Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Formation of misfit dislocation arrays and helium nanochannels near copper surface assisted by high-temperature graphene deposition

Misfit dislocation arrays (MDAs) at semi-coherent heterogeneous interface have been demonstrated effectiveness to trap and then outgas helium (He) for alleviating void swelling in metals, but limited by atomic-level thin film deposition that is difficult to scale-up for industrial production. In this work, we proposed an innovative strategy that could generate semi-coherent homophase interfaces in a same grain by varying surface energy density assisted by high-temperature graphene (Gr) deposition. This strategy transforms strain energy and surface energy, two originally distinctive processes into successive processes, and demonstrates experimentally and theoretically by introducing {111} copper (Cu) in a {100} Cu grain. Subsequent He implantation and electrical resistivity measurement results suggest that high-density MDAs originated at this {111}/{100} interface could form stable He nanochannels near Cu surface with Gr assistance, manifesting by ultra-low increased ratio of the electrical resistivity (i.e. ~3800% of Cu vs. ~90% of Gr/Cu) after He implantation. Finally, the present findings may provide a new strategy for efficiently managing He and achieving surface protection of advanced metals, merely by depositing a super-rigid material on metal surface to greatly reduce surface energy density.

36 MATERIALS SCIENCE↗

Tungsten disulfide nanotubes enhance flow-induced crystallization and radio-opacity of polylactide without adversely affecting in vitro toxicity

Treatment of vascular disease, from peripheral ischemia to coronary heart disease (CHD), is poised for transformation with the introduction of transient implants designed to “scaffold” regeneration of blood vessels and ultimately leave nothing behind. Improved materials could expand the use of these devices. Here, we examine one of the leading polymers for bioresorbable scaffolds (BRS), polylactide (PLA), as the matrix of nanocomposites with tungsten disulfide (WS 2 ) nanotubes (WSNT), which may provide mechanical reinforcement and enhance radio-opacity. We evaluate in vitro cytotoxicity using vascular cells, flow-induced crystallization and radio-opacity of PLA-WSNT nanocomposites at low WSNT concentration. A small amount of WSNT (0.1 wt%) can effectively promote oriented crystallization of PLA without compromising molecular weight. And radio-opacity improves significantly: as little as 0.5 to 1 wt% WSNT doubles the radio-opacity of PLA-WSNT relative to PLA at 17 keV. The results suggest that a single component, WSNT, has the potential to increase the strength of BRS to enable thinner devices and increase radio-opacity to improve intraoperative visualization. Here, the in vitro toxicity results indicate that PLA-WSNT nanocomposites are worthy of investigation in vivo. Although substantial further preclinical studies are needed, PLA-WSNT nanocomposites may provide a complement of material properties that may improve BRS and expand the range of lesions that can be treated using transient implants.

36 MATERIALS SCIENCE↗

Predicting displacement damage for ion irradiation: Origin of the overestimation of vacancy production in SRIM full-cascade calculations

Ion irradiation and implantation have wide applications that demand accurate determination of displacement damage profile and distribution of implanted ion concentration. The prediction of vacancies is especially important to determine displacements per atom (dpa), the standard parameter of primary radiation damage in materials. However, significant discrepancies exist in estimations of vacancies between full-cascade (F-C) and quick calculation (Q-C) options in the popular computer code SRIM. This study inspected the SRIM code and a relatively new code called Iradina, which uses a similar methodology, to develop an understanding of the origin of vacancy overestimation in the F-C options for SRIM and Iradina. Here, we found that the default values of thresholds (namely final energy in SRIM and replacement energy in Iradina) in displacement production calculations results in excessively large number of calculated vacancies and very few replacements. After conducting multiple calculations using SRIM, Iradina, and MARLOWE (all based on the binary collision approximation), a comparison of the results indicates that there is a shortcoming in the SRIM and Iradina F-C methodology for treating near-threshold collisions. This issue is responsible for the deficiency of replacements and excess of calculated vacancies in the SRIM and Iradina F-C results. Drawing on the principles of collision physics, we propose recommendations for modifying the source codes to address these issues.

