Hierarchically microporous membranes for highly energy-efficient gas separations
Hourglass-shaped or bimodally distributed microcavities enable both high gas permeabilities and selectivities for highly energy-efficient gas separations.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Hourglass-shaped or bimodally distributed microcavities enable both high gas permeabilities and selectivities for highly energy-efficient gas separations.
It is well known that application specific computing systems, optimally designed and configured for a given workload, offer much higher energy-efficiency and throughput than general purpose systems. In modern computing systems, heterogeneous computing systems have emerged that exploit the energy and performance benefits of combining various different domain-specific processor architectures. Application domains such as high-performance computing and machine learning now process terabyte-sized data sets, requiring enormous processing and memory resources. These applications have very high-power consumption due to bottlenecks in the electrical interconnection between processing units. This project aims to reduce both communication energy and latency by integrating universally available accelerators with silicon photonics. It also aims to increase system throughput by exploiting emerging technologies in silicon photonic reconfigurable interconnects; this will allow the system to balance itself in real time to accommodate changes in workloads and data flows.
Abstract One of the grand challenges underlying current direct air capture (DAC) technologies relates to the intensive energy cost for sorbent regeneration and CO 2 release, making the massive scale (GtCO 2 /year) deployment required to have a positive impact on climate change economically unfeasible. This challenge underscores the critical need to develop new DAC processes with substantially reduced regeneration energies. Here, we report a photochemically‐driven approach for CO 2 release by exploiting the unique properties of an indazole metastable‐state photoacid (mPAH). Our measurements on simulated and amino acid‐based DAC systems revealed the potential of mPAH to be used for CO 2 release cycles by regulating pH changes and associated isomers driven by light. Upon irradiating with moderate intensity light, a ≈55 % and ≈68 % to ≈78 % conversion of total inorganic carbon to CO 2 was found for the simulated and amino acid‐based DAC systems, respectively. Our results confirm the feasibility of on‐demand CO 2 release under ambient conditions using light instead of heat, thereby providing an energy efficient pathway for the regeneration of DAC sorbents.
Our report presents an optimization algorithm for energy-efficient driving of electric vehicles. The algorithm is based on Pontryagin’s Minimum Principle by considering the driving mission as an optimal control problem. On a planned route, diverse application cases may occur due to various physical traits such as powertrain (e.g., switching between motor and generator operation), environmental variations (e.g., terrain grade change), traffic laws (e.g., speed limits), and safety concerns (e.g., headway to the leading vehicle). The proposed algorithm handles these real-world challenges by considering the perturbation to the system dynamics and the constraints to the control and state variables.
Electrochemical pH-swing strategies offer a promising avenue for cost-effective and energy-efficient carbon dioxide (CO 2 ) capture, surpassing the traditional thermally activated processes and humidity-sensitive techniques. The concept of elevating seawater’s alkalinity for scalable CO 2 capture without introducing additional chemical as reactant is particularly intriguing due to its minimal environmental impact. However, current commercial plants like chlor-alkali process or water electrolysis demand high thermodynamic voltages of 2.2 V and 1.23 V, respectively, for the production of sodium hydroxide (NaOH) from seawater. These high voltages are attributed to the asymmetric electrochemical reactions, where two completely different reactions take place at the anode and cathode. Here, we developed a symmetric electrochemical system for seawater alkalization based on a highly reversible and identical reaction taking place at the anode and cathode. We utilize hydrogen evolution reaction at the cathode, where the generated hydrogen is looped to the anode for hydrogen oxidation reaction. Theoretical calculations indicate an impressively low energy requirement ranging from 0.07 to 0.53 kWh/kg NaOH for established pH differences of 1.7 to 13.4. Experimentally, we achieved the alkalization with an energy consumption of 0.63 kWh/kg NaOH, which is only 38% of the theoretical energy requirements of the chlor-alkali process (1.64 kWh/kg NaOH). Further tests demonstrated the system’s potential of enduring high current densities (~20 mA/cm 2 ) and operating stability over an extended period (>110 h), showing its potential for future applications. Notably, the CO 2 adsorption tests performed with alkalized seawater exhibited remarkably improved CO 2 capture dictated by the production of hydroxide compared to the pristine seawater.
