Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Microgravity changes in heart structure and cyclic-AMP metabolism

The effects of microgravity on cardiac ultrastructure and cyclic AMP metabolism in tissues of rats flown on Spacelab 3 are reported. Light and electron microscope studies of cell structure, measurements of low and high Km phosphodiesterase activity, cyclic AMP-dependent protein kinase activity, and regulatory subunit compartmentation show significant deviations in flight animals when compared to ground controls. The results indicate that some changes have occurred in cellular responses associated with catecholamine receptor interactions and intracellular signal processing.

Philpott, D. E.↗

The effects of normal and therapeutic baths on the central vascular organs of persons with healthy hearts, as measured by X-ray

According to current information, baths have a four-fold effect on the circulation: (1) Dilation or constriction is produced in the area of the blood vessels in the skin as a result of thermal, chemical or mechanical stimuli; (2) This reaction in the dermal vascular system produces a further effect on the central vessels in the extremities, the area of the splanchnicus, and other body cavities; (3) The reflect transposition of other organ systems, i.e., the respiratory organs, has a reaction on the circulation; and (4) The water pressure of the bath has a hydrostatic effect, i.e., on the one hand it empties peripheral veins more rapidly, and on the other it increases the intra-abdominal pressure and this reduces once again the circulation in the area of the splanchnicus.

Boehm, G.↗

Near-infrared mass-to-light ratios in galaxies - Stellar mass and star formation in the heart of the Whirlpool

The observed stellar population in the solar neighborhood is used to derive a relationship between the local stellar mass density and the visual and near-IR brightness, which is then extended to a wide range of galaxies. This technique is applied to near-IR (J, H, and K) images of the central 2.3 kpc (50 arcsec) of the Whirlpool Galaxy (M51, NGC 5194). It is estimated that the current high rate of star formation can last no more than about another 10-million years, and that, if a large fraction of the stars in the nucleus of M51 was created in periods of enhanced formation, the duty cycle for such events is about 5 percent.

Thronson, Harley A., Jr.↗

Incompressible viscous flow computations for the pump components and the artificial heart

A finite difference, three dimensional incompressible Navier-Stokes formulation to calculate the flow through turbopump components is utilized. The solution method is based on the pseudo compressibility approach and uses an implicit upwind differencing scheme together with the Gauss-Seidel line relaxation method. Both steady and unsteady flow calculations can be performed using the current algorithm. Here, equations are solved in steadily rotating reference frames by using the steady state formulation in order to simulate the flow through a turbopump inducer. Eddy viscosity is computed by using an algebraic mixing-length turbulence model. Numerical results are compared with experimental measurements and a good agreement is found between the two.

Kiris, Cetin↗

Arrays: The heart and soul of SIRTF

This pape describes the status of NASA's Space Infrared Telescope Facility (SIRTF) program. SIRTF will be a cryogenically cooled observatory for infrared astronomy from space and is planned for launch early in the next decade. It will be the first cryogenic space observatory to make extensive use of the powerful infrared detector array technology discussed at this conference. We summarize a newly developed SIRTF mission concept and show how the availability of detector arrays has shaped the scientific rationale for SIRTF, and how the arrays themselves have become part of the definition of the SIRTF mission.

Werner, Michael W.↗

Responses of heart rate and blood pressure to KC-135 hyper-gravity

Many investigators have clarified the effects of hyper gravitational-inertial forces (G) upon the cardiovascular system, using the centrifugal apparatus with short rotating radius. We investigated the cardiovascular responses to KC-135 hyper-G flight with negligibly small angular velocity. Six normal, healthy subjects 29 to 40 years old (5 males and 1 female) took part in this experiment. Hyper gravitational-inertial force was generated by the KC-135 hyper-G flight, flown in a spiral path with a very long radius of 1.5 miles. Hyper-G was sustained for 3 minutes with 1.8 +Gz in each session and was repeatedly exposed to very subject sitting on a chair 5 times. The preliminary results of blood pressure and R-R interval are discussed. An exposure of 1.8 +Gz stress resulted in a remarkable increase of systolic and diastolic blood pressure, while the pulse pressure did not change and remained equal to the control level regardless of an exposure of hyper-G. These results in blood pressure indicate an increase of resistance in the peripheral vessels, when an exposure of hyper-G was applied. The R-R interval was calculated from ECG. R-R interval in all subjects was changed but not systematically, and R-R interval became obviously shorter during the hyper-G period than during the 1 +Gz control period although R-R interval varied widely in some cases. The coefficient of variation of R-R interval was estimated to determine the autonomic nerve activity, but no significant change was detectable.