36 MATERIALS SCIENCE↗

Enhanced biomechanical performance of additively manufactured Ti-6Al-4V bone plates

As the global trauma fixation devices market expands rapidly, it is imperative to improve the production of fixation devices through enhanced design accuracy and fit for best performance and maximum patient comfort. Selective laser melting (SLM) is one of the mature additive manufacturing methods, which provides a viable route for the rapid production of such devices. In this work, the ability of SLM to produce near-net-shape parts, as desired for medical implants, was utilized for the fabrication of bone plates from Ti-6Al-4V alloy powder. Martensitic microstructure obtained after the printing of alloy resulted in poor ductility, limiting its application in the field of orthopedics. A specially designed repeated cyclic heating and cooling close to but below the β-transus was used to transform from acicular to a bimodal microstructure without the need for plastic deformation prior to heat treatment for improving the ductility. Bone plates subjected to this heat treatment were mechanically tested by means of tensile and 3-point bend tests and demonstrated large improvement in ductility, and the values were comparable to those similar plates prepared from wrought alloy. Other important properties required for implants were assessed, such as corrosion resistance in simulated body fluid and cytocompatibility in vitro using MC3T3-E1 cells. These results for the bone plate after heat treatment were excellent and similar to those of the additively manufactured and wrought plates. Taken together, the performance of the additively manufactured bone plates after subjecting to heat treatment was similar to those of bone plate manufactured using wrought alloy. These results have important implications for the fabrication of patient-specific metallic orthopedic devices using SLM without compromising their biomechanical performance by subjecting them to a tailored heat treatment.

36 MATERIALS SCIENCE↗

Helium causing disappearance of a/2<111> dislocation loops in binary Fe-Cr ferritic alloys

In this work, single and dual-beam self-ion irradiations were performed at 500°C on ultra-high purity Fe14%Cr alloy to ~0.33 displacements-per-atom (dpa), and 0 or 3030 atomic-parts-per-million (appm) helium/dpa, respectively. Using transmission electron microscopy, we reveal that helium can drastically modify the dislocation loop Burgers vector in Fe-Cr alloys. Helium co-implantation caused complete disappearance of a/2<111> type dislocation loops, and the microstructure consisted of only a<100> loops. Conversely, a/2<111> type loops were predominant without He co-implantation. The total loop density remained largely unaffected. The results strikingly contrast literature asserting that helium stabilizes a/2<111> type loops in bcc Fe alloys, based on low temperature irradiations. Collectively analyzing the results with literature suggest that the small positive interaction between helium and self-interstitial atoms (SIA) in Fe predicted by atomistic simulations maybe insufficient to holistically explain the dislocation loop microstructure development in presence of helium. Helium-SIA positive binding inadvertently implies elevated a/2<111> loop fraction and higher loop densities that the present results contradict. Helium induced high cavity density causing a preferential loss of highly glissile <111> clusters, leaving the matrix saturated with <100> type clusters is proposed as a potential mechanism. Further, the in-situ irradiations combined with Burgers vector analysis strengthened the evidence of Cr-induced dislocation loop mobility reduction that appears to stabilize the a/2<111> type loops and causes higher loop densities in Fe-Cr alloys.

36 MATERIALS SCIENCE↗

The role of Cr concentration and temperature on cavity swelling with co-injected helium in dual-ion irradiated Fe and Fe-Cr alloys

The level of chromium plays an essential role in irradiation tolerance of Fe-Cr ferritic alloys. However, conflicting results have been reported regarding the dependence of cavity swelling under irradiation on Cr level and temperature. Here, we have performed a comprehensive set of simultaneous dual-ion (Ni + He) irradiations to high dose (~30 displacements per atom, dpa) at 400–550 °C on a series of ultra-high purity Fe and Fe-Cr binary alloys (3–14 wt.%Cr). Helium co-implantation rates of 0.1 and 10 appm He/dpa were selected to examine He synergistic effects relevant for fission and fusion reactor conditions, respectively. Cavities were observed in all irradiated samples by transmission electron microscopy. The results show that higher He implantation rate causes a shift in the swelling peak to higher temperatures in both Fe and Fe-Cr alloys. When assuming smaller cavities as biased sinks, the non-monotonic nature of the cavity swelling behavior is related to the ratio of biased to unbiased point defect sink strengths. Cr-enriched precipitates were observed in Fe-14Cr irradiated at 400 °C by atom probe tomography. Our analysis suggests the formation of Cr-enriched precipitates could suppress cavity swelling for Fe-Cr alloys with Cr content above 10 wt%.

