Search NASA⌕ Search

SEARCH · Search NASA

Results for “Illumination condition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

X-ray illuminated stellar winds - Ionization effects in the radiative driving of stellar winds in massive X-ray binary systems

This paper presents calculations of the effect of changing X-ray ionization conditions on the radiative force experienced by the stellar wind material in a massive X-ray binary system. The radiative line force from the radiation field of the primary is parameterized in terms of the Castor et al. (1975) force multiplier. The results show that the line force decreases sharply, but in a nonlinear way, with increasing X-ray ionization. The dynamic consequences of this effect are discussed.

Stevens, Ian R.↗

Relationships of soil, grass, and bedrock over the Kaweah serpentine melange through spectral mixture analysis of AVIRIS data

A linear mixing model is used to model the spectral variability of an AVIRIS scene from the western foothills of the Sierra Nevada and calibrate these radiance data to reflectance. Five spectral endmembers from the AVIRIS data, plus an ideal 'shade' endmember were required to model the continuum reflectance of each pixel in the image. Three of the endmembers were interpreted to model the surface constituents green vegetation, dry grass, and illumination. These are the main transient surface constituents that are expected to change with shifts in land use or climatic influences and viewing conditions ('shade' only). The spectral distinction between the other three endmembers is very small, yet the spatial distributions are coherent and interpretable. These distributions cross anthropogenic and vegetation boundaries and are best interpreted as different soil types. Comparison of the fraction images to the bedrock geology maps indicates that substrate composition must be a factor contributing to the spectral properties of these endmembers. Detailed examination of the reflectance spectra of the three soil endmembers reveals that differences in the amount of ferric and ferrous iron and/or organic constituents in the soils is largely responsible for the differences in spectral properties of these endmembers.

Mustard, John F.↗

Two-layer viscous instability in a rotating couette device

A novel experiment to study the interfacial shear instability between two liquids is described. Density-matched immiscible liquids are confined between concentric cylinders such that the interface is parallel to the cylinder walls. Interfacial waves that develop because of viscosity differences between the shearing fluids are studied as a function of rotation rate and depth ratio using optical techniques. Conditions neutral stability and the most unstable wavenumber agree reasonably well with predictions from linear stability analysis of the Navier-Stokes equations. Illumination using laser sheets allows precise measurement of the interface shape. Future experiments will verify the correctness of weakly nonlinear theories that describe energy transfer and saturation of wave growth by nonlinear effects. Measurements of solitary wave shapes, that occur far above neutral stability, will be compared to similar measurements for systems that have gravity as an important force to determine how gravity effects large disturbances. These results will be used to interpret slug and annular flow data that have been obtained in other mu g studies.

Gallagher, Christopher↗

Variation of directional reflectance factors with structural changes of a developing alfalfa canopy

Directional reflectance factors of an alfalfa canopy were determined and related to canopy structure, agronomic variables, and irradiance conditions at four periods during a cutting cycle. Nadir and off-nadir reflectance factors decreased with increasing biomass in Thematic Mapper band 3(0.63-0.69 micrometer) and increased with increasing biomass in band 4(0.76-0.90 micrometer). The sensor view angle had less impact on perceived reflectance as the alfalfa progressed from an erectophile canopy of stems after harvest to a near planophile canopy of leaves at maturity. Studies of directional reflectance are needed for testing and upgrading vegetation canopy models and to aid in the complex interpretation problems presented by aircraft scanners and pointable satellites where illumination and viewing geometries may vary widely. Distinct changes in the patterns of radiance observed by a sensor as structural and biomass changes occur are keys to monitoring the growth and condition of crops.

Kirchner, J. A.↗

Side-looking airborne radar image interpretation and geological mapping: Problems and results

Geological experiments and surveys conducted by BRGM and GDTA members to evaluate interest in SLAR image interpretation are summarized. Two surveys were selected for presentation: Les Vans (Massif central, France) and Guyana (South America). They have permitted a comparison between different types of SLAR: Goodyear, Motorola, JPL, and Vigie in term of lithological and structural applications. On the Les Vans test site conclusions reached concern radiometry, which is better on L-band imagery, polarization, HV being more useful than HH for geological mapping in an L-band system, wavelength and illuminations. Over Guyana, the use of Goodyear X-band SLAR enables satisfactory geological and structural mapping under heavy equatorial forest with cloud cover conditions. A differential program was developed for fracture filtering and image enhancement with a coherent light laser, and significant results were obtained.

