Search NASA⌕ Search

SEARCH · Search NASA

Results for “Induced Currents”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

An efficient solution of low-frequency magnetic problems with voltage sources using all-frequency stable formulation

The modeling and simulation of magnetic problems at low frequencies are considered in this paper. When excited with a voltage source, conduction current is induced in the circuit of interest, which generates the magnetic field. This type of problems is modeled using the all-frequency stable formulation, which employs the potential description of fields with an inhomogeneous Coulomb gauge. With the aid of the stable formulation, the low-frequency breakdown problem is circumvented and both electric and magnetic fields can be solved in a single simulation. To solve large magnetic problems efficiently, it is necessary to employ an iterative solver with an efficient preconditioner. In this work, a preconditioner based on the incomplete LU decomposition is constructed and applied in a wide frequency range. Several numerical examples are given to demonstrate the performance of the proposed method.

Mekonnen, Minyechil↗

Giant Modulation of Magnetoresistance in a Van Der Waals Magnet by In‐Plane Current Injection

Efficient magnetization control is a central issue in magnetism and spintronics. Particularly, there are increasing demands for manipulation of magnetic states in van der Waals (vdW) magnets with unconventional functionalities. However, the electrically induced phase transition between ferromagnetic-to-antiferromagnetic states without external magnetic field is yet to be demonstrated. Here, the current-induced magnetic phase transition in a vdW ferromagnet Fe 5 GeTe 2 is reported. Based on magneto-transport measurements and theoretical analysis, it is demonstrated that transition in the interlayer magnetic coupling occurs through vertical voltage drop between layers induced by current which is attributed to high anisotropy of the resistivity caused by the vdW gaps. Such magnetic phase transition results in giant modulation of the longitudinal magnetoresistance from 5% to 170%. The electrical tunability of the magnetic phase in Fe 5 GeTe 2 with current-in-plane geometry opens a path for electric control of magnetic properties, expanding the ability to use vdW magnets for spintronic applications.

2D magnet↗

First Differential Measurement of the Single 𝜋 + Production Cross Section in Neutrino Neutral-Current Scattering

Since its first observation in the 1970s, neutrino-induced neutral-current single positive pion production (NC⁢1⁢𝜋 + ) has remained an elusive and poorly understood interaction channel. This process is a significant background in neutrino oscillation experiments and studying it further is critical for the physics program of next-generation accelerator-based neutrino oscillation experiments. In this Letter, we present the first double-differential cross-section measurement of NC⁢1⁢𝜋 + interactions using data from the ND280 detector of the T2K experiment collected in 𝜈-beam mode. The measured flux-averaged integrated cross section is 𝜎 = (6.07 ± 1.22) × 10 −41 cm 2 /nucleon. We compare the results on a hydrocarbon target to the predictions of several neutrino interaction generators and final-state-interaction models. While model predictions agree with the differential results, the data show a weak preference for a cross-section normalization approximately 30% higher than predicted by most models studied in this Letter.

Neutrino detection↗

Challenges in Continuous In-Field Critical Current Testing of High-Temperature Superconducting Tapes: Thermal and Mechanical Perspectives

High-temperature superconductors (HTS) are essential for ultra-high-field applications requiring exceptional current-carrying capacity under extreme conditions. However, systematic characterization of critical current in long-length conductors remains challenging due to complex thermal, electromag netic, and mechanical interactions during continuous testing. This study reports the development of a continuous in-field magnetization testing system for position-dependent critical current measurement in HTS tapes at 20 K under 7.5 T fields applied normal to the tape plane, enabling identification of performance-limiting regions that could compromise magnet stability. Here, the system addresses two fundamental challenges inherent to cryogenic reel to-reel testing. First, thermal management requires continuous cooling of a moving conductor to 20 K, achieved through liquid nitrogen precooling combined with a 100 W@20 K Gifford McMahon cryocooler. Second, screening currents in high fields generate Lorentz forces that induce twisting, bowing, and potential delamination. To mitigate these risks, we propose mechanical reinforcement and active current density suppression strategies. Numerical simulations using the stream function formulation reveal four primary failure modes: frictional heating at guide interfaces, unstable equilibria causing deformation, transverse current-induced stresses at guide transitions, and unsupported forces in vertical spans. Our mitigation strategies include PTFE coated guides to minimize friction, spring-loaded stabilization mechanisms to maintain tape alignment, controlled pre-heating using the liquid nitrogen thermal jacket to suppress critical current at stress points, and optimized guide positioning to minimize force accumulation. The experimental system is nearing completion, with testing planned to commence within two months. Preliminary validation at 65 K under 0.5 T demonstrates strong correlation between simulation-predicted mechanical instabilities and observed critical current variations during conductor tran sitions through the measurement region. These findings establish a robust foundation for quality assurance protocols essential to next-generation superconducting magnet applications.

