Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fiber laser”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Picosecond Synchronization System for Quantum Networks

The operation of long-distance quantum networks requires photons to be synchronized and must account for length variations of quantum channels. We demonstrate a 200 MHz clock-rate fiber optic-based telecommunication C-band quantum network using off-the-shelf components combined with custom-made electronics. The network is backed by a scalable and fully automated synchronization system with ps-scale timing resolution. Synchronization of the photons is achieved by distributing O-band-wavelength laser pulses between network nodes. Specifically, we distribute photon pairs between three nodes, and measure a reduction of coincidence-to-accidental ratio from 77 to only 42 when the synchronization system is enabled, which permits high-fidelity qubit transmission. Our demonstration sheds light on the role of noise in quantum communication and represents a key step in realizing deployed co-existing classical-quantum networks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical simulation of dispersion and nonlinear characteristics of microstructured silica fibres with a thin suspended core in a wide range of their parameters

Dispersion and nonlinear characteristics of microstructured silica fibres with a thin suspended core surrounded by three, four or six air holes have been studied theoretically in the wavelength range 1 – 2 μm. It has been shown that, owing to strong fundamental mode confinement near the core, the Kerr nonlinearity coefficient can exceed the nonlinearity coefficient of standard telecom fibre SMF28e by two orders of magnitude. The large waveguide contribution allows for effective group velocity dispersion management. Estimates are presented that demonstrate the feasibility of using suspended core fibre exhibiting Kerr nonlinearity for generating non-classical light: a state with squeezed quantum fluctuations in one of the quadrature components of a cw laser signal at a wavelength near 1.55 μm. (paper)

36 MATERIALS SCIENCE↗

Spatially Resolved Raman Spectroscopy of Thin Carbon Interphase in SiC Ceramic Matrix Composites

A dedicated analysis method is presented to extract the Raman spectrum of an interphase layer thinner than the laser spot size. We focused on spatial correlations between the contrast of optical micrographs and Raman hyperspectral data to predict the constituents of the mixed spectra measured near the interphase. By employing a mapping step size of 0.1 μm, the Raman spectrum of approximately 0.3-μm-thick carbon interphase in a SiC fiber-reinforced SiC matrix composite was extracted from data acquired with a theoretical spot size of about 0.7 μm. Notably, conventional chemometrics procedures were unable to isolate the interphase signal, instead producing a spectrum representing a mixture of interphase and matrix. This study used another composite with approximately 0.9-μm-thick interphase to validate the analysis method, enabling direct measurement of the interphase spectrum. The proposed Raman analysis method has advantages in specimen volume and turnaround time compared to traditional characterization methods, such as transmission electron microscopy. In conclusion, this study also evaluates the applicability of the analysis method to different composite materials and identifies key requirements of the measurements, including the ratio of interphase thickness to spot size and the homogeneity of the surrounding matrix.

ceramic matrix composite↗

Concept for an irradiation experiment to test a laser-induced breakdown spectroscopy off-gas sensor for molten salt systems

This paper focuses on laser-induced breakdown spectroscopy (LIBS) as an off-gas sensor and details a conceptual irradiation experiment to evaluate its performance in an environment that is more realistic of an operational molten salt reactor (MSR). MSRs are a promising advanced nuclear design that use high-temperature liquid salts as the coolant, fuel, or a combination of both. They will generate and subsequently evolve fission products into the reactor headspace during operation. These evolved fission products will necessitate an online off-gas system to treat the reactor cover gas before recycling it to the core. Such a system, especially during the early deployment phase, will benefit from online sensors to inform operators of the treatment system’s performance. Optical spectroscopy is well-suited to fit this task as it can be remotely deployed using fiber-optics and can detect most species at high frequencies. LIBS can detect nearly every element on the Periodic Table, stable or radioactive, making it an ideal candidate. The provided conceptual experiment discusses the facility requirements, salt capsule design, and detailed testing campaigns with corresponding simulated LIBS spectra.

47 OTHER INSTRUMENTATION↗

Acoustic mapping by picosecond ultrasonics for elastic property measurement: Experimental demonstration on a TRISO fuel compact

Picosecond ultrasonics has been demonstrated on a tristructural isotropic (TRISO) fuel compact to measure the elastic properties of each compact layer. This technique utilizes an ultrashort pump laser pulse to excite vibrations in a gold transducer film covering the surface of each component and a second probe laser pulse to record the resulting acoustic strain induced change in optical reflectance. From the damping of this film vibration, the acoustic reflection coefficient, which couples the elastic properties of the transducer film and the sample, can be obtained, enabling a calculation of the sample’s acoustic velocity and elastic modulus. Overall, results obtained from this method are consistent with known values of elastic moduli, namely that the SiC coating is the stiffest component of the compact while the carbonaceous matrix is the most compliant. Nanoindentation was conducted as a benchmark technique on the same sample and shows satisfactory agreement with the results of picosecond ultrasonics. Compared to other methods like nanoindentation, picosecond ultrasonics is multimodal with a capability of measuring several key properties simultaneously and has potentials to be coupled into optical fibers for remote sensing. Thus, these demonstration measurements reveal the methodology to be a promising candidate for in-situ and high-throughput optical characterizations of nuclear materials.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Detailed Characterization of Vitrinite-Rich Subbituminous and Bituminous Coals for Utilization in Carbon Fiber Precursor Production

