Search NASA⌕ Search

SEARCH · Search NASA

Results for “InSPIRE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Quantum-inspired method for solving the Vlasov-Poisson equations

Kinetic simulations of collisionless (or weakly collisional) plasmas using the Vlasov equation are often infeasible due to high-resolution requirements and the exponential scaling of computational cost with respect to dimension. Recently, it has been proposed that matrix product state (MPS) methods, a quantum-inspired but classical algorithm, can be used to solve partial differential equations with exponential speed-up, provided that the solution can be compressed and efficiently represented as a MPS within some tolerable error threshold. Here, in this work, we explore the practicality of MPS methods for solving the Vlasov-Poisson equations for systems with one coordinate in space and one coordinate in velocity, and find that important features of linear and nonlinear dynamics, such as damping or growth rates and saturation amplitudes, can be captured while compressing the solution significantly. Furthermore, by comparing the performance of different mappings of the distribution functions onto the MPS, we develop an intuition of the MPS representation and its behavior in the context of solving the Vlasov-Poisson equations, which will be useful for extending these methods to higher-dimensional problems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

GW170817: Observation of Gravitational Waves from a Binary Neutron Star Inspiral

On August 17, 2017 at 1241:04 UTC the Advanced LIGO and Advanced Virgo gravitational-wave detectors made their first observation of a binary neutron star inspiral. The signal, GW170817, was detected with a combined signal-to-noise ratio of 32.4 and a false-alarm-rate estimate of less than one per 8.0 × 10 4 years. We infer the component masses of the binary to be between 0.86 and 2.26 M ⊙ , in agreement with masses of known neutron stars. Restricting the component spins to the range inferred in binary neutron stars, we find the component masses to be in the range 1.17–1.60 M ⊙ , with the total mass of the system 2.74 $^{+0.04}_{–0.01}$ M ⊙ . The source was localized within a sky region of 28 deg 2 (90% probability) and had a luminosity distance of 40$^{+8}_{–14}$ Mpc , the closest and most precisely localized gravitational-wave signal yet. The association with the γ-ray burst GRB 170817A, detected by Fermi-GBM 1.7 s after the coalescence, corroborates the hypothesis of a neutron star merger and provides the first direct evidence of a link between these mergers and short γ-ray bursts. Subsequent identification of transient counterparts across the electromagnetic spectrum in the same location further supports the interpretation of this event as a neutron star merger. This unprecedented joint gravitational and electromagnetic observation provides insight into astrophysics, dense matter, gravitation, and cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Feedback-based quantum algorithm inspired by counterdiabatic driving

In recent quantum algorithmic developments, a feedback-based approach has shown promise for preparing quantum many-body system ground states and solving combinatorial optimization problems. This method utilizes quantum Lyapunov control to iteratively construct quantum circuits. Here, we propose a substantial enhancement by implementing a protocol that uses ideas from quantum Lyapunov control and the counterdiabatic driving protocol, a key concept from quantum adiabaticity. Our approach introduces an additional control field inspired by counterdiabatic driving. We apply our algorithm to prepare ground states in one-dimensional quantum Ising spin chains. Comprehensive simulations demonstrate a remarkable acceleration in population transfer to low-energy states within a significantly reduced time frame compared to conventional feedback-based quantum algorithms. This acceleration translates to a reduced quantum circuit depth, a critical metric for potential quantum computer implementation. We validate our algorithm on the IBM cloud computer, highlighting its efficacy in expediting quantum computations for many-body systems and combinatorial optimization problems.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantifying uncertainty in physics-based predictions of rare-isotope production cross sections via Bayesian-inspired model averaging across nuclear mass tables

