Search NASA⌕ Search

SEARCH · Search NASA

Results for “Heat Generation Rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Fabrication and Characterization of Non-Equilibrium Plasma-Treated PVDF Nanofiber Membrane-Based Sensors

The effect of a self-pulsing non-equilibrium plasma discharge on piezoelectric PVDF nanofiber membrane was investigated. The plasma discharge was generated in air with a DC power source, with a discharge current of 0.012 mA, a nominal interelectrode separation of 1 mm, and discharge voltage of ~970 V. In a continuous fabrication process, the electrospinning method was used to generate thin nanofiber membrane with a flow rate of 0.7–1 mL h -1 and 25–27 kV voltage to obtain the nanofiber with high sensitivity and a higher degree of alignment and uniformity over a larger area. Plasma treatment was applied on both single layer and multi-layer (three layers) nanomembranes. In addition, simultaneously, the nanofiber membranes were heat-treated at a glass transition temperature (80–120 °C) and then underwent plasma treatment. Fourier-transform infrared (FTIR) spectroscopy showed that the area under the curve at 840 and 1272 cm -1 (β phase) increased due to the application of plasma and differential scanning calorimeter (DSC) indicated an increase in the degree of crystallinity. Finally, PVDF sensors were fabricated from the nanofibers and their piezoelectric properties were characterized. The results suggested that compared to the pristine samples the piezoelectric properties in the plasma and plasma-heat-treated sensors were enhanced by 70% and 85% respectively.

42 ENGINEERING↗

Characterization of build parameters and microstructure in low heat input WAAM of Ni-based superalloy Haynes 282

Conference paper for 2024 10th International Conference on Advances in Materials, Manufacturing & Repair for Power Plants. Ni-based superalloy Haynes 282 is a prime candidate for advanced power generation systems due to its superior fabricability, weldability, and high-temperature performance. Additive manufacturing offers potential cost and time savings for gas turbine components. Wire-arc direct energy deposition can create large components but often requires post-processing treatments, such as hot isostatic pressing (HIP), to address porosity. This study explores a low heat-input, high deposition rate GMAW process to achieve fully dense Haynes 282 without HIP. Twenty-one blocks were deposited, varying travel and wire feed speeds. Initial analysis (visual inspection, microstructural examination, and CT) revealed the impact of build parameters on internal porosity and defects. Scanning electron microscopy provided insights into structural heterogeneity and microstructural properties. Related journal article can be found at https://doi.org/10.31399/asm.cp.am-epri-2024p0001.

Adam, Benjamin↗

Synchronous Machine Governor Upgrade

Conventional generation sources play a critical role in the stability and reliability of the electrical grid, particularly as we transition towards more renewable energy sources. To understand and accurately emulate their behavior for optimizing grid operations and ensuring seamless integration with renewable technologies, it is essential to better emulate the grid- and plant-level impacts of conventional generation sources, such as natural gas (NG) driven heat recovery steam generators (HRSGs) and combustion turbines (CTs). Therefore, a governor model is developed in a programmable logic controller (PLC) to investigate the performance of the conventional generator under various dynamic operating conditions and to identify the impact on grid stability in a controlled environment. The governor model aims to enable the hardware-in-the-loop (HIL) based emulation of these conventional generation sources using the existing 2 MVA synchronous machine/generator that is driven by a flexible 2.5 MW variable speed drive. This setup will allow us to replicate the dynamic characteristics and response behaviors of NG-driven HRSGs and CTs. The controls for the emulated conventional plants follow the industry standard and are adjustable, ensuring they accurately reflect the operational capabilities and limitations of real-world systems. These controls include load-following capabilities, ramp rates, startup and shutdown sequences, and emissions characteristics. By incorporating these adjustable controls, we aim to capture the nuanced impacts of conventional generation, such as their ability to provide ancillary services like frequency regulation, voltage support, and spinning reserve. In this report, we simulate two types of dynamic operations: grid-connected and islanding. For each dynamic operation, representative starting sequences are tested, including turbine purge, ignition, speed ramping up, generator excitation and synchronizing, and breaker close. The HIL based tests provides insights for field deployment, specifically the high-fidelity governor model provides results to predict the potential stability and reliability risk and suggest possible integration measures (e.g., generation and load balancing, tuning of governor control parameters). Ultimately, this enhanced emulation capability will be integrated into our Advanced Research on Integrated Energy Systems (ARIES), enabling us to conduct comprehensive studies on the interactions between conventional and renewable energy sources. By better understanding these interactions, we can develop strategies to optimize the overall performance and reliability of the grid. This will support the deployment of advanced grid management techniques, such as demand response, grid-forming inverters, and energy storage systems. The main contributions are summarized as follows: (1) This report introduces a PLC-based governor model for gas turbines. This model accurately simulates the dynamic behavior of conventional generation sources under various operational scenarios; (2) The model is integrated with an HIL testbed that includes a 2.5 MW variable speed drive and a 2 MVA synchronous machine. This setup enables realistic, real-time emulation of conventional power plants, particularly NG driven HRSGs and CTs; (3) The developed model is adaptable to various gas turbine configurations and allows for precise control over parameters such as MW ramp rates. This flexibility makes it a valuable tool for future research and industry collaboration; and (4) By incorporating the model into the National Renewable Energy Laboratory's Advanced Research on Integrated Energy Systems, the report lays the groundwork for future studies on interactions between conventional and renewable energy sources, enhancing the ability to develop advanced grid management strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of the Mechanisms Underpinning Plasma-Catalyst Interaction for the Conversion of Methane to Oxygenates

