Search NASA⌕ Search

SEARCH · Search NASA

Results for “Graphite Properties”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SEMI-EMPIRICAL MODELING OF IRRADIATION-INDUCED DIMENSIONAL CHANGE IN H-451 NUCLEAR GRAPHITE

Nuclear graphite has been used as a moderator material in nuclear reactor designs dating back to the first reactor to reach criticality, Chicago Pile 1, in 1942. In addition, it is anticipated to be used in the conceptual Generation four (GenIV) Molten-salt reactors (MSRs) and the High-temperature gas-cooled reactors (HTRs). The macroscopic dimensional change observed in irradiated nuclear graphite is a property change of significant importance. Largely, volumetric change provides valuable insight into the in-service lifetime of graphite components used in nuclear reactors. The dimensional change behavior varies amongst each grade of nuclear graphite due to processing techniques and the resulting microstructure. In this work, historic data for nuclear graphite H-451 is revisited. A semi-empirical methodology is proposed to describe the dimensional change behavior as a function of temperature for nuclear graphite H-451. The turnaround dose, or when there is a reversal of the dimensional change from contraction to expansion, is proposed to be a thermally activated process and thus can be described by an Arrhenius model. On the atomic scale, H-451 is sp2-bonded carbon atoms with some degree of disorder regardless of orientation. Towards that end, the activation energy is assumed to be a constant irrespective of orientation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Slides for MS&T2022: Carbon-Carbon Composites from 3D Printed Preforms Graphitized by Electric Field Assisted Sintering

Formation of Carbon-Carbon (C-C) composite materials requires putting a carbon fiber preform through a cycle of densification, carbonization, and graphitization. This cycle is then repeated until the desired properties are achieved. The graphitization phase is particularly energy demanding as it involves heating the components to in excess of 2000°C. In traditional furnaces this is also quite time consuming as typical heating rates are low, and the actual heat treatment may be limited by component dimensions, as heat is conducted throughout the part primarily by thermal diffusion. Joule heating by means of Electric Field Assisted Sintering (EFAS) systems enables high heating rates and causes the part to be heated from the inside, which eliminates the thermal diffusion time constraint. In our process, C-C composites are formed by pyrolyzation of 3D-printed carbon fiber preforms, vacuum infiltration of naphthalene based mesophase pitch, and carbonization. The part is then graphitized in the EFAS system. By this method graphitization of the composite matrix was achieved in less than an hour. A part density of greater than 1.6g/cc (up to 1.9g/cc demonstrated) was achieved after only two rounds of infiltration and a single graphitization. Overall the process took less than a week which is significantly faster than traditional methods. Optical microscopy and XRD results are discussed to elucidate the internal porosity and characterize the degree of graphitization. Testing was performed showing the impact on fiber direction to electrical and thermal properties of the final part.

36 MATERIALS SCIENCE↗

AGC-2 Graphite Preirradiation Data Analysis Report

This report describes the specimen loading order and documents all preirradiation examination material property measurement data for graphite specimens contained within the Second Advanced Graphite Capsule (AGC 2) irradiation capsule. The AGC 2 capsule is the second in six planned irradiation capsules comprising the Advanced Graphite Creep (AGC) test series. The AGC test series is used to irradiate graphite specimens in order to garner quantitative data necessary for predicting the irradiation behavior and operating performance of new nuclear grade graphites. This testing will ascertain the in service behavior of the graphite for pebble bed and prismatic very high temperature reactor designs. Similar to the First Advanced Graphite Capsule (AGC 1) preirradiation examination report, material property tests were conducted on specimens from 18 nuclear grade graphite types. However, AGC 2 tested an increased number of specimens (i.e., 512) prior to loading them into the AGC 2 irradiation assembly. All AGC 2 specimen testing was conducted at Idaho National Laboratory from July 2009 to August 2010. This report also details the specimen loading methodology for graphite specimens inside the AGC 2 irradiation capsule. The AGC 2 capsule design requires “matched pair” creep specimens that have similar dose levels above and below the neutron flux profile mid plane. This provides similar specimens with and without an applied load. Analysis in this document utilizes the neutron flux profile calculated for the AGC 2 capsule design, the capsule dimensions, and the size (i.e., length) of the selected graphite specimens to create a stacking order that produces “matched pairs” of graphite specimens above and below the AGC 2 capsule elevation mid point, thus providing specimens with similar neutron dose levels.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of graphite morphology on the tensile strength and thermal conductivity of cast iron

