Search NASA⌕ Search

SEARCH · Search NASA

Results for “Flow boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Boiling water reactor high flow filter system - 15683

Mechanical filtration is an essential element of industrial processes and operations. In the nuclear industry, mechanical filtration is particularly problematic because of the added challenge of minimizing personnel exposure and contamination associated with filter handling. Until recently, there has been no effective filtration system to maintain water clarity and minimize dose for diving operations in Torus/Suppression Pools, or for vacuuming operations to decontaminate Dryer Separation Pits during plant outages. To be effective, the filtration system must provide high flow to speed recovery from low visibility conditions. It must also have a high dirt loading capacity to minimize downtime during outage critical path. This paper looks at a new filtration system that has been introduced to the U.S. commercial nuclear power industry and used in numerous outages since 2012 and compares this Solids Collection Filter (SCF{sup TM}) system to previous filtration systems and practices and its impact on outage diving operations and decontamination efforts. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Summary of Recent SBIR and STTR Projects in Support of Cryogenic Fluid Management Modeling

Over the last five years, NASA has invested in development of sub-models to improve the current capabilities of Computational Fluid Dynamics (CFD) codes utilized for cryogenic fluid management (CFM) predictions. The goal is for the submodels to be modular so that they can easily be implemented into NASA’s CFD codes such as ANSYS Fluent, Siemens STAR-CCM+, and Streamline Numerics Loci-Stream. These technologies are being developed through Small Business Innovative Research (SBIR) and Small Business Technology Transfer (STTR) contracts under the CFM subtopic solicitation and funded by the CFM Portfolio Project. All contracts presented include cryogenic experiments to enable model validation. A sub-grid boiling model has been developed by Combustion Research and Flow Technology Inc. and Massachusetts Institute of Technology for cryogenic line chilldown predictions and has completed Phase III. A spray chill-and-fill model for cryogenic tankage is being developed by Combustion Research and Flow Technology Inc. and University of Connecticut and is currently in Phase II. Last, film condensation modeling to support cryogenic liquefaction was progressed through a Phase I contract with Combustion Research and Flow Technology Inc. and University of Connecticut. A summary of accomplishments for each contract is presented.

cryogenics↗

Development and Validation of a Conjugate Heat Transfer Model for the Two-Phase CFD Code NEK-2P

A project is underway to develop, verify and validate an advanced two-phase flow modeling capability for the highly-scalable, high-performance CFD code NEK5000. The goal of the project is to develop a new two-phase version of the NEK5000 code, named NEK-2P, to simulate the two-phase flow and heat transfer phenomena that occur in a Boiling Water Reactor (BWR) fuel bundle under various operating conditions. The NEK-2P two-phase flow models follow the approach used for the Extended Boiling Framework (EBF) [2-3] previously developed at Argonne, but include more fundamental physical models of boiling phenomena and advanced numerical algorithms for improved computational accuracy, robustness, and computational speed. The development of the NEK-2P two-phase solver and the implementation of the Extended Boiling Framework two-phase models were initially supported by Argonne National Laboratory (Argonne) through a Laboratory Directed Research and Development (LDRD) project during FY2014-2016. The development and validation of the two-phase models through analyses of selected two-phase boiling flow experiments was supported by the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program in FY2017-2019. This report focuses on the FY2019 development and validation of the Conjugate Heat Transfer (CHT) model for the NEK-2P Two-Phase, Computational Fluid Dynamics (CFD) code. The NEK-2P CHT model calculates the coupled behavior of the fluid and solid domains. In the fluid domain NEK-2P calculates the vapor and liquid phase temperatures, velocities and mass fractions. In the solid domain only the temperatures are calculated. The fluid and solid domains are coupled with a heat flux boundary condition at the fluid-solid interface. The heat flux and the wall temperatures at the fluid-solid interface are updated using the NEK-2P wall heat-flux partitioning model. A wall heat flux boundary condition is also applied to the exterior surface of the solid domain. The CHT model validation was illustrated through the analysis of three of the Becker Critical Heat Flux (CHF) tests. Reasonably good agreement with measured data was obtained in predicting the CHF location and post CHF wall temperature behavior illustrating the ability of the NEK-2P CHT model to simulate the CHF phenomena for a wide range of thermal-hydraulic conditions. Apart from the CHT model development and validation, initial simulations were performed for the Virginia Tech. (VT) 3x3 bare rod bundle experiments including both cold and boiling flow simulations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation of a Pressure Correction Term in the CTF Subchannel Code

