Search NASA⌕ Search

SEARCH · Search NASA

Results for “High dynamic range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Testing of A Photon-Counting Optical Ground Receiver With Emulated Space-to-Ground Link Effects

The National Aeronautics and Space Administration (NASA) Glenn Research Center (GRC) developed and previously characterized a photon-counting optical ground receiver system. The receiver is compliant with the Consultative Committee for Space Data Systems (CCSDS) Optical Communications Coding and Synchronization High Photon Efficiency (HPE) Standard. The standard will be used on the Optical Artemis-2 Orion (O2O) communications demonstration and the Deep Space Optical Communication (DSOC) project aboard the Psyche spacecraft. The receiver system consists of a fiber interconnect, up to sixteen superconducting nanowire single-photon detectors (SNSPDs), and a field programmable gate array (FPGA) based receive modem. Previously, the receiver system architecture was described and test results without emulated link effects were presented. SNSPD device properties, which impact detection jitter and time delay, can limit the receiver dynamic range, especially when operating with varying flux rates (>10 dB) between detectors. Codeword error-rate curves with and without simulated clock drifts attributed to Doppler shift and space transmitter clock differences are presented. Results with ±66 ppm clock differences show minimal performance impact (<0.2 dB). Test results show that the receiver dynamic range (>28 dB) is limited by changing SNSPD detection delays at high photon flux rates.

optical communications↗

Molecular theory capability: LANL-PEM-Atomic implements universal descriptions of molecular photoionization

Photoionization of atomic ions, the process through which atoms in bound states absorb radiation by losing electrons, is a vital part of describing radiative transfer in mission-relevant dynamics. The photoionization of molecules dominates radiative transfer of ultraviolet (UV) and extreme UV (EUV) radiation in colder atmospheres (temperature < 30,000 degrees Kelvin). Consequently, air, which is quite transparent to our eyes (i.e., in the visible frequency regime) is remarkably opaque to radiation in much of the UV and EUV frequency regimes. This opacity makes air and other gas systems quite efficient at absorbing UV and EUV radiation, which heats the gas until ionization makes it transparent. This effect is important in describing a host of relevant phenomena, ranging from charge separation in high-altitude nuclear events and the dynamics of a nuclear fireball to the electrostatic discharges (sparks) that complicate weapons disassembly at Pantex.

74 ATOMIC AND MOLECULAR PHYSICS↗

A quick response four decade logarithmic high-voltage stepping supply

An improved high-voltage stepping supply, for space instrumentation is described where low power consumption and fast settling time between steps are required. The high-voltage stepping supply, utilizing an average power of 750 milliwatts, delivers a pair of mirror images with 64 level logarithmic outputs. It covers a four decade range of + or - 2500 to + or - 0.29 volts having an output stability of + or - 0.5 percent or + or - 20 millivolts for all line load and temperature variations. The supply provides a typical step setting time of 1 millisecond with 100 microseconds for the lower two decades. The versatile design features of the high-voltage stepping supply provides a quick response staircase generator as described or a fixed voltage with the option to change levels as required over large dynamic ranges without circuit modifications. The concept can be implemented up to + or - 5000 volts. With these design features, the high-voltage stepping supply should find numerous applications where charged particle detection, electro-optical systems, and high voltage scientific instruments are used.

Doong, H.↗

New broadband square-law detector

Compact device has wide dynamic range, accurate square-law response, good thermal stability, high-level dc output with immunity to ground-loop problems, ability to insert known time constants for radiometric applications, and fast response times compatible with computer systems.

Reid, M. S.↗

Virtual phase imager for Galileo

A CCD imaging array with a new virtual-phase technology that has been developed for use in a slow-scan imaging system for NASA's Galileo mission to Jupiter is described. Among its features are an absence of interlevel shorts, simplicity of fabrication, low dark current (less than 0.4 nA/sq cm), high full well, high quantum efficiency in the front side illumination mode, large dynamic range (greater than 5000), good charge transfer efficiency (0.99997), excellent linearity (0.2%), uniform pixel response (1%), and improved radiation hardness. It is noted that its operating voltages must be constrained to narrow windows to maintain good charge transfer efficiency and avoid the production of spurious and leakage charge.