Chemical structures of candidate coals (one subbituminous coal from the Powder River Basin and three bituminous Eastern US coals) were examined for potential low-cost carbon fiber precursor production. Here, the structural evaluation examined the carbon skeleton ( 13 C nuclear magnetic resonance (NMR) and high-resolution transmission electron microscopy (HRTEM)), the heteroatom functionality (X-ray photoelectron spectroscopy (XPS) Fourier transform infrared spectroscopy (FTIR) and NMR), the structural ordering and distribution of PAH sizes (HRTEM), and an estimation of the molecular weight distribution (laser desorption ionization mass spectrometry, LDIMS). The molecular compositional distributions were also evaluated for a mixed solvent extract (atmospheric pressure photoionization, 21 T Fourier transform ion cyclotron resonance mass spectrometry, FT-ICR MS). Significant structural differences existed between the subbituminous and bituminous coals, as expected with coalification (with the bituminous coals having a higher carbon content, lower oxygen content, higher aromaticity values, larger cluster sizes, and so forth). While the bituminous coals were similar in structure (close in rank with Blue Gem being hvAb and the rest being hvBb), structural differences were still evident. Specifically, structural similarities were evident for the average properties of Herrin and Springfield coals: same rank, similar moisture, and volatile matter yields, along with similar aromaticity and carbon and hydrogen content. However, significant structural differences were observed at the molecular level by 21 T FT-ICR MS, which showed that the Springfield coal was structurally more complex. Specifically, 21740, 16931, 30190, and 12982 unique elemental compositions were identified for the Monarch, Herrin, Springfield, and Blue Gem coals, further illustrating the complexity of the coal.

01 COAL, LIGNITE, AND PEAT↗

Fiber optic system for direct detection of CO 2 leakage in carbon storage wells (Abbreviated Final Report)

The feasibility study focused on the development of new fiber for distributed chemical sensing that will allow direct detection of CO2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CSS), which can provide early warning for an incoming well failure and potential CO2 leaking through it. We proposed Raman or IR interrogation within gas-filled Holey Fibers (HoFs) interleaved with Fiber Bragg Grating (FBG) sections, so that the location and concentration of the gases would be provided simultaneously. The methodology would overcome current roadblocks to using fiber optics for CO2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure. We were able to assess commercially available IR/Raman hollow core fiber and demonstrated detection of CO2 through them in our controlled environment setups at various pressure conditions. We have also established the ability of drilling precisely with fs-lases side holes to enable penetration of CO2 into the hollow core fiber and reduce diffusion rates. Open joint collars were also explored with double functionality: to obtain splice to solid core fiber critical for field deployment and create gas ingress locations. Both diffusion-only and pressurized fiber system have been constructed following COMSOL based semi-hybrid optical /fluidodynamics models. FBGs have been identified and procured and characterized. Along the work we leveraged internal modeling/design, photonics/laser characterization, optical fiber fabrication, and AM lab capabilities to design, develop and test in-house components or assemblies. Our results indicate the potential of HoF for CO2 downhole direct detection.

25 ENERGY STORAGE↗

Fiber-Coupled Multipass NIR Sensor for In Situ, Real-Time Water Vapor Outgassing Monitoring

This work presents the recent development of a fiber-coupled multipass near-infrared (NIR) gas sensor used to monitor water vapor desorption of small material coupons. The gas sensor design employs a White cell topology to maximize the optical path length over a compact, hand-size footprint. Water vapor concentrations are quantified over a large dynamic range by simultaneously applying wavelength modulation and tunable diode laser absorption spectroscopy techniques. A custom headspace optimized for material desorption experiments is assembled using commercially available vacuum chamber components. We provide in situ measurements of water vapor desorption from two geometries of the industrially important silicone elastomer Sylgard-184 as a case study for sensor viability. To corroborate the results, the gas sensor data are compared to numerical simulations based on a triple-mode diffusion–sorption model, consisting of Henry, Langmuir, and Pooling modes.

gas sensor↗

Influence of defect characteristics on tensile deformation of an additively manufactured stainless steel: Evolutions of texture and intergranular strain

