Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas Exchange”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Performance and Durability Investigation of Thin, Low Crossover Proton Exchange Membranes for Water Electrolyzers

The goal of this project was to fabricate and study the performance and durability implications of thin, mechanically reinforced membranes containing gas recombination catalysts (GRCs) for advanced proton exchange membrane water electrolysis (PEMWE) systems. The thinner membranes, optimized for a PEMWE environment, dramatically reduced the proton transport resistance across the membrane, improving the overall efficiency of the PEMWE system. At the same time, the GRC technology was deployed to recombine crossover hydrogen from the cathode with oxygen from the anode to form water within the membrane. This reaction mitigated the buildup of hydrogen in the oxygen stream, ensuring safe operation of the PEMWE system. Capabilities to measure the gas crossover in both an ex-situ screening cell and in operando application testing were developed over the course of the project to track membrane progress and quantify deliverables. State of the art roll to roll manufacturing technologies were leveraged to fabricate the membranes on a commercial scale, where the membrane structure was precisely tuned and GRC distributed within the membrane structure.

08 HYDROGEN↗

Hydroxylation and Cation Segregation in (La 0.5 Sr 0.5 )FeO 3-$δ$ Electrodes

Simultaneously achieving high activity and stability is the primary challenge when engineering (electro)catalysts. Transition metal perovskite oxides are employed as air electrodes for solid-oxide fuel cells and electrolyzers. However, degradation of oxygen exchange kinetics at the solid–gas interface, often linked to alkaline-earth cation segregation and precipitation, limits widespread commercialization. Here, we systematically investigated the surface degradation mechanism induced by gas-phase impurities in La 0.5 Sr 0.5 )FeO 3-$δ$ (LSF55) thin-film electrodes by varying the concentration of H 2 O, SO 2 , and CO 2 . Degradation of the area-specific resistance in ambient and humidified synthetic air is significantly greater than in dry ambient and dry synthetic air, pointing to the importance of water vapor. Time-resolved, in situ ambient pressure X-ray photoelectron spectroscopy performed in O 2 showed that nonbulk Sr is present on the surface before the exposure to water vapor. Upon introduction of water vapor, neither additional Sr segregation nor precipitation driven by water vapor is a necessary condition for degradation. Rather, hydroxylation of the surface induces irreversible and significant degradation. At the same time, we show that Sr migration driven by water vapor is partially reversible. These fundamental insights can be used for the rational design of electrodes with improved catalytic stability.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Silica: ubiquitous poison of metal oxide interfaces

In this review, we consider the detrimental effects of Si-contamination on electrochemical applications, broadly conceived, in which both ions and electrons play key roles in device operation and where exchange of oxygen between the gas and solid phase is likewise essential for operation.

30 DIRECT ENERGY CONVERSION↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Microsized Pore Structure Determination in EPDM Rubbers Using High-Pressure 129 Xe NMR Techniques

Microsized pore parameters, such as pore size and distance between pores in a series of model EPDM rubbers, were determined in situ under the pressure of 500 psi using 129 Xe nuclear magnetic resonance (NMR) techniques: spin–lattice (T 1 ) and spin–spin (T 2 ) relaxation measurements, pulsed-field gradient (PFG) NMR, and two-dimensional exchange spectroscopy (2D EXSY). The T 1 /T 2 (>>1) ratio for the xenon confined in the pores is larger than that for nonconfined free xenon. This suggests that almost the entire pore surface interacts with xenon atoms like a closed pore. While these pores still connect each other through very narrow diffusion/exchange channels, it is possible to observe the echo decay in PFG-NMR and cross-peaks in 2D EXSY. The results show that both diffusion (D pore ≈ 2.1 × 10 –10 m 2 /s) and exchange (exchange rate, τ exch = a few tens of milliseconds) of xenon between a pore within the material and outer surface are prolonged. The exchange distances (l), which correspond to the xenon gas penetration depth, were estimated to be 70–100 μm based on the measured diffusion coefficients and exchange rate (1/τ exch ). NMR diffraction analysis reveals that pore size (a) and pore distance (b) are on the order of magnitude of micrometers and tens of micrometers, while the diffusion coefficients of xenon gas in the diffusion channels (D eff ) are about 10 –8 m 2 /s. Overall, this study suggests that the pores with a few micrometers connected through very narrow flowing channels with the length of several tens of micrometers are developed 70 to 100 μm below the rubber surface. Furthermore, the overall steady-state diffusion of xenon is slower, approximately 2 orders of magnitudes, than the diffusion in the channel between the pores. Finally, the pore and exchange distances correlated with the composition of rubbers showed that the properties of EPDM rubber as a high-pressure gas barrier could be improved by reducing the size of cracks and the depth of gas penetration by the addition of both carbon black and silica fillers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Crosslinked Anionic Exchange Membranes (Spring Quarter Report)