CTF is a modernized and improved version of the legacy subchannel code COBRA-TF, being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 to help address CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF user group, and developing the code for use in coupled applications. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model augmented by equations for the droplet field, and it also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent effort to improve CTF capabilities for simulating flows in boiling water reactors (BWRs). The six-equation two-phase flow model is not strongly hyperbolic, meaning that some of its eigenvalues are either not real or not distinct. In a Cauchy sense, and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness, which ensures the uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations. Such terms are often referred to as virtual mass or interfacial pressure correction terms. From a mathematical perspective, this approach adds terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix, thus the imaginary part of the eigenvalues. For this work, an interfacial pressure correction (IPC) term on the same model as what was used for the CATHARE system code, is implemented in CTF. This allows for recovery of a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled, along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem at a pressure of 10 bar. Finally, conclusions and future work are addressed.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Recent progresses on thermal–hydraulics evaluations of accident tolerant fuel cladding materials

Thermal–hydraulics (T-H) experiments have been on the progress to evaluate boiling heat transfer characteristics of accident tolerant fuel (ATF) candidates for further supporting the core-loading of these advanced ATF concepts in light water reactors (LWRs). Here this study covers recent experimental studies of ATF claddings and summarizes some significant results. Recent T-H experimental results of ATF cladding candidates demonstrated that the material thermal–physical properties have pronounced effects on critical heat flux (CHF). Such effects have not been well resolved in the current physics-governing models. These effects of cladding materials on CHF could be potentially rationalized by the material-conjugated boiling heat transfer, where the material-dominated heat conduction competes with the flow boiling-dominated heat convection. As progressively increasing the mass flux and/or liquid subcooling, CHF differences between different materials gradually decrease, which is in agreement with the recent T-H experimental results of ATF claddings. This is because the dominance of heat convection over heat conduction is primarily improved by liquid subcooling and/or mass flow rate. It is noteworthy that surface oxidization of claddings may have unknown impacts on T-H performances because the formation of oxide layers on cladding surfaces introduces variations of material thermal–physical properties and then changes the surface morphological features, which results in some difficulties in evaluating the thermal safety margins of ATF claddings.

36 MATERIALS SCIENCE↗

Experimental Study for Two Phase Flow Instability in the PCHE Type Steam Generator in SMR

Conventional U-tube type heat exchangers have some limitations when applied to Small Modular Reactor (SMRs). In particular, the size of steam generators is important in the SMR, as it greatly affects the size, and thus the cost, of the reactor vessel.. Therefore, the circuit heat exchanger (PCHE) is suggested as an alternative. PCHE, a compact type heat exchanger manufactured by HEATRIC, has several advantages such as the reduced size, wide operation range until 900? and 900 bar and high power density due to the large heat transfer area over volume ratio. Recently, it is newly suggested as an application of a steam generator. MIT and KAIST have already conceptually suggested PCHE as a steam generator. Under boiling condition, flow instability is one of the critical issues-resulting in unstable mass flow rate, sudden temperature change and system control failure. According to the flow mechanism, there are various types of instabilities in the heat exchanger and each flow tendency is different. Typical examples are Ledinegg instability of the static instability and pressure-drop oscillation and density-wave oscillation of the dynamic instability. The characteristic of Ledinegg instability is that the flow under unstable condition changes into the stable flow. The characteristic of dynamic instability is that the flow fluctuates continuously. Pressure-drop oscillation has the period of tens of seconds and the system pressure also highly oscillates with the period of flow instability. In comparison, the density-wave oscillation has the period of few seconds and the system pressure is relatively stable. Previous studies on flow instability are focused on the single channel flow and helical tube type heat exchanger. There has been very limited experimental research on flow instability using PCHE. In KAIST, the test facility was constructed to study the thermal hydraulics in PCHE. The objectives of our test facility are: (1) to identify the occurrence of instability under two phase and super-heated steam flow in PCHE, and (2) to examine whether it can operate normally using throttling effect. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Numerical Predictions of the Flow and Heat Transfer Characteristics in the Film Boiling Regime During Tube Quenching

