Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Oxidation of Superalloys in Extreme Environments

Superalloys like 718 and its derivatives primarily rely on the formation of an external Cr-rich oxide layer or scale for environmental protection at high temperatures. Operating conditions where environmental resistance is more of a concern generally involve higher temperatures or more corrosive environments, especially where S is present, usually due to fuel impurities. With clean fuels, the presence of water vapor and oxygen, such as a combustion environment in a natural gas-fired turbine, chromia forms a volatile oxy-hydroxide leading to accelerated Cr loss. In laboratory experiments, mass losses are measured due to this volatilization. For sulfidizing or hot corrosion environments, the role of alloy and coating composition on corrosion resistance will be reviewed. An increasing area of interest is the interaction between environmental degradation and the stress-induced deformation of the superalloy including the influence of oxidation-resistant coatings on mechanical properties. Strategies to study this interaction will be discussed.

36 MATERIALS SCIENCE↗

NaOH-assisted direct reduction of Ring of Fire chromite ores, and the associated implications for processing

As part of a broader programme to fully characterize the chromite ores discovered in the 'Ring of Fire' region of northern Ontario, NRCan and private research facilities in Canada have performed extensive test work over the past six years. The studies focused on developing alternative approaches for producing ferrochrome at lower temperatures and with fewer greenhouse gas emissions. The use of various fluxes or catalysts for accelerated direct reduction had yielded promising results, particularly with caustic soda (NaOH). Here, the initial work had been protected by a patent known as the 'KWG process'. The most recent work by NRCan has confirmed that the addition of NaOH to chromite ores in carefully controlled amounts leads to high degrees of metallization at much lower temperatures than would be achieved by conventional smelting technologies, at greatly accelerated reactions rates.

58 GEOSCIENCES↗

DEVELOPMENT OF A CERAMIC TAMPER INDICATING SEAL: SRNL CONTRIBUTIONS

Savannah River National Laboratory (SRNL) and Sandia National Laboratories (SNL) are collaborating on development of a Ceramic Seal, also sometimes designated the Intrinsically Tamper Indicating Ceramic Seal (ITICS), which is a tamper indicating seal for international safeguards applications. The Ceramic Seal is designed to be a replacement for metal loop seals that are currently used by the IAEA and other safeguards organizations. The Ceramic Seal has numerous features that enhance the security of the seal, including a frangible ceramic body, protective and tamper indicating coatings, an intrinsic unique identifier using Laser Surface Authentication, electronics incorporated into the seal that provide cryptographic seal authentication, and user-friendly seal wire capture. A second generation prototype of the seal is currently under development whose seal body is of Low Temperature Co-fired Ceramic (LTCC) construction. SRNL has developed the mechanical design of the seal in an iterative process incorporating comments from the SNL vulnerability review team. SRNL is developing fluorescent tamper indicating coatings, with recent development focusing on optimizing the durability of the coatings and working with a vendor to develop a method to apply coatings on a 3-D surface. SRNL performed a study on the effects of radiation on the electronics of the seal and possible radiation shielding techniques to minimize the effects. SRNL is also investigating implementation of Laser Surface Authentication (LSA) as a means of unique identification of each seal and the effects of the surface coatings on the LSA signature.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Trial by Fire? Rulewriters, Training, the BLM, and EPA

Individual bureaucrats are ultimately tasked with solving complex problems and are expected to do so cost-effectively. The purpose of this paper is to examine an infrequent perspective of administrative rulemaking - training. Simply put, our goal is to examine original interview data with federal rulewriters in two agencies - the Environmental Protection Agency and the Bureau of Land Management to understand how bureaucrats are trained to carry out rules. This exploratory study suggests the importance of training for the next generation of rulewriters. In particular, we demonstrate existing informal training can be effective, but more mechanisms (e.g. formal training and mentoring) is necessary.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Boride Based Electrode Materials with Enhanced Stability Under Extreme Conditions for MHD Direct Power Extraction. Final Scientific Report