Scanvic, J. Y.↗

In-Vacuum Photogrammetry of a 10-Meter Solar Sail

In July 2004, a 10-meter solar sail structure developed by L Garde, Inc. was tested in vacuum at the NASA Glenn 30-meter Plum Brook Space Power Facility in Sandusky, Ohio. The three main objections of the test were to demonstrate unattended deployment from a stowed configuration, to measure the deployed shape of the sail at both ambient and cryogenic room temperatures, and to measure the deployed structural dynamic characteristics (vibration modes). This paper summarizes the work conducted to fulfill the second test objective. The deployed shape was measured photogrammetrically in vacuum conditions with four 2-megapixel digital video cameras contained in custom made pressurized canisters. The canisters included high-intensity LED ring lights to illuminate a grid of retroreflective targets distributed on the solar sail. The test results closely matched pre-test photogrammetry numerical simulations and compare well with ABAQUS finite-element model predictions.

Meyer, Chris G.↗

Extension of laboratory-measured soil spectra to field conditions

Spectral responses of two glaciated soils, Chalmers silty clay loam and Fincastle silt loam, formed under prairie grass and forest vegetation, respectively, were measured in the laboratory under controlled moisture equilibria using an Exotech Model 20C spectroradiometer to obtain spectral data in the laboratory under artificial illumination. The same spectroradiometer was used outdoors under solar illumination to obtain spectral response from dry and moistened field plots with and without corn residue cover, representing the two different soils. Results indicate that laboratory-measured spectra of moist soil are directly proportional to the spectral response of that same field-measured moist bare soil over the 0.52 micrometer to 1.75 micrometer wavelength range. The magnitudes of difference in spectral response between identically treated Chalmers and Fincastle soils are greatest in the 0.6 micrometers to 0.8 micrometer transition region between the visible and near infrared, regardless of field condition or laboratory preparation studied.

Stoner, E. R.↗

Test Port for Fiber-Optic-Coupled Laser Altimeter

A test port designed as part of a fiber optic coupled laser altimeter receiver optical system allows for the back-illumination of the optical system for alignment verification, as well as illumination of the detector(s) for testing the receiver electronics and signal-processing algorithms. Measuring the optical alignment of a laser altimeter instrument is difficult after the instrument is fully assembled. The addition of a test port in the receiver aft-optics allows for the back-illumination of the receiver system such that its focal setting and boresight alignment can be easily verified. For a multiple-detector receiver system, the addition of the aft-optics test port offers the added advantage of being able to simultaneously test all the detectors with different signals that simulate the expected operational conditions. On a laser altimeter instrument (see figure), the aft-optics couple the light from the receiver telescope to the receiver detector(s). Incorporating a beam splitter in the aft-optics design allows for the addition of a test port to back-illuminate the receiver telescope and/or detectors. The aft-optics layout resembles a T with the detector on one leg, the receiver telescope input port on the second leg, and the test port on the third leg. The use of a custom beam splitter with 99-percent reflection, 1-percent transmission, and a mirrored roof can send the test port light to the receiver telescope leg as well as the detector leg, without unduly sacrificing the signal from the receiver telescope to the detector. The ability to test the receiver system alignment, as well as multiple detectors with different signals without the need to disassemble the instrument or connect and reconnect components, is a great advantage to the aft-optics test port. Another benefit is that the receiver telescope aperture is fully back-illuminated by the test port so the receiver telescope focal setting vs. pressure and or temperature can be accurately measured (as compared to schemes where the aperture is only partially illuminated). Fiber-optic coupling the test port also allows for the modularity of testing the receiver detectors with a variety of background and signal laser sources without the need of using complex optical set-ups to optimize the efficiency of each source.

