Search NASA⌕ Search

SEARCH · Search NASA

Results for “GHz”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The Atacama Cosmology Telescope: a measurement of the Cosmic Microwave Background power spectra at 98 and 150 GHz

We present the temperature and polarization angular power spectra of the CMB measured by the Atacama Cosmology Telescope (ACT) from 5400 deg2 of the 2013–2016 survey, which covers >15000 deg2 at 98 and 150 GHz. For this analysis we adopt a blinding strategy to help avoid confirmation bias and, related to this, show numerous checks for systematic error done before unblinding. Using the likelihood for the cosmological analysis we constrain secondary sources of anisotropy and foreground emission, and derive a “CMB-only” spectrum that extends to ℓ=4000. At large angular scales, foreground emission at 150 GHz is ∼1% of TT and EE within our selected regions and consistent with that found by Planck. Using the same likelihood, we obtain the cosmological parameters for ΛCDM for the ACT data alone with a prior on the optical depth of τ=0.065±0.015. ΛCDM is a good fit. The best-fit model has a reduced χ2 of 1.07 (PTE=0.07) with H0=67.9±1.5 km/s/Mpc. We show that the lensing BB signal is consistent with ΛCDM and limit the celestial EB polarization angle to ψP =−0.07ˆ±0.09ˆ. We directly cross correlate ACT with Planck and observe generally good agreement but with some discrepancies in TE. All data on which this analysis is based will be publicly released.

79 ASTRONOMY AND ASTROPHYSICS↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

High-volume tunable resonator for axion searches above 7 GHz

In this research, we present results from an experimental demonstration of a tunable thin-shell axion haloscope whose geometry decouples its overall volume from its resonant frequency, thereby evading the steep sensitivity degradation at high frequencies. An aluminum 2.6-l (41⁢λ 3 ) prototype, which tunes from 7.1 to 8.0 GHz, was fabricated and characterized at room temperature. An axion-sensitive, straightforwardly tunable TM 010 mode is clearly identified with a room-temperature quality factor, Q, of approximately 5000. The on-resonance E-field distribution is mapped and found to agree with numerical calculations. Anticipating future cryogenic operation, we develop an alignment protocol relying only on rf measurements of the cavity, maintaining a form factor of 0.57 across the full tuning range. These measurements demonstrate the feasibility of cavity-based haloscopes with operating volume V $\gg$ λ 3 . We discuss plans for future development and the parameters required for a thin-shell haloscope exploring the postinflationary axion parameter space (approximately 4 to 30 GHz) at Dine-Fischler-Srednicki-Zhitnitsky sensitivity.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A 0.2–2 GHz Time-Interleaved Multistage Switched-Capacitor Delay Element Achieving 2.55–448.6 ns Programmable Delay Range and 330 ns/mm 2 Area Efficiency

Simulation of radar returns, full-duplex systems, and signal repeaters require hundreds of ns of programmable broadband radio frequency (RF) delay in the signal path to simulate large distances in the case of radar returns, for signal cancellation in full-duplex, and for isolation from reflections in signal repeaters. However, programmable broadband RF delay has been limited to ones of ns due to challenges in miniaturization with low loss and low power consumption. In this work, we present a 0.2–2 GHz digitally programmable RF delay element based on a time-interleaved multistage switched-capacitor (TIMS-SC) approach. The proposed approach enables hundreds of ns of broadband RF delay by employing sample time expansion in multiple stages of switched-capacitor storage elements. Further, the delay element was implemented in a 45 nm SOI CMOS process and achieves a 2.55–448.6 ns programmable delay range with < 0.12% delay variation across 1.8 GHz of bandwidth at maximum delay, 2.42 ns programmable delay steps, and 330 ns/mm 2 area efficiency. Through the proposed approach, the device shows minimal delay change across a -40 °C to 85 °C temperature range and < 0.25 dB gain variation across delay settings. The device achieves 26 dB gain, 7.4 dB noise figure, and consumes 74 mW from a 1 V supply with an active area of 1.36 mm 2 .

42 ENGINEERING↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fabrication of a Nb-Ti Superconducting Closed-Loop Coil for the Next-Generation 45 GHz ECR Ion Source MARS-D

Electron Cyclotron Resonance Ion Sources (ECRISs) that utilize Nb-Ti superconducting coils for 28 GHz frequencies have been operating effectively for over twenty years. However, transitioning to higher frequencies demands stronger magnetic fields, and the conventional racetrack-and-solenoid ECRIS structures have reached their maximum capability with Nb-Ti. To address this, a Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system features an innovative Closed-Loop Coil (CLC) design that optimizes the use of the conductor fields, enabling the application of Nb-Ti in the next-generation 45 GHz ECRISs. The fabrication of the hexagonal CLC is particularly challenging due to its complex winding path and shape, the stiffness of the Nb-Ti superconducting wire, and the small bending radius. Here, to address these challenges, a series of unique fixtures and tools, as well as a pre-over-bending method, were developed for winding the CLC. To validate the winding fixtures, tools, procedures, and materials used in the coil assembly, a 4-layer practice CLC was wound, epoxy-impregnated, and then cold-tested using liquid nitrogen. The full-size MARS-D CLC is in the process of winding. This paper presents the structure of the MARS-D CLC, the winding fixtures and tools, the winding procedures, the quality control, the impregnation, the test results, and the potential future improvements.