The primary purpose of this brief, and the full assessment from which its content is derived, is to assist USAID staff in identifying opportunities for designing new interventions that integrate climate finance into their existing/planned energy sector programming. USAID staff are encouraged to review the various examples presented to determine if any aspect of the proposed approaches are applicable to the countries/regions in which they operate.
Energy storage and electrification of buildings hold great potential for future decarbonization. However, there are several technical and economic barriers that prevent large-scale adoption and integration of energy storage in buildings. These barriers include integration with building control systems, high capital costs, and the necessity to identify and quantify value streams for different stakeholders. To overcome these obstacles, it is crucial to develop advanced sizing and dispatch methods to assist planning and operational decision-making for integrating energy storage in buildings. This work develops simple and flexible optimal sizing and dispatch framework for thermal energy storage (TES) and battery energy storage (BES) systems in large-scale office building. The optimal sizes of TES, BES, as well as other building assets are determined in a joint manner instead of sequentially to avoid sub-optimal solutions. The interaction between the sizing at the planning stage and hourly or sub-hourly dispatch at the operating stage is explicitly modeled. The solution is determined considering both capital costs in optimal sizing and operational benefits in optimal dispatch. Comprehensive assessments are performed using simulation studies to quantify potential energy, economic, and emission benefits by different utility tariffs and climate locations, to improve our understanding of the techno-economic performance of different TES and BES systems, and to identify barriers for adopting energy storage for buildings. Finally, the proposed framework will provide guidance to a broad range of stakeholders to properly design energy storage in buildings and maximizes potential benefits, thereby advancing affordable building energy storage deployment and helping us accelerating the transition towards a cleaner and more equitable energy economy.
What happens when advanced lighting and control systems are installed in the real world? Are the advantages and energy savings realized? By observing the design, installation, commissioning, and ongoing use of connected lighting systems in real-world settings, it is possible to identify the strengths, challenges, and points of human-technology interaction that may be new or unfamiliar to those responsible for implementing or maintaining the lighting system. Ultimately, understanding and experiencing each stakeholder’s interaction with the technology can allow the research team to synthesize feedback for manufacturers, improve industry understanding of the technology, and increase adoption. The Northwest Energy Efficiency Alliance (NEEA) office in Portland, OR, is a single-floor installation that puts tunable-white, interoperability, and luminaire-level advanced control capabilities to the test. Compared to simpler, “out-of-the-box” systems that minimize field-adjustable settings, the system utilized in this space allowed for granular field adjustments which required the system specifier, client, and programming agent to make additional decisions regarding system operation while the system was being programmed. This report communicates the observational findings from the installation, programming, and ongoing operation of an advanced office LLLC system.
Cities and communities continue to expand pedestrian and bicycle infrastructure as part of their sustainable mobility and post-pandemic recovery plans. However, the emergence of micro-mobility (e.g., electric bicycles) has created new challenges for urban transport planning. As the popularity of micro-mobility modes has grown, so have safety concerns due to rising injuries, thus challenging many cities to come up with regulatory measures that enable efficient access while minimizing negative impacts from micro-mobility. Leveraging the Open-Source Tool (Mobility Energy Productivity metric), powered by an open-source dataset (OpenStreetMap), and enhanced through the incorporation of perceived discomfort (level-of-traffic stress), this research study focuses on evaluating the accessibility implications of infrastructure planning and regulatory measures for micro-mobility. Five scenarios pertaining to level of traffic stress, sidewalk access, traffic calming, and bike lane coverage were tested in the Denver-Aurora region in Colorado. Maximum improvements in energy-efficient access are realized when allowing sidewalks for micro-mobility use. Cities and planning agencies could leverage this information to assess sidewalk use policies for micro-mobility, while ensuring pedestrian safety and ADA access. Results indicate that expansion of bicycle lane coverage yields 11% accessibility benefits for micro-mobility compared to implementing traffic calming measures yielding 3% accessibility improvements. Further, it was observed most of the population in the Denver-Aurora region is experiencing lower accessibility in-part due to presence of a high-stress connections in the network. Although not generalizable, the use of open-source data and access calculation methodology, make this analysis reproducible and transferable to other locations.