Accurate prediction of fragmentation cross sections is essential for rare-isotope beam production, planning new-isotope searches, and designing experiments to study the most exotic regions of the nuclear chart. However, existing reaction models and phenomenological cross-section parametrizations often exhibit significant deviations over broad regions of mass and charge. In this work, a Bayesian-inspired model-averaging framework is developed to combine abrasion-ablation (AA) calculations based on multiple nuclear mass tables into a single statistically weighted estimate. For the calibrated systems, the model weights are assigned empirically according to the relative quality of fit to measured cross sections, thereby reducing systematic model bias while preserving the underlying physics content of the AA description. The weights are constrained using proton-rich fragmentation data for the 78 Kr and 124 Xe projectiles. The resulting parameter trends are then propagated to the 92 Mo and 144 Sm systems through a controlled scaling procedure. In the present implementation, the excitation-energy prescription is fixed, while the averaging is performed across nuclear-mass inputs; the framework provides both weighted cross sections and associated uncertainty estimates. Applied to proton-rich fragmentation, the present approach provides a practical basis for interpolation and limited extrapolation in regions relevant to rare-isotope production. The resulting predictions are used to assess the production of very proton-rich nuclei, and candidate new isotopes are discussed.

Bayesian methods↗

Enhanced Power Grid Maintenance Planning and Quantum-Inspired Combinatorial Prospects

Efficient and reliable scheduling of maintenance for power generation and transmission infrastructure is essential for minimizing operational costs and ensuring grid stability. This paper introduces an integrated optimization framework for coordinated maintenance scheduling of generators and transmission lines under resource and reliability constraints. The model minimizes a composite cost function including maintenance and generation costs, as well as penalties for delayed maintenance, while satisfying N−1 security constraints, operational limits, and crew availability. Case studies on the IEEE 300-bus test system demonstrate the effectiveness of the proposed approach in producing feasible and cost-effective maintenance schedules. To address scalability and combinatorial complexity, the model is mapped into a Quadratic Unconstrained Binary Optimization (QUBO) problem, enabling exploration of solution approaches based on Quantum Imaginary Time Evolution (QITE). While the QUBO reformulation provides a foundation for future quantum-inspired optimization, this study focuses primarily on the development and demonstration of the classical optimization framework and illustrates the potential applicability of QITE in large-scale maintenance scheduling.

Chen, Yang [ORNL] (ORCID:0000000271693874)↗

Tropical forests and global change: biogeochemical responses and opportunities for cross-site comparisons, an organized INSPIRE session at the 108th Annual Meeting, Ecological Society of America, Portland, Oregon, USA, August 2023

In this study, tropical forests play a critical role in the global carbon (C) cycle. These ecosystems maintain the highest rates of net primary production (NPP) on Earth, contain c. 30% of terrestrial C stocks, and have some of the largest stores of fine-root biomass globally, as well as higher fine-root production and turnover rates compared with other biomes. Tropical forest responses to projected warming, altered rainfall regimes, and elevated CO 2 concentrations are likely to be different from other ecosystems because of their unique characteristics (Box 1), making targeted research and model development important for understanding tropical forest–climate feedbacks. There is now a critical mass of long-term global change field experiments and modeling efforts in tropical forests, yet thus far there has been little synthesis, cross-site comparison, or multi-site standardized experimentation among tropical forests to help us understand how these biomes are changing. An organized INSPIRE session at the 108th Annual Meeting of the Ecological Society of America set out to tackle just this. Speakers covered large-scale tropical forest field experiments and modeling efforts, with an emphasis on changes in ecosystem biogeochemistry under warming, drying, elevated atmospheric CO 2 , and changing nutrient status. In this Meeting report, we provide an overview of the large-scale global change experiments presented and highlight the main objectives and opportunities for tropical forest research that emerged, including cross-site comparisons and integration with ecosystem-scale models (Fig. 1).

