Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

H I CONTENT AND OPTICAL PROPERTIES OF FIELD GALAXIES FROM THE ALFALFA SURVEY. I. SELECTION OF A CONTROL SAMPLE

We report results from a study of the H I content and stellar properties of nearby galaxies detected by the Arecibo Legacy Fast ALFA blind 21 cm line survey and the Sloan Digital Sky Survey. We consider two declination strips covering a total area of 9 hr x 16 deg in the general direction of the Virgo Cluster. The present analysis focuses on gas-rich galaxies expected to show little or no evidence of interaction with their surroundings. We seek to assemble a control sample suitable for providing absolute measures of the H I content of gaseous objects, as well as to study the relationship between H I emission and widely used optical measures of morphology. From a database which includes more than 15,000 H I detections, we have assembled three samples that could provide adequate H I standards. The most reliable results are obtained with a sample of 5647 sources found in low-density environments, as defined by a nearest neighbor approach. The other two samples contain several hundred relatively isolated galaxies each, as determined from standard isolation algorithms based either on a combination of spectroscopic and photometric information or solely on photometric data. We find that isolated objects are not particularly gas-rich compared to their low-density-environment counterparts, while they suffer from selection bias and span a smaller dynamic range. All this makes them less suitable for defining a reference for H I content. We have explored the optical morphology of gaseous galaxies in quiet environments, finding that, within the volume surveyed, the vast majority of them display unequivocal late-type galaxy features. In contrast, bona fide gas-rich early-type systems account only for a negligible fraction of the 21 cm detections. We argue that H I emission provides the most reliable way to determine the morphological population to which a galaxy belongs. We have also observed that the color distribution of flux-limited samples of optically selected field H I emitters does not vary significantly with increasing distance, while that of non-detections becomes notably redder. This result suggests that the colors and H I masses of gas-rich galaxies cannot be very closely related.

79 ASTRONOMY AND ASTROPHYSICS↗

Waste Isolation Pilot Plant Flammable Gas Analysis (Rev. 3.1)

This document describes and implements the process to determine the concentration of flammable gas/volatile organic compounds (VOCs), hydrogen, and methane in a waste container intended for shipment in the Transuranic Package Transporter-II (TRUPACT-II), HalfPACT, or RH-TRU 72-B packagings. An aliquot of headspace gas (HSG) is sampled from a waste container and analyzed using a gas chromatograph (GC) with two detectors: a mass spectrometer (MS), and a thermal conductivity detector (TCD). The sample analyzed in the GC is split and half is sent to the MS for volatile organic compound (VOC) analysis while the other half is sent to the TCD for hydrogen and methane analysis. The requirements and technical bases for allowable flammable gas/VOC concentrations are described in the Contact-Handled Transuranic Waste Authorized Methods for Payload Control (CH-TRAMPAC) and the Remote-Handled Transuranic Waste Authorized Methods for Payload Control (RHTRAMPAC).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portable Automation of Static Chamber Sample Collection for Quantifying Soil Gas Flux

Quantification of soil gas flux using the static chamber method is labor intensive. The number of chambers that can be sampled is limited by the spacing between chambers and the availability of trained research technicians. An automated system for collecting gas samples from chambers in the field would eliminate the need for personnel to return to the chamber during a flux measurement period and would allow a single technician to sample multiple chambers simultaneously. This study describes Chamber Automated Sampling Equipment (FluxCASE) to collect and store chamber headspace gas samples at assigned time points for the measurement of soil gas flux. The FluxCASE design and operation is described, and the accuracy and precision of the FluxCASE system is evaluated. In laboratory measurements of nitrous oxide (N2O), carbon dioxide (CO2), and methane (CH4) concentrations of a standardized gas mixture, coefficients of variation associated with automated and manual sample collection were comparable, indicating no loss of precision. In the field, soil gas fluxes measured from FluxCASEs were in agreement with manual sampling for both N2O and CO2. Slopes of regression equations were 1.01 for CO2 and 0.97 for N2O. The 95% confidence limits of the slopes of the regression lines included the value of one, indicating no bias. Additionally, an expense analysis found a cost recovery ranging from 0.6 to 2.2 yr. Implementing the FluxCASE system is an alternative to improve the efficiency of the static chamber method for measuring soil gas flux while maintaining the accuracy and precision of manual sampling.