Ramos Izquierdo, Luis↗

An Illumination Modeling System for Human Factors Analyses

Seeing is critical to human performance. Lighting is critical for seeing. Therefore, lighting is critical to human performance. This is common sense, and here on earth, it is easily taken for granted. However, on orbit, because the sun will rise or set every 45 minutes on average, humans working in space must cope with extremely dynamic lighting conditions. Contrast conditions of harsh shadowing and glare is also severe. The prediction of lighting conditions for critical operations is essential. Crew training can factor lighting into the lesson plans when necessary. Mission planners can determine whether low-light video cameras are required or whether additional luminaires need to be flown. The optimization of the quantity and quality of light is needed because of the effects on crew safety, on electrical power and on equipment maintainability. To address all of these issues, an illumination modeling system has been developed by the Graphics Research and Analyses Facility (GRAF) and Lighting Environment Test Facility (LETF) in the Space Human Factors Laboratory at NASA Johnson Space Center. The system uses physically based ray tracing software (Radiance) developed at Lawrence Berkeley Laboratories, a human factors oriented geometric modeling system (PLAID) and an extensive database of humans and environments. Material reflectivity properties of major surfaces and critical surfaces are measured using a gonio-reflectometer. Luminaires (lights) are measured for beam spread distribution, color and intensity. Video camera performances are measured for color and light sensitivity. 3D geometric models of humans and the environment are combined with the material and light models to form a system capable of predicting lighting conditions and visibility conditions in space.

Huynh, Thong↗

Order-sorting filter transmittance measured with an array detector

The simultaneous measurement of the spectrally and spatially variant transmittance of a linear variable order-sorting filter in a manner that closely resembles its conditions of actual use is described. The transmittance of a prototype order-sorting filter was measured in the 400- to 880-nm wavelength region by illuminating it with the output beam of a spectrophotometer while the filter was attached to the front of a 30 x 32 pixel silicon array detector. The filter was designed to be used in the output beam of a grating spectrometer to prevent the dispersal of higher diffracted orders onto an array detector. Areas of the filter that were spatially matched to the corresponding detector pixel column had measured peak transmittances of about 90 percent that were uniform to within +/- 1.5 percent along a given column. Transmittances for incident wavelengths shorter than the desired bandpass, corresponding to the order overlap region, were measured in the 0.003 range. Line spread function measurements made with the array detector indicated no significant beam spreading caused by inserting the filter into the beam.

Heaney, James B.↗

Residual conductivity in unannealed amorphous germanium.

An enhanced residual conductivity which persists long after cessation of illumination has been observed in amorphous germanium at 77 K. The effect may be thermally quenched by heating to 120 K, returning the sample to its initial condition.

Burke, T. J.↗

An experimental investigation of the chopping of helicopter main rotor tip vortices by the tail rotor. Part 2: High speed photographic study

The interaction of a free vortex and a rotor was recorded photographically using oil smoke and stroboscopic illumination. The incident vortex is normal to the plane of the rotor and crosses the rotor plane. This idealized aerodynamic experiment most nearly corresponds to helicopter flight conditions in which a tip vortex from the main rotor is incident upon the tail rotor while hovering. The high speed photographs reveal important features not observed using conventional photography where the image is the time average of varying instantaneous images. Most prominent is the strong interaction between the rotor tip vortex system and the incident vortex, resulting in the roll-up of the incident vortex around the (stronger) tip vortices and the resulting rapid destabilization of the deformed incident vortex. The viscous interaction is clearly shown also. Other forms of instabilities or wave-like behavior may be apparent from further analysis of the photographs.

Cary, Charles M.↗

Passive MMW camera for low visibility landings

A passive, millimeter wave imaging sensor for aircraft landing in low or poor visibility conditions is described. The sensor can be incorporated in a camera for future enhanced/synthetic vision systems. Contrast is provided by differences in material reflectivities, temperature, and sky illumination of the scene being imaged. Photographic images of the system's fog penetration capabilities are presented. A combinatorial geometry technique is used to construct the scene geometries. This technique uses eight basic geometric shapes which are used as building blocks for 3-D complex-shaped objects. The building blocks are then combined via union, intersection and exclusion operations to form 3-D scene objects and the combinatorial geometry package determines ray intercepts with scene objects, providing the specific surfaces and propagation distance for the scene.