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-32: Calypso(R) and Laser-Based Localization Systems Comparison for Left-Sided Breast Cancer Patients Using Deep Inspiration Breath Hold

Purpose: Our institution uses a manual laser-based system for primary localization and verification during radiation treatment of left-sided breast cancer patients using deep inspiration breath hold (DIBH). This primary system was compared with sternum-placed Calypso(R) beacons (Varian Medical Systems, CA). Only intact breast patients are considered for this analysis. Methods: During computed tomography (CT) simulation, patients have BB and Calypso(R) surface beacons positioned sternally and marked for free-breathing and DIBH CTs. During dosimetry planning, BB longitudinal displacement between free breathing and DIBH CT determines laser mark (BH mark) location. Calypso(R) beacon locations from the DIBH CT are entered at the Tracking Station. During Linac simulation and treatment, patients inhale until the cross-hair and/or lasers coincide with the BH Mark, which can be seen using our high quality cameras (Pelco, CA). Daily Calypso(R) displacement values (difference from the DIBH-CT-based plan) are recorded.The displacement mean and standard deviation was calculated for each patient (77 patients, 1845 sessions). An aggregate mean and standard deviation was calculated weighted by the number of patient fractions.Some patients were shifted based on MV ports. A second data set was calculated with Calypso(R) values corrected by these shifts. Results: Mean displacement values indicate agreement within 1±3mm, with improvement for shifted data (Table). Conclusion: Both unshifted and shifted data sets show the Calypso(R) system coincides with the laser system within 1±3mm, demonstrating either localization/verification system will Resultin similar clinical outcomes. Displacement value uncertainty unilaterally reduces when shifts are taken into account.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-33: Cardiac Movement in Deep Inspiration Breath-Hold for Left-Breast Cancer Radiotherapy

Purpose: The present study was designed to investigate the displacement of heart using Deep Inspiration Breath Hold (DIBH) CT data compared to free-breathing (FB) CT data and radiation exposure to heart. Methods: Treatment planning was performed on the computed tomography (CT) datasets of 20 patients who had received lumpectomy treatments. Heart, lung and both breasts were outlined. The prescribed dose was 50 Gy divided into 28 fractions. The dose distributions in all the plans were required to fulfill the International Commission on Radiation Units and Measurement specifications that include 100% coverage of the CTV with ≥ 95% of the prescribed dose and that the volume inside the CTV receiving > 107% of the prescribed dose should be minimized. Displacement of heart was measured by calculating the distance between center of heart and left breast. For the evaluation of radiation dose to heart, minimum, maximum and mean dose to heart were calculated. Results: The maximum and minimum left-right (LR) displacements of heart were 8.9 mm and 3 mm, respectively. The heart moved > 4 mm in the LR direction in 17 of the 20 patients. The distances between the heart and left breast ranged from 8.02–17.68 mm (mean, 12.23 mm) and 7.85–12.98 mm (mean, 8.97 mm) with DIBH CT and FB CT, respectively. The maximum doses to the heart were 3115 cGy and 4652 cGy for the DIBH and FB CT dataset, respectively. Conclusion: The present study has demonstrated that the DIBH technique could help to reduce the risk of radiation dose-induced cardiac toxicity by using movement of cardiac; away from radiation field. The DIBH technique could be used in an actual treatment room for a few minutes and could effectively reduce the cardiac dose when used with a sub-device or image acquisition standard to maintain consistent respiratory motion.

60 APPLIED LIFE SCIENCES↗

SU-E-T-426: Dose Delivery Accuracy in Breast Field Junction for Free Breath and Deep Inspiration Breath Hold Techniques