With ever growing climate concerns, studying and optimizing hydrogen gas electrolyzers and fuel cells are of high importance. Polymeric anionic exchange membranes (AEM) are attractive replacements to the industry standard proton exchange membranes (PEM) due to their lack of precious metal catalysts and acidic conditions. However, AEMs on the market have yet to preform comparatively to PEMs. To bring AEMs to a competitive level, crosslinking chemistry within the polymer membranes is being investigated to enhance mechanical properties and performance. For this quarter, electrochemical systems, important AEM properties and considerations, and some characterization methods will be reviewed.

08 HYDROGEN↗

Method for separating components of a gas

A method is disclosed for separating components of a gas. A feed gas stream is cooled in the first vessel. The feed gas stream comprises methane, carbon dioxide, and a secondary component. A first portion of the secondary component condenses, desublimates, or a combination thereof to form a primary stream, resulting in a first depleted gas stream. The first depleted gas stream is cooled in a condensing exchanger such that a first portion of the methane condenses as a first liquid methane stream, resulting in a second depleted gas stream. The second depleted gas stream is cooled in the second vessel such that a first portion of the carbon dioxide desublimates to form a solid product stream, resulting in a third depleted gas stream.

Baxter, Larry↗

Correlation energy of the uniform electron gas determined by ground-state conditional probability density functional theory

Conditional-probability density functional theory (CP-DFT) is a formally exact method for finding correlation energies from Kohn-Sham DFT without evaluating an explicit energy functional. We present details on how to generate accurate exchange-correlation energies for the ground-state uniform gas. We also use the exchange hole in a CP antiparallel spin calculation to extract the high-density limit. We give a highly accurate analytic solution to the Thomas-Fermi model for this problem, showing its performance relative to Kohn-Sham and may be useful at high temperatures. We explore several approximations to the CP potential. Furthermore, results are compared to accurate parameterizations for both exchange-correlation energies and holes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Carbon-Carbon Aeroshell Chemical Reaction Model in an Open RPS in Martian Environment

A new RPS is being designed to be open to the vacuum of space to improve its thermal efficiency during deep space missions. This design, however, could lead to some potential complications if it is ever used in the low-pressure gas environment of mission destinations like Mars. This report documents the development of a chemical kinetics reaction model of the FWPF carbon-carbon aeroshell in the Martian gaseous environment. This model uses an “infinite sink” assumption where the RPS is open to the Martian environment with open exchange of flowing gases, so the gas chemistry over the aeroshell does not change with the reaction and represents the worst case scenario of the chemical reaction of the FWPF in the Martian environment. The model combines the kinetics equation of both oxidation reactions that would occur on Mars: the Langmuir-Hinshelwood kinetics of the Boudouard reaction of CO 2 with the chemical kinetics of O 2 oxidation of the carbon-carbon. The FWPF chemical reaction model was benchmarked using the Opila’s experimental chemical reaction test data (1) in a simulated Martian environment to increase the validity of the model’s predicted mass loss rate. The output of the benchmarked chemical reaction model showed a trade-off between the maximum temperature of the aeroshell to have less than 10% reaction at the mission life. For example, an RPS with a five-year intended mission life on Mars has a maximum aeroshell temperature of 835 K / 562 °C, increasing the mission life to ten years reduces the maximum operating temperature to 810 K / 527 °C. If the aeroshell operating temperature in the new RPS on the surface of Mars is 960 Kelvin, the model calculates that the life is limited to 0.22 years / 81 days. Increasing the aeroshell temperature to 1343 Kelvin, further reduces the life to 0.375 days / 9 hrs. This illustrates the thermally activated nature of the chemical kinetics model in limiting the life of the aeroshell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Carbon-Carbon Aeroshell Chemical Reaction Model in an Open RPS in Martian Environment