Highlights: • The graphite morphology is characterized from 3D structure using X–ray tomography. • The size, distribution, shape and interconnectivity of graphite are estimated. • The influences of graphite morphology on tensile properties and thermal conductivity are evaluated. • The mechanism of tensile strength and the model of thermal conductivity are discussed. - Abstract: Graphite morphology is a very important parameter affecting the properties of cast iron. In this study, the graphite morphology was characterized using both 3D and 2D structures. The experimental results revealed that when the graphite was less spheroidal, the graphite had greater interconnectivity in the 3D structure of the cast iron. The size, distribution, volume fraction, and shape of the graphite were estimated. Moreover, the influences of the graphite's morphology, size, and distribution on the tensile property and thermal conductivity at different temperatures were estimated. The experimental results revealed that with an increase in temperature, the thermal conductivity initially increased, and then decreased, whereas the tensile strength decreased slightly at first, and then decreased rapidly. In addition, with an increase in the percentage of compacted graphite, the tensile strength decreased and the thermal conductivity increased. The fracture surfaces of tensile specimens were also estimated. Finally, the mechanism of tensile strength and the model of thermal conductivity were investigated.

36 MATERIALS SCIENCE↗

Thermal properties of composites with bismaleimide-vinyl poly(styrylpyridine) blends

Thermal properties, flammability, and selected mechanical properties of eight different graphite composite panels fabricated using four different resin matrices and two types of graphite reinforcement were investigated and compared with the properties of an epoxy composite, MXB 7203. The resin matrices included XU71775/H795, a blend of vinyl poly(styrylpyridine) and bismaleimide; H795, a bismaleimide; Cycom 6162, a phenolic; and PSP 6022M, a poly(styrylpyridine). The graphite fiber was AS-4 used in the form of tape or fabric. It was found that the XU71775/H795 blend with the graphite tape was the optimum design giving the lowest heat release rate, while the control epoxy panel exhibited the highest total heat release and heat release rates, highest smoke and CO evolution, highest mass losses, and lowest oxygen index of all the composites tested.

Kourtides, D. A.↗

Effect of graphite nanoplatelets and carbon nanofibers on rheology, hydration, shrinkage, mechanical properties, and microstructure of UHPC

This study evaluates the effects of two types of graphite nanoplatelet (GNP-C and GNP-M) and one type of carbon nanofiber (CNF) on rheological properties, hydration kinetics, autogenous shrinkage, and pore structure of ultra-high-performance concrete (UHPC). The dispersion method was optimized to secure uniform dispersion of the nanomaterials in the UHPC. The plastic viscosity decreased with the nanomaterials content as the content was increased from 0 to 0.05%. As the nanomaterials content increased from 0 to 0.3%, the duration of induction period was extended by the addition of CNF, but shortened by use of GNP-C or GNP-M; cumulative hydration heat release was increased by introduction of nanomaterials; the autogenous shrinkage of UHPC with CNF, GNP-C, and GNP-M was increased by 30%, 20%, and 20%, respectively. The use of 0.3% CNFs reduced the total porosity of the UHPC by approximately 35%, indicating that the presence of CNFs refined the microstructure of UHPC.

36 MATERIALS SCIENCE↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites are discussed. In particular, the types of weaves and the resin contents were chosen for comparison. The types of weaves selected are plain weave, satin weave, and tridirectional weave. The composites made of the fabrics are compared to composites made from unidirectional tapes under static and fatigue loading. During static loading, acoustic emission events were monitored. Also, examinations of fracture surfaces and polished sections both away from the fracture surface, and of virgin specimens under an electron microscope are discussed.

Hanagud, S.↗

Comparative evaluation of woven graphite-epoxy composites

A comparative evaluation of some of the mechanical properties of woven graphite-epoxy composites have been discussed in this report. In particular the types of weaves and the resin contents have been chosen for comparison. The types of weaves selected are plain weaves, satin weave and tri-directional weave. The composites made of these fabrics have been compared to composites made from unidirectional tapes under static and fatigue loading. During static loading acoustic emission events have been monitored. Also, examinations of fracture surface and polished sections of specimens away from the fracture surface under an electron microscope have been discussed.