The micromechanics of plastic deformation behavior of a selective laser melt processed austenitic stainless steel were studied by investigating the evolutions of texture and intergranular strain using in situ high-energy synchrotron x-ray diffraction (sXRD). The effects of defect characteristics on tensile behavior were studied using three different samples: a near full-density sample with elliptical closed voids and two samples with lack-of-fusion (LOF) defects tensile loaded either perpendicular or parallel to their major axes. The evolutions of pole figures and inverse pole figures show that the full-density specimen develops a strong (111)/(200) fiber texture along the loading direction. For both LOF specimens, the evolution of texture is qualitatively similar to the full-density counterpart, but the development of the fiber texture was much slower, indicating a limited plasticity at a given macroscopic strain. The intergranular strain evolution in the full-density specimen is similar to that of a wrought 316L stainless steel. Conversely, a significantly different intergranular strain development was observed in a LOF specimen, where tensile strain development was observed in both the axial and transverse directions. Finally, the influence of defect type, density, and orientation on the local stress states in the steel matrix and the evolutions of intergranular strains is discussed.

36 MATERIALS SCIENCE↗

Super-resolution demodulation for fiber sensor arrays based on the MUSIC algorithm

This paper studies the use of MUltiple SIgnal Classification (MUSIC) as a super-resolution algorithm to improve demodulation results for intrinsic Fabry–Perot interferometer (IFPI) sensor arrays. Through distinction between noise and signal subspaces in an observation matrix, this paper shows that a 38-fold improvement in the full width at half maximum (FWHM) estimation of IFPI optical path differences (OPD) can be achieved using this algorithm. Based on this improved method, this paper demonstrates that a tunable laser with a 1.3-nm tuning range can achieve the same sensor demodulation performance as a tunable laser with a 50-nm tuning range if a conventional Fourier transform-based algorithm is used. This paper presents a new approach to analyzing optical signals produced by multiple multiplexed interferometers with similar OPDs with potential applications for both single-mode and multiple-mode devices.

Li, Yuqi (ORCID:0000000291643663)↗

A structural analysis of ordered Cs3Sb films grown on single crystal graphene and silicon carbide substrates

Alkali antimonides are well established as high efficiency, low intrinsic emittance photocathodes for accelerators and photon detectors. However, conventionally grown alkali antimonide films are polycrystalline with surface disorder and roughness that can limit achievable beam brightness. Ordering the crystalline structure of alkali antimonides has the potential to deliver higher brightness electron beams by reducing surface disorder and enabling the engineering of material properties at the level of atomic layers. In this report, we demonstrate the growth of ordered Cs3Sb films on single crystal substrates 3C-SiC and graphene-coated 4H-SiC using pulsed laser deposition and conventional thermal evaporation growth techniques. The crystalline structures of the Cs3Sb films were examined using reflection high energy electron diffraction and x-ray diffraction diagnostics, while film thickness and roughness estimates were made using x-ray reflectivity. With these tools, we observed ordered domains in less than 10 nm thick films with quantum efficiencies greater than 1% at 530 nm. Moreover, we identify structural features such as Laue oscillations indicative of highly ordered films. We found that Cs3Sb films grew with flat, fiber-textured surfaces on 3C-SiC and with multiple ordered domains and sub-nanometer surface roughness on graphene-coated 4H-SiC under our growth conditions. We identify the crystallographic orientations of Cs3Sb grown on graphene-coated 4H-SiC substrates and discuss the significance of examining the crystal structure of these films for growing epitaxial heterostructures in future experiments.

36 MATERIALS SCIENCE↗

Demonstrate the Out-of-Pile Performance of a Real-Time Measurement System to Measure Thermal Conductivity Based on Photo Thermal Radiometry

SUMMARY The goal of this project is to develop a fiber-based instrument to perform in-reactor thermal conductivity measurements of fuels and materials. This instrument is based on photothermal radiometry (PTR) and involves heating a sample locally and measuring the induced temperature gradient by collecting blackbody radiation [2]. Thermal conductivity of the sample is extracted by comparing experimental results with a continuum-based model [3,4]. As a laser-based technique, PTR is a non-contact measurement technique that can be performed remotely and non-destructively. In addition, it has several advantages over other photothermal techniques, making it an ideal approach for in-situ measurement of thermal conductivity of nuclear fuels. Because blackbody radiation increases with emissivity and temperature, the PTR technique works well with unprepared surfaces, and measurement accuracy increases with temperature. Moreover, this approach is capable of measuring samples with irregular or poorly defined boundary conditions, which is a common situation for friable spent fuels.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detecting Phase-Resolved Magnetization Dynamics by Magneto-Optic Effects at 1550 nm Wavelength

We demonstrate the detection of phase-resolved magnetization dynamics with combinatorial magneto-optic Kerr and Faraday effects. The method uses a continuous-wave laser that is amplitude-modulated at the spin dynamic frequencies, and thus allows for coherent tracking of the spin dynamics, akin a “lock-in” type measurement. In particular, our method, using a single 1550-nmwavelength, probes simultaneously the ferromagnetic resonance of Y 3 Fe 5 O 12 (YIG) and Permalloy (Py = Ni 80 Fe 20 ) in a YIG-Pyhetero structure. The fiber-based magneto-optic components also have the advantage of being made into a compact, tabletop or even portable system with yet robust measurement performances. We believe that our method will be found useful in studying hybrid quantum magnonic systems and/or investigating phase-resolved spin dynamics in nanomagnet structures involving both ferromagnetic insulators and metals.

