Search NASA⌕ Search

SEARCH · Search NASA

Results for “HEART FUNCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Prediction of thrombus-related mechanical prosthetic valve dysfunction using transesophageal echocardiography

Identification of thrombus-related mechanical prosthetic valve dysfunction (MPVD) has important therapeutic implications. We sought to develop an algorithm, combining clinical and echocardiographic parameters, for prediction of thrombus-related MPVD in a series of 53 patients (24 men, age 52 +/- 16 years) who had intraoperative diagnosis of thrombus or pannus from 1992 to 1997. Clinical and echocardiographic parameters were analyzed to identify predictors of thrombus and pannus. Prevalence of thrombus and diagnostic yields relative to the number of predictors were determined. There were 22 patients with thrombus, 19 patients with pannus, and 12 patients with both. Forty-two of 53 masses were visualized using transesophageal echocardiography (TEE), including 29 of 34 thrombi or both thrombi and panni and 13 of 19 isolated panni. Predictors of thrombus or mixed presentation include mobile mass (p = 0.009), attachment to occluder (p = 0.02), elevated gradients (p = 0.04), and an international normalized ratio of < or = 2.5 (p = 0.03). All 34 patients with thrombus or mixed presentation had > or = 1 predictor. The prevalence of thrombus in the presence of < or = 1, 2, and > or = 3 predictors is 14%, 69%, and 91%, respectively. Thus, TEE is sensitive in the identification of abnormal mass in the setting of MPVD. An algorithm based on clinical and transesophageal echocardiographic predictors may be useful to estimate the likelihood of thrombus in the setting of MPVD. In the presence of > or = 3 predictors, the probability of thrombus is high.

NASA Discipline Cardiopulmonary↗

Initial clinical experience of real-time three-dimensional echocardiography in patients with ischemic and idiopathic dilated cardiomyopathy

The geometry of the left ventricle in patients with cardiomyopathy is often sub-optimal for 2-dimensional ultrasound when assessing left ventricular (LV) function and localized abnormalities such as a ventricular aneurysm. The aim of this study was to report the initial experience of real-time 3-D echocardiography for evaluating patients with cardiomyopathy. A total of 34 patients were evaluated with the real-time 3D method in the operating room (n = 15) and in the echocardiographic laboratory (n = 19). Thirteen of 28 patients with cardiomyopathy and 6 other subjects with normal LV function were evaluated by both real-time 3-D echocardiography and magnetic resonance imaging (MRI) for obtaining LV volumes and ejection fractions for comparison. There were close relations and agreements for LV volumes (r = 0.98, p <0.0001, mean difference = -15 +/- 81 ml) and ejection fractions (r = 0.97, p <0.0001, mean difference = 0.001 +/- 0.04) between the real-time 3D method and MRI when 3 cardiomyopathy cases with marked LV dilatation (LV end-diastolic volume >450 ml by MRI) were excluded. In these 3 patients, 3D echocardiography significantly underestimated the LV volumes due to difficulties with imaging the entire LV in a 60 degrees x 60 degrees pyramidal volume. The new real-time 3D echocardiography is feasible in patients with cardiomyopathy and may provide a faster and lower cost alternative to MRI for evaluating cardiac function in patients.

NASA Discipline Cardiopulmonary↗

Effect of age and gender on sudomotor and cardiovagal function and blood pressure response to tilt in normal subjects

Normative data are limited on autonomic function tests, especially beyond age 60 years. We therefore evaluated these tests in a total of 557 normal subjects evenly distributed by age and gender from 10 to 83 years. Heart rate (HR) response to deep breathing fell with increasing age. Valsalva ratio varied with both age and gender. QSART (quantitative sudomotor axon-reflex test) volume was consistently greater in men (approximately double) and progressively declined with age for all three lower extremity sites but not the forearm site. Orthostatic blood pressure reduction was greater with increasing age. HR at rest was significantly higher in women, and the increment with head-up tilt fell with increasing age. For no tests did we find a regression to zero, and some tests seem to level off with increasing age, indicating that diagnosis of autonomic failure was possible to over 80 years of age.