Davis, Morgan P.↗

Do blue galaxy-clusters have hot intracluster gas?

Abstract We present herein a systematic X-ray analysis of blue galaxy clusters at z = 0.84 discovered by the Subaru telescope. The sample consisted of 43 clusters identified by combining red-sequence and blue-cloud surveys, covering a wide range of emitter fractions (i.e., 0.3–0.8). The spatial extent of the over-density region of emitter galaxies was approximately 1 Mpc in radius. The average cluster mass was estimated as 0.6(<1.5) × 1014 M⊙ from the stacked weak-lensing measurement. We analyzed the XMM-Newton archival data, and measured the X-ray luminosity of the hot intracluster medium. As a result, diffuse X-ray emission was marginally detected in 14 clusters, yielding an average luminosity of 5 × 1042 erg s−1. To the contrary, it was not significant in 29 clusters. The blue clusters were significantly fainter than the red-dominated clusters, and the X-ray luminosity did not show any meaningful correlation either with emitter fraction or richness. The X-ray surface brightness was low, but the amount of gas mass was estimated to be comparable to that observed in the 1013–1014 M⊙ cluster. Based on the results, we suggest that the blue clusters are at the early formation stage, and the gas is yet to be compressed and heated up to produce appreciable X-rays. Follow-up spectroscopic measurements are essential to clarify the dynamical status and co-evolution of galaxies and hot gas in the blue clusters.

Misato, Rana↗

Capillary absorption spectrometer and process for isotopic analysis of small samples

A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The method also permits sampling in vivo permitting real-time ambient studies of microbial communities.

47 OTHER INSTRUMENTATION↗

Capillary absorption spectrometer and process for isotopic analysis of small samples

A capillary absorption spectrometer and process are described that provide highly sensitive and accurate stable absorption measurements of analytes in a sample gas that may include isotopologues of carbon and oxygen obtained from gas and biological samples. It further provides isotopic images of microbial communities that allow tracking of nutrients at the single cell level. It further targets naturally occurring variations in carbon and oxygen isotopes that avoids need for expensive isotopically labeled mixtures which allows study of samples taken from the field without modification. The process also permits sampling in vivo permitting real-time ambient studies of microbial communities.

47 OTHER INSTRUMENTATION↗

Optimizing Cryo-Focused Pyrolysis GC/MS for Tracing Soil Organic Matter Across Diverse Ecosystems

The cycling of organic matter in terrestrial soils and sediments is central to a range of biogeochemical processes that regulate nutrient cycling, crop productivity, trace gas emissions, and contaminant transport. Pyrolysis-gas chromatography/mass spectrometry (py-GC/MS) is a powerful tool for characterizing bulk soil organic matter (SOM) at the molecular level. In this study, we used a cryo-focused py-GC/MS system to analyze soil samples from seven diverse ecosystems: vernal pool, prairie pothole, temperate forest, tropical forest, tundra, wildfire-affected boreal forest, and grassland. We addressed a key bottleneck in molecular-level SOM characterization by developing an automated data analysis pipeline to optimize py-GC/MS and complementary evolved gas analysis/mass spectrometry (EGA/MS) methods, incorporating advanced tools for peak deconvolution, developing a custom compound class library, and implementing fragmentation spectrum-based molecular networking for the first time. This improved workflow was applied to soil samples from all seven ecosystems, including multiple depths and density fractions. Our findings demonstrate that ecosystem type plays a dominant role in shaping compositional differences in SOM. We also identified trends in the source of SOM compounds (e.g., microbial vs plantderived) across soil depth and density fractions, which are critical for understanding persistence and turnover of SOM. Our molecular networking analysis indicated that although many compounds are widespread across ecosystems, others are restricted to specific environments, such as wetlands. This underscores the utility of molecular-level data in elucidating the complexity of SOM composition and the environmental drivers that shape it. Such molecular-level insights can deepen our knowledge of biogeochemical SOM cycles.