Plasma catalysis is a promising approach to further enhance the conversion of methane into value-added products such as methanol. In this work, the mechanisms enabling the conversion of methane to CO, CO 2 and methanol enabled by plasma-enhanced catalysis were investigated. A catalyst reactor was incorporated downstream of the plasma jet to enable the separation between plasma generation and the catalyst bed. An enhancement in CH 3 OH and CO 2 production was observed for the shortest distance between the plasma and catalyst compared to the plasma-only case. Plasma-enabled gas heating was shown not to be responsible for the observed synergy while a gas temperature increase as low as 30-40 K significantly impacted desorption rates of CH 3 OH/C 2 H 5 OH on alumina particles. Correlations between molecular beam mass spectrometry (MBMS) measurements at the inlet and outlet of the catalytic reactor suggest that the observed synergistic effect was caused by radical species most likely the CH 3 O 2 radical. As a result, this study shows that surface reactions induced by radicals such as alkylperoxy radicals might play an important role in surface reactions in plasma-catalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature-dependent microbial reactions by indigenous microbes in bentonite under Fe(III)- and sulfate-reducing conditions

Bentonite is a promising buffer material for constructing spent nuclear fuel (SNF) repositories. However, indigenous microbes in bentonite can be introduced to the repository and subsequent sealing of the repository develops anoxic conditions over time which may stimulate fermentation and anaerobic respiration, possibly affecting bentonite structure and SNF repository stability. Moreover, the microbial activity in the bentonite can be impacted by the heat generated from radionuclides decay. Therefore, to investigate the temperature effect on microbial activities in bentonite, we created microcosms with WRK bentonil (a commercial bentonite) using lactate as the electron donor, and sulfate and/or ferrihydrite (Fe(III)) as electron acceptors with incubation at 18 °C and 50 °C. Indigenous WRK microbes reduced sulfate and Fe(III) at both temperatures but with different rates and extents. Lactate was metabolized to acetate at both temperatures, but only to propionate at 18 °C during early-stage microbial fermentation. More Fe(III)-reduction at 18 °C but more sulfate-reduction at 50 °C was observed. Thermophilic and/or metabolically flexible microbes were involved in both fermentation and Fe(III)/ sulfate reduction. In conclusion, our findings illustrate the necessity of considering the influence of temperature on microbial activities when employing bentonite as an engineered buffer material in construction of SNF repository barriers.

