Search NASA⌕ Search

SEARCH · Search NASA

Results for “Hydrogen Concentrations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Lunar neutron leakage fluxes as a function of composition and hydrogen content

Areas of the moon that might have enhanced concentrations of hydrogen are discussed. The fluxes of thermal, epithermal, and fast neutrons escaping from the lunar surface were calculated for eight different compositions and several hydrogen contents. These flux ratios depend on composition and are very sensitive to the hydrogen content. Their measurement using flight-proven techniques from lunar orbit should allow detection and identification of hydrogen residing in either permanently shaded cold traps near the lunar poles or mature regoliths. Knowledge of composition, especially of Fe and Ti, improves the thresholds for hydrogen detection and also could allow identification of Gd and Sm.

Feldman, W. C.↗

Concentrating on solar for hydrogen

Hydrogen generated by sunlight could play a major role in a low-carbon future, but high-efficiency demonstrations have been limited mostly to very small scales. New research now evaluates a complete system that generates 0.5 kg of hydrogen per day with 20% device (5.5% system) efficiency while showing the benefits of coupled light absorption and water electrolysis.

08 HYDROGEN↗

Optimizing semi-hydrogenation of unsaturated hydrocarbons by electrolyte engineering approach

Electrochemical hydrogenation of unsaturated hydrocarbons, when powered by renewables, represents a unique opportunity to substitute current energy-intensive synthetic routes. Modulation of adsorption energies of the organic substrate and key intermediates of the reaction is critical for fine tuning of the yield, selectivity and kinetics of the reaction. Interestingly, mounting evidence exists regarding the role of electrolyte composition in the outcome of semi-hydrogenation reactions. Nevertheless, electrolyte optimization is a complex task, owing to its hybrid nature. Indeed, it is composed of water serving as a proton source, an organic solvent necessary to dissolve the organic substrate and a conducting salt. Herein, we demonstrate that varying conducting salt and organic solvent has a dramatic impact on the outcomes of semi-hydrogenation of alkynes. By varying salt and water concentrations, we demonstrate that water does not serve as a proton source, and instead addition of an acid is necessary. While increasing the acid concentration increases the yield of the reaction, at too large concentrations the hydrogen evolution reaction becomes predominant. Furthermore, by combining electrochemical measurements with spectroscopic techniques including Fourier transform infrared (FTIR) spectroscopy and small angle X-ray spectroscopy (SAXS), we demonstrate that the electrolyte solvation structure dramatically impacts the yield of the reaction. Organic solvents weakly interacting with water, including acetonitrile, form aqueous nanoheterogeneities that prevent the organic substrate from accessing the catalyst interface and thus lead to limited yields. Instead, solvents such as dimethylformamide form homogeneous mixtures with which all reactants can access the interface, leading to yields greater than 80% for optimized compositions.

Zhang, Rongyu↗

A High-Temperature Multipoint Hydrogen Sensor Using an Intrinsic Fabry–Perot Interferometer in Optical Fiber

This paper presents a multiplexable fiber optic chemical sensor with the capability of monitoring hydrogen gas concentration at high temperatures up to 750 °C. The Pd-nanoparticle infused TiO 2 films coated on intrinsic Fabry–Perot interferometer (IFPI) array were used as sensory films. Strains induced upon exposure to hydrogen with varied concentrations can be monitored by IFPI sensors. The fiber sensor shows a repetitive and reversible response when exposed to a low level (1–6%) of hydrogen gas. Uniform sensory behavior across all the sensing cavities is demonstrated and reported in this paper.

47 OTHER INSTRUMENTATION↗

Considerations for Storage of High Test Hydrogen Peroxide (HTP) Utilizing Non-Metal Containers

When working with high concentrations of hydrogen peroxide, it is critical that the storage container be constructed of the proper materials, those which will not degrade to the extent that container breakdown or dangerous decomposition occurs. It has been suggested that the only materials that will safely contain the peroxide for a significant period of time are metals of stainless steel construction or aluminum use as High Test Hydrogen Peroxide (HTP) Containers. The stability and decomposition of HTP will be also discussed as well as various means suggested in the literature to minimize these problems. The dangers of excess oxygen generation are also touched upon.

Moore, Robin E.↗

Evidence for the Sequestration of Hydrogen-Bearing Volatiles Towards the Moons Southern Pole-Facing Slopes

The Lunar Exploration Neutron Detector (LEND) onboard the Lunar Reconnaissance Orbiter (LRO) detects a widespread suppression of the epithermal neutron leakage flux that is coincident with the pole-facing slopes (PFS) of the Moon's southern hemisphere. Suppression of the epithermal neutron flux is consistent with an interpretation of enhanced concentrations of hydrogen-bearing volatiles within the upper meter of the regolith. Localized flux suppression in PFS suggests that the reduced solar irradiation and lowered temperature on PFS constrains volatility to a greater extent than in surrounding regions. Epithermal neutron flux mapped with LEND's Collimated Sensor for Epithermal Neutrons (CSETN) was analyzed as a function of slope geomorphology derived from the Lunar Orbiting Laser Altimeter (LOLA) and the results compared to co-registered maps of diurnally averaged temperature from the Diviner Lunar Radiometer Experiment and an averaged illumination map derived from LOLA. The suppression in the average south polar epithermal neutron flux on equator-facing slopes (EFS) and PFS (85-90 deg S) is 3.3 +/- 0.04% and 4.3 +/- 0.05% respectively (one-sigma-uncertainties), relative to the average count-rate in the latitude band 45-90 deg S. The discrepancy of 1.0 +/- 0.06% between EFS and PFS neutron flux corresponds to an average of approximately 23 parts-per-million-by-weight (ppmw) more hydrogen on PFS than on EFS. Results show that the detection of hydrogen concentrations on PFS is dependent on their spatial scale. Epithermal flux suppression on large scale PFS was found to be enhanced to 5.2 +/- 0.13%, a discrepancy of approximately 45 ppmw hydrogen relative to equivalent EFS. Enhanced poleward hydration of PFS begins between 50 deg S and 60 deg S latitude. Polar regolith temperature contrasts do not explain the suppression of epithermal neutrons on pole-facing slopes. The Supplemental on-line materials include supporting results derived from the uncollimated Lunar Prospector Neutron Spectrometer and the LEND Sensor for Epithermal Neutrons.