Hanagud, S.↗

The properties of novel bisimide amine cured epoxy/Celion 6000 graphite fiber composites

The study is concerned with the further development of bisimide amine cured epoxy resins first reported by Serafini et al. (1979). Attention is given to properties of the neat resins and composites made with these novel epoxy resins and Celion 6000 graphite fibers. The use of bisimide amine hardeners to cure epoxy resins causes a significant improvement in the char-forming characteristics of the cured resin. Compared to epoxy resins cured with a conventional amine, such as 4,4'-diaminodiphenylsulfone, the bisimide cured epoxies exhibit about a twofold improvement in the aerobic char yield at 800 C. The levels of moisture absorption exhibited by the bisimide amine cured epoxies were found to be considerably lower than those exhibited by state-of-the-art epoxies (0.5 wt.% versus 2.0%).

Scola, D. A.↗

Comparison between the Strength Levels of Baseline Nuclear-Grade Graphite and Graphite Irradiated in AGC-2

This report details the initial comparison of mechanical strength properties between the cylindrical nuclear-grade graphite specimens irradiated in the second Advanced Graphite Creep (AGC-2) experiment with the established baseline, or unirradiated, mechanical properties compiled in the Baseline Graphite Characterization program. The overall comparative analysis will describe the development of an appropriate test protocol for irradiated specimens, the execution of the mechanical tests on the AGC-2 sample population, and will further discuss the data in terms of developing an accurate irradiated property distribution in the limited amount of irradiated data by leveraging the considerably larger property datasets being captured in the Baseline Graphite Characterization program. Integrating information on the inherent variability in nuclear-grade graphite with more complete datasets is one of the goals of the VHTR Graphite Materials program. Between “sister” specimens, or specimens with the same geometry machined from the same sub-block of graphite from which the irradiated AGC specimens were extracted, and the Baseline datasets, a comprehensive body of data will exist that can provide both a direct and indirect indication of the full irradiated property distributions that can be expected of irradiated nuclear-grade graphite while in service in a VHTR system. While the most critical data will remain the actual irradiated property measurements, expansion of this data into accurate distributions based on the inherent variability in graphite properties will be a crucial step in qualifying graphite for nuclear use as a structural material in a VHTR environment.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Research on graphite reinforced glass matrix composites

A composite that can be used at temperatures up to 875 K with mechanical properties equal or superior to graphite fiber reinforced epoxy composites is presented. The composite system consist of graphite fiber, uniaxially or biaxially, reinforced borosilicate glass. The mechanical and thermal properties of such a graphite fiber reinforced glass composite are described, and the system is shown to offer promise as a high performance structural material. Specific properties that were measured were: a modified borosilicate glass uniaxially reinforced by Hercules HMS graphite fiber has a three-point flexural strength of 1030 MPa, a four-point flexural strength of 964 MPa, an elastic modulus of 199 GPa and a failure strain of 0.0052. The preparation and properties of similar composites with Hercules HTS, Celanese DG-102, Thornel 300 and Thornel Pitch graphite fibers are also described.

Bacon, J. F.↗

Mechanical Property Characterization of F-100/934 Graphite-Epoxy Composite Material

Procedures for quality control, fabrication techniques, specimen machining, test methodologies, and data collection and interpretation were defined using Thornel P-100 carbon fiber combined with Fiberite's 934 epoxy resin in unidirectional tape form. Tests on the prepreg material, including gel time, resin solids content, tack, volatile content, and flow are detailed. The steps of the fabrication and machining processes are described. Both destructive and nondestructive techniques were employed to assess the properties of the cured laminates. Tests to determine tensile strength and modulus, compressive strength and modulus, interlaminar and inplane shear strength, and flexural strength and modulus are discussed. The results of these experiments are compared with data generated by other researchers.