42 ENGINEERING↗

Control Design for Inhomogeneous-Broadening Compensation in Single-Photon Transducers

We report a transducer of single photons between microwave and optical frequencies can be used to realize quantum communication over optical fiber links between distant superconducting quantum computers. A promising scalable approach to constructing such a transducer is to use ensembles of quantum emitters interacting simultaneously with electromagnetic fields at optical and microwave frequencies. However, inhomogeneous broadening in the transition frequencies of the emitters can be detrimental to this collective action. In this paper, we utilize a gradient-based optimization strategy to design the temporal shape of the laser field driving the transduction system to mitigate the effects of inhomogeneous broadening. We study the improvement of transduction efficiencies as a function of inhomogeneous broadening in different single-emitter cooperativity regimes and correlate it with a restoration of super-radiance effects in the emitter ensembles. Furthermore, to assess the optimality of our pulse designs, we provide certifiable bounds on the design problem and compare them to the achieved performance.

74 ATOMIC AND MOLECULAR PHYSICS↗

Table-Top High Photon Energy Sources for Chemical Dynamics Investigations

Time-resolved spectroscopies using high-energy photons in the vacuum ultraviolet (VUV) to the X-ray region of the electromagnetic spectrum, have proven to be powerful probes of chemical dynamics. These high-energy photons can access valence and core orbitals of molecules and materials, providing key information on molecular and electronic structure and their time evolution. This report details the development of table-top sources of extreme ultraviolet (XUV) and VUV pulses at Sandia National Laboratories for use in studies of gas phase chemical dynamics. Femtosecond duration XUV pulses are produced using laser-driven high harmonic generation and their detected range span ~40-140 eV photon energies. These pulses are used in conjunction with ultraviolet pulses in a pump-probe scheme to study excited state dynamics of gas phase molecules. VUV pulses at 7.75 eV are generated using a four-wave-mixing scheme driven by 800 nm and 266 nm pulses in an argon-filled hollow-core fiber.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of a fiber-coupled x-ray diffraction detector for dynamic compression experiments

The long-term x-ray diffraction (XRD) detector scheme compatible with Z-containment experiments will involve conversion of the diffracted x-rays to optical light, which will be transported away from the Z-Dynamic Materials Properties (DMP) load and detected on a fast-gated camera. In this so-called DIffraction SCintillator Optic (DISCO) scheme , the scintillator is coupled to a long, coherent imaging fiber bundle using a custom lens system with high numerical aperture. In addition, the DISCO diagnostic incorporates time-gating to allow measurement only during the short time window of the x-ray pulse in which XRD occurs, thereby significantly reducing unwanted background generated by the Z-DMP load. Dynamic compression experiments were performed at the Chama target chamber to evaluate the DISCO diagnostic . Specifically, a Zr sample was laser-shocked with the Chaco laser while the Z-Beamlet (ZBL) laser was used to generate x-rays, which enabled time-gated 6.7-keV XRD patterns from the compressed Zr sample to be obtained.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility of using distributed chemical sensing for CO2 leakage monitoring

The feasibility study focused on the development of new fiber for distributed chemical sensing (DCS) that will allow direct detection of CO 2 leakages in the environment. This is particularly important for monitoring well integrity for carbon capture and storage (CCS), to provide early warning for an incoming well failure and potential CO 2 leaking through it. We proposed using optical spectroscopy in optical fiber for direct detection of CO 2 . The main approach is based on Raman interrogation within gas-filled Holey Fibers (HoFs), so that the location and concentration of the gases would be provided simultaneously via backscattering. Additionally, Infrared (IR) Absorption Spectroscopy could also be used, and the architecture would be more discrete since interleaving with standard solid core fibers and Fiber Bragg Grating (FBG) sections is required to enable reflection to the I/O controls. The possible Raman length or the IR numbers of sections would be defined based on signal to noise ratio. The optical spectroscopy methodology would overcome current roadblocks to CCS, as fiber optics will allow for CO 2 (and other gases) detection in wells with direct in-situ measurements of concentration along with other important parameters such as temperature and pressure as the baseline of environment background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