Purpose: The purpose of this work was to verify the accuracy of the dose distribution along the field junction in a half beam irradiation technique for breast cancer patients receiving radiation to the breast or chest wall (CW) and the supraclavicular LN region for both free breathing and deep inspiration breath hold (DIBH) technique. Methods: We performed in vivo measurements for nine breast cancer patients receiving radiation to the breast/CW and to the supraclavicular LN region. Six patients were treated to the left breast/CW using DIBH technique and three patients were treated to the right breast/CW in free breath. We used five microMOSFET dosimeters: three located along the field junction, one located 1 cm above the junction and the fifth microMOSFET located 1 cm below the junction. We performed consecutive measurements over several days for each patient and compared the measurements to the TPS calculation (Eclipse, Varian™). Results: The calculated and measured doses along the junction were 0.97±0.08 Gy and 1.02±0.14 Gy, respectively. Above the junction calculated and measured doses were 0.91±0.08 Gy and 0.98±0.09 Gy respectively, and below the junction calculated and measured doses were 1.70±0.15 Gy and 1.61±0.09 Gy, respectively. All differences were not statistically significant. When comparing calculated and measured doses for DIBH patients only, there was still no statistically significant difference between values for all dosimeter locations. Analysis was done using the Mann-Whitney Rank-Sum Test. Conclusion: We found excellent correlation between calculated doses from the TPS and measured skin doses at the junction of several half beam fields. Even for the DIBH technique, where there is more potential for variance due to depth of breath, there is no over or underdose along the field junction. This correlation validates the TPS, as well an accurate, reproducible patient setup.

60 APPLIED LIFE SCIENCES↗

TH-C-12A-11: Target Correlation of a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique

Purpose: To evaluate the use of 3D optical surface imaging as a new surrogate for respiratory motion gated deep-inspiration breath-hold (DIBH) technique for left breast cancer patients. Methods: Patients with left-sided breast cancer after lumpectomy or mastectomy were selected as candidates for DIBH technique for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH CTs to determine whether DIBH was beneficial in reducing heart doses. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB and DIBH CTs were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Results: Reduction in heart dose can be achieved for left-sided breast patients using DIBH. Results showed that RPM has poor correlation with target position, as determined by the MV Cine imaging. This indicates that RPM may not be an adequate surrogate in defining the breath-hold level when used alone. Alternatively, the AlignRT surface imaging demonstrated a better correlation with the actual CW excursion during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommend threshold of ±3 mm and 5 mm, respectively. Conclusion: 3D optical surface imaging serves as a superior target surrogate for the left breast treatment when compared to RPM. Working together with the realtime MV Cine imaging, they ensure accurate patient setup and dose delivery, while minimizing the imaging dose to patients.

60 APPLIED LIFE SCIENCES↗

SU-C-19A-01: A Simple Deep Inspiration Breath Hold System

Purpose: Deep Inspiration Breath Hold (DIBH) Radiation therapy for left sided breast can reduce dose to the lungs and heart. The purpose of this work is to illustrate how to implement a simple method of DIBH for simulation and treatment using equipment readily available in most radiation oncology clinics. Methods: For simulation and treatment, a foam block is placed on the patient's abdomen or chest and a horizontal laser mounted on a movable slide is aimed at the center of the foam block. After a coaching session the block is marked at the average free breathing position and average DIBH position. The position of block relative to laser can be seen by the patient via prism glasses as well as the radiation therapists via a video camera system. Simulation CT scans and treatment delivery are performed under DIBH conditions. Imaging and treatment are performed by manually turning the beam on once the patient has achieved DIBH after being given verbal instructions. Results: Manually triggered imaging was used daily to verify DIBH reproducibility for all patients treated using this system. Sets of before and during port images were used to ensure patient position was appropriate for treatment. Results of the laser on block method were compared to a sister facility using surface mapping techniques for DIBH and the two methods were found to have clinically equivalent reproducibility. Conclusion: The laser and block system was found to be simple to implement and robust during patient treatment. This system can be created from readily available materials at low cost and provides adequate feedback to patient and therapists. During treatment images document the reproducibility of setup and give confidence to clinicians that this method is reproducible from day to day.