36 MATERIALS SCIENCE↗

Interplay of strain and phase evolution of laser powder bed fusion Ti–6Al–4V

While additive manufacturing (AM) provides a method of producing geometrically complex and highly detailed structures, the generation of residual strain in AM processes like laser powder bed fusion (L-PBF) can negatively impact performance-enabling properties. In applications such as orthopedic implants, specific performance windows require optimized microstructures in order to obtain desirable properties from multi-phase alloys like Ti–6Al–4V. This research aims to quantify the microscale origins of strain in L-PBF manufactured Ti–6Al–4V by understanding how strain is distributed at the grain and sub-grain scale, the interplay between phase evolution and strain, and examining post-processing strain relief strategies to control these features. Model spinal cage implants were manufactured from Ti–6Al–4V powder via L-PBF and then subjected to strain relieving heat treatment cycles above and below the Ti–6Al–4V β transus as a function of time and cooling rate. Residual strain was then studied via high resolution electron backscatter diffraction (HR-EBSD), and 2D strain maps with sub-micron resolution were generated for each post-processing state. It was found that macroscale thermal strains decreased with heat treatment time, but additional contributions from phase stabilizing residual strains retained primarily in the α' grains as lattice distortive strain remained. Additionally, the retention of β phase significantly changed the strain and dislocation distribution while reducing overall residual strain. In conclusion, these results were validated and reinforced with 3D mesoscopic micromechanical modeling of strain behavior across simulated microstructures, confirming that the local lattice dilation of α’ martensite is a primary contributor of microscale strain generation and retention in L-PBF Ti–6Al–4V.

36 MATERIALS SCIENCE↗

Processes controlling helium bubble dynamics at varying temperatures in simulated radioactive materials

Alpha-radiation damage is known to degrade materials exposed to harsh radiation environments via swelling and embrittlement by nano-scale helium bubbles. How these bubbles grow under varying temperature is essential to understanding and predicting material failure and optimization. Using in situ X-ray scattering, we probed ≈1012 bubbles before, during and after annealing at different temperatures in He-implanted aluminum to reveal a critical growth activation temperature that depends strongly on the helium implantation conditions. An analysis of the data aided by our molecular dynamics simulations identifies multiple temperature-dependent bubble growth mechanisms above and below the critical growth activation temperature. Moreover, the irreversible bubble growth that occurs after annealing for ≈4 h was evaluated using dislocation dynamics and found to negligibly affect the yield strength but may affect subsequent bubble growth at temperature. These in situ results provide valuable insight into bubble growth never observed before and reveal, for the first time, bubble shrinkage after cooling.

36 MATERIALS SCIENCE↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of high energy deuteron ion beam irradiation on the tensile behavior of HT-9

Ion beam implantations are widely performed to understand the effects of irradiation-induced displacement damage on nuclear structural materials. However, the volume of material that can be investigated is often limited by the maximum energies of accelerator facilitates, leading to a limitation in the thickness of samples whose mechanical properties can be evaluated. The Lawrence Berkeley National Laboratory’s 88-Inch Cyclotron offers a wide range of ions and energies, allowing for material ion implantations at larger scales than typical. Four HT-9 SS-J-geometry tensile specimens were polished and then irradiated with deuterons at the 88-Inch Cyclotron to doses of approximately 0.2 dpa prior to small scale tensile testing. Here, the results from this study show irradiation hardening characterized by the tensile test results and black dot irradiation defects. Additionally, a comprehensive look at low temperature irradiations of high-Cr F/M steels is presented and our results show agreement with the available data.

36 MATERIALS SCIENCE↗

Fractalkine enhances endometrial receptivity and activates iron transport towards trophoblast cells in an in vitro co-culture system of HEC-1A and JEG-3 cells