Non-NASA Center↗

A time dependent anatomically detailed model of cardiac conduction

In order to understand the determinants of transitions in cardiac electrical activity from normal patterns to dysrhythmias such as ventricular fibrillation, we are constructing an anatomically and physiologically detailed finite element simulation of myocardial electrical propagation. A healthy human heart embedded in paraffin was sectioned to provide a detailed anatomical substrate for model calculations. The simulation of propagation includes anisotropy in conduction velocity due to fiber orientation as well as gradients in conduction velocities, absolute and relative refractory periods, action potential duration and electrotonic influence of nearest neighbors. The model also includes changes in the behaviour of myocardial tissue as a function of the past local activity. With this model, we can examine the significance of fiber orientation and time dependence of local propagation parameters on dysrhythmogenesis.

Computer Simulation↗

Comparison of cardiovascular function during the early hours of bed rest and space flight

This paper reviews the cardiovascular responses of six healthy male subjects to 6 hours in a 5 degrees head-down bed rest model of weightlessness, and compares these responses to those obtained when subjects were positioned in head-up tilts of 10 degrees, 20 degrees, and 42 degrees, simulating 1/6, 1/3, and 2/3 G, respectively. Thoracic fluid index, cardiac output, stroke volume, and peak flow were measured using impedance cardiography. Cardiac dimensions and volumes were determined from two-dimensional guided M-mode echocardiograms in the left lateral decubitus position at 0, 2, 4, and 6 hours. Cardiovascular response to a stand test were compared before and after bed rest. The impedance values were related to tilt angle for the first 2 hours of tilt; however, after 3 hours, at all four angles, values began to converge, indicating that cardiovascular homeostatic mechanisms seek a common adapted state, regardless of effective gravity level (tilt angle) up to 2/3 G. Echocardiography revealed that left ventricular end-diastolic and end-systolic volume, stroke volume, ejection fraction, heart rate, and cardiac output had returned to control values by hour 6 for all tilt angles. The lack of a significant immediate change in left ventricular end-diastolic volume, despite decrements in stroke volume (P < .05) and heart rate (not significant), indicates that multiple factors may play a role in the adaptation to simulated hypogravity. The echocardiography data indicated that no angle of tilt, whether head-down or head-up for 4 to 6 hours, mimicked exactly the changes in cardiovascular function recorded after 4 to 6 hours of space flight. Changes in left ventricular end-diastolic volume during space flight and tilt may be similar, but follow a different time course. Nevertheless, head-down tilt at 5 degrees for 6 hours mimics some (stroke volume, systolic and diastolic blood pressure, mean arterial blood pressure, and total resistance), but not all, of the changes occurring in an equivalent time of space flight. The magnitude of the change in the mean heart rate response to standing was greater after six hours of tilt at -5 degrees or 10 degrees. Thus, results from the stand test after 6 hours of bed rest at -5 degrees and 10 degrees, but not at 20 degrees or 42 degrees, are similar to those obtained after space flight.

Space Flight↗

Acute Total and Chronic Partial Sleep Deprivation: Effects on Neurobehavioral Functions, Waking EEG and Renin-Angiotensin System

