centered at 18.3 deg N; 117.5 deg W; it is a low relief, volcano with gentle flank slopes of between 3 and 8 deg. The construct is dominated by a series of inset calderas which make up the largest fraction of the area. The caldera complex is offset to the southwest side. Total shield dimensions are approximately 77 km (e-wt) by 62 km (n-s); the caldera complex is approximately 44 x 34 km. The shield is embayed on all sides by younger Amazonian age volcanics. Total relief, relative to the surrounding plains, is probably approximately 2 km. The total volume of Jovis Tholus is estimated to be approximately 2-5 x 10(exp 3) cu km.

Plescia, J. B.↗

Model-based sensor location selection for helicopter gearbox monitoring

A new methodology is introduced to quantify the significance of accelerometer locations for fault diagnosis of helicopter gearboxes. The basis for this methodology is an influence model which represents the effect of various component faults on accelerometer readings. Based on this model, a set of selection indices are defined to characterize the diagnosability of each component, the coverage of each accelerometer, and the relative redundancy between the accelerometers. The effectiveness of these indices is evaluated experimentally by measurement-fault data obtained from an OH-58A main rotor gearbox. These data are used to obtain a ranking of individual accelerometers according to their significance in diagnosis. Comparison between the experimentally obtained rankings and those obtained from the selection indices indicates that the proposed methodology offers a systematic means for accelerometer location selection.

Jammu, Vinay B.↗

Southeast Regional Carbon Sequestration Partnership (SECARB) Collect Repeat 3-D Survey

The baseline 3-D survey of Cranfield was collected by Denbury Onshore LLC. in 2007 and data provided to the SECARB Early team at the BEG as a major cost share contribution for Phase II. The baseline 3-D survey covered the entire Cranfield Field as well into the surrounding brine-saturated water leg. This data remains extremely valuable in characterization for Phase III, and has been analyzed extensively. Bureau researchers Hongliu Zeng and Tip Meckel have analyzed the baseline 3-D to develop reservoir models. For example, Zeng enhanced seismic data to extract textures suggestive of high sinuosity aggradational point bar from the lower Tuscaloosa interval. Meckel assessed the logs and seismically imaged structure to better define the oil-water contact to assure that the DAS experiment was set in the water leg, and mapped the graben-edge fault that separates the Phase II and the Phase III areas. Additional characterization work continues by a number of students under funding from SECARB (Kordi dissertation) as well as additional efforts under BES funding though the CFSES project.

01 COAL, LIGNITE, AND PEAT↗

In situ observations on the coupling between hydraulic diffusivity and displacements during fault reactivation in shales

Key questions in fault reactivation in shales relate to the potential for enhanced fluid transport through previously low-permeability aseismic formations. Here, we explore the behavior of a 20 m long N0-to-170°, 75-to-80°W fault in shales that is critically stressed under a strike-slip regime (σ 1 = 4 ± 2 MPa, horizontal and N162° ± 15°E, σ 2 = 3.8 ± 0.4 MPa and σ 3 = 2.1 ± 1 MPa, respectively 7-8° inclined from vertical and horizontal and N72°). The fault was reactivated by fluid pressurization in a borehole using a straddle packer system isolating a 2.4 m long injection chamber oriented-subnormal to the fault surface at a depth of 250 m. A three-dimensional displacement sensor attached across the fault allowed monitoring fault movements, injection pressure and flow rate. Pressurization induced a hydraulic diffusivity increase from ~2 × 10 -9 to ~10 3 m 2 s -1 associated with a complex three-dimensional fault movement. The shear (x-, z-) and fault-normal (y-) components (U x , U y , and U z ) = (44.0 × 10 -6 m, 10.5 × 10 -6 m, and 20.0 × 10 -6 m) are characterized by much larger shear displacements than the normal opening. Numerical analyses of the experiment show that the fault permeability evolution is controlled by the fault reactivation in shear related to Coulomb failure. The large additional fault hydraulic aperture for fluid flow is not reflected in the total normal displacement that showed a small partly contractile component. This suggests that complex dilatant effects estimated to occur in a plurimeter radius around the injection source affect the flow and slipping patch geometries during fault rupture, controlling the initial slow slip and the strong back slip of the fault following depressurization.

58 GEOSCIENCES↗

Active tectonics in southern Xinjiang, China: Analysis of terrace riser and normal fault scarp degradation along the Hotan-Qira fault system

The northern piedmont of the western Kunlun mountains (Xinjiang, China) is marked at its easternmost extremity, south of the Hotan-Qira oases, by a set of normal faults trending N50E for nearly 70 km. Conspicuous on Landsat and SPOT images, these faults follow the southeastern border of a deep flexural basin and may be related to the subsidence of the Tarim platform loaded by the western Kunlun northward overthrust. The Hotan-Qira normal fault system vertically offsets the piedmont slope by 70 m. Highest fault scarps reach 20 m and often display evidence for recent reactivations about 2 m high. Successive stream entrenchments in uplifted footwallls have formed inset terraces. We have leveled topographic profiles across fault scarps and transverse abandoned terrace risers. The state of degradation of each terrace edge has been characterized by a degradation coefficient tau, derived by comparison with analytical erosion models. Edges of highest abandoned terraces yield a degradation coefficient of 33 +/- 4 sq.m. Profiles of cumulative fault scarps have been analyzed in a similar way using synthetic profiles generated with a simple incremental fault scarp model.

Avouac, Jean-Philippe↗

Characterization and Comparison of Vibration Transfer Paths in a Helicopter Gearbox and a Fixture Mounted Gearbox

Health monitoring of rotorcraft components, currently being performed by Health and Usage Monitoring Systems through analyses of vibration signatures of dynamic mechanical components, is very important for their safe and economic operation. HUMS analyze vibration signatures associated with faults and quantify them as condition indicators to predict component behavior. Vibration transfer paths are characterized by frequency response functions derived from the input/output relationship between applied force and dynamic response through a structure as a function of frequency. With an objective to investigate the differences in transfer paths, transfer path measurements were recorded under similar conditions in the left and right nose gearboxes of an AH-64 helicopter and in an isolated left nose gearbox in a test fixture at NASA Glenn Research Center. The test fixture enabled the application of measured torques-common during an actual operation. An impact hammer as well as commercial and lab piezo shakers, were used in conjunction with two types of commercially available accelerometers to collect the vibration response under various test conditions. The frequency response functions measured under comparable conditions of both systems were found to be consistent. Measurements made on the fixture indicated certain real-world installation and maintenance issues, such as sensor alignments, accelerometer locations and installation torques, had minimal effect. However, gear vibration transfer path dynamics appeared to be somewhat dependent on the presence of oil, and the transfer path dynamics were notably different if the force input was on the internal ring gear rather than on the external gearbox case.

structures↗