54 ENVIRONMENTAL SCIENCES↗

Synthesis route attribution of sulfur mustard by multivariate data analysis of chemical signatures

A multivariate model was developed here to attribute samples to a synthetic method used in the production of sulfur mustard (HD). Eleven synthetic methods were used to produce 66 samples for model construction. Three chemists working in both participating laboratories took part in the production, with the aim to introduce variability while reducing the influence of laboratory or chemist specific impurities in multivariate analysis. A gas chromatographic/mass spectrometric data set of peak areas for 103 compounds was subjected to orthogonal partial least squares - discriminant analysis to extract chemical attribution signature profiles and to construct multivariate models for classification of samples. For one- and two-step routes, model quality allowed the classification of an external test set (16/16 samples) according to synthesis conditions in the reaction yielding sulfur mustard. Classification of samples according to first-step methodology was considerably more difficult, given the high purity and uniform quality of the intermediate thiodiglycol produced in the study. Model performance in classification of aged samples was also investigated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolution of Mass Spectrometers for High m / z Biological Ion Formation, Transmission, Analysis and Detection: A Personal Perspective

Mass spectrometry (MS) has become an essential tool in virtually all academic, pharmaceutical, and biopharmaceutical analytical laboratories. The specialized and bespoke area of MS research and application of high m / z ion (> m / z 6000 and high mass, >150 kDa) formation, transmission, analysis, and detection is a relatively new area of focus for MS that has seen dramatic acceleration in interest over the last two decades. Herein we delve into this exciting aspect of MS, discussing how MS instrumentation has been refined and evolved for native-MS analysis. We cover the early groundbreaking experiments showing high m / z ion formation, transmission, and preservation of protein structure in the gas phase. Additionally, we discuss specific instrument optimizations and modifications that have advanced high m / z ion generation, transmission, analysis, and detection, contributing to the research area known as gas-phase structural biology. Native-MS sample introduction methods, emerging technologies, and future perspectives are also examined. Finally, we share personal opinions, observations, and experiences that are new to the community or previously unpublished.

collisions↗

Using Carbon Isotope Fractionation to Constrain the Extent of Methane Dissolution Into the Water Column Surrounding a Natural Hydrocarbon Gas Seep in the Northern Gulf of Mexico

A gas bubble seep located in the northern Gulf of Mexico was investigated over several days to determine whether changes in the stable carbon isotopic ratio of methane can be used as a tracer for methane dissolution through the water column. Gas bubble and water samples were collected at the seafloor and throughout the water column for isotopic ratio analysis of methane. Our results show that changes in methane isotopic ratios are consistent with laboratory experiments that measured the isotopic fractionation from methane dissolution. A Rayleigh isotope model was applied to the isotope data to determine the fraction of methane dissolved at each depth. On average, the fraction of methane dissolved surpasses 90% past an altitude of 400 m above the seafloor. Methane dissolution was also investigated using a modified version of the Texas A&M Oil spill (Outfall) Calculator (TAMOC) where changes in methane isotopic ratios could be calculated. The TAMOC model results show that dissolution depends on depth and bubble size, explaining the spread in measured isotopic ratios during our investigations. Both the Rayleigh and TAMOC models show that methane bubbles quickly dissolve following emission from the seafloor. Together, these results show that it is possible to use measurements of natural methane isotopes to constrain the extent of methane dissolution following seafloor emission.

58 GEOSCIENCES↗

Analysis of antifoam agent degradation products in an evaporator

A wetting agent used to control foaming in the Chemical Processing Cell at the Defense Waste Processing Facility degrades to form compounds that could volatilize to form vapor exceeding the lower flammability limit. Three identified components of concern were hexamethyl disiloxane, trimethyl silanol, and propanal. Analytical methods were developed and implemented on a real waste sample to monitor degradation products. In this work, using standards, an extraction method with dichloromethane and analysis by gas chromatography-mass spectrometry and hydrogen nuclear magnetic resonance was developed. Both methods had detection limits less than 1 mg/L for the analytes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Mechanical relaxation in thermoelectric oxide Ca{sub 3−x}Sr{sub x}Co{sub 4}O{sub 9+δ} (x=0, 0.25, 0.5, 1.0) associated with oxygen vacancies