Coal power currently makes up almost 40% of global electricity production. This method of extracting energy from coal can be added to any coal plant, improving its energy output. Not only would this prepare us to keep up with the ever-increasing energy demands but it could also allow us to significantly cut the greenhouse gas emissions for the coal power industry. Hafnium diboride (HfB 2 ), Zirconium diboride (ZrB 2 ), and their solid solution mixtures were studied, primarily for electrode coating applications in coal-fired magnetohydrodynamic (MHD) direct power extraction plants. MHD works by directly extracting current from superheated plasma flame (2725 °C) seeded with potassium salts. Obviously, the electrodes near this flame are subject to extreme temperatures and corrosive environments. The coating material needs to protect the electrodes from salt corrosion, oxidation, and melting, while still providing electrical conductivity. Transition metal diborides have many of the desired properties but need improvement for oxidation resistance above 1200 °C. Two main methods of oxidation resistance improvements were investigated during this research. The first was through electrochemical anodization, a process where a thin protective oxide layer is grown on the surface to prevent further detrimental oxidation at high temperatures. Several solutions, voltages, and methods were used to find an oxide layer that would protect at high temperatures. The second method was to use various additives and mixture ratios to improve densification and oxidation resistance. Ratios of HfB 2 and ZrB 2 tested were 1:4, 1:1, 4:1 and 1:1 with additives of Ta, Hf, and Zr metals, bringing the boron to metal ratio down to 1.86. Additionally, 1.8 mol% Gd 2 O 3 and LaB 6 were added to the 1:1 ratio HfB 2 -ZrB 2 . Hydrogen evolution reaction kinetics were also investigated to shed some light on the ability of these materials to resist corrosion. Aqueous corrosion tests were also performed in several solutions of different pH. The 1:1 ratio solution added with LaB 6 gave the best overall results both in high temperature and room temperature aqueous experiments. Further work will be needed to evaluate the efficacy of these materials for such applications.

01 COAL, LIGNITE, AND PEAT↗

Handling and Treatment of Sodium-Potassium Alloy (NaK) after the Loss of Key Personnel – 19002

ABSTRACT In September 2010, during cleanup and removal efforts associated with a glovebox containing a sodium-potassium alloy (NaK) cooling system, a NaK reaction event occurred. Near the end of the evolution, which was at a Materials and Fuels Complex (MFC) research facility at the Idaho National Laboratory, a 2 to 3-ounce sample of NaK was being transferred from a metal can to a polyethylene bottle so it could be sent to the disposal outlet for verification analysis. During the transfer, a reaction of the NaK with ambient air was observed in both the metal can and sample container. The potential for a reaction was identified during the planning of this activity and mitigating steps were included in the procedures. In response, the two containers were flooded with argon, closed, and observed overnight. No additional reaction was noted. The sample container and metal can were packaged into a 10-gallon drum and transferred to a permitted storage location pending disposal. While the other containers generated from the deactivation and decommissioning activity were sent off-site for disposal, the 10-gal drum remained due to concerns by a staff specialist that the material could contain potassium superoxide (KO2) as a result of the reaction event. The intent at that time was to treat the NaK in a Resource Conservation and Recovery Act (RCRA)-permitted treatment facility at MFC, instead of sending it off-site for disposal. The container was labeled, inspected, and managed as a hazardous waste. Due to the complexities associated with safely handling and treating NaK and KO2, the container remained in storage. Treatment and disposal of the NaK and KO2 container was revisited in 2016, when researchers and chemists were consulted regarding the potential for superoxide formation and the best means to safely store and treat the container. The facility came to realize that due to the retirements of key personnel, it needed to provide current employees operational experience with the handling and treatment of NaK. An outside company was identified and contracted to provide training and consulting services. Several Battelle Energy Alliance, Inc. (BEA) personnel then attended an alkali metals safety training class. The training course provided participants with classroom and hands–on instruction associated with: • Hazards associated with handling and using sodium and NaK • Proper personal protection equipment, spill control techniques, and first aid • Common design approaches for buildings, systems, and equipment used to contain sodium and NaK • What to expect in the event of a water reaction and how to respond • How to properly prepare for a fire and contain/extinguish small metal fires • A hands-on demonstration of NaK reaction and controls. Following the training, a procedure was developed to open the container, and inspect and treat the NaK. In June 2017, facility operations personnel successfully completed the inspection and treatment of the NaK drum, eliminating the legacy liability.