Highlights: • Fractalkine activates SOX-17 and the NRF2-Keap-1 system in HEC-1A endometrium cells. • Fractalkine triggers IL-6 and IL-1β cytokine secretions contributing endometrium receptivity. • Fractalkine regulates iron homeostasis of endometrium. • Fractalkine contributes to the iron availability of the trophoblast cells. Endometrium receptivity and successful implantation require a complex network of regulatory factors whom production is strictly controlled especially at the implantation window. Many regulators like steroid hormones, prostaglandins, cytokines, extracellular matrix proteins and downstream cell signalling pathways are involved in the process of embryo-endometrium interaction. Our work reveals the effect of fractalkine (FKN), a unique chemokine on progesterone receptor, SOX-17 and NRF2 expressions in HEC-1A endometrial cell line. FKN activates fractalkine receptor signalling and the expression of SOX-17 through progesterone receptor in HEC-1A endometrial cells, and as a consequence it increases endometrial receptivity. Fractalkine also activates the NRF2-Keap-1 signal transduction pathway regulating the IL-6 and IL-1β cytokine productions, which increase endometrial receptivity, as well. The NRF2 transcription factor increases the expression of the iron exporter ferroportin in HEC-1A cells activating iron release towards JEG-3 trophoblast cells. The iron measurements show that iron content of endometrial cells decreases while heme concentration increases at FKN treatment. At the same time, the trophoblast cells show increased iron uptake and total iron content. Based on our results it seems that FKN enhances the establishment of endometrial receptivity and meanwhile it regulates the iron homeostasis of endometrium contributing to the iron availability of the trophoblast cells and the embryo.

60 APPLIED LIFE SCIENCES↗

Unraveling the Early-Stage Ordering of Krypton Solid Bubbles in Molybdenum: A Multimodal Study

Self-organization of defects such as fission gas bubbles in materials can lead to high inventory capacity for fission gas storage and help mitigate swelling caused by fission gases in nuclear fuel materials under radiation in nuclear reactors. Here, we report the physical mechanism of self-organization of krypton (Kr) gas bubbles in molybdenum (Mo) under ion implantation. The ion fluence and temperature-dependent formation of Kr solid bubble superlattice (SBS) in Mo were investigated by using both synchrotron-based small-angle X-ray scattering (SAXS) and transmission electron microscopy (TEM). Early stage self-organization of gas bubbles is observed at a fluence of 2.5 × 10 16 ions/cm 2 at temperatures of 300–400 °C. The bubble lattice constant increases with increasing implantation temperature from 300 to 400 °C. Both experiments and atomic kinetic Monte Carlo modeling indicate that the Kr solid bubbles are weakly ordered in comparison to previously studied helium (He) gas bubble superlattice (GBS) while the lattice constant are relatively smaller for Kr SBS compared to that of He GBS. The irradiation conditions suggest that spinodal decomposition, which is a form of phase separation, probably precedes gas bubble ordering in Mo. Altogether, our work sheds light on the formation mechanism of noble gas superlattice toward the development of radiation-tolerant materials which are important for the design of advanced nuclear reactors.

36 MATERIALS SCIENCE↗

Plasmonic Diamond Membranes for Ultrafast Silicon Vacancy Emission

Silicon vacancy centers (SiVs) in diamond have emerged as a promising platform for quantum sciences due to their excellent photostability, minimal spectral diffusion, and substantial zero-phonon line emission. However, enhancing their slow nanosecond excited-state lifetime by coupling to optical cavities remains an outstanding challenge, as current demonstrations are limited to ~10-fold. Here, we couple negatively charged SiVs to sub-diffraction-limited plasmonic cavities and achieve an instrument-limited ≤8 ps lifetime, corresponding to a 135-fold spontaneous emission rate enhancement and a 19-fold photoluminescence enhancement. Nanoparticles are printed on ultrathin diamond membranes on gold films which create arrays of plasmonic nanogap cavities with ultrasmall volumes. SiVs implanted at 5 and 10 nm depths are examined to elucidate surface effects on their lifetime and brightness. The interplay between cavity, implantation depth, and ultrathin diamond membranes provides insights into generating ultrafast, bright SiV emission for next-generation diamond devices.