Janesick, J. R.↗

Solar maximum mission: Ground support programs at the Harvard Radio Astronomy Station

Observations of the spectral characteristics of solar radio bursts were made with new dynamic spectrum analyzers of high sensitivity and high reliability, over the frequency range 25-580 MHz. The observations also covered the maximum period of the current solar cycle and the period of international cooperative programs designated as the Solar Maximum Year. Radio data on shock waves generated by solar flares were combined with optical data on coronal transients, taken with equipment on the SMM and other satellites, and then incorporated into computer models for the outward passage of fast-mode MHD shocks through the solar corona. The MHD models are non-linear, time-dependent and for the most recent models, quasi-three-dimensional. They examine the global response of the corona for different types of input pulses (thermal, magnetic, etc.) and for different magnetic topologies (for example, open and closed fields). Data on coronal shocks and high-velocity material ejected from solar flares have been interpreted in terms of a model consisting of three main velocity regimes.

Maxwell, A.↗

Optical and electrical measurements on UV sensitive photodiodes

The optical and electrical characteristics of the various types of photodiodes potentially useful for UV radiometers were studied. It was concluded that both GaAsP and GaP photodiodes have advantages over silicon photodiodes in terms of spectral response and UV stability. Both GaAsP and GaP have excellent electrical characteristics for low frequency radiometers, although their high capacitance could be inconvenient for high frequency applications. GaAsP is particularly good with respect to dynamic range.

Lyall, H.↗

A 1- to 10-GHz downconverter for high-resolution microwave survey

A downconverter was designed, built, and tested for the High Resolution Microwave Survey project. The input frequency range is 1 to 10 GHz with instantaneous bandwidth of 350 MHz and dynamic range of 125 dB/Hz. Requirements were derived for the local oscillators and special design techniques were implemented to achieve the high degree of spectral purity required.

Mcwatters, D.↗

Intracavity Rayleigh/Mie Scattering for Multipoint, Two-Component Velocity Measurement

A simultaneous multi-point two-component Doppler velocimeter is described. The system uses two optical cavities: a Fabry-Perot etalon and an optical cavity for collecting and re-circulating the Rayleigh/Mie scattered light that is collected from the measurement volume in two parallel, but opposite directions. Single-pulse measurements of two orthogonal components of the velocity vector in a supersonic free jet were performed to demonstrate the technique. The re-circulation of the light rejected by the interferometer input mirror also increased the signal intensity by a factor of 3.5. 2005 Optical Society of America Interferometric Rayleigh scattering has previously been used for single-point velocity measurements in unseeded gas flow. However, this past work has generally been limited to probing with continuous-wave lasers resulting in time-averaged measurements of velocity. Multiple velocity components have been measured simultaneously by separate instruments.1,2 It has also been demonstrated that two orthogonal velocity components can be measured simultaneously at one point using one interferometer by reflecting back the probing laser beam, although this approach results in directional ambiguity of the flow velocity vector.3 This measurement ambiguity was removed by prior knowledge of the approximate magnitude and sign of the velocity components. Furthermore, it was shown that multiple points could be measured simultaneously with a Rayleigh scattering interferometric approach, but only one component of velocity was measured.4 Another method of performing multiple component velocity measurements with Rayleigh scattering uses a pair of cameras to image the flow, one of which views the flow through an iodine gas filter. This iodine-filter technique has the advantage of allowing high-resolution velocity imaging, but it generally has a lower dynamic range.

Bivolaru, Daniel↗

Comparison of 16-Channel Laser Photoreceivers for Topographic Mapping

Topographic mapping lidar instruments must be able to detect extremely weak laser return signals from high altitudes including orbital distance. The signals have a wide dynamic range caused by the variability in atmospheric transmission and surface reflectance under a fast moving spacecraft. Ideally, lidar detectors should be able to detect laser signal return pulses at the single photon level and produce linear output for multiple photon events. Silicon avalanche photodiode (APO) detectors have been used in most space lidar receivers to date. Their sensitivity is typically hundreds of photons per pulse, and is limited by the quantum efficiency, APO gain noise, dark current, and preamplifier noise. NASA is pursuing three approaches for a 16-channel laser photoreceiver for use on the next generation direct-detection airborne and spacebome lidars. We present our measurement results and a comparison of their performance.

Krainak, Michael A.↗

Assessment of VIIRS Day-Night Band High Gain Calibration Using Stars

The VIIRS has a unique spectral band that can sense reflected light from space during both day and nighttime, thus referred to as the day-night band (DNB). This band operates in three different gain stages: low, mid, and high gain (LG, MG, and HG) that cover a remarkable dynamic range with its HG stage being extremely sensitive to low-light scenes. Similar to its reflective solar bands, the VIIRS uses an on-board solar diffuser for its DNB LG stage calibration, whereas the DNB MG and HG calibrations are performed using relative or ratioing approaches. In this paper, we provide an assessment of VIIRS DNB HG calibrations using stars that appear in the field-of-view of its space view (SV), focusing on the computation of the gain trending and associated tool development. We also describe various strategies and procedures developed for DNB HG calibration stability monitoring and inter-comparisons among different VIIRS instruments and discuss some of the complications and limits to this approach, including under-sampling of the stellar image, saturation, and crowding. For S-NPP VIIRS, it includes the use of the modulated relative spectral response (RSR) resulting from wavelength-dependent degradation of the sensor optics. Results show that the star-based response trending for the DNB HG is consistent with that derived from on-board solar diffuser and that the calibration difference between S-NPP and N-20 VIIRS DNB requires additional effort to address, especially for research studies and applications using data from both sensors.