Satake, Hirotaka↗

Neonatal rat heart cells cultured in simulated microgravity

In vitro characteristics of cardiac cells cultured in simulated microgravity are reported. Tissue culture methods performed at unit gravity constrain cells to propagate, differentiate, and interact in a two dimensional (2D) plane. Neonatal rat cardiac cells in 2D culture organize predominantly as bundles of cardiomyocytes with the intervening areas filled by non-myocyte cell types. Such cardiac cell cultures respond predictably to the addition of exogenous compounds, and in many ways they represent an excellent in vitro model system. The gravity-induced 2D organization of the cells, however, does not accurately reflect the distribution of cells in the intact tissue. We have begun characterizations of a three-dimensional (3D) culturing system designed to mimic microgravity. The NASA designed High-Aspect-Ratio-Vessel (HARV) bioreactors provide a low shear environment which allows cells to be cultured in static suspension. HARV-3D cultures were prepared on microcarrier beads and compared to control-2D cultures using a combination of microscopic and biochemical techniques. Both systems were uniformly inoculated and medium exchanged at standard intervals. Cells in control cultures adhered to the polystyrene surface of the tissue culture dishes and exhibited typical 2D organization. Cells in cultured in HARV's adhered to microcarrier beads, the beads aggregated into defined clusters containing 8 to 15 beads per cluster, and the clusters exhibited distinct 3D layers: myocytes and fibroblasts appeared attached to the surfaces of beads and were overlaid by an outer cell type. In addition, cultures prepared in HARV's using alternative support matrices also displayed morphological formations not seen in control cultures. Generally, the cells prepared in HARV and control cultures were similar, however, the dramatic alterations in 3D organization recommend the HARV as an ideal vessel for the generation of tissue-like organizations of cardiac cells in simulated microgravity.

Akins, Robert E.↗

Product Structure, the Heart of Product Definition

This paper describes the LMMSS Product Definition System (PDS) philosophy and approach were the use of each item parts document or software can be traced to a specific end item (EI) serial/tail number of the product. It explains why a part-oriented approach to data organization and configuration management is required. The definition of part-oriented is that all appropriate product definition data products will be collected. Referenced and managed by their linkage/relationship to parts/items, The paper will touch upon how LMMSS store/controls product definition information under each project's top product designator in a two tiered approach. One tier for each product end item and another tier which contain/controls listings of drawings, documents. Specifications and standards that are required for hardware item definition.

DeHoog, C., Jr.↗

Heart Fibrillation and Parallel Supercomputers

The Luo and Rudy 3 cardiac cell mathematical model is implemented on the parallel supercomputer CRAY - T3D. The splitting algorithm combined with variable time step and an explicit method of integration provide reasonable solution times and almost perfect scaling for rectilinear wave propagation. The computer simulation makes it possible to observe new phenomena: the break-up of spiral waves caused by intracellular calcium and dynamics and the non-uniformity of the calcium distribution in space during the onset of the spiral wave.

Kogan, B. Y.↗

Evaluating the Ability of Heart Rate and EEG to Control Alertness during Performance

The major focus of the present proposal was to examine psychophysiological indices that show promise for invoking different modes of automation in an adaptive automation system. With the increased use of automation in today's work environment, people's roles in the work place are being redefined from that of active participant to one of passive monitor. Although the introduction of automated systems has a number of benefits, there are also a number of disadvantages regarding worker performance. Byrne and Parasuraman have argued for the use of psychophysiological measures in the development and the implementation of adaptive automation. While performance based, model based, and psychophysiologically based adaptive automation systems have been studied, the combined use of several psychophysiological measures has never been investigated. Such a combination provides the advantage of real time evaluation of the state of the subject in two relevant dimensions and offers a more realistic approach to the implementation of adaptive automation compared to the use of either dimension by itself.

Freeman, Fred↗

Heart Sonar Images

Stanford University cardiologists, with the help of Ames engineers, have validated the operation of the echo-cardioscope to monitor cardiac functions of astronauts in flight. This device forms images of internal structures using high-frequency sound. The instrument is compact, lightweight, portable, and DC powered for safety. The battery powered ultrasonic device, being isolated from its electrical environment, has an inherent safety advantage especially with infants.

Source record↗

Contractile reserve and intracellular calcium regulation in mouse myocytes from normal and hypertrophied failing hearts

Mouse myocyte contractility and the changes induced by pressure overload are not fully understood. We studied contractile reserve in isolated left ventricular myocytes from mice with ascending aortic stenosis (AS) during compensatory hypertrophy (4-week AS) and the later stage of early failure (7-week AS) and from control mice. Myocyte contraction and [Ca(2+)](i) transients with fluo-3 were measured simultaneously. At baseline (0.5 Hz, 1.5 mmol/L [Ca(2+)](o), 25 degrees C), the amplitude of myocyte shortening and peak-systolic [Ca(2+)](i) in 7-week AS were not different from those of controls, whereas contraction, relaxation, and the decline of [Ca(2+)](i) transients were slower. In response to the challenge of high [Ca(2+)](o), fractional cell shortening was severely depressed with reduced peak-systolic [Ca(2+)](i) in 7-week AS compared with controls. In response to rapid pacing stimulation, cell shortening and peak-systolic [Ca(2+)](i) increased in controls, but this response was depressed in 7-week AS. In contrast, the responses to both challenge with high [Ca(2+)](o) and rapid pacing in 4-week AS were similar to those of controls. Although protein levels of Na(+)-Ca(2+) exchanger were increased in both 4-week and 7-week AS, the ratio of SR Ca(2+)-ATPase to phospholamban protein levels was depressed in 7-week AS compared with controls but not in 4-week AS. This was associated with an impaired capacity to increase sarcoplasmic reticulum Ca(2+) load during high work states in 7-week AS myocytes. In hypertrophied failing mouse myocytes, depressed contractile reserve is related to an impaired augmentation of systolic [Ca(2+)](i) and SR Ca(2+) load and simulates findings in human failing myocytes.