60 APPLIED LIFE SCIENCES↗

Monitoring ABC-assisted deep inspiration breath hold for left-sided breast radiotherapy with an optical tracking system

Purpose: Recent knowledge on the effects of cardiac toxicity warrants greater precision for left-sided breast radiotherapy. Different breath-hold (BH) maneuvers (abdominal vs thoracic breathing) can lead to chest wall positional variations, even though the patient’s tidal volume remains consistent. This study aims to investigate the feasibility of using optical tracking for real-time quality control of active breathing coordinator (ABC)-assisted deep inspiration BH (DIBH). Methods: An in-house optical tracking system (OTS) was used to monitor ABC-assisted DIBH. The stability and localization accuracy of the OTS were assessed with a ball-bearing phantom. Seven patients with left-sided breast cancer were included. A free-breathing (FB) computed tomography (CT) scan and an ABC-assisted BH CT scan were acquired for each patient. The OTS tracked an infrared (IR) marker affixed over the patient’s xiphoid process to measure the positional variation of each individual BH. Using the BH within which the CT scan was performed as the reference, the authors quantified intra- and interfraction BH variations for each patient. To estimate the dosimetric impact of BH variations, the authors studied the positional correlation between the marker and the left breast using the FB CT and BH CT scans. The positional variations of 860 BHs as measured by the OTS were retrospectively incorporated into the original treatment plans to evaluate their dosimetric impact on breast and cardiac organs [heart and left anterior descending (LAD) artery]. Results: The stability and localization accuracy of the OTS was within 0.2 mm along each direction. The mean intrafraction variation among treatment BHs was less than 2.8 mm in all directions. Up to 12.6 mm anteroposterior undershoot, where the patient’s chest wall displacement of a BH is less than that of a reference BH, was observed with averages of 4.4, 3.6, and 0.1 mm in the anteroposterior, craniocaudal, and mediolateral directions, respectively. A high positional correlation between the marker and the breast was found in the anteroposterior and craniocaudal directions with respective Pearson correlation values of 0.95 and 0.93, but no mediolateral correlation was found. Dosimetric impact of BH variations on breast coverage was negligible. However, the mean heart dose, mean LAD dose, and max LAD dose were estimated to increase from 1.4/7.4/18.6 Gy (planned) to 2.1/15.7/31.0 Gy (delivered), respectively. Conclusions: In ABC-assisted DIBH, large positional variation can occur in some patients, due to their different BH maneuvers. The authors’ study has shown that OTS can be a valuable tool for real-time quality control of ABC-assisted DIBH.

60 APPLIED LIFE SCIENCES↗

SU-E-J-62: Breath Hold for Left-Sided Breast Cancer: Visually Monitored Deep Inspiration Breath Hold Amplitude Evaluated Using Real-Time Position Management

Purpose: We used Real-Time Position Management (RPM) to evaluate breath hold amplitude and variability when gating with a visually monitored deep inspiration breath hold technique (VM-DIBH) with retrospective cine image chest wall position verification. Methods: Ten patients with left-sided breast cancer were treated using VM-DIBH. Respiratory motion was passively collected once weekly using RPM with the marker block positioned at the xiphoid process. Cine images on the tangent medial field were acquired on fractions with RPM monitoring for retrospective verification of chest wall position during breath hold. The amplitude and duration of all breath holds on which treatment beams were delivered were extracted from the RPM traces. Breath hold position coverage was evaluated for symmetric RPM gating windows from ± 1 to 5 mm centered on the average breath hold amplitude of the first measured fraction as a baseline. Results: The average (range) breath hold amplitude and duration was 18 mm (3–36 mm) and 19 s (7–34 s). The average (range) of amplitude standard deviation per patient over all breath holds was 2.7 mm (1.2–5.7 mm). With the largest allowable RPM gating window (± 5 mm), 4 of 10 VM-DIBH patients would have had ≥ 10% of their breath hold positions excluded by RPM. Cine verification of the chest wall position during the medial tangent field showed that the chest wall was greater than 5 mm from the baseline in only 1 out of 4 excluded patients. Cine images verify the chest wall/breast position only, whether this variation is acceptable in terms of heart sparing is a subject of future investigation. Conclusion: VM-DIBH allows for greater breath hold amplitude variability than using a 5 mm gating window with RPM, while maintaining chest wall positioning accuracy within 5 mm for the majority of patients.