59 BASIC BIOLOGICAL SCIENCES↗

Evaluation of Spray and Combustion Models for Simulating Dilute Combustion in a Direct-Injection Spark-Ignition Engine

Dilute combustion in spark-ignition engines has the potential to improve thermal efficiency by mitigating knock and by reducing throttling and wall heat losses. However, ignition and combustion processes can become unstable for dilute operation due to a lowered laminar flame speed, resulting in excessive cycle-to-cycle variability (CCV) of the combustion process. To compensate for the slower combustion in less reactive mixtures, a modified intake port geometry can be employed to generate a strong tumble flow in the cylinder and elevate turbulence levels around the spark plug, thereby promoting a faster transition to turbulent deflagration. Consequently, optimizing combustion chamber geometry and operating strategy is crucial to maximizing the benefits of using dilute combustion with enhanced in-cylinder turbulence across a wide range of operating conditions. Computational fluid dynamics (CFD) simulations can be utilized for virtual engine optimization tasks, but this would require the models to be truly predictive regarding the impact of changes to the engine design and operational parameters.In this study, multicycle large-eddy simulations (LES) are performed for a direct-injection spark-ignition engine to investigate the model performance in predicting engine combustion characteristics with respect to changes in the intake configuration. A tumble plate that blocks the lower part of the intake port inlet is used to vary the tumble. A set of CFD models that have been recently developed are employed, which takes into account the drag of nonspherical droplets, flash-boiling behavior of liquid sprays, spray-wall interaction, surrogate formulation of a research-grade E10 gasoline, and fast chemical kinetic solvers. Simulation results are compared to experimental engine data in terms of cylinder pressure, apparent heat release rate, mass fraction burned timing, and flame images. It is found that LES employing the state-of-the-art CFD models are capable of properly predicting the spray processes and reproducing the measured mean cylinder pressure for the case with the tumble plate. On the other hand, the LES over-predicts the combustion rate during the early combustion stage and under-estimates the CCV, and these discrepancies become larger when the tumble plate is removed.

computational fluid dynamics simulation↗

Evaluation and selection of eutectic salts combined with metal foams for applications in high-temperature latent heat thermal energy storage

This study presents a systematic process for selecting eutectic salts for use in latent heat thermal energy storage (LHTES), and provides experimental evidence regarding their performance. One primary goal was to identify the most suitable eutectic salt for use with metallic foams over a temperature range of 450 °C–500 °C. Twenty-one eutectic salts were preselected for comparison. Here, the performance and cost-effectiveness of each were evaluated based on the Ragone relation, enabling a fair comparison of each salt's heat storage capacity and power density relative to cost. As a result, MgCl-NaCl, CaCl 2 -NaCl, and FLiNaK were selected as the most promising candidates. Subsequently, experiments were performed to demonstrate the compatibility of the selected salts with metal foams while the copper and aluminum foams were immersed in the salts at 550 °C for 120 h. Combining C10100 (copper alloy) foam with CaCl 2 -NaCl was observed to generate the least surface corrosion due to oxidation. The charge/discharge performance and thermal stability of CaCl 2 -NaCl, both with and without the copper foam, were also tested to confirm the feasibility of this combination. The capsule with the copper foam showed enhanced performance (a 13 % reduced discharge rate) in comparison to the capsule without copper foam. The melting point of the CaCl 2 -NaCl remained unchanged for 300-h duration of the cyclic melting/solidification experiments, and no thermal stability issues were observed.

25 ENERGY STORAGE↗

Method to control the etching rate of materials

A method for etching materials in which organic solvents are added to the etching mixture and combined in a mixing arrangement. When agitated organic materials mix with the etching agent and interact with the underlying material to form a shield around the etched areas that prevents the additional interaction of water with the newly etched areas and enables the etching of silicon oxides (SiOx) but does not oxidize Si. This method leads to milder reactions with less heat generation and avoids the safety hazards associated with conventional etching methods.