Cryogenic fluid management plays a major role in refueling of spacecrafts while in space for NASA’s future human space exploration missions. Due to the low boiling points of cryogens, storage, transport and handling of these fluids becomes difficult and may result in inefficient operation of the space propulsion systems. For refueling applications in space, the cryogenic fluids have to be transported across different locations and hence, the transfer of cryogenic fluids through pipes become critical. The cryogenic chill-down process is characterized by different regimes of flow boiling, viz., film boiling, transition boiling and nucleate boiling. The prediction of these regimes in a single CFD framework available in the literature is challenging and the present work attempts to address this challenge by initially modeling the film boiling regime accurately and to incorporate an user-defined function for transition and nucleate boiling at a later stage. Hence, the aim of the present work is to numerically model and validate the film boiling regime of the chilldown curve for liquid nitrogen experiments available in the literature. The validations are carried out at different inlet mass fluxes to have a robust simulation methodology. A dispersed mixture model is used to predict the vapor-liquid interface dynamics with the phase change phenomena modeled using the Lee model.

line chilldown↗

Transport processes in boiling and two-phase systems, including near-critical fluids

Aspects of pool boiling are considered, taking into account nucleate boiling, the nucleate boiling mechanism, film boiling, and the transition between nucleate and film boiling. The characteristics of two-phase flow are also investigated, giving attention to two-phase flow parameters and equations, the flow pattern in two-phase flow, the pressure drop in two-phase flow, heat transfer in two-phase flow, two-phase flow dynamics, the boiling crisis in two-phase flow, the critical flow rate, the propagation of the pressure pulse and the sonic velocity in two-phase media, instrumentation for two-phase flow, and geometry and field effects on boiling and two-phase flow. Near-critical fluids are also considered.

Hsu, Y.-Y.↗

Technology of forced flow and once-through boiling: A survey

Representative boiling heat transfer and pressure drop information obtained primarily from past NASA and AEC programs is presented which is applicable to forced flow and once-through boiler systems. The forced convection boiler has a number of advantages: little possibility of flow mal-distribution; heat transfer characteristics are usually consistent; and conductances are predictable, so that higher heat fluxes may be employed with safety (which leads to more compact, lighter weight equipment). It was found that in gas-fired systems particularly, the controlling heat transfer resistance may be on the hot side, so that increased fluxes would require extended surfaces. If in a power generation system the working fluid is very expensive, a forced flow boiler can be designed especially for small holdup volume. If the fluid is temperature sensitive, the boiling side wall temperatures can be tailored to maintain maximum heat transfer rates without overheating the fluid. The forced flow and once-through configurations may be the only type which can satisfy a specific need (such as the automotive Rankine cycle power plant design having a very short time-response boiler).

Poppendieck, H. F.↗

Combined buoyancy and flow direction effects on saturated boiling critical heat flux in liquid nitrogen

Buoyancy effects on the critical heat flux and general data trends for a liquid nitrogen internal flow system were determined by comparison of upflow and downflow data under identical test conditions. The test section had a 1.28 cm diameter flow passage and a 30.5 cm heated length which was subjected to uniform heat fluxes through resistance heating. Test conditions covered a range of pressures from 3.4 to 10.2 atm, inlet velocities from 0.23 to 3.51 m/sec, with the liquid nitrogen temperature at saturated inlet conditions. Data comparisons showed that the critical heat flux for downflow could be up to 36 percent lower than for upflow. A nonmonotonic relationship between the critical heat flux and velocity was determined for upflow but not for downflow. A limiting inlet velocity of 4.12 m/sec was determined to be the minimum velocity required to completely suppress the influence of buoyancy on the critical heat flux for this saturated inlet flow system. A correlation of this limiting fluid velocity is presented that was developed from previously published subcooled liquid nitrogen data and the saturated data of this investigation.