Total sleep deprivation leads to decrements in neurobehavioral performance and changes in electroencephalographic (EEG) oscillations as well as the incidence of slow eye movements ad detected in the electro-oculogram (EOG) during wakefulness. Although total sleep deprivation is a powerful tool to investigate the association of EEG/EOG and neurobehavioral decrements, sleep loss during space flight is usual only partial. Furthermore exposure to the microgravity environment leads to changes in sodium and volume homeostasis and associated renal and cardio-endocrine responses. Some of these changes can be induced in head down tilt bedrest studies. We integrate research tools and research projects to enhance the fidelity of the simulated conditions of space flight which are characterized by complexity and mutual interactions. The effectiveness of countermeasures and physiologic mechanisms underlying neurobehavioral changes and renal-cardio endocrine changes are investigated in Project 3 of the Human Performance Team and Project 3 of the Cardiovascular Alterations Team respectively. Although the. specific aims of these two projects are very different, they employ very similar research protocols. Thus, both projects investigate the effects of posture/bedrest and sleep deprivation (total or partial) on outcome measures relevant to their specific aims. The main aim of this enhancement grant is to exploit the similarities in research protocols by including the assessment of outcome variables relevant to the Renal-Cardio project in the research protocol of Project 3 of the Human Performance Team and by including the assessment of outcome variables relevant to the Quantitative EEG and Sleep Deprivation Project in the research protocols of Project 3 of the Cardiovascular Alterations team. In particular we will assess Neurobehavioral Function and Waking EEG in the research protocols of the renal-cardio endocrine project and renin-angiotensin and cardiac function in the research protocol of the Quantitative EEG and Waking Neurobehavioral Function project. This will allow us to investigate two additional specific aims: 1) Test the hypothesis that chronic partial sleep deprivation during a 17 day bed rest experiment results in deterioration of neurobehavioral function during waking and increases in EEG power density in the theta frequencies, especially in frontal areas of the brain, as well as the nonREM- REM cycle dependent modulation of heart-rate variability. 2) Test the hypothesis that acute total sleep deprivation modifies the circadian rhythm of the renin-angiotensin system, changes the acute responsiveness of this system to posture beyond what a microgravity environment alone does and affects the nonREM-REM cycle dependent modulation of heart-rate variability.

Dijk, Derk-Jan↗

A Preliminary Assessment of Physical Demand During Simulated Lunar Surface Extravehicular Activities

Future Artemis missions will require more advanced spacesuits to support exploration and science activities on the Lunar surface. Preparing for these missions requires an understanding of the physical and cognitive demand of performing common surface extravehicular activity (EVA) tasks in a suited partial-gravity environment. This study aims to characterize physical demand during exploration EVA tasks in the Artificial Gravity Offload System (ARGOS) as a function of the task and operational environment itself. Two subjects completed two days of EVA simulations at ARGOS in the Mark III spacesuit offloaded to Lunar gravity (1/6G). Metabolic rate (MR) and heart rate (HR) were continuously recorded while subjects completed an end-to-end EVA as well as standalone tasks. Understanding the physical demand to complete exploration EVA tasks will be instrumental to the future success of exploration spacesuit designs and missions. Further work in this study will be needed to characterize MR during exploration EVA tasks, including expanding the subject pool and testing new suit designs.

Taylor E Schlotman↗

Treatment of hypertension with perindopril reduces plasma atrial natriuretic peptide levels, left ventricular mass, and improves echocardiographic parameters of diastolic function

BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.

NASA Program Biomedical Research and Countermeasur↗

Development of medical electronic devices in the APL space department

Several electronic devices for automatically correcting specific defects in a body's physiologic regulation and allowing approximately normal functioning are described. A self-injurious behavior inhibiting system (SIBIS) is fastened to the arm of a person with chronic self-injurious behavior patterns. An electric shock is delivered into the arm whenever the device senses above-threshold acceleration of the head such as occur with head-bangers. Sounding a buzzer tone with the shock eventually allows transference of the aversive stimulus to the buzzer so shocks are no longer necessary. A programmable implantable medication system features a solenoid pump placed beneath the skin and refueled by hypodermic needle. The pump functions are programmable and can deliver insulin, chemotherapy mixes and/or pain killers according to a preset schedule or on patient demand. Finally, an automatic implantible defibrillator has four electrodes attached directly to the heart for sensing electrical impulses or emitting them in response to cardiac fibrillation.

Newman, A. L.↗

Role of physical countermaneuvers in the management of orthostatic hypotension: efficacy and biofeedback augmentation