Shoucri, Merit↗

Determination of washout performance of various monochrome displays under simulated flight ambient and solar lighting conditions

The aircraft cockpit ambient lighting simulation system (ACALSS) has been developed to study display readability and associated pilot/vehicle performance effects in a part-task simulator cockpit. In the study reported here, the ACALSS was used to determine the illumination levels at which subjects lose the ability to maintain aircraft states when using three display technologies as display media for primary flight displays: a standard monochrome EL (electroluminescent) flat-panel, a laboratory-class monochrome CRT, and an enhanced-brightness EL flat-panel. The multivariate statistical technique of modified profile analysis was used to test for performance differences between display devices as functions of illumination levels. The standard monochrome EL flat-panel display began to washout after the 2500 foot-candle level of illumination. The monochrome CRT began to washout after the 5500 foot-candle level of illumination. No performance decrements by increased illumination up to the 12,000 foot-candle level were found for the enhanced-brightness EL flat-panel display. What was not anticipated was that half the subjects would subjectively prefer the CRT over the enhanced-brightness EL, even though their performance errors would have indicated the opposite.

Batson, Vernon M.↗

Head Pose Estimation Using Multilinear Subspace Analysis for Robot Human Awareness

Mobile robots, operating in unconstrained indoor and outdoor environments, would benefit in many ways from perception of the human awareness around them. Knowledge of people's head pose and gaze directions would enable the robot to deduce which people are aware of the its presence, and to predict future motions of the people for better path planning. To make such inferences, requires estimating head pose on facial images that are combination of multiple varying factors, such as identity, appearance, head pose, and illumination. By applying multilinear algebra, the algebra of higher-order tensors, we can separate these factors and estimate head pose regardless of subject's identity or image conditions. Furthermore, we can automatically handle uncertainty in the size of the face and its location. We demonstrate a pipeline of on-the-move detection of pedestrians with a robot stereo vision system, segmentation of the head, and head pose estimation in cluttered urban street scenes.

Ivanov, Tonislav↗

X-Ray Diffraction Measurements of Residual Stress in a Cold Sprayed Ni Coating

X-ray diffraction (XRD) was used to investigate the residual stress in a cold sprayed Ni coating which failed to form a bimetallic joint with NASA HR-1. The objective was to apply pure Ni by cold spray as a diffusion barrier between the Ni-based alloy NASA HR-1 and the Cu-based GRCop-42 for a thrust cell assembly. After additive manufacturing of the GRCop-42 cylinder, the commercially pure Ni coating was cold sprayed onto the cylinder. It was intended to have NASA HR-1 applied directly onto the Ni coating by Directed Energy Deposition (DED), however the bond failed during the first layer of DED. Residual stress measurements were collected via the Sin²ψ method in three equally spaced locations on the top surface of the Ni coating in both as-cold sprayed and heat-treated conditions. The results revealed both compressive and tension stresses on the as-cold sprayed sample and compressive stresses in the heat-treated sample. The results were illuminated when plotted at their respective positions and with their respective orientation angles around a circle. This showed rotational symmetry in the residual stress measurements, which correlated to the processing method used during application of the Ni coating.

Laura Wilson↗

Investigating the Effects of Exposure to Blue-Enriched Light or Peppermint Odor on Alertness, Mood, and Performance Upon Awakening from Deep Sleep at Night