ECR ion sources↗

Design of a Structure for Assembly and Cooling the Magnet of the Next-Generation 45 GHz ECR Ion Source MARS-D

Here, the current Electron Cyclotron Resonance Ion Sources (ECRISs), constructed with Nb-Ti wires and the conventional racetrack-and-solenoid structure, have achieved operating frequencies up to 28 GHz and utilized about 90% of the critical current of the Nb-Ti wire. A Mixed Axial and Radial field System Demonstrator (MARS-D) is being developed at Lawrence Berkeley National Laboratory (LBNL). This system, which consists of an innovative hexagonal Closed-Loop Coil (CLC) and a set of solenoids, can generate higher magnetic fields (up to 150% ) while requiring only about 50% of the superconducting wire, enabling Nb-Ti wires to be used in the next-generation 45 GHz ECRIS. However, the assembly and cooling of such an efficient and compact magnet are particularly challenging due to the small radial gap between the CLC and solenoids, as well as the tight operating temperature margin. To address these challenges, a structure was developed that combines a three-section radially split solenoid mandrel with a series of shrink-fit reinforcement rings and cooling channels. This paper presents the detailed structure, manufacturing method, assembly procedure, impregnation method, mechanical Finite Element Analysis (FEA) comparison, and thermal FEA comparison.

ECR ion sources↗

CCAT-prime: Designs and status of the first light 280 GHz MKID array and mod-cam receiver

The CCAT-prime project's first light array will be deployed in Mod-Cam, a single-module testbed and first light cryostat, on the Fred Young Submillimeter Telescope (FYST) in Chile's high Atacama desert in late 2022. FYST is a six-meter aperture telescope being built on Cerro Chajnantor at an elevation of 5600 meters to observe at millimeter and submillimeter wavelengths. 1 Mod-Cam will pave the way for Prime-Cam, the primary first generation instrument, which will house up to seven instrument modules to simultaneously observe the sky and study a diverse set of science goals from monitoring protostars to probing distant galaxy clusters and characterizing the cosmic microwave background (CMB). At least one feedhorn-coupled array of microwave kinetic inductance detectors (MKIDs) centered on 280 GHz will be included in Mod-Cam at first light, with additional instrument modules to be deployed along with Prime-Cam in stages. The first 280 GHz detector array was fabricated by the Quantum Sensors Group at NIST in Boulder, CO and includes 3,456 polarization- sensitive MKIDs. Current mechanical designs allow for up to three hexagonal arrays to be placed in each single instrument module. We present details on this first light detector array, including mechanical designs and cold readout plans, as well as introducing Mod-Cam as both a testbed and predecessor to Prime-Cam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Offset lock with a 440-GHz range using electro-optic modulation

Offset locking is crucial to many physics experiments. Wide range offset locks are desirable, as they increase the span of usable frequencies in an experiment. Here, we experimentally realize a wide-range offset lock using a beat-note setup combined with electro-optic phase modulation. By using frequency down-conversion of the beat note and locking to sidebands generated by electro-optic modulation, we achieve an offset range of ± 220.1 GHz with offset frequency fluctuations under 0.1 Hz and a phase error variance of 0.017 rad 2 over a 100 kHz bandwidth, greatly widening the range compared to past setups using this method. The relative simplicity of our setup provides a compelling method for locking at offsets in the hundreds of GHz range.

Zhou, Ocean (ORCID:0000000279192636)↗

Development of the first 1 GHz niobium-tin quarter-wave cavity

Niobium-Tin (Nb3Sn) is a promising alternative to pure niobium for low-beta ion accelerators due to low RF losses even at high frequencies. At 4.5 K, the expected Bardeen-Cooper-Schrieffer resistance of Nb3Sn is a few nano-Ohms at 1 GHz, with two orders of magnitude improvement compared to pure niobium. The low Nb3Sn RF losses allow the use of higher frequency, much smaller cavities while maintaining 4.5 K operation that is compatible with cryocoolers. This work aims to demonstrate the feasibility of coating a high-frequency 1 GHz, compact quarter-wave cavity. The development of this cavity has the potential to transform low-beta ion accelerators through size reductions and by enabling the replacement of large helium cryoplants with small plug-in cryocoolers. We have designed, built, and tested a 1GHz Nb3Sn coated quarter-wave cavity. Nb3Sn coating has been performed once by vapor diffusion at Fermilab. Cryogenic cold tests show a quality factor of ~1E9 at low accelerating electric fields or ~7 times higher than the theoretical limit for pure niobium at 1GHz. This first coating does not yet meet our quality factor or gradient goals; however, we plan to continue to develop this cavity.