Papell, S. S.↗

Methodology of Experiment Design for Improving Transient Critical Heat Flux Model Development

One phenomenon that contributes to nuclear fuel and clad failure mechanisms is the departure from nucleate boiling (DNB). Accident scenarios such as reactivity-initiated accidents (RIAs) provide conditions where the frequency of boiling crisis is much more likely to occur and on much shorter time scales than loss of coolant (LOCA) or loss of flow (LOFA) accidents. Here, boiling crisis in the form of DNB is attributed to transient-induced heat flux values that exceed the critical heat flux (CHF). The resulting effects, such as bubble crowding and eventual dryout, can affect flow boiling heat transfer and compromise the structural integrity of nuclear reactor materials. The focus of the work proposed here lies in developing a rigorous process using out-of-pile testing, under simulated RIA conditions, to determine the transient critical heat flux of cladding materials, without contributions from aforementioned radiation-induced effects that have been observed during in-pile experiments. This study provides a road-map for developing and performing experiments that simulate the power profile and energy deposition aspects of transient events, specific to RIAs, on the laboratory scale. The goal of our project is to observe and measure DNB in an annular flow channel around a single heater rod that is operating and nominal thermal hydraulic conditions of a PWR. It is also an aim of these experiments to determine how to quantify the gap between SS and transient CHF cases, based on state-dependent properties of the cladding material type that is being interrogated. Traditionally, CHF is determined as a combination of four factors: hydraulic diameter, system pressure, mass flow, fluid quality. The authors propose that an additional measureable quantity, which is dependent on the structural properties of the cladding material itself, is partly reasonable for the difference between measured and model-developed CHF values. Using a carefully metered approach will allow for several key concepts to be realized: compensation for transient-based effects to current models for CHF; adaptation of current models for different cladding material types, including Gen-IV concept materials; and implementation of a correction factor to account for both power transient-based and radiation-induced effects on the CHF that have not yet been accounted for.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Assessment on DNB performance for high pressure subcooled boiling with modified CASL boiling model

Understanding and predicting the Departure from Nucleation Boiling phenomena in the nuclear power industry has been a grand challenge due to its large impact on the reactor safety and operational economics. Over the past several years, CASL THM team has extensively investigated and demonstrated a state of art Multiphase CFD framework to provide a high-fidelity DNB simulation capability based on the two-fluid Eulerian model in conjunction with a wall heat flux partitioning approach. The overarching goal of this task is to develop and demonstrate a robust CFD-based DNB model which is capable of predicting an entire boiling history up to the DNB condition in which the wall boiling mode is transitioning from the nucleate boiling mode to the film boiling mode. Three different flow channel configurations (pipe flow, 5x5 fuel bundle with and without mixing vane tests) were studied and thorough closure sensitivity studies were performed to evaluate the wall boiling and momentum closure effect on the DNB performance. Predicated DNB values were compared to the measurements from high pressure subcooled flow boiling tests resulting in a consistent under-predictive trend for all three validation campaigns in FY16-18. With extensive closure sensitivity study, a modified CASL boiling closure model (i.e. Gen1-FY19) is introduced with the following key changes: 1) improved wall boiling closure for high pressure application, 2) newly calibrated lift and wall lubrication force models with modified interfacial length scale model, and 3) updated liquid phase condensation model calibrated for the subcooled boiling application.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Implementation of a pressure correction term in the CTF sub-channel code

CTF [1] is a modernized and improved version of the legacy subchannel code, COBRA-TF [2], that is being jointly developed and maintained by Oak Ridge National Laboratory (ORNL) and North Carolina State University. The code was adopted by ORNL for use in the Consortium for Advanced Simulation of Light Water Reactors (CASL) in 2012 for aiding in addressing CASL challenge problems. Since that time, activities related to CTF have included implementing software quality assurance measures, implementing new features and models, performing validation and verification testing, establishing and supporting a CTF User Group, and developing the code for use in coupled applications [3, 4, 5]. CTF is applicable to single- and two-phase flows in light water reactor geometries at normal and accident operating conditions. The two-phase flow model consists of the six-equation two-phase flow model [6] augmented by equations for the droplet field and also includes appropriate source terms. This work focuses on the numerical stability of the six-equation two-phase flow model and is part of a recent eort to improve CTF capabilities for simulating flows in boiling nuclear reactors (BWRs). As it is of common knowledge among the thermodynamic community, the six-equation two-phase flow model is not strongly hyperbolic, meaning some of its eigenvalues are either not real or not distinct [7]. In a Cauchy sense and for an initial-value problem, strong hyperbolicity was found to be equivalent to well-posedness which ensures uniqueness of the solution in the space-time used. This concept is also of importance when designing high-order numerical methods and also when implementing boundary conditions that rely on real eigenvalues such as Riemann solvers. A tremendous amount of research is available in the literature on how to hyperbolize the six-equation two-phase flow model by adding ad hoc terms to the system of equations often referred to as virtual mass or interfacial pressure correction term. From a mathematical prospective, the main idea driving this approach is to add terms to the phasic momentum equation containing first-order partial derivatives of the unknowns to modify the Jacobian matrix and thus canceling the imaginary part of the eigenvalues.For this work it was chosen to implement a interfacial pressure correction (IPC) term on the same model as what was done for the CATHARE system code [8], that allows to recover a two-pressure formulation. In the following, the six-equation two-phase flow model is recalled along with the IPC term and its influence on the eigenvalues. Then, numerical results and convergence studies are presented for a water-faucet problem [9] at a pressure of 10 bar. Finally, conclusions and future work are addressed.

