Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Power RF Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A Preliminary Feasibility Study on Multi-Cavity Cryomodule Integration for the Electron Ion Collider Energy Recover Linac Cooler

The Electron-Ion Collider (EIC) is a state-of-the-art accelerator designed for collisions between highly polarized electrons and ions. To achieve optimal luminosity, the ion beam is cooled using an electron beam sourced from an energy recovery linac (ERL). In the current ERL baseline design, one BNL type RF cavity is used per cryomodule, leading to spatial and cost challenges. This study examines the feasibility of using more compact PERLE (Powerful Energy Recovery Linac for Experiments) type cavities, which can house multiple cavities within a single cryomodule, by evaluating their Beam Breakup (BBU) instability performance. Higher Order Modes (HOM) parameters were obtained through frequency scaling, assuming constant quality factor Q_L, R/Q, and linearly scaling HOM frequencies. To predict the BBU threshold current and ensure accuracy, two different BBU tracking simulations are used for cross-verification. Although the reduced footprint of PERLE-type cavities is advantageous, maintaining sufficient damping of HOMs remains crucial. Finally, we compare the HOM damping efficiency of both cavity types and suggest a pathway forward.

Deitrick, K.↗

ERL-Based Compact X-Ray FEL

We propose to develop an energy-recovery-linac (ERL)-based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser

This is the final report for the DoE BES contract DE-FG02-07ER46272. This grant began under a title that gives its history in a few words: The Physics of Gain Mechanisms in a Self-Amplified Spontaneous Emission Free-Electron Laser. At the time of adopting this name, the UCLA Particle Beam Physics Laboratory (PBPL) was at the forefront of the first demonstrations of SASE FEL, giving the experimental basis for the 4th generation X-ray light source now exemplified by the LCLS, a remarkable generation of machines that have revolutionize nanoscale and ultrafast science. The grant title indicates that physical aspects of the FEL are of interest, and implies that progress requires comprehensive investigations. These aspects include: the physics and technology of high brightness electron beam generation, phase space manipulations, advanced beam diagnostics, state-of-the-art undulators, studies of FEL mode characteristics, as well as the introduction of new theoretical models and start-to-end simulations, all yielding a deep understanding of the SASE FEL. The latest period (2010-13) of BES grant support has been the most productive yet for the UCLA PBPL, and the extensive list of accomplishments is illustrative of our central contributions to advanced FEL research. We give a concise overview here and review our research results in further detail below. In FEL and ultrafast beam physics, we have experimentally investigated: production of helical beams and FEL modes with orbital angular momentum; chirp-taper single-spike FEL gain; new FROG techniques optimized for FEL, introduced coherent imaging of beam profiles using transition radiation; and demonstrated a next generation cryoundulator. We have performed deep theoretical studies of these phenomena and other advanced FEL physics concepts, such as the space-charge amplifier. In high brightness beams, we have: introduced a new class of hybrid photoinjector for <100 fs beam production; developed new approaches to self-shaped ellipsoidal beams; used nonlinear plasma oscillations to create beam pulse trains; tested new plasmonic, high quantum efficiency cathodes, and developed new methods of beam measurement with um spatial/sub-fs temporal resolution. In ultrafast imaging, we have: developed advanced electro-optic timing systems, performed the 1st pump-probe study using single shot UED, demonstrated continuously time-resolved UED with RF deflection; made initial use of inverse Compton scattering (ICS) X-ray sources in application through single-shot inline phase contrast imaging, established single-shot X-ray diffraction, and observed ICS high harmonic generation and redshifting due to nonlinear effects. In 5th generation light source research, we have developed the techniques of narrowband, very high power coherent Cerenkov radiation sources based on dielectric wakefield devices. This work is represented by numerous publications in leading journals: e.g. Nature Physics, Physical Review Letters, Applied Physics Letters. The PBPL program’s influence on the field also extends to organization of the electron beam applications community; we have organized the first international UED workshops and the initial two meetings dedicated to 5th generation light source.

43 PARTICLE ACCELERATORS↗

ERL-BASED COMPACT X-RAY FEL

We propose to develop an energy-recovery-linac (ERL)- based X-ray free-electron laser (XFEL). Taking advantage of the demonstrated high-efficiency energy recovery of the beam power in the ERL, the proposed concept offers the following benefits: i) recirculating the electron beam through high-gradient superconducting RF (SRF) cavities shortens the linac, ii) energy recovery in the SRF linac saves the klystron power and reduces the beam dump power, iii) the high average beam power produces a high average photon brightness. In addition, such a concept has the capability of delivering optimized high-brightness CW X-ray FEL performance at different energies with simultaneous multipole sources. In this paper, we will present the preliminary results on the study of feasibility, optics design and parameter optimization of such a device.