Ca{sub 3}Co{sub 4}O{sub 9+δ} has a unique structure that leads to exceptionally good thermoelectric (TE) properties. To change the concentration of oxygen vacancies (OVs) of the sample, the same sintered Ca{sub 3}Co{sub 4}O{sub 9+δ} polycrystalline ceramic suffered treating in 30 wt% oxydol (H{sub 2}O{sub 2}) solution and then annealing at 600 °C in pure N{sub 2}-gas atmosphere. Before and after each treatment, we performed dynamic mechanical analysis (DMA) with different frequencies, X-ray photoelectron spectroscopy (XPS) and thermogravimetric analysis (TGA) on the sample. A relaxation peak was observed at the temperature range from 90 °C to 150 °C, and the relaxation process is most likely caused by the migration of single OVs. The consistency in the results from TGA and XPS could well support the conclusion that the OVs of Ca{sub 3}Co{sub 4}O{sub 9+δ} are located on the O site of CoO layer in Ca{sub 2}CoO{sub 3} subsystem. Further DMA investigations on the Ca{sub 3−x}Sr{sub x}Co{sub 4}O{sub 9+δ} (x=0, 0.25, 0.5, 1.0) ceramic indicated that Sr substitution of Ca could suppress the relaxation peak, suggesting the migration of single OVs mainly processes between CoO and CaO layers of Ca{sub 2}CoO{sub 3} subsystem. - Graphical abstract: A relaxation peak and a transition peak could be observed in the internal friction spectra of Ca{sub 3}Co{sub 4}O{sub 9+δ}. The calculated activation energy indicates the relaxation process is associated with migration of oxygen vacancies. Highlights: ► We performed dynamic mechanical analysis on the thermoelectric oxide Ca{sub 3}Co{sub 4}O{sub 9+δ}. ► We observed a relaxation peak and a transition peak. ► The oxygen vacancies are located in CoO layer of Ca{sub 2}CoO{sub 3} subsystem. ► The relaxation peak originates from migration of single oxygen vacancies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic methods and systems for isotopic analysis

Disclosed are spectroscopy systems and methods. A spectroscopy system can include a reference cell and a multi-pass sample cell. The reference arm can include an etalon and a reference cavity containing a reference gas. A system can include a fractional sublimation cold trap. Detectors of the reference and sample arms can detect both intensity and absorption spectra of impinging beams. A frequency calibration based on a reference absorption spectra can be used to analyze a sample absorption spectrum. The analysis can provide information regarding an absorption band shift of the sample absorption spectrum, said shift being related to the isotope concentration of the sample.

O'Rourke, Patrick E.↗

Sampling and mass spectrometry approaches for the detection of drugs and foreign contaminants in breath for homeland security applications

Homeland security relies heavily on analytical chemistry to identify suspicious materials and persons. Traditionally this role has focused on attribution, determining the type and origin of an explosive, for example. But as technology advances, analytical chemistry can and will play an important role in the prevention and preemption of terrorist attacks. More sensitive and selective detection techniques can allow suspicious materials and persons to be identified even before a final destructive product is made. The work presented herein focuses on the use of commercial and novel detection techniques for application to the prevention of terrorist activities. Although drugs are not commonly thought of when discussing terrorism, narcoterrorism has become a significant threat in the 21st century. The role of the drug trade in the funding of terrorist groups is prevalent; thus, reducing the trafficking of illegal drugs can play a role in the prevention of terrorism by cutting off much needed funding. To do so, sensitive, specific, and robust analytical equipment is needed to quickly identify a suspected drug sample no matter what matrix it is in. Single Particle Aerosol Mass Spectrometry (SPAMS) is a novel technique that has previously been applied to biological and chemical detection. The current work applies SPAMS to drug analysis, identifying the active ingredients in single component, multi-component, and multi-tablet drug samples in a relatively non-destructive manner. In order to do so, a sampling apparatus was created to allow particle generation from drug tablets with on-line introduction to the SPAMS instrument. Rules trees were developed to automate the identification of drug samples on a single particle basis. A novel analytical scheme was also developed to identify suspect individuals based on chemical signatures in human breath. Human breath was sampled using an RTube{trademark} and the trace volatile organic compounds (VOCs) were preconcentrated using solid phase microextraction (SPME) and identified using gas chromatography - mass spectrometry (GC-MS). Modifications to the sampling apparatus allowed for increased VOC collection efficiency, and reduced the time of sampling and analysis by over 25%. The VOCs are present in breath due to either endogenous production, or exposure to an external source through absorption, inhalation, or ingestion. Detection of these exogenous chemicals can provide information on the prior location and activities of the subject. Breath samples collected before and after exposure in a hardware store and nail salon were analyzed to investigate the prior location of a subject; breath samples collected before and after oral exposure to terpenes and terpenoid compounds, pseudoephedrine, and inhalation exposure to hexamine and other explosive related compounds were analyzed to investigate the prior activity of a subject. The elimination of such compounds from the body was also monitored. In application, this technique may provide an early warning system to identify persons of interest in the prevention and preemption stages of homeland security.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Description of the Gas Sampling and Circulation System for the LYNM PE1-A Experiment