99 GENERAL AND MISCELLANEOUS↗

An Historic Perspective of NPDES Individual Permit for Storm Water Discharges from Solid Waste Management Units at Los Alamos National Laboratory - 18667

The Los Alamos National Laboratory (LANL) and the associated communities of Los Alamos and White Rock are located in Los Alamos County in north-central New Mexico approximately 60 mi north-northeast of Albuquerque and 25 mi northwest of Santa Fe. The 36-mi{sup 2} facility is situated on the Pajarito Plateau, which consists of a series of fingerlike mesas separated by deep east-to-west oriented canyons cut by predominately ephemeral and intermittent streams. The mesa tops range in elevation from approximately 7800 ft. on the flanks of the Jemez Mountains to about 6200 ft. at their eastern termination above the Rio Grande Canyon. The land surrounding the Laboratory is largely undeveloped. Public access to much of the facility is limited for safety and security reasons. Large tracts of surrounding land are held by the U.S. Forest Service (Santa Fe National Forest), the Bureau of Land Management (Bandelier National Monument), the General Services Administration and San Ildefonso Pueblo. Storm water discharges from Solid Waste Management Units (SWMUs) have been regulated at the LANL since the early 1990's and have evolved into an Individual Stormwater Permit (IP) that may be one of the most complex in the nation. Historically, storm water discharges from SWMUs at LANL were regulated under a nationwide general permit using a watershed based approach requiring a Storm Water Pollution Prevention Plan (SWPPP), monitoring at sub-watershed scale 'USGS like' gage stations, and inspection and maintenance of erosion controls. In 2001, the Cerro Grande Fire destroyed many Laboratory structures, residential homes and over 80,000 acres of forested lands in the upper watershed above Los Alamos that significantly changed the local hydrology. Several years later, a Federal Facilities Compliance Agreement (FFCA) was issued by U.S. Environmental Protection Agency (USEPA) that was followed by a Clean Water Act lawsuit filed by concerned citizens, the result of which required more focus on stormwater discharges from individual SWMUs and an IP covering over 400 Sites. The IP contains non-numeric technology-based effluent limitations, coupled with a comprehensive, coordinated inspection and monitoring program, to minimize pollutants in LANL's storm water discharges associated with historical industrial activities from specified Sites. Non-numeric technology-based effluent limitations include minimizing pollutants in discharges through erosion and sedimentation controls, management of run-on and runoff, employee training, inspection and maintenance of controls, annual reporting and public involvement. The IP establishes Target Action Levels (TALs) that are equivalent to New Mexico State water-quality criteria. These TALs are used as benchmarks to determine the effectiveness of control measures implemented under the IP. That is, storm water quality sample results from SWMU discharges are compared with applicable TALs. If one or more sample results exceed a TAL, LANL must take additional corrective action. The TAL results are also confounded by high levels of naturally occurring constituents such as aluminum and gross alpha, and urban constituents such as copper, zinc and PCBs which may not be a source from the regulated SWMU. Due to the remote rugged terrain, security access issues, number of monitoring locations, stringent TALs, reporting requirements and public involvement requirements, this permit is likely one of the most stringent and complex in the country. The Laboratory has implemented this permit in a compliant manner for the past seven years and is anticipating the issuance of a new permit in the next few months. This paper will cover permit requirements related to control measure installations, monitoring, reporting and public involvement as well as process improvements and remaining water quality initiatives such as developing studies to address issues such as discriminating between natural background levels and LANL-related contaminants during the execution of this unique permit. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High-Temperature Oxidation Behavior of Wrought and Additive Manufactured Ni-based Alloys in Direct-Fired Supercritical CO2 Power Cycle Environments

Materials selection is a key concern for corrosion resistance in elevated temperature and pressure direct-fired supercritical CO2 (sCO2) power cycles. Herein, the wrought product form of alloy H282, as well as several additional nickel-based commercial alloys (230, 263, 617, 625, 740H), were exposed to direct-fired supercritical CO2 conditions (95CO2 – 4H2O – 1O2) at 750 °C and 20 MPa for over 2,000 h. Additionally, additive manufactured (AM) 282 produced by laser powder bed fusion (LPBF) were also included in the exposures. This paper focuses primarily on the differences observed in the degradation behavior of the wrought and additively manufactured materials. AM samples in the as-printed state were found to form less protective oxide scales resulting in higher oxidation rates compared to wrought samples. However, applying a 600 grit surface finish to the AM samples modified the oxidation behavior to closely resemble that of the wrought material. The AM samples formed Mo-rich carbides in the alloy beneath the oxide following sCO2 exposure, implying potentially higher levels of carbon uptake relative to the wrought material. Conversely, the AM samples seemed to be less affected by water-assisted oxide volatilization compared to the wrought material. The results are discussed in terms of the potential compatibility issues that may arise when using Ni-based alloys in the hot portions of direct-fired sCO2 power cycles, particularly in the case of thin-walled components.