Introduction: Sleep inertia refers the transient neurobehavioral impairments experienced immediately after waking from sleep. This period of reduced alertness and performance poses a significant safety risk to on-call workers who may be required to perform a safety-critical task immediately after waking (e.g., emergency services, health care, and military). In these operations, the need for a rapid return to full alertness is critical to mission safety and success. Several factors may exacerbate sleep inertia, resulting in greater impairment upon waking, including: waking from deep sleep, (i.e., slow wave sleep, SWS), waking at night, and waking following prior sleep loss. Awakenings under these conditions are common for on-call and extended shift workers who may need to perform safety-critical tasks soon after waking from unprotected sleep opportunities. Therefore, there is a need for evidence-based reactive countermeasures (i.e., used upon waking) to the cognitive consequences sleep inertia. Specifically, countermeasures that can rapidly restore alertness and performance immediately following sleep. A recent review of the literature on reactive countermeasures highlighted several research gaps and promising candidates for further investigation. The review also emphasized the need for countermeasures that are operationally viable and readily deployed in occupational settings. This study aims to address the identified gaps and limitations by assessing the efficacy of exposure to two known acute alerting stimuli - blue-enriched light and peppermint odor - to improve cognitive performance, alertness, and mood immediately after waking from SWS at night. Materials and Methods: Twelve participants completed a two-week within-subject, randomized, cross-over intervention study including two in-laboratory overnight visits. During each experimental week, the subjects experienced one intervention (light or peppermint) and a control condition upon awakening from SWS at night. The presentation order of the two conditions (intervention or control) at wake-up and the order of intervention (light or peppermint) by week was randomized by sex. Prior to each in-laboratory visit, participants maintained a sleep schedule of 8.5 h for 5 nights and 5 h for one night. Compliance with this sleep schedule was confirmed by actigraphy. In the laboratory, participants went to bed at their habitual bedtime and were monitored by standard polysomnography. After at least five minutes of continuous SWS, participants were awoken and exposed, in a randomized order, to either the control or intervention condition. During the hour after awakening from SWS (at 2, 17, 32, and 47 minutes after waking), participants completed a battery of tasks including a 5-minute psychomotor vigilance task (PVT), a subjective scale of alertness (Karolinska Sleepiness Scale, KSS), and visual analogue scales (VAS) of mood. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the alternative condition (control or intervention). Following this second awakening, participants were allowed to sleep until their habitual wake time and were then released from the laboratory. Participants then followed the at-home sleep schedule and returned to the laboratory for the second intervention (light or peppermint) following the procedures described above. The light intervention involved exposure to a blue-enriched light canvas illuminated for 1 hour at a distance of ~56 cm from the participant (~200 lux and ~60 melanopic lux at angle of gaze). For the peppermint intervention, peppermint oil was pipetted onto a mask, and participants inhaled the odor with the mask covering the nose and mouth for 1 minute. The control condition for both weeks involved a dim, red ambient light (<1 lux). An odorless mask, without any oil pipetted onto the mask, was also worn in the peppermint control condition. Results: Compared to the control condition, participants exposed to blue-enriched light had fewer PVT lapses (χ2 = 5.285, p = .022), reported feeling more alert (KSS: F1,77 = 4.955, p = .029; VASalert: F1,77 = 8.226, p = .005), and had improved mood (VAScheerful: F1,77 = 8.615, p = .004; VASdepressed: F1,77 = 4.649, p = .034; VASlethargic: F1,77 = 5.652, p = .020). Exposure to peppermint oil did not improve any outcome measures on any of the tasks compared to control condition (p > .05). Conclusions: We found that participants had fewer lapses of attention upon awakening when exposed to blue-enriched light compared to dim, red light. In addition, participants reported feeling more alert, more cheerful, less depressed, and less lethargic in the blue-enriched light condition. Brief exposure to a peppermint odor, however, did not appear to improve performance, alertness, or mood under the experimental conditions. Our null results in the peppermint condition may have been due to methodological limitations such as the duration and method of administration. Given the need to mitigate the potential impact of sleep inertia on safety-critical tasks in on-call operations, our findings suggest that blue-enriched light exposure upon awakening may help to improve performance and alertness during the sleep inertia period following awakening from deep, nocturnal sleep. We are currently exploring the potential mechanisms for the effect of light on cognitive performance upon awakening as well as investigating its application in real-world settings to explore the translational efficacy of this countermeasure to occupational environments. Continued exploration into light and other reactive countermeasures, and potentially their combination, is needed in order to provide evidence-based guidance on effective sleep inertia countermeasures to improve the alertness and performance of those required to perform safety-critical tasks soon after waking.

sleep inertia↗

Radiation damage in silicon NIP solar cells

The performance parameters of n(+) p p(+) silicon solar cells of varying thicknesses with boron doped p base resistivities of 1250 and 84 ohm centimeters were determined. High injection theory was used to analyze the experimental data. Results from an analysis of open circuit voltages show a much greater contribution to V(oc) from the back junction than is the case for the lower resistivity in common use. The base minority carrier distribution is seen to be significant in determining the contribution of V(B), the base contribution to V(oc). Although V(B) is small, its value increases with increasing radiation fluence. In this connection it is noted that, with illumination from the p(+) side, the sign of V(B) becomes positive, and V(B) itself becomes an additive term to V(oc). Diffusion lengths determined under high injection conditions are significantly greater than those obtained under low injection, while damage coefficients under low injection are higher than those obtained under high injection conditions.

Weinberg, I.↗