A new RPS is being designed to be open to the vacuum of space to improve its thermal efficiency during deep space missions. This design, however, could lead to some potential complications if it is ever used in the low-pressure gas environment of mission destinations like Mars. This report documents the development of a chemical kinetics reaction model of the FWPF carbon-carbon aeroshell in the Martian gaseous environment. This model uses an “infinite sink” assumption where the RPS is open to the Martian environment with open exchange of flowing gases, so the gas chemistry over the aeroshell does not change with the reaction and represents the worst case scenario of the chemical reaction of the FWPF in the Martian environment. The model combines the kinetics equation of both oxidation reactions that would occur on Mars: the Langmuir-Hinshelwood kinetics of the Boudouard reaction of CO2 with the chemical kinetics of O2 oxidation of the carbon-carbon. The FWPF chemical reaction model was benchmarked using the Opila’s experimental chemical reaction test data (1) in a simulated Martian environment to increase the validity of the model’s predicted mass loss rate. The output of the benchmarked chemical reaction model showed a trade-off between the maximum temperature of the aeroshell to have less than 10% reaction at the mission life. For example, an RPS with a five-year intended mission life on Mars has a maximum aeroshell temperature of 835 K / 562 °C, increasing the mission life to ten years reduces the maximum operating temperature to 810 K / 527 °C. If the aeroshell operating temperature in the new RPS on the surface of Mars is 960 Kelvin, the model calculates that the life is limited to 0.22 years / 81 days. Increasing the aeroshell temperature to 1343 Kelvin, further reduces the life to 0.375 days / 9 hrs. This illustrates the thermally activated nature of the chemical kinetics model in limiting the life of the aeroshell.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Isotope Exchange of ND 3 on Pt Catalyst–Loaded 5A Molecular Sieve

Recollecting and purifying unburned tritium is a preferred process for D-T fusion operations. However, tritium containing byproducts act as a potential holdup for the material, requiring additional processing to liberate the tritium. Furthermore, using deuterium as a surrogate for tritium, this work demonstrates the capture and isotope exchange of deuterated ammonia using a Pt catalyst–loaded 5A molecular sieve, performed at ambient temperatures, verified by the analysis of the effluent gas streams and desorbed ammonia isotopologues post exchange.

5A↗

Discovering Reactant Supply Pathways at Electrode/PEM Reaction Interfaces Via a Tailored Interface-Visible Characterization Cell

In situ and micro-scale visualization of electrochemical reactions and multiphase transports on the interface of porous transport electrode (PTE) materials and solid polymer electrolyte (SPE) has been one of the greatest challenges for electrochemical energy conversion devices, such as proton exchange membrane electrolyzer cells (PEMECs), CO 2 reduction electrolyzers, PEM fuel cells, etc. Here, an interface-visible characterization cell (IV-CC) is developed to in situ visualize micro-scaled and rapid electrochemical reactions and transports in PTE/SPE interfaces. Taking the PEMEC of a green hydrogen generator as a study case, the unanticipated local gas blockage, micro water droplets, and their evolution processes are successfully visualized on PTE/PEM interfaces in a practical PEMEC device, indicating the existence of unconventional reactant supply pathways in PEMs. Further comprehensive results reveal that PEM water supplies to reaction interfaces are significantly impacted with current densities. Here these results provide critical insights about the reaction interface optimization and mass transport enhancement in various electrochemical energy conversion devices.

30 DIRECT ENERGY CONVERSION↗

Demonstration of Improved CHP Systems utilizing Improved Gas Turbine and sCO2 Cycles Using Additive Manufacturing (AM) Components

This project seeks to integrate a sCO2 bottoming cycle with a 5.3 MW gas turbine to develop a CHP system that is able to transition rapidly between 50% and 100% load by engaging or bypassing the bottoming cycle while maintaining electrical system efficiency above 30% at all times. The project team will engineer an optimized design of the power systems. The needed new key components, such as advanced heat exchangers and a steam injection system for the gas turbine, will be developed and their performance demonstrated in rig tests. The feasibility of the whole integrated CHP system will be validated through a cyber-physical approach.