Non-NASA Center↗

Neonatal rat heart cells cultured in simulated microgravity

In vitro characteristics of cardiac cells cultured in simulated microgravity are reported. Tissue culture methods performed at unit gravity constrain cells to propagate, differentiate, and interact in a two-dimensional (2D) plane. Neonatal rat cardiac cells in 2D culture organize predominantly as bundles of cardiomyocytes with the intervening areas filled by nonmyocyte cell types. Such cardiac cell cultures respond predictably to the addition of exogenous compounds, and in many ways they represent an excellent in vitro model system. The gravity-induced 2D organization of the cells, however, does not accurately reflect the distribution of cells in the intact tissue. We have begun characterizations of a three-dimensional (3D) culturing system designed to mimic microgravity. The NASA-designed High-Aspect Ratio Vessel (HARV) bioreactors provide a low shear environment that allows cells to be cultured in static suspension. HARV-3D cultures were prepared on microcarrier beads and compared to control-2D cultures using a combination of microscopic and biochemical techniques. Both systems were uniformly inoculated and medium exchanged at standard intervals. Cells in control cultures adhered to the polystyrene surface of the tissue culture dishes and exhibited typical 2D organization. Cells cultured in HARVs adhered to microcarrier beads, the beads aggregated into defined clusters containing 8 to 15 beads per cluster, and the clusters exhibited distinct 3D layers: myocytes and fibroblasts appeared attached to the surfaces of beads and were overlaid by an outer cell type. In addition, cultures prepared in HARVs using alternative support matrices also displayed morphological formations not seen in control cultures. Generally, the cells prepared in HARV and control cultures were similar; however, the dramatic alterations in 3D organization recommend the HARV as an ideal vessel for the generation of tissuelike organization of cardiac cells in vitro.

Non-NASA Center↗

Structural characterization and regulatory element analysis of the heart isoform of cytochrome c oxidase VIa

In order to investigate the mechanism(s) governing the striated muscle-specific expression of cytochrome c oxidase VIaH we have characterized the murine gene and analyzed its transcriptional regulatory elements in skeletal myogenic cell lines. The gene is single copy, spans 689 base pairs (bp), and is comprised of three exons. The 5'-ends of transcripts from the gene are heterogeneous, but the most abundant transcript includes a 5'-untranslated region of 30 nucleotides. When fused to the luciferase reporter gene, the 3.5-kilobase 5'-flanking region of the gene directed the expression of the heterologous protein selectively in differentiated Sol8 cells and transgenic mice, recapitulating the pattern of expression of the endogenous gene. Deletion analysis identified a 300-bp fragment sufficient to direct the myotube-specific expression of luciferase in Sol8 cells. The region lacks an apparent TATA element, and sequence motifs predicted to bind NRF-1, NRF-2, ox-box, or PPAR factors known to regulate other nuclear genes encoding mitochondrial proteins are not evident. Mutational analysis, however, identified two cis-elements necessary for the high level expression of the reporter protein: a MEF2 consensus element at -90 to -81 bp and an E-box element at -147 to -142 bp. Additional E-box motifs at closely located positions were mutated without loss of transcriptional activity. The dependence of transcriptional activation of cytochrome c oxidase VIaH on cis-elements similar to those found in contractile protein genes suggests that the striated muscle-specific expression is coregulated by mechanisms that control the lineage-specific expression of several contractile and cytosolic proteins.

Non-NASA Center↗

Exposing the Binary Heart of ETA Carinae

Continued progress was made last year on A1367. As noted before, A1367 is a puzzling cluster with a large elongation, suggesting a major merger but with an anti-correlation between the luminosity and temperature of the two components of the cluster (NE and SW). The less luminous subconcentration appears hotter and the more luminous portion of the cluster appears cooler in contradiction to the well-established positive correlation of temperature and luminosity for clusters and groups. With the XMM-Newton observation we have developed a merger model to explain this apparent contradiction.

Forman, WIlliam↗

Construction of a Resting High Fidelity ECG "SuperScore" for Management and Screening of Heart Disease

Resting conventional ECG is notoriously insensitive for detecting coronary artery disease (CAD) and only nominally useful in screening for cardiomyopathy (CM). Similarly, conventional exercise stress test ECG is both time- and labor-consuming and its accuracy in identifying CAD is suboptimal for use in population screening. We retrospectively investigated the accuracy of several advanced resting electrocardiographic (ECG) parameters, both alone and in combination, for detecting CAD and cardiomyopathy (CM).

Schlegel, Todd T.↗

Voyage ot the Heart of a Comet

Comets occasionally give a dazzling light displays in the night sky, but they may also help us to understand the chemical processes that led to our existence on Earth.

comets planetary orbits space technology↗