Yi, Ran↗

BISON validation to in situ cladding burst test and high-burnup LOCA experiments

The process for developing and qualifying nuclear fuels for commercial nuclear application requires fundamental material development, characterization, and design; out-of-pile testing on unirradiated materials; integral fuel rod irradiations, testing, and postirradiation examinations; and transient analyses. The historical approach depends on the generation of large empirical datasets and series of integral fuel rod irradiations, and this approach ultimately takes ~20 years—or sometimes longer—to acquire data through extensive sequential testing. Thus, the qualification and eventual deployment of new fuel systems constitute a long process. However, recent technological advancements have provided researchers the opportunity to perform out-of-cell, in situ measurements to assess material performance for the duration of the experiment. One such example of this capability is the use of digital image coordination and thermal imaging to assess Zircaloy cladding performance under a simulated loss-of-coolant accident (LOCA) transient condition. In situ measurements generally provide high-fidelity strain, strain rates, and temperature surface maps. This is critical for the US nuclear industry, which is actively developing a technical basis to support extending the peak rod average burnup from 62 to ~75 GWd/tU and the deployment of accident-tolerant fuel. However, the US Nuclear Regulatory Commission (NRC) outlined in its research information letter several technical issues that the industry must address before extending burnup. One topic of specific interest is understanding the cladding balloon and rupture geometry during the LOCA heat-up phase. By leveraging these advanced in situ capabilities, this work used in situ data generated from a simulated LOCA to better understand high-temperature creep and its effect on Zircaloy balloon and rupture performance. Here, this work used the BISON fuel performance code to assess the high-temperature creep model predictions with in situ data.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Flash Recycling of Graphite Anodes

The ever-increasing production of commercial lithium-ion batteries (LIBs) will result in a staggering accumulation of waste when they reach their end of life. A closed-loop solution, with effective recycling of spent LIBs, will lessen both the environmental impacts and economic cost of their use. Presently, <5% of spent LIBs are recycled and the regeneration of graphite anodes has, unfortunately, been mostly overlooked despite the considerable cost of battery-grade graphite. Here, in this work, an ultrafast flash recycling method to regenerate the graphite anode is developed and valuable battery metal resources are recovered. Selective Joule heating is applied for only seconds to efficiently decompose the resistive impurities. The generated inorganic salts, including lithium, cobalt, nickel, and manganese, can be easily recollected from the flashed anode waste using diluted acid, specifically 0.1 M HCl. The flash-recycled anode preserves the graphite structure and is coated with a solid-electrolyte-interphase-derived carbon shell, contributing to high initial specific capacity, superior rate performance, and cycling stability, when compared to anode materials recycled using a high-temperature-calcination method. Life-cycle-analysis relative to current graphite production and recycling methods indicate that flash recycling can significantly reduce the total energy consumption and greenhouse gas emission while turning anode recycling into an economically advantageous process.

36 MATERIALS SCIENCE↗

An Efficient Annual-Performance Model of a Geothermal Network for Improved System Design, Operation, and Control: Preprint

Geothermal district energy systems (DES), and specifically geothermal networks, provide a viable solution for decarbonizing residential and commercial heating and cooling loads. District energy systems of all kinds enable a thermal resource with a relatively high capital cost (such as a geothermal borehole field) to be shared among a large number of users. While district heating and cooling has been studied for many years, geothermal networks, fifth generation DES that utilize water-source heat pumps and an ambient temperature loop to meet heating and cooling loads, have not been implemented extensively and thus require additional technical and economic optimization to obtain maximum benefits. This paper presents a newly developed reduced-order model that captures the flow of energy within the network, including the commercial and residential users' electrical usage, at an hourly rate over a year. The model includes building loads, heat pumps, borehole fields, and auxiliary heat/cool input, all connected with an ambient-temperature thermal loop model. In the model, operational control is possible for the borehole fields, circulation pump, and auxiliary system. For a given system, the model can output the complete state parameters for each component, the thermal loop, and the collective system, such as flow rate over time, average thermal loop temperature over time, and total electricity usage. The model can also be used to optimize the system control for maximizing system efficiency or minimizing system operational cost. For example, one initial assessment of the borehole controller for an example system showed that a controller with on/off operation of the borehole field reduces annual electrical usage by 33%, compared with continuous operation mode. Hence, the model can assist in optimizing a given system's operation to get the most value out of a geothermal network installation. Future work will consider the model's application to a demonstration project, including the model validation against operational data and system operation optimization.

ambient-temperature loop↗

Oblique instability of quasi-parallel whistler waves in the presence of cold and warm electron populations