Lin, Fanglei↗

Photon Source Capabilities of the Jefferson Lab FEL

Jefferson Lab operates a superconducting energy recovered linac which is operated with CW RF and which powers oscillator-based IR and UV Free Electron Lasers (FELs) with diffraction limited sub-picosecond pulses with >10{sup 13} photons per pulse (1.0%BW) at pulse repetition frequencies up to 75 MHz. Useful harmonics extend into the vacuum ultraviolet (VUV). Based on FEL model calculations validated using this facility, we have designed both an oscillator-based VUV-FEL that would produce 6 10{sup12} coherent (0.5% BW) 100 eV photons per pulse at multi-MHz repetition rates in the fundamental, and a dual FEL configuration that would allow simultaneous lasing lasing at THz and UV wavelengths. The VUV-FEL would utilize a novel high gain, low Q cavity, while the THz source would be an FEL oscillator with a short wiggler providing diffraction limited pulses with pulse energy exceeding 50 microJoules. The THz source would use the exhaust beam from a UVFEL. Such multiphoton capabilities would provide unique opportunities for out of equilibrium dynamical studies at time-scales down to 50 fs. The fully coherent nature of all these sources results in peak and average brightness values that are many orders of magnitude higher than storage rings. We acknowledge support from the Commonwealth of Virginia. Jefferson Lab is supported by the U.S. DOE under Contract No. DE-AC05-84-ER40150.

43 PARTICLE ACCELERATORS↗

White noise of Nb-based microwave superconducting quantum interference device multiplexers with NbN coplanar resonators for readout of transition edge sensors

White noise of dissipationless microwave radio frequency superconducting quantum interference device (RF-SQUID) multiplexers has been experimentally studied to evaluate their readout performance for transition edge sensor (TES) photon counters ranging from near infrared to gamma ray. The characterization has been carried out at 4 K, first to avoid the low-frequency fluctuations present at around 0.1 K, and second, for a feasibility study of readout operation at 4 K for extended applications. To increase the resonant Q at 4 K and maintain low noise SQUID operation, multiplexer chips consisting of niobium nitride (NbN)-based coplanar-waveguide resonators and niobium (Nb)-based RF-SQUIDs have been developed. This hybrid multiplexer exhibited 1 × 10{sup 4} ≤ Q ≤ 2 × 10{sup 4} and the square root of spectral density of current noise referred to the SQUID input √S{sub I} = 31 pA/√Hz. The former and the latter are factor-of-five and seven improvements from our previous results on Nb-based resonators, respectively. Two-directional readout on the complex plane of the transmission component of scattering matrix S{sub 21} enables us to distinguish the flux noise from noise originating from other sources, such as the cryogenic high electron mobility transistor (HEMT) amplifier. Systematic noise measurements with various microwave readout powers P{sub MR} make it possible to distinguish the contribution of noise sources within the system as follows: (1) The achieved √S{sub I} is dominated by the Nyquist noise from a resistor at 4 K in parallel to the SQUID input coil which is present to prevent microwave leakage to the TES. (2) The next dominant source is either the HEMT-amplifier noise (for small values of P{sub MR}) or the quantization noise due to the resolution of 300-K electronics (for large values of P{sub MR}). By a decrease of these noise levels to a degree that is achievable by current technology, we predict that the microwave RF-SQUID multiplexer can exhibit √S{sub I} ≤ 5 pA/√Hz, i.e., close to √S{sub I} of state-of-the-art DC-SQUID-based multiplexers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characteristics of a four element gyromagnetic nonlinear transmission line array high power microwave source

In this paper, a solid-state four element array gyromagnetic nonlinear transmission line high power microwave system is presented as well as a detailed description of its subsystems and general output capabilities. This frequency agile S-band source is easily adjusted from 2-4 GHz by way of a DC driven biasing magnetic field and is capable of generating electric fields of 7.8 kV/m at 10 m correlating to 4.2 MW of RF power with pulse repetition frequencies up to 1 kHz. Beam steering of the array at angles of ±16.7° is also demonstrated, and the associated general radiation pattern is detailed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influences of impedance matching network on pulse-modulated radio frequency atmospheric pressure glow discharges

Pulse-modulated RF atmospheric pressure glow discharges (APDGs) were investigated in recent years to reduce the thermal accumulation and extend the operation region of the stable alpha glow mode. Different pulse-modulated voltage and current waveforms were acquired in previous experiments, but no attention was paid to the interpretation. We investigated this issue and associated phenomenon via positive and negative feedback effects derived from varying the series capacitor in the inversely L-shaped matching network used in our pulse-modulated RF APGD source. The evolutions of pulse-modulated RF waveforms were found to be associated with the feedback region and the pulsed plasma absorbed RF power. In the positive feedback region, pulse-modulated RF APGDs are relatively stable. In the negative feedback region, wide spikes as well as undershoots occur in RF voltage and current waveforms and the plasma absorbed RF power. In case of a high RF power discharge with a low modulation frequency, the pulse-modulated RF APGD is extinguished and re-ignited due to the enhanced undershoot during the initial pulse phase. The pulse-modulated RF APGD can transit from positive to negative feedback region in a range of series capacitance. Experimental results are discussed by the aid of equivalent circuit, negative and positive feedback effects.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wall charging of a helicon antenna wrapped plasma filled dielectric tube

