Search NASA⌕ Search

SEARCH · Search NASA

Results for “HOLLOW CATHODES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ion kinetics and nonlinear saturation of current-driven instabilities relevant to hollow cathode plasmas

Ion kinetics and time evolution of bulk plasma properties in the nonlinear saturation regime of a collisionless current-driven instability are studied using a 1D Vlasov–Poisson simulation. In the simulations, the ratio of initial electron bulk velocity to initial electron thermal velocity, called the electron Mach number, ranges from 0.5 to 2.5, and electron-to-ion temperature ratio is 10. A significant population of backstreaming high-energy ions is observed when the initial electron Mach number is larger than or equal to 1.3, which agrees with previous literature indicating transition to the Buneman instability. The simulations suggest that the electrons trapped in large-amplitude waves result in a bi-directional ion acoustic wave, which generates a backward-propagating high-energy ion distribution. Here, a concise formula that describes the high-energy ion distribution and potential fluctuation amplitude are obtained as a function of initial electron Mach numbers. Sputtering rate calculations using the non-Maxwellian distributions for ions obtained from the simulation and Maxwellian ion distributions of temperatures ranging from 0.5 to 4.0 eV are compared, illustrating the potential contribution of kinetic effects on cathode erosion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of the hollow cathode discharge on throttled ion thruster performance.

An experimental study performed on a 20 cm electron bombardment thruster shows substantial improvements in throttled performance can be achieved if cathode discharge region diameter and length, cathode flow rate and baffle aperture area are reduced simultaneously. This improvement is related to a thruster operating mode in which arc current does not vary significantly with arc voltage. In this mode it is possible to operate the thruster at a high arc voltage and a correspondingly high primary electron energy without the penalty of a prohibitively high arc power. Langmuir probe data indicate the arc current is limited by the cathode region plasma potential and electron density which are both nearly invariant with arc voltage.

Wilbur, P. J.↗

Hollow cathodes with BaO impregnated, porous tungsten inserts and tips

The technology of impregnated materials is described and some inherently advantageous characteristics of impregnated cathodes are discussed. Thermionic emission measurements are presented for oxide coated and impregnated cathodes. Five cathode configurations with barium oxide impregnated porous tungsten inserts and/or tips have been fabricated and tested. Reliability, durability, and stability of operation are characterized. One of the cathodes has accumulated over 9000 operational hours, another has been cycled on and off more than 800 times.

Hudson, W. R.↗

SERT 2 hollow cathode multiple restarts in space

Future missions, both station keeping and primary electric propulsion, will require multiple thrust restarts after periods of inactivity from a few hours to over one year. Although not a part of the original SERT 2 (Space Electric Rocket Test) flight objective, the opportunity to demonstrate multiple cathode restarts in space became available following completion of thruster running. Both neutralizer and main cathodes of each flight thruster were restarted repeatedly following storage periods up to 490 days. No deterioration of cathode heaters was noted nor was any change required in starting voltages or currents.

Kerslake, W. R.↗

A hollow cathode neutralizer for a 30-cm diameter bombardment thruster

Recent improvements in overall thruster performance have imposed new constraints on neutralizer performance. The use of compensated grid extraction system requires a reevaluation of neutralizer position. A series of tests were conducted to determine what effect neutralizer cathode geometry has on performance. The parameters investigated included orifice diameter and length, and cathode diameter. Similar tests investigated open and enclosed keeper geometries. Neutralizer position tests with compensated grids suggested positions approximately 10 cm from the accelerator and radially out of the beam envelope should result in satisfactory performance and long life. Operation at keeper current of 1.5 am resulted in lower total neutralizer power, the elimination of tip heater power, and suitable closed loop control of the neutralizer vaporizer.