A series of multiphysics experiments, referred to as Physics Experiment 1 (PE1) is underway at the U.S. Nevada National Security Site. The PE1 series includes detonations of three underground chemical explosions. As the name implies, there are a number of experiments investigating the signals generated by the explosion. The experiment series objectives are outlined in a report from Lawrence Livermore National Laboratory.1 One of the experiments is a gas migration experiment. Gas tracers were imbedded in the explosives and gas sampling boreholes were installed in the formation in the test bed. Connected to the monitoring points is a circulation system that moves gas to a central measurement location. This report does not describe the gas analysis or collection systems, but rather the circulation system that provides the gas for measurement. Here, we have combined four project documents into a single report that describes the design, build, installation, testing, and operation of the gas sampling network.

42 ENGINEERING↗

High-energy synchrotron study of in-pile-irradiated U–Mo fuels

Here synchrotron scattering analysis results on U–7wt.%Mo fuel specimens irradiated in the Advanced Test Reactor to three burnup levels (3.0, 5.2, and 6.3 × 1021 fission/cm3) are reported. Mature fission gas bubble superlattice was observed to form at intermediate burnup. The superlattice constant was determined to be 11.7 and 12.0 nm by wide-angle and small-angle scattering respectively. Grain sub-division takes place throughout the irradiation and causes the collapse of the superlattice at high burnup. The bubble superlattice expands the U–Mo lattice and acts as strong sink for radiation-induced defects. The evolution of dislocation loops was, therefore, suppressed until the bubble superlattice collapsed.

metallic nuclear fuel↗

Adsorptive Films in Support of In-field UF6 Destructive Assay Sample Collection and Analysis

International Atom Energy Agency (IAEA) safeguard verification measures in gaseous centrifuge enrichment plants (GCEPs) rely on environmental sampling, non-destructive assay (NDA), and destructive assay (DA) sampling and analysis to determine uranium enrichment. UF6 bias defect measurements are made by DA sampling and analysis to assure that enrichment is consistent with declarations. DA samples are collected from a limited number of cylinders for high precision, offsite mass spectrometer analysis. Samples are typically drawn from a sampling tap into a UF6 sample bottle, then packaged, sealed, and shipped under IAEA chain of custody to an offsite analytical laboratory. Future DA safeguard measures may require improvements in efficiency and effectiveness as GCEP capacities increase and UF6 shipping regulations become increasingly more restrictive. The Pacific Northwest National Laboratory (PNNL) DA sampler concept and Laser Ablation Absorption Ratio Spectrometry (LAARS) assay method are under development to potentially provide DA safeguard tools that increase inspection effectiveness and reduce sample shipping constraints. The PNNL DA sampler concept uses a handheld sampler to collect DA samples for either onsite LAARS assay or offsite laboratory analysis. The DA sampler design will use a small sampling planchet that is coated with an adsorptive film to collect controlled quantities of UF6 gas directly from a cylinder or process sampling tap. Development efforts are currently underway at PNNL to enhance LAARS assay performance to allow high-precision onsite bias defect measurements. In this paper, we report on the experimental investigation to develop adsorptive films for the PNNL DA sampler concept. These films are intended to efficiently capture UF6 and then stabilize the collected DA sample prior to onsite LAARS or offsite laboratory analysis. Several porous material composite films were investigated, including a film designed to maximize the chemical adsorption and binding of gaseous UF6 onto the sampling planchet.

destructive assay↗