Dielectric wall charging of a cylindrical glass wall surrounded by a helicon antenna of 18 cm length is measured in a linear helicon plasma device with a diverging magnetic field. The ions because of their lesser mobility do not respond to the high frequency electric field and the electrons charge the wall to a negative DC potential also known as the DC self-bias. The wall potential in this device is characterized for different neutral pressure, magnetic field, and radio frequency (RF) power. Axial variation of wall potential shows higher self-bias potentials near the antenna rings. Ion magnetization in the source chamber increases both wall charging and plasma potential of the source due to confinement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel Co:MgF2 lidar for aerosol profiler

Lidars are of great interest because of their unique capabilities in remote sensing applications in sounding of the atmosphere, meteorology, and climatology. In this small business innovative research (SBIR) phase II program, laser sources including Co:MgF2, CTH:YAG, CTH:YSGG, CT:YAG, and Er:Glass were evaluated. Modulator of fused silica and TeO2 materials with Brewster's angle end faces were used with these lasers as acousto-optical (AO) Q-switches. A higher hold-off energy and hence a higher Q-switched energy was obtained by using a high power RF driver. The report provides performance characteristics of these lasers. The tunable (1.75-2.50 microns) Co:MgF2 laser damaged the TeO2 Q-switch cell. However, the CTH:YAG laser operating at 2.09 microns provided output energy of over 300 mJ/p in 50 ns pulse width using the fused silica Q-switch. This Q-switched CTH:YAG laser was used in a breadboard vertical aerosol profiler. A 40 cm diameter telescope, InSb and InGaAs detectors were used in the receiver. The data obtained using this lidar is provided in the report. The data shows that the eye safe lidar using CTH:YAG laser for the vertical aerosol density and range measurements is the viable approach.

Acharekar, M. A.↗

Effects of the shielding cylinder and substrate on the characteristics of an argon radio-frequency atmospheric glow discharge plasma jet

With unique features of low breakdown voltages, large and uniform discharge areas and high concentrations of chemically reactive species, radio-frequency, atmospheric-pressure glow discharge (rf APGD) plasma sources produced with bare-metallic electrodes have shown promising prospects in the field of materials processing. In this paper, the spatial distributions (i.e., the directly measured integrated axial distribution and the radial distribution by using the inverse Abel transform) of the emission intensities of the Ar I 696.5 nm line are studied for the argon rf APGD plasma jet under different operation conditions, including variations of the rf power input or the argon flow rate, the existence of the solid shielding cylinder or the substrate. The experimental results show that, with other parameters being unchanged, the emission intensities of the Ar I 696.5 nm line increase with increasing the rf power input or the argon flow rate; and the solid shielding cylinder has more significant influences on the characteristics of the plasma impinging jet by reducing the mass flow rate of the ambient air entrained into the plasma jet region than those for the cases without the existence of the substrate at the downstream of the plasma torch nozzle exit.

36 MATERIALS SCIENCE↗

THE PROJECT-X INJECTOR EXPERIMENT: A NOVEL HIGH PERFORMANCE FRONT-END FOR A FUTURE HIGH POWER PROTON FACILITY AT FERMILAB

A multi-MW proton facility, Project X, has been proposed and is currently under development at Fermilab. We are carrying out a program of research and development aimed at integrated systems testing of critical components comprising the front end of Project X. This program, known as the Project X Injector Experiment (PXIE), is being undertaken as a key component of the larger Project X R&D program. The successful completion of this program will validate the concept for the Project X front end, thereby minimizing a primary technical risk element within Project X. PXIE is currently under construction at Fermilab and will be completed over the period FY12-17. PXIE will include an H* ion source, a CW 2.1-MeV RFQ and two superconductive RF (SRF) cryomodules providing up to 25 MeV energy gain at an average beam current of 1 mA (upgradable to 2 mA). Successful systems testing will also demonstrate the viability of novel front end technologies that are expected find applications beyond Project X.