OBJECTIVE: To evaluate the efficacy of various physical countermaneuvers in reducing orthostatic hypotension and its associated symptoms and to assess the efficacy of biofeedback training in enhancing the effectiveness of physical countermaneuvers. MATERIAL AND METHODS: In nine study subjects with neurogenic orthostatic hypotension, four training sessions on physical countermaneuvers were performed after tilt-up, three with visual feedback on the effect of physical countermaneuvers on blood pressure and other cardiovascular variables. Blood pressure change and orthostatic symptoms during tilt-up were determined, as were the changes in total peripheral resistance, stroke index, and heart rate. RESULTS: The five female and four male patients had a mean age of 53 years and a mean duration of symptoms of 4.2 years. On an orthostatic symptom scale of 0 to 10, these patients had a mean symptom score of 7.3. The increment in systolic blood pressure was better for some maneuvers (such as leg crossing and a combination) than others (such as neck flexion and abdominal contraction). Three patterns of responses to biofeedback were found. Simple maneuvers such as squatting did not improve with training; visual feedback was needed for maneuvers such as thigh contraction, and performance declined without biofeedback; the third pattern, seen in maneuvers such as leg crossing, showed continued improvement with training, even without biofeedback. A survey at 3 to 4 months after training revealed continued use of physical maneuvers (3.8 +/- 3.1 per day), increased standing time with each episode of presyncopal symptoms (8.3 +/- 5.8 minutes), and continued global symptomatic improvement. Total peripheral resistance, but not heart rate or stroke index, showed significant regression with blood pressure improvement. CONCLUSION: Physical countermaneuvers are efficacious in reducing orthostatic hypotension, can be augmented by use of biofeedback, and may significantly improve the functional outcome. The major mechanism of improvement is an increase in total peripheral resistance, presumably by reducing the vascular capacitance.

NASA Program Space Physiology and Countermeasures↗

iGCE and MitoFlyght Spaceflight Missions: Unraveling Oxidative Stress Responses in Space

Thriving In DEep Space (TIDES) initiative aims to comprehensively understand how hostile environments such as the Moon and Mars affect human physiology. Here we present two NASA-selected spaceflight experiments under the TIDES portfolio, iGCE (Integrated Gravity Continuum Experiment) and MitoFlyght (Mitochondrial Investigation of Oxidative Stress in Flies). We hypothesize that exposure to spaceflight conditions induces oxidative stress responses that negatively impact physiology. The iGCE mission employs two well-established spaceflight models, Drosophila melanogaster and C.elegans, using Redwire’s Multi-use Variable-g Platform (MVP) hardware to assess changes in cardiac, muscle, and nervous systems across five different gravities: Hypergravity (2g), Earth (1g), Mars (0.37g), Moon (0.16g), and microgravity (ug). This mission focuses on uncovering alterations in protein homeostasis, autophagy, and mitochondrial function conserved across species. In the MitoFlyght mission to the ISS, Drosophila will be housed in the Vented Fly Box (VFB). This mission evaluates the oxidative stress response and autophagic pathway in muscle, heart, and nervous system. Additionally, we will (a) use the genetic mutant, Tor7/P to test whether increased autophagy is beneficial or a maladaptive response to the spaceflight stressors, and (b) utilize fly lines with tissue-specific expression (neuronal, muscle, and cardiac) of an antioxidant gene, SOD2 (superoxide dismutase) as a potential countermeasure. Data from these missions will be compared with previous LEO-based datasets to identify shared signatures. Furthermore, cross-species analysis of the transcriptomic data from other invertebrate and vertebrate spaceflight studies will help determine evolutionarily conserved pathways perturbed by space stressors. Overall, both these missions aim to provide crucial insights into the mechanisms underlying oxidative stress responses, synaptic changes, and heart and muscle deficits, facilitating the identification of diagnostic and therapeutic targets to mitigate the adverse health effects of long-duration space habitation. Ultimately, this research will enhance our ability to thrive in deep space and inform future missions.

Janani Iyer↗

Evaluation of the Combined Effects of Gamma Radiation and High Dietary Iron on Peripheral Leukocyte Distribution and Function

NASA is concerned with the health risks to astronauts, particularly those risks related to radiation exposure. Both radiation and increased iron stores can independently increase oxidative damage, resulting in protein, lipid and DNA oxidation. Oxidative stress increases the risk of many health problems including cancer, cataracts, and heart disease. This study, a subset of a larger interdisciplinary investigation of the combined effect of iron overload on sensitivity to radiation injury, monitored immune parameters in the peripheral blood of rats subjected to gamma radiation, high dietary iron or both. Specific immune measures consisted of (A) peripheral leukocyte distribution; (B) plasma cytokine levels; (C) cytokine production profiles following whole blood stimulation of either T cells or monocytes.