60 APPLIED LIFE SCIENCES↗

SU-F-T-415: Differences in Lung Sparing in Deep Inspiration Breath-Hold and Free Breathing Breast Plans Calculated in Pinnacle and Monaco

Purpose: Deep inspiration breath-hold (DIBH) is used for left-sided breast radiotherapy to spare the heart and lung. The magnitude of sparing has been shown to be significant. Monte Carlo, furthermore, has the potential to calculate most accurately the dose in the heterogeneous lung medium at the interface with the lung wall. The lung dose was investigated in Monaco to determine the level of sparing relative to that calculated in Pinnacle{sup 3}. Methods: Five patients undergoing DIBH radiotherapy on an Elekta Versa HD linear accelerator in conjunction with the Catalyst C-RAD surface imaging system were planned using Phillips Pinnacle{sup 3}. Free breathing plans were also created to clinically assure a benefit. Both plans were re-calculated in Monaco to determine if there were any significant differences. The mean heart dose, mean left lung, and mean total lung dose were compared in addition to the V20 for left and both lungs. Dose was calculated as dose to medium as well as dose to water with a statistical precision of 0.7%. Results: Mean lung dose was significantly different (p < 0.003) between the two calculations for both DIBH (11.6% higher in Monaco) and free breathing (14.2% higher in Monaco). V20 was also higher in Monaco (p < 0.05) for DIBH (5.7% higher) and free breathing (4.9% higher). The mean heart dose was not significantly different between the dose calculations for either DIBH or free breathing. Results were no more than 0.1% different when calculated as dose to water. Conclusion: The use of Monte Carlo can provide insight on the lung dose for both free breathing and DIBH techniques for whole breast irradiation. While the sparing (dose reductions with DIBH as compared to free breathing) is equivalent for either planning system, the lung doses themselves are higher when calculated with Monaco.

60 APPLIED LIFE SCIENCES↗

TH-CD-207A-02: Implementation of Live EPID-Based Inspiration Level Assessment (LEILA) for Deepinspiration Breath-Hold (DIBH) Monitoring Using MV Fluoroscopy

Purpose: As prior work has shown that current DIBH monitoring approaches using surrogate measures (marker block on chest) do not always correspond with the clinical quantity of interest (lung depth, LD), a software tool and workflow are introduced to use MV fluoroscopy during treatment for real-time / Live EPID-based Inspiration Level Assessment (LEILA). Methods: A prototype software tool calculates and displays the LD during the treatment of left sided breast cancer. Calculations are based on MV cine images which are acquired with the treatment beam thereby not incurring any additional imaging dose. Image capture and processing are implemented using a dedicated frame grabber computer. The calculation engine automatically detects image orientation and includes provisions for large treatment fields that exceed the size of the EPID panel. LD is measured along a line profile in the middle of the field. LEILA’s interface displays the current MV image, a reference image (DRR), the current LD, as well as a trace of LD over treatment time. The display includes patient specific LD tolerances. Tolerances are specified for each field and loaded before the treatment. A visual warning is generated when the tolerance is exceeded. LEILA is initially run in parallel with current DIBH techniques. When later run by itself DIBH setup will be done using skin marks and room laser. Results: Offline tests of LEILA confirmed accurate automatic LD measurement for a variety of patient geometries. Deployment of the EPID during all left sided breast treatments was well tolerated by patients and staff during a multi-month pilot. The frame grabber provides 11 frames-per-second; the MATLAB based LEILA prototype software can analyze five frames-per-second standalone on standard desktop hardware. Conclusion: LEILA provides an automated approach to quantitatively monitor LD on MV images during DIBH treatment. Future improvements include a database and further speed optimization.