Carney, Casey↗

Remaining Sites Verification Package for the 600-111, P-11 Critical Mass Laboratory Crib, and UPR-600-16, Fire and Contamination Spread Waste Sites, Waste Site Reclassification Form 2008-045

The UPR-600-16, Fire and Contamination Spread waste site is an unplanned release that occurred on December 4, 1951, when plutonium contamination was spread by a fire that ignited inside the 120 Experimental Building. The 120 Experimental Building was a laboratory building that was constructed in 1949 and used for plutonium criticality studies as part of the P-11 Project. In November 1951, a criticality occurred in the 120 Experimental Building that resulted in extensive plutonium contamination inside the building. The confirmatory evaluation supports a reclassification of this site to Interim Closed Out. The current site conditions achieve the remedial action objectives and the corresponding remedial action goals established in the Remaining Sites ROD. The results of the extensive radiological survey of the surface soil and the confirmatory and verification sampling show that residual contaminant concentrations do not preclude any future uses and allow for unrestricted use of shallow zone soils. The results also demonstrate that residual contaminant concentrations are protective of groundwater and the Columbia River.

100-IU-6 Operable Unit↗

Quantitative Risk Assessment for Hydrogen-Powered Locomotive Refueling

Hydrogen powered locomotives are being explored to reduce emissions in rail applications. The risks of operations like refueling should be understood to ensure safe environments for workers and members of the public. Sensitivity analyses were conducted using HyRAM+ to identify major drivers of risk and compare effects of system parameters on individual risk. The consequences of jet fires from full-bore leaks dominated the risk, compared to explosions or smaller leaks. Pipe size, leak detection capability, and leak frequencies of system components greatly affected risk while overpressure modeling parameters and ambient conditions had little effect. The effects of personal protective equipment (PPE) materials on individual risk were quantified by reducing the individual’s exposure time or absorbed thermal dose. PPE only showed a risk reduction in low-risk cases. This study highlighted target areas for risk mitigation, including leak detection equipment and component maintenance, and indicated that the minimal effects of other parameters on risk may not justify prescriptive requirements for refueling operators.

08 HYDROGEN↗

Subtask 4.27 - Evaluation of the Multielement Sorbent Trap (MEST) Method at an Illinois Coal-Fired Plant

Owners of fossil fuel-fired power plants face the challenge of measuring stack emissions of trace metals and acid gases at much lower levels than in the past as a result of increasingly stringent regulations. In the United States, the current reference methods for trace metals and halogens are wet-chemistry methods, U.S. Environmental Protection Agency (EPA) Methods 29 and 26 or 26A, respectively. As a possible alternative to the EPA methods, the Energy & Environmental Research Center (EERC) has developed a novel multielement sorbent trap (MEST) method to be used to sample for trace elements and/or halogens. Sorbent traps offer a potentially advantageous alternative to the existing sampling methods, as they are simpler to use and do not require expensive, breakable glassware or handling and shipping of hazardous reagents. Field tests comparing two sorbent trap applications (MEST-H for hydrochloric acid and MEST-M for trace metals) with the reference methods were conducted at two power plant units fueled by Illinois Basin bituminous coal. For hydrochloric acid, MEST measured concentrations comparable to EPA Method 26A at two power plant units, one with and one without a wet flue gas desulfurization scrubber. MEST-H provided lower detection limits for hydrochloric acid than the reference method. Results from a dry stack unit had better comparability between methods than results from a wet stack unit. This result was attributed to the very low emissions in the latter unit, as well as the difficulty of sampling in a saturated flue gas. Based on these results, the MEST-H sorbent traps appear to be a good candidate to serve as an alternative to Method 26A (or 26). For metals, the MEST trap gave lower detection limits compared to EPA Method 29 and produced comparable data for antimony, arsenic, beryllium, cobalt, manganese, selenium, and mercury for most test runs. However, the sorbent material produced elevated blanks for cadmium, nickel, lead, and chromium at levels that would interfere with accurate measurement at U.S. hazardous air pollutant emission limits for existing coal-fired power plant units. Longer sampling times employed during this test program did appear to improve comparative results for these metals. Although the sorbent contribution to the sample was reduced through improved trap design, additional research is still needed to explore lower-background materials before the MEST-M application can be considered as a potential alternative method for all of the trace metals. This subtask was funded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FC26-08NT43291. Nonfederal funding was provided by the Electric Power Research Institute, the Illinois Clean Coal Institute, Southern Illinois Power Company, and the Center for Air Toxic Metals Affiliates Program.