Zhou, Yang [Argonne]↗

FIRST RESULTS FROM Nb3Sn COATINGS OF 2.6 GHz Nb SRF CAVITIES USING DC CYLINDRICAL MAGNETRON SPUTTERING SYSTEM

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 °C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb-Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 µm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 × 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 × 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 ? 18 K. Here, we present the commissioning experience, system optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

Shakel, M.S.↗

2.6GHz SRF Cavity Tuner for DarkPhoton Experiment [Poster]

There are several experiments ongoing at FNAL that require frequency tuning of bare (undressed) SRF cavities when they are cooled down and operated inside dilution refrigerator. One of these experiments is for the search of dark photons using a 2.6 GHz SRF cavity. The limited heat capacity of a dilution refrigerator prevents using a stepper motor for an SRF cavity tuner. The tuner for the 2.6 GHz SRF cavity will be equipped with encapsulated piezo actuators that will deliver long and short-range frequency tuning. Design of the tuner and results of the testing cavity/tuner system at ambient environment and at T = 77 K will be presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Results From Nb3Sn Coatings of 2.6 GHz Nb SRF Cavities Using DC Cylindrical Magnetron Sputtering System

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 °C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb- Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 μm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 × 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 × 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 – 18 K. Here we present the commissioning experience, s ystem optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

FIRST RESULTS FROM Nb3Sn COATINGS OF 2.6 GHz Nb SRF CAVITIES USING DC CYLINDRICAL MAGNETRON SPUTTERING SYSTEM

A DC cylindrical magnetron sputtering system has been commissioned and operated to deposit Nb3Sn onto 2.6 GHz Nb SRF cavities. After optimizing the deposition conditions in a mock-up cavity, Nb-Sn films are deposited first on flat samples by multilayer sequential sputtering of Nb and Sn, and later annealed at 950 °C for 3 hours. X-ray diffraction of the films showed multiple peaks for the Nb3Sn phase and Nb (substrate). No peaks from any Nb-Sn compound other than Nb3Sn were detected. Later three 2.6 GHz Nb SRF cavities are coated with ~1 µm thick Nb3Sn. The first Nb3Sn coated cavity reached close to Eacc = 8 MV/m, demonstrating a quality factor Q0 of 3.2 × 108 at Tbath = 4.4 K and Eacc = 5 MV/m, about a factor of three higher than that of Nb at this temperature. Q0 was close to 1.1 × 109, dominated by the residual resistance, at 2 K and Eacc = 5 MV/m. The Nb3Sn coated cavities demonstrated Tc in the range of 17.9 ? 18 K. Here, we present the commissioning experience, system optimization, and the first results from the Nb3Sn fabrication on flat samples and SRF cavities.

Shakel, M. S.↗

RF operation of AlN/Al 0.25 Ga 0.75 N/AlN HEMTs with f T /f max of 67/166 GHz

Abstract We report on highly-scaled Al 0.25 Ga 0.75 N channel high electron mobility transistors. Regrown ohmic contacts covering the sidewall of the compressively strained Al 0.25 Ga 0.75 N channel exhibited a low contact resistance ofR c = 0.23 Ω · mm. Scaled devices with a T-shaped gate showed record high speed for any AlGaN-based transistors,f T /f max = 67/166 GHz, while simultaneously achieving high average breakdown field exceeding 2 MV cm −1 . The load-pull measurements performed at 10 GHz revealed a 20% peak power added efficiency with an output power density of 2 W mm −1 , which is mainly limited by the RF dispersion.

Physics↗

Attenuation studies at 35 GHz

Instrumentation and preliminary results of studies of attenuation of 35 GHz radio signals transmitted through the atmosphere are reported. The purpose of this work is to provide information to supplement the ATS-5 downlink tests. Data on atmospheric losses at 35 GHz are being obtained by sun tracker techniques, sky temperature observations, and point-to-point transmissions.

Lo, L.↗

Earth-satellite propagation above GHz: Papers from the 1972 spring URSI session on experiments utilizing the ATS-5 satellite

Papers are reported from the Special Session on Earth-Satellite Propagation Above 10 GHz, presented at The 1972 Spring Meeting of the United States National Committee, International Union of Radio Science, April 1972, Washington, D. C. This session was devoted to propagation measurements associated with the Applications Technology Satellite (ATS-5), which provided the first operational earth-space links at frequencies above 15 GHz. A comprehensive summary is presented of the major results of the ATS-5 experiment measurements and related radiometric, radar and meteorological studies. The papers are organized around seven selected areas of interest, with the results of the various investigators combined into a single paper presented by a principal author for that area. A comprehensive report is provided on the results of the ATS-5 satellite to earth transmissions. A complete list of published reports and presentations related to the ATS-5 Millimeter Wave Experiment is included.

Ippolito, L. J.↗

Dispersion studies of the 22 GHz water vapor line shape. II - Instrumental correction.

Anomalies in the resonance dispersion of the pressure-broadened water vapor line at a frequency of 22.235 GHz are resolved. The pressure-scanning differential-refraction spectrometer gives rise to a signal enhancement as the line center moves within the width of the dispersion discriminator. Resonance absorption prevents the frequency of peak transmitted power from coinciding with the resonance condition of zero phase. The results reported for the 23.6 GHz rotational line of ethylene oxide show a Lorentzian molecular line shape.

Dillon, T. A.↗