Purcell enhancement↗

Bioresorbable Primary Battery Anodes Built on Core–Double-Shell Zinc Microparticle Networks

Bioresorbable implantable electronics require power sources that are also bioresorbable with controllable electrical output and lifetime. In this paper, we report a bioresorbable zinc primary battery anode filament based on a zinc microparticle (MP) network coated with chitosan and Al 2 O 3 double shells. When discharged in 0.9% NaCl saline, a Zn MP filament with a 0.17 × 2 mm 2 cross-sectional area exhibited a stable voltage output of 0.55 V at a current of 0.01 mA. Covered by chitosan and Al 2 O 3 double shells, the zinc MP filament exhibited a directional dissolution behavior with a tunable lifetime approximately linear to its length. A stable 200 h discharging time was achieved with a 15 mm Zn MP filament. The maximum output power was found to be 12 μW at 0.03 mA for one filament. The linearity relationship between the current output and the filament cross-sectional area suggested a facile strategy to raise the power output at constant discharging voltage. The filaments could also be connected in series and in parallel to boost its overall voltage and current output, demonstrating their excellent integration capability. Furthermore, this work presents a promising pathway toward bioresorbable transient batteries with controllable lifetime and power output, demonstrating a great potential for powering transient implantable biomedical devices.

25 ENERGY STORAGE↗

Subcutaneous power supply by NIR-II light

Implantable medical devices are wished to be recharged via contactless power transfer technologies without interventional operations. Superior to subcutaneous power supply by visible light or electromagnetic wave, second near-infrared (NIR-II) light is predicted to possess 60 times subcutaneous power transmission but hard to be utilized. Here we report a photo-thermal-electric converter via the combination of photothermal conversion and thermoelectric conversion. It is able to generate an output power as high as 195 mW under the coverage of excised tissues, presenting advantages of non-invasion, high output power, negligible biological damage, and deep tissue penetration. As an in vivo demonstration, the output power of a packaged converter in the abdominal cavity of a rabbit reaches 20 mW under NIR-II light irradiation through the rabbit skin with a thickness of 8.5 mm. This value is high enough to recharge an implanted high-power-consumption wireless camera and transfer video signal out of body in real-time.

60 APPLIED LIFE SCIENCES↗

Immune-compatible designs of semiconducting polymers for bioelectronics with suppressed foreign-body response

One of the greatest obstacles to achieving implantable electronics with long-term functionality and minimized inflammatory reactions is the immune-mediated foreign-body response (FBR). Recently, semiconducting polymers with mixed electron–ion conductivity have been demonstrated as promising candidates to achieve direct electrical interfacing on bio-tissues. However, there is limited understanding of their immune compatibility in vivo, and strategies for minimizing the FBR through molecular design remain underexplored. Here we introduce a set of molecular design strategies for enhancing the immune compatibility of semiconducting polymers. Specifically, we show that selenophene, when incorporated in the backbone, can mitigate the FBR by suppressing macrophage activation. In addition, side-chain functionalization with immunomodulatory groups decreases the FBR further by downregulating the expression of inflammatory biomarkers. Together, our synthesized polymers achieve suppression of the FBR by as much as 68% (as indicated by the collagen density). In the meantime, these immune-compatible designs still provide a high charge-carrier mobility of around 1 cm 2 V −1 s −1 . In conclusion, we anticipate that such immune-compatible design principles can be translated to a variety of conjugated polymers to suppress the FBR for implantable applications.

Li, Nan [University of Chicago, IL (United States)↗

Indistinguishable telecom band photons from a single Er ion in the solid state

Atomic defects in the solid state are a key component of quantum repeater networks for long-distance quantum communication1. Recently, there has been significant interest in rare earth ions, in particular Er 3+ for its telecom band optical transition that allows long-distance transmission in optical fibres. However, the development of repeater nodes based on rare earth ions has been hampered by optical spectral diffusion, precluding indistinguishable single-photon generation. Here, we implant Er 3+ into CaWO 4 , a material that combines a non-polar site symmetry, low decoherence from nuclear spins and is free of background rare earth ions, to realize significantly reduced optical spectral diffusion. For shallow implanted ions coupled to nanophotonic cavities with large Purcell factor, we observe single-scan optical linewidths of 150 kHz and long-term spectral diffusion of 63 kHz, both close to the Purcell-enhanced radiative linewidth of 21 kHz. This enables the observation of Hong–Ou–Mandel interference between successively emitted photons with a visibility of V = 80(4)%, measured after a 36 km delay line. We also observe spin relaxation times T 1,s = 3.7 s and T 2,s > 200 μs, with the latter limited by paramagnetic impurities in the crystal instead of nuclear spins. Furthermore, this represents a notable step towards the construction of telecom band quantum repeater networks with single Er 3+ ions.

42 ENGINEERING↗