60 APPLIED LIFE SCIENCES↗

Poster - 35: Monitoring patient positioning during deep inspiration breath hold with a distance measuring laser

Purpose: The accuracy of treatment delivery for left breast/chest wall patients using deep inspiration breath hold (DIBH) is being monitored using a distance measuring laser (DML) Methods: A commercially available DML (DLS-C15, Dimetix) was mounted behind a Varian TrilogyTM linac. Relative to the machine isocenter, the laser from the beam was offset by 8 cm to the left and by 1 cm in the superior direction. This position was selected because this point is situated on the sternum for the majority of the left breast/chest-wall patients treated at our institution. The Varian Real-Time Positioning Management™ (RPM) guided DIBH treatments at our institution is delivered by placing the system’s tracking block on the patient’s abdomen. The treatment beam is enabled only when the block is in between a predefined abdomen motion range as determined during the CT simulation process. A LabVIEW program was developed to record both beam status (i.e. on/off) and distance measurements. In this study the DML was only used to monitor the position of a single point on the chest and no clinical decisions/adjustments were made based on these measurements. Results and Conclusions: Thus far, 34 fractions have been recorded for 4 patients. As such, the performance of our DIBH treatment technique cannot be fairly evaluated at this point. However, deviations between expected and measured distances have been observed and if these are found to be reproducible, then modifications in our treatment procedures and policies will have to take place.

60 APPLIED LIFE SCIENCES↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 11: Quantification of chest wall motion during deep inspiration breast hold treatments using cine EPID images and a physics based algorithm

Purpose: This work presents an algorithm used to quantify intra-fraction motion for patients treated using deep inspiration breath hold (DIBH). The algorithm quantifies the position of the chest wall in breast tangent fields using electronic portal images. Methods: The algorithm assumes that image profiles, taken along a direction perpendicular to the medial border of the field, follow a monotonically and smooth decreasing function. This assumption is invalid in the presence of lung and can be used to calculate chest wall position. The algorithm was validated by determining the position of the chest wall for varying field edge positions in portal images of a thoracic phantom. The algorithm was used to quantify intra-fraction motion in cine images for 7 patients treated with DIBH. Results: Phantom results show that changes in the distance between chest wall and field edge were accurate within 0.1 mm on average. For a fixed field edge, the algorithm calculates the position of the chest wall with a 0.2 mm standard deviation. Intra-fraction motion for DIBH patients was within 1 mm 91.4% of the time and within 1.5 mm 97.9% of the time. The maximum intra-fraction motion was 3.0 mm. Conclusions: A physics based algorithm was developed and can be used to quantify the position of chest wall irradiated in tangent portal images with an accuracy of 0.1 mm and precision of 0.6 mm. Intra-fraction motion for patients treated with DIBH at our clinic is less than 3 mm.

60 APPLIED LIFE SCIENCES↗

Retina-inspired narrowband perovskite sensor array for panchromatic imaging

The retina is the essential part of the human visual system that receives light, converts it to neural signal, and transmits to brain for visual recognition. The red, green, and blue (R/G/B) cone retina cells are natural narrowband photodetectors (PDs) sensitive to R/G/B lights. Connecting with these cone cells, a multilayer neuro-network in the retina provides neuromorphic preprocessing before transmitting to brain. Inspired by this sophistication, we develop the narrowband (NB) imaging sensor combining R/G/B perovskite NB sensor array (mimicking the R/G/B photoreceptors) with a neuromorphic algorithm (mimicking the intermediate neural network) for high-fidelity panchromatic imaging. Compared to commercial sensors, we use perovskite “intrinsic” NB PD to exempt the complex optical filter array. In addition, we use an asymmetric device configuration to collect photocurrent without external bias, enabling a power-free photodetection feature. These results display a promising design for efficient and intelligent panchromatic imaging.

42 ENGINEERING↗