43 PARTICLE ACCELERATORS↗

Extracted ion current density in close-coupling multi-antenna type radio frequency driven ion source: CC-MATIS

Positive ions are extracted by using a small extractor from the Close-Coupling Multi-Antenna Type radio frequency driven Ion Source. Two types of RF antenna are used. The maximum extracted ion current density reaches 0.106 A/cm{sup 2}. The RF net power efficiency of the extracted ion current density under standard condition is 11.6 mA/cm{sup 2}/kW. The efficiency corresponds to the level of previous beam experiments on elementary designs of multi-antenna sources, and also to the efficiency level of a plasma driven by a filament in the same chamber. The multi-antenna type RF plasma source is promising for all metal high density ion sources in a large volume chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultracompact Accelerator Technology for a Next-Generation Gamma-Ray Source

This presentation reported on the technology choices and progress manufacturing and testing the injector and accelerator of the 250 MeV ultra-compact Compton Scattering gamma-ray Source under development at LLNL for homeland security applications. This paper summarizes the status of various facets of current accelerator activities at LLNL. The major components for the X-band test station have been designed, fabricated, and await installation. The XL-4 klystron has been delivered, and will shortly be dressed and installed in the ScandiNova modulator. High power testing of the klystron into RF loads will follow, including adjustment of the modulator for the klystron load as necessary. Assembly of RF transport, test station supports, and accelerator components will follow. Commissioning will focus on processing the RF gun to full operating power, which corresponds to 200 MV/m peak electric field on the cathode surface. Single bunch benchmarking of the Mark 1 design will provide confidence that this first structure operates as designed, and will serve as a solid starting point for subsequent changes, such as a removable photocathode, and the use of various cathode materials for enhanced quantum efficiency. Charge scaling experiments will follow, partly to confirm predictions, as well as to identify important causes of emittance growth, and their scaling with charge. Multi-bunch operation will conclude testing of the Mark 1 RF gun, and allow verification of code predictions, direct measurement of bunch-to-bunch effects, and initial implementation compensation mechanisms. Modeling will continue and focus on supporting the commissioning and experimental program, as well as seeking to improve all facets of linac produced Compton gamma-rays.

42 ENGINEERING↗

Recent Performance and Ignition Tests of the pulsed SNS H- Source for 1-MW Neutron Production

After acquiring several reliable spare targets, SNS ramped the beam power from 850 kW to 1.4 MW, which required an increase in H- beam pulse length from 0.88 to 1.0 ms at 60 Hz. This increase initially produced slow 2-MHz power ramp-ups and, after several weeks of uninterrupted operation, it produced plasma outages every time the pulse length was raised above ~0.95 ms. Similar outages were previously observed towards the end of long service cycles, which were believed to indicate that the breakdown voltage of the high purity hydrogen started to exceed the induced electric fields. In 2011 the RF was reconfigured to start with 10 cycles of 1.96 MHz, which yielded the shortest H- beam rise times and apparently eliminated those plasma outages. The new, pulse-length dependent outages were eliminated by increasing the initial frequency to 1.985 MHz. However, careful frequency studies are unable to justify this frequency. In addition, the paper discusses the issues and solutions for the electron-dump voltage, which starts to sag and become unstable after several weeks of high current operation.

43 PARTICLE ACCELERATORS↗

Study of RF breakdown and multipacting in accelerator components

Radio frequency (RF) structures that are part of accelerators and energy sources, operate with sinusoidally varying electromagnetic fields under high RF energy. Here, RF breakdown and multipacting take place in RF structures and limit their performance. Electron field emission processes in a RF structure are precursors for breakdown processes. RF breakdown is a major phenomena affecting and causing the irreversible damage to RF structures. Breakdown rate and the damage induced by the breakdowns are its important properties. The damage is related to power absorbed during breakdown, while the breakdown rate is determined by the amplitudes of surface electric and magnetic fields, geometry, metal surface preparation and conditioning history. It limits working power and produces irreversible surface damage. The breakdown limit depends on the RF circuit, structure geometry, RF frequency, input RF power, pulse width, materials used, surface processing technique and surface electric and magnetic fields. Multipactor (MP) is a low power, electron multiplication based resonance breakdown phenomenon in vacuum and is often observed in RF structures. A multipactor discharge is undesirable, as it can create a reactive component that detunes the resonant cavities and components, generates noise in communication system and induces gas desorption from the conductor surfaces. In RF structures, certain conditions are required to generate multipacting. (author)

43 PARTICLE ACCELERATORS↗

Physics and technology of high-brightness high-power photoinjectors for beam coolers and electron ion colliders

This projected involved two main areas for advancing R&D progress towards an electron-ion collider as it pertains to the requirements of the electron sources: 1) demonstration of the bunch parameters and beam quality out of the photoinjector required for beam cooling and 2) characterizing secondary ion effects in high power beams with investigation of strategies for ion mitigation. These research topics were addressed using simulations and beam experiments performed at the Cornell high average current low emittance photoinjector that uses a high voltage DC photoemission gun and a cryomodule with 5 superconducting RF cavities for the energy booster.

43 PARTICLE ACCELERATORS↗