Crucian, Brian E.↗

Ventricular filling slows epicardial conduction and increases action potential duration in an optical mapping study of the isolated rabbit heart

INTRODUCTION: Mechanical stimulation can induce electrophysiologic changes in cardiac myocytes, but how mechanoelectric feedback in the intact heart affects action potential propagation remains unclear. METHODS AND RESULTS: Changes in action potential propagation and repolarization with increased left ventricular end-diastolic pressure from 0 to 30 mmHg were investigated using optical mapping in isolated perfused rabbit hearts. With respect to 0 mmHg, epicardial strain at 30 mmHg in the anterior left ventricle averaged 0.040 +/- 0.004 in the muscle fiber direction and 0.032 +/- 0.006 in the cross-fiber direction. An increase in ventricular loading increased average epicardial activation time by 25%+/- 3% (P < 0.0001) and correspondingly decreased average apparent surface conduction velocity by 16%+/- 7% (P = 0.007). Ventricular loading did not significantly alter action potential duration at 20% repolarization (APD20) but did at 80% repolarization (APD80), from 179 +/- 7 msec to 207 +/- 5 msec (P < 0.0001). The dispersion of APD20 was decreased with loading from 19 +/- 2 msec to 13 +/- 2 msec (P = 0.024), whereas the dispersion of APD80 was not significantly changed. These electrophysiologic changes with ventricular loading were not affected by the nonspecific stretch-activated channel blocker streptomycin (200 microM) and were not attributable to changes in myocardial perfusion or the presence of an electromechanical decoupling agent (butanedione monoxime) during optical mapping. CONCLUSION: Acute loading of the left ventricle of the isolated rabbit heart decreased apparent epicardial conduction velocity and increased action potential duration by a load-dependent mechanism that may not involve stretch-activated channels.

NASA Program Biomedical Research and Countermeasur↗

Lethality is Local, but Survival is Systemic: Temporal and Multi-Organ Responses to Chlorine Gas Exposure in a Murine Model

Chlorine gas (Cl2) is a highly toxic chemical associated with both localized lung injury and systemic health effects. While pulmonary damage has been well characterized, the systemic inflammatory and metabolic responses remain poorly understood. We aimed to define the temporal and multi-organ responses to Cl2 exposure in a murine model, with a focus on identifying spatiotemporal inflammation and its impact on survival and lethality. SKH1 mice were exposed for 10 min to varying concentrations of Cl2 (94.4–810 ppm, representative of non-lethal, LD10, and LD50 doses) and monitored for respiratory function, perfusion, and acidosis using organ-specific imaging. At multiple time points (40 min, 6 h, 24 h, and 7 d), we measured phosphoproteins, cytokines, chemokines, growth factors, and metabolic hormones in the lungs, heart, cortex, and plasma. Statistical modeling and logistic regression were used to identify biomarkers associated with lethality and survival. We found that lung injury was the primary cause of potential lethality, particularly via early phosphoprotein signaling disruptions. However, survival correlated with early systemic coordination of inflammatory and metabolic signals across organs. Perfusion and acidosis imaging were strongly associated with chemokine and hormone responses. Key survival-associated plasma biomarkers included decreased insulin, increased ghrelin, and decreased eotaxin. While potential lethality from Cl2 exposure is locally driven by pulmonary injury, survival depends on systemic, multi-organ responses that occur rapidly post-exposure. Within this model, our findings identify a potential therapeutic window to enhance survival and suggest candidate biomarkers that may be explored translationally for both triage and treatment of chlorine-related incidents.

chlorine gas↗

Cardiac beta-adrenergic receptors and coronary hemodynamics in the conscious dog during hypoxic hypoxia.