36 MATERIALS SCIENCE↗

Experimental Characterization of an Additively Manufactured Inconel 718 Heat Exchanger for High-Temperature Applications

This work presents the experimental results of a novel, air-to-air, additively manufactured manifold-microchannel heat exchanger with straight fins on both sides. The heat exchanger was made of Inconel 718 using a direct metal laser sintering technique. The overall core size of the heat exchanger was 94 mm × 87.6 mm × 94.4 mm, with a fin thickness of 0.220 mm on both the hot and cold sides. The heat exchanger was tested with pressurized nitrogen gas at 300 °C and 340 kPa for the hot side, while air at an ambient condition was used for the cold side. An overall heat transfer of 276 W/m2K was obtained for Reynolds number values of 132 and 79 for the cold and hot sides, respectively. A gravimetric heat transfer density (Q/m∆T) of 4.7–6.7 W/kgK and a volumetric heat transfer density (Q/V∆T) of 6.9–9.8 kW/m3K were recorded for this heat exchanger with a coefficient of performance value that varied from 42 to 52 over the operating conditions studied here. The experimental pressure drop results were within 10% of the numerical values, while the corresponding heat transfer results were within 17% of the numerical results, mainly due to imperfections in the fabrication process. Despite this penalty, the performance of the tested heat exchanger was superior to the conventional plate-fin heat exchangers: more than 60% of improvements in both gravimetric and volumetric heat transfer densities were recorded for the entire range of experimental data.

42 ENGINEERING↗

Ideas and perspectives: Enhancing research and monitoring of carbon pools and land-to-atmosphere greenhouse gases exchange in developing countries

Carbon (C) and greenhouse gas (GHG) research has traditionally required data collection and analysis using advanced and often expensive instruments, complex and proprietary software, and highly specialized research technicians. Partly as a result, relatively little C and GHG research has been conducted in resource-constrained developing countries. At the same time, these are often the same countries and regions in which climate change impacts will likely be strongest and in which major science uncertainties are centered, given the importance of dryland and tropical systems to the global C cycle. Increasingly, scientific communities have adopted appropriate technology and approach (AT&A) for C and GHG research, which focuses on low-cost and low-technology instruments, open-source software and data, and participatory and networking-based research approaches. Adopting AT&A can mean acquiring data with fewer technical constraints and lower economic burden and is thus a strategy for enhancing C and GHG research in developing countries. However, AT&A can have higher uncertainties; these can often be mitigated by carefully designing experiments, providing clear protocols for data collection, and monitoring and validating the quality of obtained data. For implementing this approach in developing countries, it is first necessary to recognize the scientific and moral importance of AT&A. At the same time, new AT&A techniques should be identified and further developed. All these processes should be promoted in collaboration with local researchers and through training local staff and encouraged for wide use and further innovation in developing countries.

Kim, Dong-Gill↗

Integrated Ammonia Capture and Exchange on Ion‐Exchanged 4A Zeolites

Ammonia poses a challenge in effluent gas streams due to its corrosive nature. However, in fusion settings tritiated ammonia can be formed, leading to both tritium loss in inventory and the generation of reactive species. Therefore, identifying pathways in which both tritium can be recovered, and the ammonia can be easily handled would be beneficial. One such way to do so would be to combine two useful techniques: ammonia sequestration and hydrogen exchange (ND 3 →NH 3 ). However, materials that can both adsorb ammonia and subsequently perform reactions on ammonia have not been well explored. Here, in this work, we present the development of ion-exchanged A-type zeolites to be utilized as a support material for platinum catalysts. In this way, the zeolite can adsorb ammonia and the platinum catalyst can facilitate hydrogen exchange allowing for bifunctional reactivity of the material to be achieved. A variety of elements were explored for their effect on A-type zeolites and resulted in an isotopic difference in the adsorption of ND 3 and NH 3 , noting the use of deuterium as a surrogate for tritium. Several platinum-impregnated zeolites were able to remove ND 3 from the gas stream, indicating that utilizing these materials in isotope recovery processes would improve accountability of these valuable hydrogen isotopes.

Koch, Christopher J. [Savannah River National Labo↗