VIIRS↗

Magnetosphere Evolution and Precursor-driven Electromagnetic Signals in Merging Binary Neutron Stars

We detail new force-free simulations to investigate magnetosphere evolution and precursor electromagnetic (EM) signals from binary neutron stars. Our simulations fully follow a representative inspiral motion, capturing the intricate magnetospheric dynamics and their impact on EM outflows. We explore a range of stellar magnetic moment orientations and relative strengths, finding that the magnetospheres and Poynting flux evolution are strongly configuration dependent. The Poynting flux exhibits pulsations at twice the orbital frequency, 2Ω, and is highly anisotropic, following a power-law dependence on orbital frequency. The index ranges from 1 to 6, shaped by the intricate dynamics of the magnetospheres. Furthermore, we present the first computation of (1) the EM forces acting on the star surfaces, revealing the presence of torques that, for highly magnetized stars, could influence the orbital dynamics or break the crust; (2) the high-energy emission signals from these systems by adopting the established isolated pulsar theory. Assuming curvature radiation in the radiation-reaction limit, we find that photons could reach TeV–PeV energies in the last ∼ms for magnetic field strengths 10 10 –10 15 G. However, our analysis of single photon magnetic pair production suggests that these photons are unlikely to escape, with the MeV band emerging as a promising observational window for precursor high-energy emission. In this framework, we construct high-energy emission skymaps and light curves, exploring observational implications. Finally, we propose potential precursor radio emission and delayed afterglow echoes from magnetized outflows, which may contribute to late-time rebrightening in short gamma-ray bursts or to orphan afterglows.

79 ASTRONOMY AND ASTROPHYSICS↗

Dynamics of Molecular Hydrogen in Hypersaline Microbial Mars

Early Earth microbial communities that centered around the anaerobic decomposition of organic molecular hydrogen as a carrier of electrons, regulator of energy metabolism, and facilitator of syntroph'c microbial interactions. The advent of oxygenic photosynthetic organisms added a highly dynamic and potentially dominant term to the hydrogen economy of these communities. We have examined the daily variations of hydrogen concentrations in cyanobacteria-dominated microbial mats from hypersaline ponds in Baja California Sur, Mexico. These mats bring together phototrophic and anaerobic bacteria (along with virtually all other trophic groups) in a spatially ordered and chemically dynamic matrix that provides a good analog for early Earth microbial ecosystems. Hydrogen concentrations in the photic zone of the mat can be three orders of magnitude or more higher than in the photic zone, which are, in turn, an order of magnitude higher than in the unconsolidated sediments underlying the mat community. Within the photic zone, hydrogen concentrations can fluctuate dramatically during the diel (24 hour day-night) cycle, ranging from less than 0.001% during the day to nearly 10% at night. The resultant nighttime flux of hydrogen from the mat to the environment was up to 17% of the daytime oxygen flux. The daily pattern observed is highly dependent on cyanobacterial species composition within the mat, with Lyngbya-dominated systems having a much greater dynamic range than those dominated by Microcoleus; this may relate largely to differing degrees of nitrogen-fixing and fermentative activity in the two mats. The greatest H2 concentrations and fluxes were observed in the absence of oxygen, suggesting an important potential feedback control in the context of the evolution of atmospheric composition. The impact of adding this highly dynamic photosynthetic term to the hydrogen economy of early microbial ecosystems must have been substantial. From an evolutionary standpoint, the H2 generated in mats could have represented a very important new source of electrons and energy - but one that could not be harnessed without substantial adaptation to the highly variable chemistry of the mat surface. In addition, the emergent chemistry of anaerobic communities is often highly dependent on ambient hydrogen concentrations, so that incorporation of these communities into photosynthetic mats could have significantly affected the composition and flux of reduced "biosignature' gases to the environment.