Delchini, Marco↗

Simulations of Cryogenic Line Chilldown with Advanced Sub-Grid Wall Boiling Models

A meso-scale model developed at MIT [2][11] for boiling processes in water was adapted for cryogens and demonstrated for chilldown of propellant transfer lines in both liquid nitrogen and hydrogen. The sub-grid boiling model accurately captures the contributions to heat transfer from the generation of bubble nuclei, growth, and interaction of the bubbles in the microlayer as well as quenching of the boiling surface following bubble departure. It was adapted for cryogenic fluids using thermodynamic scaling concepts taking into account non-dimensional pressures and temperatures that are scaled by the corresponding critical values for the fluid. The boiling model was demonstrated for line chilldown in liquid nitrogen (Darr et al. [6]). The predicted wall temperature at which quenching occurs was close to the test data while the slope of the temperature curve after quenching is initiated, showing a steeper variation than the test data. Simulations were also performed for liquid hydrogen by simulating experiments of Hartwig et al. [7]. Chilldown times in liquid hydrogen are much more rapid due to higher heat transfer in the film boiling regime and accounting for the higher turbulence levels were found to be important. Furthermore, at the much lower fluid temperatures in liquid hydrogen flows, accounting for the variable thermal properties of the solid material is critical and has a dramatic impact on the quench times. The need for additional studies to better understand the evolution of the quench front in liquid hydrogen was noted.

Computational Fluid Dynamics↗

Simulations of Cryogenic Line Chilldown with Advanced Sub-Grid Wall Boiling Models

A meso-scale model developed at MIT [2][11] for boiling processes in water was adapted for cryogens and demonstrated for chilldown of propellant transfer lines in both liquid nitrogen and hydrogen. The sub-grid boiling model accurately captures the contributions to heat transfer from the generation of bubble nuclei, growth, and interaction of the bubbles in the microlayer as well as quenching of the boiling surface following bubble departure. It was adapted for cryogenic fluids using thermodynamic scaling concepts taking into account non-dimensional pressures and temperatures that are scaled by the corresponding critical values for the fluid. The boiling model was demonstrated for line chilldown in liquid nitrogen (Darr et al. [6]). The predicted wall temperature at which quenching occurs was close to the test data while the slope of the temperature curve after quenching is initiated, showing a steeper variation than the test data. Simulations were also performed for liquid hydrogen by simulating experiments of Hartwig et al. [7]. Chilldown times in liquid hydrogen are much more rapid due to higher heat transfer in the film boiling regime and accounting for the higher turbulence levels were found to be important. Furthermore, at the much lower fluid temperatures in liquid hydrogen flows, accounting for the variable thermal properties of the solid material is critical and has a dramatic impact on the quench times. The need for additional studies to better understand the evolution of the quench front in liquid hydrogen was noted.

Computational Fluid Dynamics↗

Boiling incipience and convective boiling of neon and nitrogen

Forced convection and subcooled boiling heat transfer data for liquid nitrogen and liquid neon were obtained in support of a design study for a 30 tesla cryomagnet cooled by forced convection of liquid neon. This design precludes nucleate boiling in the flow channels as they are too small to handle vapor flow. Consequently, it was necessary to determine boiling incipience under the operating conditions of the magnet system. The cryogen data obtained over a range of system pressures, fluid flow rates, and applied heat fluxes were used to develop correlations for predicting boiling incipience and convective boiling heat transfer coefficients in uniformly heated flow channels. The accuracy of the correlating equations was then evaluated. A technique was also developed to calculate the position of boiling incipience in a uniformly heated flow channel. Comparisons made with the experimental data showed a prediction accuracy of plus or minus 15 percent

Papell, S. S.↗