Pavlish, John↗

Los Alamos National Laboratory Floodplain Assessment for the Technical Area 72 Outdoor Live Fire Range Gate Installation Project

The National Nuclear Security Administration (NNSA), a semi-autonomous agency within the U.S. Department of Energy (DOE), is proposing new construction in lower Sandia Canyon at Technical Area (TA) 72 at the Outdoor Live Fire Range facility at Los Alamos National Laboratory (LANL). The proposed upgrades are intended to improve range safety.

54 ENVIRONMENTAL SCIENCES↗

SAVY O-ring characterization for lifetime extension

Los Alamos National Laboratory and Nuclear Filter Technology, Inc. developed the SAVY-4000 nuclear material storage container, named after the designers Stone, Anderson, Viers, and Yarbro. The SAVY 4000 meets the requirements of Department of Energy (DOE) M 441.1-1,2 Nuclear Material Packaging Manual, to protect workers who handle nuclear materials against radiation exposures resulting from the leakage of stored materials. The SAVY-4000 is an innovative and creative design: it can be opened and closed in a few seconds without using torque wrenches and instead only a tire iron or equivalent prying tool; has a built-in, fire-rated filter that prevents the build-up of hydrogen gas yet retains 99.97% of plutonium particulates at 200 ACCM rated flow; and prevents the release of stored materials upon a 12- foot drop.

42 ENGINEERING↗

A trilevel model against false gas-supply information attacks in electricity systems

The interdependence between natural gas and electricity systems is increasing rapidly due to the growing reliance on natural gas-fired generating units. Availability of natural gas for gas-fired generating units can impact the secure operation of electricity systems. Fuel supply shortage for gas-fired units can be caused by uncertain interruptible supply contracts and incorrect supply information. This article proposes a trilevel min-max-min defender-attacker-operator optimization problem to provide the power system operator a screening methodology that allocates a limited budget for best protecting critical fuel supply information, and also the strategies to sign firm supply contract to reduce natural gas supply uncertainties. We utilize a column and constraint generation (C&CG) algorithm to solve the proposed problem. We illustrate the effectiveness of this trilevel formulation using a case study based on IEEE 24-node test system.

42 ENGINEERING↗

A mathematical programming approach for the optimal placement of flame detectors in petrochemical facilities

Flame detectors provide an important layer of protection for personnel in petrochemical plants, but effective placement can be challenging. A mixed-integer nonlinear programming formulation is proposed for optimal placement of flame detectors while considering non-uniform probabilities of detection failure. We show that this approach allows for the placement of fire detectors using a fixed sensor budget and outperforms models that do not account for imperfect detection. In this study, we develop a linear relaxation to the formulation and an efficient solution algorithm that achieves global optimality with reasonable computational effort. We integrate this problem formulation into the Python package, Chama, and demonstrate the effectiveness of this formulation on a small test case and on two real-world case studies using the fire and gas mapping software, Kenexis Effigy.

47 OTHER INSTRUMENTATION↗

Test and Validate Distributed Coaxial Cable Sensors for in situ Condition Monitoring of Coal-Fired Boiler Tubes