We present our work on developing and training scalable, trustworthy, and energy-efficient predictive graph foundation models (GFMs) using HydraGNN, a multi-headed graph convolutional neural network architecture. HydraGNN expands the boundaries of graph neural network (GNN) computations in both training scale and data diversity. It abstracts over message passing algorithms, allowing both reproduction of and comparison across algorithmic innovations that define nearest-neighbor convolution in GNNs. This work discusses a series of optimizations that have allowed scaling up the GFMs training to tens of thousands of GPUs on datasets consisting of hundreds of millions of graphs. Our GFMs use multitask learning (MTL) to simultaneously learn graph-level and node-level properties of atomistic structures, such as energy and atomic forces. Using over 154 million atomistic structures for training, we illustrate the performance of our approach along with the lessons learned on two state-of-the-art US Department of Energy (US-DOE) supercomputers, namely the Perlmutter petascale system at the National Energy Research Scientific Computing Center and the Frontier exascale system at Oak Ridge Leadership Computing Facility. The HydraGNN architecture enables the GFM to achieve near-linear strong scaling performance using more than 2000 GPUs on Perlmutter and 16,000 GPUs on Frontier.
The global room air conditioner (AC) market is rapidly transitioning toward variable-speed units, offering significant opportunities for energy-efficient designs and the adoption of low-global warming potential (GWP) refrigerants. Emerging economies, particularly in regions such as Malaysia, are expected to drive consumer demand for ACs. This report reviews key trends in the Malaysian AC market, including the availability of high-efficient ACs. Currently, variable-speed units account for 30–65% of the market, achieving cooling seasonal performance factor (CSPF) levels of between 5.0 and 6.0. Cost comparisons show that CSPF 5–6-rated, inverter-driven room ACs are competitively priced against lower-efficiency, fixed-speed units.
Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.
This report outlines the technical assistance provided to Floyd County Fiscal Court, Kentucky, and Vision Granted through the U.S. Department of Energy Clean Energy to Communities Expert Match Program. Floyd County, designated as “distressed” and “disadvantaged,” faces significant economic challenges, including limited job prospects, high energy costs, and youth “brain drain.” This technical assistance aims to address these pressing issues by implementing strategies to enhance home energy efficiency and livability while also aligning retrofit efforts with goals for resilience and workforce development. Through targeted guidance, this report aims to empower Floyd County residents and organizations in navigating resources for improving housing conditions, creating workforce opportunities, and enhancing resilience.
This study reports the process scale-up and long-term performance of an energy-efficient and cost-effective membrane solvent extraction (MSX) process for separation and recovery of high purity rare earth oxides (REOs) from scrap permanent magnets (SPMs). Here, the rare earth elements (REEs), including dysprosium, neodymium, and praseodymium, are recovered from SPMs using a neutral extractant, tetraoctyl diglycolamide (TODGA) embedded in a microporous polypropylene hollow fiber membrane module. The MSX process performance is demonstrated with bench scale module with membrane surface area of 1.4 m 2 to industrial scale modules with membrane surface area of up to 20 m2 to enable the processing of up to 1 ton month –1 of SPMs. The purity and the yield of the recovered REOs are >99.5 wt% and >95%, respectively. The average extraction rate of REOs is >10 g m –2 hr –1 . A skid of MSX system is assembled with a membrane area of 40 m 2 . The MSX skid successfully recovers REOs with a capacity of 300 kg REOs/month. Finally, it is determined that the organic phase containing the extractant maintains its performance up to 250 h. The results suggest that the MSX process is an economically viable and environmentally friendly process for separation and recovery of REOs from electronic wastes.