Clinton, R. G., Jr.↗

Improved oxidation-resistant carbon and graphite materials

A variety of silicon-carbide treated carbon and graphite products were prepared, and oxidation and strength properties determined. Carbon and graphite materials used in the preliminary study include fiber, tape, felt, foam, bulk, and laminar configurations. The silicon-carbide treatment used in preparing the oxidation resistant specimens employs either vacuum or ultrasonic impregnation of various silicone-silicon mixtures into the matrix material. The impregnation phase is followed by controlled thermal reaction at which time the silicon carbide is synthesized and takes the form of an integral protective boundary layer. Thickness of the layer ranges from a fraction of a mil to 10 mils, depending on the matrix material and processing parameters. Oxidation resistance of all the silicon-carbide-treated specimens investigated was found to be significantly improved. Mechanical strengths of the laminar composites were also found to be somewhat improved. At room temperature the specific strength of the silicon-carbide treated fibers and tapes was degraded to some extent; however, their relative strengths were significantly increased at elevated temperatures in oxidizing atmosphere.

Muir, H. M.↗

Use of the short-beam shear test for quality control of graphite-polyimide laminates

The properties of laminated composite materials are strongly affected by many fabrication variables including temperature, time, and molding pressure. It is therefore necessary to have reliable quality control tests to check the properties of manufactured materials. The short-beam shear test is used widely by both manufacturers and researchers as a quality control test in the production of materials and development of new material systems. There are, however, several limitations to the standard test method. This paper presents the results of short-beam shear tests on graphite-polyimide laminates and reports on stiffness-strength relationships and nondestructive evaluation methods which aid in the interpretation of the test data.

Stinchcomb, W. W.↗

Electrical, thermal, and mechanical properties of spatially tailored fiber orientations in 3D printed carbon-carbon composites for EFAS/SPS

Using C-C synthesized at INL from continuous fiber 3D printed preforms, tooling was fabricated, tested, and compared to graphite. The anisotropic properties of the C-C material were leveraged to make stronger and more energy efficient tooling. Future work involves tailoring the fiber orientations to create targeted heating zones and thermal gradients.

36 MATERIALS SCIENCE↗

PCEA Baseline Characterization: Billet XCP01S8 11 Compressive, Tensile, and Flexure Strengths

Grade PCEA graphite is one of several grades being considered for the core structures of the Next Generation Nuclear Plant (NGNP). An experimental program is underway to describe the statistical nature of the mechanical properties of PCEA graphite, information needed to support the design of graphite components and licensing of the NGNP. It will be necessary to characterize several billets from various lots or batches. The exact number of billets will depend on the observed variability in properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interlaminar fracture toughness of thermoplastic composites

Edge delamination tension and double cantilever beam tests were used to characterize the interlaminar fracture toughness of continuous graphite-fiber composites made from experimental thermoplastic polyimides and a model thermoplastic. Residual thermal stresses, known to be significant in materials processed at high temperatures, were included in the edge delamination calculations. In the model thermoplastic system (polycarbonate matrix), surface properties of the graphite fiber were shown to be significant. Critical strain energy release rates for two different fibers having similar nominal tensile properties differed by 30 to 60 percent. The reason for the difference is not clear. Interlaminar toughness values for the thermoplastic polyimide composites (LARC-TPI and polyimidesulfone) were 3 to 4 in-lb/sq in. Scanning electron micrographs of the EDT fracture surfaces suggest poor fiber/matrix bonding. Residual thermal stresses account for up to 32 percent of the strain energy release in composites made from these high-temperature resins.

Hinkley, J. A.↗

Interlaminar fracture toughness of thermoplastic composites

Edge delamination tension and double cantilever beam tests were used to characterize the interlaminar fracture toughness of continuous graphite-fiber composites made from experimental thermoplastic polyimides and a model thermoplastic. Residual thermal stresses, known to be significant in materials processed at high temperatures, were included in the edge delamination calculations. In the model thermoplastic system (polycarbonate matrix), surface properties of the graphite fiber were shown to be significant. Cricital strain energy release rates for two different fibers having similar nominal tensile properties differed by 30 to 60 percent. The reason for the difference is not clear. Interlaminar toughness values for the thermoplastic polyimide composites (LARC-TPI and polyimidesulfone) were 3 to 4 in-lb/sq in. Scanning electron micrographs of the EDT fracture surfaces suggest poor fiber/matrix bonding. Residual thermal stresses account for up to 32 percent of the strain energy release in composites made from these high-temperature resins.

Hinkley, Jeffrey A.↗