Whistler waves propagating nearly parallel to the ambient magnetic field experience a nonlinear instability due to transverse currents when the background plasma has a population of sufficiently low energy electrons. Intriguingly, this nonlinear process may generate oblique electrostatic waves, including whistlers near the resonance cone with properties resembling oblique chorus waves in the Earth’s magnetosphere. Focusing on the generation of oblique whistlers, earlier analysis of the instability is extended here to the case where low-energy background plasma consists of both a “cold” population with energy of a few eV and a “warm” electron component with energy of the order of 100 eV. This is motivated by spacecraft observations in the Earth’s magnetosphere where oblique chorus waves were shown to interact resonantly with the warm electrons. The main new results are: 1) the instability producing oblique electrostatic waves is sensitive to the shape of the electron distribution at low energies. In the whistler range of frequencies, two distinct peaks in the growth rate are typically present for the model considered: a peak associated with the warm electron population at relatively low wavenumbers and a peak associated with the cold electron population at relatively high wavenumbers; 2) overall, the instability producing oblique whistler waves near the resonance cone persists (with a reduced growth rate) even in the cases where the temperature of the cold population is relatively high, including cases where cold population is absent and only the warm population is included; 3) particle-in-cell simulations show that the instability leads to heating of the background plasma and formation of characteristic plateau and beam features in the parallel electron distribution function in the range of energies resonant with the instability. The plateau/beam features have been previously detected in spacecraft observations of oblique chorus waves. However, they have been attributed to external sources and have been proposed to be the mechanism generating oblique chorus. In the present scenario, the causality link is reversed and the instability generating oblique whistler waves is shown to be a possible mechanism for formation of the plateau and beam features.

79 ASTRONOMY AND ASTROPHYSICS↗

County-level assessment of behind-the-meter solar and storage to mitigate long duration power interruptions for residential customers

Customer concerns over electric system resilience could drive early adoption of behind-the-meter solar-plus-storage (BTM PVESS), especially as wildfire, hurricane, and other climate-driven risks to electric grids become more pronounced. However, the resilience benefits of BTM PVESS are poorly understood, especially for residential customers, owing to lack of data and methodological challenges, making it difficult to forecast adoption trends. In this paper, we develop a methodology to model the performance of BTM PVESS in providing backup power across a wide range of customer types, geography / climate conditions, and long duration power interruption scenarios, considering both whole-building backup and backup of specific critical loads. We combine novel, disaggregated end-use load profiles across the continental United States with temporally and geospatially aligned solar generation estimates. We then implement a PVESS dispatch algorithm to calculate the amount of load served during interruptions. We find that PVESS with 10 kWh of storage can meet a limited set of critical loads in most United States counties during any month of the year, though this capability drops to meeting only 86% of critical load, averaged across all counties and months, when heating and cooling are considered critical. Backup performance is lowest in winter months where electric heat is common (southeast and northwest U.S.) and in summer months in places with large cooling loads (southwest and southeast U.S.). Winter backup performance varies by roughly 20% depending on infiltration rates, while summer performance varies by close to 15% depending on the efficiency of the central air-conditioning system. Differences in temperature set-points in Harris County correspond to a 40% range in winter backup performance and a 20% range in summer performance. Economic calculations show that a customer’s resilience value of PVESS must be high to motivate adoption of these systems.

14 SOLAR ENERGY↗

Investigation of the Effect of Atmospheric Plasma Treatment in Nanofiber and Nanocomposite Membranes for Piezoelectric Applications