The mechanisms by which acute hypoxia (10% and 5% oxygen) mediates changes in coronary blood flow and cardiac function were investigated in the conscious dog. When the dogs breathed hypoxic gas mixtures through a tracheostomy, both arterial and coronary sinus oxygen tensions were significantly decreased. With 5% oxygen, there were significant increases in heart rate (25%), maximum left ventricular dP/dt (39%), left circumflex coronary artery blood flow (163%), and left ventricular oxygen consumption (52%), which were attenuated by beta-adrenergic blockage with propranolol. When electrical pacing was used to keep the ventricular rate constant during hypoxia, there was no significant difference in coronary blood flow before and after beta blockade. Beta-adrenergic receptor activity in the myocardium participates in the integrated response to hypoxia although it may not cause active vasodilation of the coronary vessels.

Erickson, H. H.↗

Vectorcardiograph

A system for quantitating the cardiac electrical activity of Skylab crewmen was required for three medical experiments (M092, Lower Body Negative Pressure; M171, Metabolic Activity; and M093, In-flight Vectorcardiogram) designed to evaluate the effects of space flight on the human cardiovascular system. A Frank lead vectorcardiograph system was chosen for this task because of its general acceptability in the scientific community and its data quantification capabilities. To be used effectively in space flight, however, the system had to meet certain other requirements. The system was required to meet the specifications recommended by the American Heart Association. The vectorcardiograph had to withstand the extreme conditions of the space environment. The system had to provide features that permitted ease of use in the orbital environment. The vectorcardiograph system performed its intended function throughout all the Skylab missions without a failure. A description of this system follows.

Lintott, J.↗

Voice Controlled Wheelchair

Michael Condon, a quadraplegic from Pasadena, California, demonstrates the NASA-developed voice-controlled wheelchair and its manipulator, which can pick up packages, open doors, turn a TV knob, and perform a variety of other functions. A possible boon to paralyzed and other severely handicapped persons, the chair-manipulator system responds to 35 one-word voice commands, such as "go," "stop," "up," "down," "right," "left," "forward," "backward." The heart of the system is a voice-command analyzer which utilizes a minicomputer. Commands are taught I to the computer by the patient's repeating them a number of times; thereafter the analyzer recognizes commands only in the patient's particular speech pattern. The computer translates commands into electrical signals which activate appropriate motors and cause the desired motion of chair or manipulator. Based on teleoperator and robot technology for space-related programs, the voice-controlled system was developed by Jet Propulsion Laboratory under the joint sponsorship of NASA and the Veterans Administration. The wheelchair-manipulator has been tested at Rancho Los Amigos Hospital, Downey, California, and is being evaluated at the VA Prosthetics Center in New York City.

Source record↗

Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: animal and human validation

OBJECTIVES: To determine the effect of preload in color M-mode Doppler flow propagation velocity (v(p)). BACKGROUND: The interpretation of Doppler filling patterns is limited by confounding effects of left ventricular (LV) relaxation and preload. Color M-mode v(p) has been proposed as a new index of LV relaxation. METHODS: We studied four dogs before and during inferior caval (IVC) occlusion at five different inotropic stages and 14 patients before and during partial cardiopulmonary bypass. Left ventricular (LV) end-diastolic volumes (LV-EDV), the time constant of isovolumic relaxation (tau), left atrial (LA) pre-A and LV end-diastolic pressures (LV-EDP) were measured. Peak velocity during early filling (E) and v(p) were extracted by digital analysis of color M-mode Doppler images. RESULTS: In both animals and humans, LV-EDV and LV-EDP decreased significantly from baseline to IVC occlusion (both p < 0.001). Peak early filling (E) velocity decreased in animals from 56 +/- 21 to 42 +/- 17 cm/s (p < 0.001) without change in v(p) (from 35 +/- 15 to 35 +/- 16, p = 0.99). Results were similar in humans (from 69 +/- 15 to 53 +/- 22 cm/s, p < 0.001, and 37 +/- 12 to 34 +/- 16, p = 0.30). In both species, there was a strong correlation between LV relaxation (tau) and v(p) (r = 0.78, p < 0.001, r = 0.86, p < 0.001). CONCLUSIONS: Our results indicate that color M-mode Doppler v(p) is not affected by preload alterations and confirms that LV relaxation is its main physiologic determinant in both animals during varying lusitropic conditions and in humans with heart disease.

Non-NASA Center↗