Hoehler, Tori M.↗

Effects of whole body heating on dynamic baroreflex regulation of heart rate in humans

The purpose of this project was to identify whether dynamic baroreflex regulation of heart rate (HR) is altered during whole body heating. In 14 subjects, dynamic baroreflex regulation of HR was assessed using transfer function analysis. In normothermic and heat-stressed conditions, each subject breathed at a fixed rate (0. 25 Hz) while beat-by-beat HR and systolic blood pressure (SBP) were obtained. Whole body heating significantly increased sublingual temperature, HR, and forearm skin blood flow. Spectral analysis of HR and SBP revealed that the heat stress significantly reduced HR and SBP variability within the high-frequency range (0.2-0.3 Hz), reduced SBP variability within the low-frequency range (0.03-0.15 Hz), and increased the ratio of low- to high-frequency HR variability (all P < 0.01). Transfer function gain analysis showed that the heat stress reduced dynamic baroreflex regulation of HR within the high-frequency range (from 1.04 +/- 0.06 to 0.54 +/- 0.6 beats. min(-1). mmHg(-1); P < 0.001) without significantly affecting the gain in the low-frequency range (P = 0.63). These data suggest that whole body heating reduced high-frequency dynamic baroreflex regulation of HR associated with spontaneous changes in blood pressure. Reduced vagal baroreflex regulation of HR may contribute to reduced orthostatic tolerance known to occur in humans during heat stress.

Non-NASA Center↗

The construction of a highly transportable laser ranging station

The technology of the transportable Laser Ranging Station (TLRS) used in crustal dynamics studies was examined. The TLRS used a single photoelectron beam of limited energy density returned from the Laser Geodynamic Satellite (LAGEOS). Calibration was accomplished by the diversion of a small portion of the outgoing beam attenuated to the same level as the satellite return. Timing for the system was based on a self calibrating Ortec TD811, 100 picosec time interval device. The system was contained in a modified, single chassis recreational vehicle that allowed rapid deployment. The TLRS system was only airmobile on the largest transport aircraft. A 30 cm simple plano/concave transfer lens telescope aided in beam direction. The TLRS system fulfills the need for an accurate method of obtaining range measurements to the LAGEOS satellite incorporated in a mobile, air transportable, and economical configuration.

Source record↗

Methods for Reducing Singly Reflected Rays on the Wolter-I Focusing Figures of the FOXSI Rocket Experiment

In high energy solar astrophysics, imaging hard X-rays by direct focusing offers higher dynamic range and greater sensitivity compared to past techniques that used indirect imaging. The Focusing Optics X-ray Solar Imager (FOXSI) is a sounding rocket payload which uses seven sets of nested Wolter-I figured mirrors that, together with seven high-sensitivity semiconductor detectors, observes the Sun in hard X-rays by direct focusing. The FOXSI rocket has successfully flown twice and is funded to fly a third time in Summer 2018. The Wolter-I geometry consists of two consecutive mirrors, one paraboloid, and one hyperboloid, that reflect photons at grazing angles. Correctly focused X-rays reflect twice, once per mirror segment. For extended sources, like the Sun, off-axis photons at certain incident angles can reflect on only one mirror and still reach the focal plane, generating a pattern of single-bounce photons that can limit the sensitivity of the observation of faint focused X-rays. Understanding and cutting down the singly reflected rays on the FOXSI optics will maximize the instrument's sensitivity of the faintest solar sources for future flights. We present an analysis of the FOXSI singly reflected rays based on ray-tracing simulations, as well as the effectiveness of different physical strategies to reduce them.

FOXSI Rocket Experiment↗

Simultaneous quantification of poly-dispersed anionic, amphoteric and nonionic surfactants in simulated wastewater samples using C18 high-performance liquid chromatography-quadrupole ion-trap mass spectrometry

This paper describes the development of a guantitative method for direct and simultaneous determination of three frequently encountered surfactants, amphoteric (cocoamphoacetate, CAA), anionic (sodium laureth sulfate, SLES), and nonionic (alcohol ethoxylate, AE) using a reversed-phase C18 HPLC coupled with an ESI ion-trap mass spectrometer (MS). Chemical composition, ionization characteristics and fragmentation pathways of the surfactants are presented. Positive ESI was effective for all three surfactants in agueous methanol buffered with ammonium acetate. The method enables rapid determinations in small sample volumes containing inorganic salts (up to 3.5 g L(-1)) and multiple classes of surfactants with high specificity by applying surfactant specific tandem mass spectrometric strategies. It has dynamic linear ranges of 2-60, 1.5-40, 0.8-56 mg L(-1) with R2 egual or greater than 0.999, 0.98 and 0.999 (10 microL injection) for CAA, SLES, and AE, respectively.

Chromatography, High Pressure Liquid/methods↗