This project aims to test, validate, and advance the technology readiness level (from TRL5 to TRL7) of a novel low-cost distributed stainless-steel/ceramic coaxial cable sensing (SSC-CCS) technology for in situ monitoring of the boiler tube temperature in existing coal-fired power plants. The novel SSC-CCS sensing technology and associated condition-based monitoring (CBM) software to be demonstrated in this project will lead to an improved understanding of the boiler tube failure mechanisms and a prognostic system to improve the overall performance, reliability, and flexibility of the nation’s coal-fired power plant fleet. A boiler tube monitoring system with distributed coaxial cable temperature sensors and a sensor acquisition system was constructed. The high-temperature coaxial cable sensor with a length of 1.3m was made by using a quartz tube (1mm inner diameter (ID) and 6mm outer diameter (OD)) to concentrically separate a 304 stainless-steel (SS) rod (1mm OD) and SS tube (7.94mm OD and 6.16mm ID). The sensor acquisition system includes a vector network analyzer (VNA), a radio frequency (RF) power amplifier, multiple switches and a USB hub. The distributed stainless-steel quartz coaxial cable sensor (SSQ-CCS) had a linear response to temperature with a resolution uncertainty of σ = 0.77℃. To withstand the harsh conditions of 3,300 steam pressures and 800℃ high temperatures, the sensor was shielded by a protective tube made of the same material as the boiler tube. The protection tube had an OD of 1.5 inches and a thickness of 0.25 inches. In the laboratory tests, the sensor showed good sensitivity and fast response. The drift was bounded between +0.33% and -0.67% during a test at 600℃ for 350 hours, indicating good stability of the sensor. A field test was conducted where four sensors were welded on four superheat tubes (SH-Ts) at a coal-fired power station over 400 days. Conventional thermocouples were welded to the superheater tubes alongside the coaxial cable sensors for the purpose of comparison. Two sensors were capable of distributed sensing, with three multiplexed sensing sections. The other two sensors were single section. During the 400-day test period, the power plant experienced startups and shutdowns. At the steady state operations, the temperature of the boiler tube is about 600℃ (1112°F). The sensors recorded the entire coal-firing processes (start-up, steady state, and shut-down) and the glitch event. A GSM modem and a Watchdog were added to the system to ensure reliable data recording. The GSM modem sent daily messages to plant managers and Clemson team to inform the status of the sensor system. If the system was not normally working, the Watchdog would reboot the system automatically. The new coaxial cable based distributed sensing technology has been proven to be successful in both laboratory and field tests. A comprehensive four-stage multi-physics computational framework has been developed to assist the design, optimization, installation, and operation of SSQ-CCS. With the consideration of various operation conditions, we predict the distributions of flue gas temperatures within coal-fired boilers, the temperature correlation between the boiler tube and SSQ-CCS, and the safety of SSQ-CCS. A conditional-based monitoring system is implemented as well. The computational framework developed in this work can guide the future operation of coal-fired plants and other power plants for the safety prediction of boiler operations.

01 COAL, LIGNITE, AND PEAT↗

Biota Dose Assessment at LANL for 2011

Beginning with the Manhattan Project, the earliest work with radioactive material was located in what is now the center of Los Alamos townsite, and some of those materials were released into the environment or disposed of as waste. These radioactive materials have been extensively studied and assessed in many reports during the past 60 years. The assessments consider many activities relevant to dose assessment, such as adventurous children who burrow into and eat the soil, as well as the activities of pets and wildlife. Even for the most extreme scenarios, the doses are less than a few mrem per year, well below the DOE limit for the public, and four orders of magnitude below the DOE limit to terrestrial animals, which is 0.1 rad per day. Locations that pose even a very small risk to humans or pets are fenced, locked, and posted as controlled areas. However, it is recognized that biota such as plants, birds, mice, and worms live in these controlled areas. The DOE standard is intended to protect these biota. Contaminated sites in and near Los Alamos consist of areas known as solid waste management units (SWMU) and areas of concern (AoC) that have been identified and studied extensively in many reports. LA-UR-90-4300 lists these locations, and many subsequent reports provide extensive details and assessments. Between these areas, the levels of detectable radioactive materials are many orders of magnitude smaller. Because they are not a focus of concern, the areas outside of SWMUs and AoCs have not been as extensively studied or sampled. The highest concentrations of radioactive materials resulting from historic LANL operations are buried in material disposal areas (MDAs) such as MDA A, B, C, G, T, etc. Much of this material is sealed in containers that are not accessible to biota (McNaughton 2005). In some cases, it is buried below the reach of tree roots or burrowing animals, and in some cases it is encased or embedded in concrete. Of particular relevance to the present report, the hills to the west of LANL, where the Las Conchas fire burned, are not contaminated with LANL‐derived substances. The radioactivity in these hills consists of naturally occurring radioactive material (NORM) and global fallout.

54 ENVIRONMENTAL SCIENCES↗

Annual Report for SCC

The Advanced Combustion Project addresses fundamental issues of fire-side and steam-side corrosion and materials performance in oxy-fuel combustion environments and provides an integrated approach into understanding the environmental and mechanical behavior such that environmental degradation can be ameliorated and long-term microstructural stability, and thus mechanical performance, can lead to longer lasting components and extended power plant life.

20 FOSSIL-FUELED POWER PLANTS↗