In this work, we report the effect of steady-state atmospheric plasma (Corona discharge) in nanofibers and nanocomposite membranes for piezoelectric applications. The investigation was performed in PVDF (Poly vinylidene fluoride) nanofibers, CNT (Carbon Nanotubes)-reinforced PVDF nanocomposites, and PAN (Poly acrylonitrile) nanofiber membranes. Steady-state plasma was generated with a high voltage power source with 1 mA discharge current output and 6 kV discharge voltage, and the gap between tip and the material was maintained to be 1 cm. For the fabrication of nanofibers and nanocomposite membranes, an electrospinning method was used. The electrospinning parameters, such as flow rate and voltage, were optimally tuned for obtaining uniform nanofibers and nanomembranes. Along with the plasma treatment, heat treatment above the glass transition temperature was also conducted on the nanofiber membranes. Using a Scanning Electron Microscope (SEM), the morphology of the nanofibers was observed. X-ray Diffraction (XRD) demonstrated the polycrystallinity of the nanofibers. Fourier Transform Infrared Spectroscopy (FTIR) analysis of the PVDF nanofibers shows a peak at 796 cm−1 representing α-phase (C-H rocking) in the control sample which is absent in the treated samples. Raman spectroscopy of PVDF nanofibers identifies a Raman shift from 873 cm−1 to 877 cm−1 (denoting β-phase) for plasma-treated samples only. Electron Paramagnetic Resonance (EPR) concludes that the intensity of the free radicals increases from 1.37 to 1.46 (a.u.) after plasma treatment. Then, sensors were fabricated from the PVDF nanofibers, MWCNT-reinforced PVDF nanofibers, and PAN nanofibers to characterize their piezoelectric properties. The impact test results showed that the atmospheric plasma and heat-treated samples had 86%, 277%, and 92% increases of the d33 value (piezoelectric coefficient) in the case of PVDF nanofibers, MWCNT-reinforced nanofibers, and PAN nanofibers, respectively. It was also observed that the capacitance of the nanofiber membranes has increased due to the plasma treatment.

Biochemistry & Molecular Biology↗

Self-powered Heating: Efficiency Analysis

Conventional fuel-fired heating devices such as furnaces, boilers, and water heaters have fuel efficiency less than 100% on the basis of higher heating value. They also require electricity from the electric grid to power parasitic loads such as blowers, pumps, fans, and ignitors. The primary energy efficiency of the device accounts for both fuel used on-site and primary energy used off-site to produce electric power used by the device. This work compares conventional fuel-fired heating devices to two types of self-powered devices. A self-powered device (SPD) integrates a power cycle onboard to eliminate consumption of grid electricity. We assume that all heat rejected by the onboard power cycle is added to the process fluid, so that, compared with a conventional device, the same amount of heat is provided to the process fluid and the same amount of fuel is consumed, but grid electricity consumption is eliminated. The first SPD type is the basic one: exactly the electricity required is generated. The second type considered is the SPD with heat pump (SPD-HP), in which the power cycle generates more electricity than needed for parasitic loads, and the excess electricity is used to power a heat pump. The heat pump extracts additional heat from the ambient to boost efficiency. Both SPD and SPD-HP self-consume all the generated electricity, in contrast to combined heat and power (CHP) systems that export electricity. In this work, equations are derived to express the efficiency of three classes of heating devices: conventional (consuming grid electricity), self-powered (consuming no grid electricity), and self-powered with heat pump. The efficiency of each is derived as a function of up to six factors: (1) the fraction of combustion heat captured, (2) the rate of parasitic power consumption, (3) the fraction of electric energy dissipated as useful heat, (4) the power cycle conversion efficiency, (5) the grid efficiency, when applicable, and (6) the heat pump COP, when applicable. Scenarios are identified in which it is possible to achieve efficiency greater than 100% on a higher heating value basis. Plausible configurations using existing technology options are outlined.

Gluesenkamp, Kyle↗

Electrospun Separator Based on Sulfonated Polyoxadiazole with Outstanding Thermal Stability and Electrochemical Properties for Lithium-Ion Batteries

Traditional polyolefin separators used in lithium-ion batteries (LIBs) are seriously limited by the issues of inferior security and poor electrolyte wettability. Most of the very promising candidate separators based on heat-resistant polymers are, however, inherently difficult to process. Herein, a unique sulfonated aromatic heterocyclic polymer, lithiated poly(diphenyl ether oxadiazole) sulfonate (Li-SPEOD), was synthesized through a simple one-pot method and further electrospun to act as a novel separator (es-Li-SPEOD) for LIBs. In this work, the prepared Li-SPEOD possesses a high degree of sulfonation with a high molecular weight (M w = 4.31 × 10 5 ). The es-Li-SPEOD separator exhibits excellent mechanical and fire-resistance properties and is able to maintain dimensional stability at a temperature of even up to 400 °C in air. The ionic conductivity (3.57 mS cm –1 ) and lithium-ion transference number (0.37) of the es-Li-SPEOD with an electrochemical stability window of 4.5 V vs Li + /Li can be improved by 382.4 and 32.1%, respectively, compared to those of Celgard-2500 in the LiPF 6 electrolyte. The enhanced rate capability and cycle performance of the LiFePO 4 –Li half-cell are therefore obtained. Moreover, the es-Li-SPEOD displays an outstanding dendrite-suppressing effect for the lithium metal anode. This research proves that the Li-SPEOD-based separator has a broad application perspective in next-generation lithium batteries.