Buildings consume 75% of U.S. electricity; therefore, improving the efficiency and flexibility of building operations could increase the reliability and resilience of the rapidly-changing electricity system. We estimate the technical potential near- and long-term impacts of best available building efficiency and flexibility measures on annual electricity use and hourly demand across the contiguous U.S. Co-deployment of building efficiency and flexibility avoids up to 742 TWh of annual electricity use and 181 GW of daily net peak load in 2030, rising to 800 TWh and 208 GW by 2050; at least 59 GW and 69 GW of the peak reductions are dispatchable. Implementing efficiency measures alongside flexibility measures reduces the potential for off-peak load increases, underscoring limitations on load shifting in efficient buildings. Overall, however, we find a substantial building-grid resource that could reduce future fossil-fired generation needs while also reducing dependence on energy storage with increasing variable renewable energy penetration.
Washington State's Commercial Energy Code adopted a new energy metric called HVAC Total System Performance Ratio (TSPR) in 2019, a first in the codes world to regulate HVAC system efficiency. TSPR is a ratio of annual heating and cooling loads to the annual carbon emissions associated with the energy consumed by the HVAC system. TSPR provides a performance-based solution to evaluate and improve the overall HVAC design. The TSPR metric and its companion calculation tool were developed by Pacific Northwest National Laboratory (PNNL) with support from U.S. Department of Energy (DOE), Northwest Energy Efficiency Alliance (NEEA) and the City of Seattle. The new metric represents a significant shift in how HVAC design will meet code requirements. Utility programs can also leverage TSPR as a measure to determine energy savings and incentive amounts for HVAC retrofits. This paper describes the efforts by NEEA and its collaborators to prepare the market for TSPR adoption in code. This paper provides the pilot projects led by University of Washington Integrated Design Lab (IDL) to understand potential issues that could be faced by early adopters. This paper also covers how training and outreach provide engagement opportunities that can streamline code compliance, help address issues faced by early adopters and promote participation in utility programs. As Washington State works on the goals of 70% energy reduction and zero fossil-fuel greenhouse gas emission homes and buildings by the year 2031 , system level performance metrics will likely become increasingly more necessary and prevalent. This paper concludes that the HVAC TSPR requirement helps familiarize the HVAC industry with this approach and helps Washington achieve its long-term goals.
Electricity consumption in South Africa comes with a hefty environmental cost to the society. For every kilowatt-hour (kWh) produced, 1 kilogram (kg) of carbon dioxide (CO 2 ) is emitted, 1.4 liters of water are used, and 0.37 grams of particulate emissions are released in the atmosphere. These environmental implications result from the large share of electricity produced from coal (91 percent in 2015). While planned new capacity will ramp up renewable energy, the integrated resource plan for the country still projects the share of col to be 64 percent in 2030. Energy savings provide environmental benefits as well as economic benefits. Energy efficiency standards and labeling (S&L) programs are a policy measure proven to save energy. Such programs have been implemented in many countries to remove inefficient technologies and transform markets to more efficient technologies. In this study, we describe the methodology, assumptions and results of a stock turnover modeling tool that estimates the energy savings achievable by South Africa’s S&L program in the residential sector. We show that if regulations are passed in 2020 and effective in 2021 for 10 major end-use adopting international standards best practices, 6 terawatt-hours (TWh) will be saved in 2030 and 9.5 TWh will be saved in 2040, representing a CO 2 mitigation of 3.7 megatonnes (Mt) in 2030 and 5.8 Mt in 2040, which will contribute to the South African government’s international engagement in fighting against climate change through its National Determined Contribution (NDC). Additional environmental benefits include saving of 6.5 billion liters of water in 2030, representing approximately 100 liters per capita in 2030. Air quality will also improve, as 4 kilotons (kt) of particulate emissions will be avoided, as well as 4.3 Mt of sulfur oxides (SOx) and 23 kt of nitrogen oxides (NOx) in 2030.
Neuromorphic computing approaches become increasingly important as we address future needs for efficiently processing massive amounts of data. The unique attributes of quantum materials can help address these needs by enabling new energy-efficient device concepts that implement neuromorphic ideas at the hardware level. In particular, strong correlations give rise to highly non-linear responses, such as conductive phase transitions that can be harnessed for short- and long-term plasticity. Similarly, magnetization dynamics are strongly non-linear and can be utilized for data classification. This Perspective discusses select examples of these approaches and provides an outlook on the current opportunities and challenges for assembling quantum-material-based devices for neuromorphic functionalities into larger emergent complex network systems.