Ices↗

Apparatus For Tests Of Embrittlement By Hydrogen

Test apparatus exposes disk specimens to hydrogen in controlled, repeatable way simulating conditions in use. Disk specimen constitutes thin wall between pressure and vacuum chambers. Test proceeds until hydrogen weakens disk enough that it ruptures. Aluminum impact plate absorbs debris from ruptured disk. Apparatus replicates aspects of service environments relevant to embrittlement by hydrogen in such equipment as storage tanks, valves, and fluid-handling components containing hydrogen at high absolute or gauge pressure. Hydrogen inside permeates stressed material and produces gradient of concentration as hydrogen diffuses through material to low-pressure side.

Christianson, Rollin C.↗

Charge trapping at Al/Al 2 ⁢O 3 interface facilitates hydrogen-induced superabundant metal vacancy formation

Hydrogen is a ubiquitous impurity that deteriorates the metal/oxide interface, causing challenges such as current leakage and blistering. Here, in this work, we uncover the mechanisms behind hydrogen-induced damage at the prototypical Al/A⁢l 2 ⁢O 3 interface. The precursor that we identify is charge trapping at the interface, which facilitates hydrogen segregation to the interface plane as H – . Presence of hydrogen increases aluminum vacancy concentration at the interfacial metal and oxide planes. Each Al vacancy can trap multiple hydrogen atoms. As a result, the interfacial aluminum vacancy and hydrogen concentrations increase by orders of magnitude. Additionally, hydrogen behaves as an n-type dopant and increases electronic conductivity at the oxide layer adjacent to the interface by forming H + , and the [V Al –H] complex is the predominant defect at this layer. These findings provide the precursor mechanisms of hydrogen-induced damage at the metal-oxide interfaces and have implications for advancing Al/A⁢l 2 ⁢O 3 –based coatings and electronic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heterogeneous oxidation of hydrogen-natural gas blends in a safe, clean, and efficient burner design

The growth of hydrogen as an alternative clean fuel for fulfilling thermal energy needs of multiple economic sectors globally requires access to reliable, safe, energy efficient, emission free combustion technology. The work described in this short communication shows the applicability of a novel heterogeneous combustion design in utilizing a wide range of hydrogen blended methane concentrations to cleanly and safely generate thermal energy. The utilization of a simple first principles design approach along with engineered materials yielded a fuel-flexible hybrid infrared-convection burner design capable of lowering NOx emissions by more than 95% while simultaneously improving the heat transfer efficiency by 15% with a wide range of hydrogen concentrations. Here, the safety and performance of the combustion design was demonstrated in an burner at capacities of up to 12,000 Btu/h in producing temperatures of 900 °C. The atmospheric burner concept was integrated in a cooktop configuration with combined thermal power rating of 30,000 Btu/h and operated with hydrogen blended natural gas.

08 HYDROGEN↗

The effect of hydrogen and microstructure on the deformation and fracture behavior of a single crystal nickel-base superalloy

A study was conducted on the effects of internal hydrogen and microstructure on the deformation and fracture of a single crystal nickel-base superalloy. In particular, room temperature plane strain fracture toughness and tensile tests were performed on hydrogen-free and hydrogen charged samples of PWA 1480. The role of microstructure was incorporated by varying the levels of porosity and eutectic gamma/gamma prime through hot isostatic pressing and heat treatment. The room temperature behavior of PWA 1480 was unusual because precipitate shearing was not the primary deformation mechanism at all strains. At strains over 1 percent, dislocations were trapped in the gamma matrix and an attempt was made to relate this behavior to compositional differences between PWA 1480 and other superalloys. Another unique feature of the tensile behavior was cleavage of the eutectic gamma/gamma prime, which is believed to initiate the failure process. Fracture occurred on (111) planes and is likely a result of shear localization along these planes. Elimination of the eutectic gamma/gamma prime greatly improved the tensile ductility, but pososity had no effect on tensile properties. Large quantities of hydrogen (1.74 at. percent) were gas-phase charged into the material, but surprisingly this was not a function of the amount of porosity or eutectic gamma/gamma prime present. Desorption experiments suggest that the vast majority of hydrogen is at reversible lattice trapping sites. This large, uniform concentration of hydrogen dramatically reduced the tensile strain to failure, but only slightly affected the reduction in area. Available hydrogen embrittlement models were examined in light of these results and it was found that the hydrogen enhanced localized plasticity model can explain much of the tensile behavior. K(IC) fracture toughness tests were conducted, but it was necessary to also perform J(IC) tests to provide valid data.

Walston, William S.↗

Some effects of combustion on turbulent mixing

Ceramic-heated tunnel experiments were performed to study mixing and combustion of near-sonic central hydrogen jets and coaxial supersonic air or nitrogen streams. Results of concentration measurements in these flows are presented. Larger concentrations of hydrogen were observed near the axis in the presence of combustion. Results of flowfield calculations and of low-speed free jet experiments reported by Chigier and Strokin (1974) suggest that this behavior is caused primarily by lower density in the burning case producing lower turbulent mass transport coefficients.

Bangert, L. H.↗