Bechtel, R. T.↗

Hollow cathode restartable 15 cm diameter ion thruster

The effects of substituting high perveance dished grids for low perveance flat ones on performance variables and plasma properties within a 15 cm modified SERT II thruster are discussed. Results suggest good performance may be achieved as an ion thruster is throttled if the screen grid transparency is decreased with propellant flow rate. Thruster startup tests, which employ a pulsed high voltage tickler electrode between the keeper and the cathode to initiate the discharge, are described. High startup reliability at cathode tip temperatures of about 500 C without excessive component wear over 2000 startup cycles is demonstrated. Testing of a single cusp magnetic field concept of discharge plasma containment is discussed. A theory which explains the observed behavior of the device is presented and proposed thruster modifications and future testing plans are discussed.

Wilbur, P. J.↗

A hollow cathode neutralizer for a 30-cm diameter bombardment thruster

Recent improvements in overall thrustor performance have imposed new constraints on neutralizer performance. The use of compensated grid extraction system requires a re-evaluation of neutralizer position. In addition a suitable control logic for the neutralizer has proven difficult. A series of tests were conducted to determine what effect neutralizer cathode geometry has on performance. The parameters investigated included orifice diameter and length, and cathode diameter. Similar tests investigated open and enclosed keeper geometries. Neutralizer position tests with compensated grids suggest positions approximately 10 cm from the accelerator and radially out of the beam envelope should result in satisfactory performance and long life. Finally operation at keeper currents of 1.5 amp has resulted in lower total neutralizer power, the elimination of tip heater power, and suitable closed loop control of the neutralizer vaporizer.

Bechtel, R. T.↗

SERT II hollow cathode multiple restarts in space

Future missions, both station keeping and primary electric propulsion, will require multiple thruster restarts after periods of inactivity from a few hours to over one year. Although not a part of the original SERT II (Space Electric Rocket Test) flight objective, the opportunity to demonstrate multiple cathode restarts in space became available following completion of thruster running. Both neutralizer and main cathodes of each flight thruster have been restarted repeatedly following storage periods up to 490 days. No deterioration of cathode heaters has been noted nor has any change been required in starting voltages or currents.

Kerslake, W. R.↗

Hollow cathodes with BaO impregnated, porous tungsten inserts and tips

The technology of impregnated materials is described and some inherently advantageous characteristics of impregnated cathodes are discussed. Thermionic emission measurements are presented for oxide coated and impregnated cathodes. Five cathode configurations with barium oxide impregnated porous tungsten inserts and/or tips have been fabricated and tested. Reliability, durability, and stability of operation are characterized. One of the cathodes has accumulated over 9000 operational hours, another has been cycled on and off more than 900 times.

Hudson, W. R.↗

Pulse ignition characterization of mercury ion thruster hollow cathode using an improved pulse ignitor

An investigation of the high voltage pulse ignition characteristics of the 8 cm mercury ion thruster neutralizer cathode identified a low rate of voltage rise and long pulse duration as desirable factors for reliable cathode starting. Cathode starting breakdown voltages were measured over a range of mercury flow rates and tip heater powers for pulses with five different rates of voltage rise. Breakdown voltage requirements for the fastest rising pulse (2.5 to 3.0 kV/micro sec) were substantially higher (2 kV or more) than for the slowest rising pulse (0.3 to 0.5 kV/micro sec) for the same starting conditions. Also described is an improved, low impedance pulse ignitor circuit which reduces power losses and eliminates problems with control and packaging associated with earlier designs.

Wintucky, E. G.↗

Pulse ignition characterization of mercury ion thruster hollow cathode using an improved pulse ignitor

An investigation of the high voltage pulse ignition characteristics of the 8-cm mercury ion thruster neutralizer cathode identified a low rate of voltage rise and long pulse duration as desirable factors for reliable cathode starting. Cathode starting breakdown voltages were measured over a range of mercury flow rates and tip heater powers for pulses with five different rates of voltage rise. Breakdown voltage requirements for the fastest rising pulse (2.5 to 3.0 kV/microsec) were substantially higher (2 kV or more) than for the slowest rising pulse (0.3 to 0.5 kV/microsec) for the same starting conditions. The paper also describes an improved, low impedance pulse ignitor circuit which reduces power losses and eliminates problems with control and packaging associated with earlier designs.

Wintucky, E. G.↗