25 ENERGY STORAGE↗

Technical, economic, and load-following capabilities assessment of grid-connected geothermal and geothermal-solar hybrid systems

The technical and economic performance as well as the load-following capabilities of grid-connected geothermal hybrid systems were assessed in this work. The analyzed geothermal hybrid configuration is composed of a binary geothermal plant integrated with a concentrating solar-thermal system and underground thermal energy storage (UTES) through a primary heat exchanger. Physics-based models for the hybrid system for plant generation capacities of 1, 25, and 50 MW were developed from validated models for each subsystem. Also, an economic model was developed that accounts for different hybrid system capabilities, solar field sizes, and thermal storage duration. The advantage of the geothermal hybrid system was assessed by comparing the performance with the baseline benchmark geothermal plant with a similar configuration and generation capacity. It was found that hybridizing geothermal plants with concentrating solar and thermal energy storage not only improves the thermal efficiency by up to 8 percentage points when additional heat from the solar-UTES loop rises the evaporator temperatures from 70 to 125 °C, but also enhances the load-following capability for the geothermal plant, which can meet a typical residential load profile with a power rate of change 0.25 kW/s with an absolute error under 13 kW for a 1 MW plant. Other benefits of hybridization include resource preservation and a potential LCOE reduction of up to 56% for a 50 MW geothermal hybrid plant having a 50% solar share, a 1.4 solar multiple, and 24-h storage capacity. The results presented in this work demonstrate that hybridizing geothermal systems transforms them into a flexible and cost-effective solution for addressing the dynamic requirements of modern electric grids.

15 GEOTHERMAL ENERGY↗

Effects of Gasoline Composition and Operating Parameters on the Response of End-Gas Autoignition to Nitric Oxide in a Lean-Burn DI-SI Engine

Lean operation of spark-ignition engines can lead to engine thermal efficiency gains and lower NOx emissions due to reduced combustion temperatures. Yet, lean operation could still face challenges in end-gas autoignition and knock generation due to higher intake pressures and trapped NO in the residual gas. Here, this study evaluates the impact of NO on end-gas autoignition for two gasoline fuels with similar octane rating but different composition: high cycloalkane fuel (HCA) and high olefin fuel (HO). Experiments were performed at stoichiometric and lean (λ = 2) conditions and at two engine speeds of 1400 rpm and 2000 rpm. Accompanying chemical kinetics simulations in CHEMKIN revealed that the mechanisms controlling the effect of NO on autoignition are similar λ = 2 and λ = 1, with NO + HO 2 = NO 2 + OH being the main pathway for enhancing reactivity by promoting low-temperature heat release (LTHR). The compositionally different fuels reacted differently to NO seeding and engine speed, and differences were augmented at λ = 2 compared to λ = 1 as the end-gas autoignition shifted to the low temperature regime. HO, which has inherent low temperature chemistry, was strongly impacted by engine speed at low NO seeding levels, with no noticeable peak of LTHR detected at 2000 rpm. On the other hand, LTHR of HCA was marginally affected by shortened residence time at higher engine speed as NO + HO 2 reaction was not greatly affected by shorter time scales, since HO 2 production was sustained even at 2000 rpm to support OH generation from NO + HO 2 . Contrary to HO, HCA exhibited greater sensitivity to NO seeding, as the increased OH production at higher NO concentrations offset the OH-quenching effect of cyclopentane, which accounts for 28.6% of HCA’s composition. Consequently, a sensitivity analysis revealed that fuels with weak inherent low-temperature chemistry, like HCA, are likely to be more sensitive to variations in NO concentration and charge temperature, whereas fuels with strong low temperature chemistry are more sensitive to variations in end-gas λ and intake pressure.

Energy↗