Chen, Siwei [Princeton Plasma Physics Laboratory (↗

Characterization of ELM pacing via vertical jogs on DIII-D

Edge localized mode (ELM) pacing via vertical plasma oscillations or jogging has been successfully demonstrated on DIII-D. Rapid vertical movement of the plasma toward the X-point has been shown to effectively trigger ELMs. By vertically oscillating the plasma at a rate of 10 Hz, the ELM frequency increased from ~5 Hz, the natural ELM frequency in similar DIII-D discharges, to 20 Hz. Downward jogs have been observed to trigger multiple ELMs in one cycle. ELMs triggered at higher than natural frequencies lead to smaller decreases in stored energy, from 8% to as little as below 1%. As a consequence, the peak heat flux to the divertor has been observed to be reduced by a factor of ~2. In addition, a reduction in the carbon impurity concentration has been observed. During downward jogs in the lower single null (LSN) configuration, the X-point movement is slower and smaller than the top of the plasma. As a result, a reduction in the plasma cross-section and hence volume has been observed. To understand the mechanism of ELM triggering by jogging, a toy model of the edge toroidal current has been built and tested with DIII-D experiment data. The experimental data and model suggest that when the plasma moves down toward the X-point, a net positive toroidal current is locally induced in the edge region. ELITE stability analysis suggests that this current pushes the plasma state across the peeling side of the peeling–ballooning stability boundary into the unstable region triggering ELMs.

ELM pacing↗

An Inrush Current Limit Method for SiC-based Multi-level Grid-connected Converter During Low-Voltage Ride-Through

Low-voltage ride-through is one of the grid requirements for grid-connected converters, and during the transient of grid voltage change, a large inrush current could be induced due to the control delay of the converter. This inrush current is more severe in SiC-based multi-level converters due to the small filter inductance, which is selected based on harmonics consideration. In this paper, a PWM mask method is used to limit the inrush current of a cascaded H-bridge-based grid-connected converter during the transient of grid voltage change. Simulation and experiment results are provided to validate this method.

Li, Haiguo↗

Experimental determination of critical resolved shear stress for strain-induced phase transformation

The current investigation reports the first attempt to measure the critical resolved shear stress to initiates strain-induced phase transformation in a three-dimensional polycrystalline aggregate using high-energy diffraction microscopy (HEDM). In situ tensile testing was performed on a Fe38.5Mn20Co20Cr15Si5Cu1.5 metastable alloy exhibiting transformation-induced plasticity (TRIP). Grains with a higher propensity for strain-induced phase transformation were tracked using HEDM. A sharp drop in grain specific stress, coinciding with the appearance of a new ε-hcp grain oriented relative to the parent γ-fcc phase, was taken as evidence of grain-specific stress required to trigger phase transformation. The highest resolved shear stress on the potential transformation systems was identified as the critical resolved shear stress (CRSS) for strain-induced phase transformation. For the studied metastable alloy, CRSS for transformation was determined to be 86±3 MPa which was very close to theoretical CRSS value determined using Schmid factor (89±12 MPa) compared to the value determined using Taylor factor (62±7 MPa).

Jain, Roopam↗

Measurement of 𝜋 0 production in $\bar{v}_μ$ charged-current interactions in the NOvA near detector

We present a high-statistics measurement of muon antineutrino-induced charged-current neutral pion production on a hydrocarbon target using the NOvA near detector. The differential cross sections as functions of the momenta and angles of the outgoing pion and muon, the squared four-momentum transfer, and the invariant mass of the hadronic system at an average neutrino energy of 2 GeV are measured and compared with predictions from various neutrino interaction models. The results agree with the GENIE prediction but suggest that other models underestimate the cross section in the Δ⁡(1232) resonance region. These results represent the most precise measurement of antineutrino-induced neutral pion production to date.

neutrino detection↗

ESR Dipole Power Supply Current Ripple and Noise Specifications

This note presents key findings for the ESR main magnet dipole power supplies (PS), where we find the current ripple specification to be close to or beyond the state-of-the-art. These specifications originate from beam-beam considerations, with the requirement to limit the ripple-induced hadron emittance growth to below 10%/hour. Beam dynamics that drive this PS ripple specification arise from the beam motions at the Interaction Point (IP). The frequency of the motions can be separated into "low", compared to the betatron frequency, and "high", i.e. around the betatron frequency and harmonics. In terms of the driving frequency, "low" implies ƒ<<ƒ 0 v x,y and "fast" means ƒ≈{ƒ 0 v x,y , ƒ 0 (1- v x,y , etc.}, where ƒ 0 =1/ T 0 =78.2 kHz is the revolution frequency, and v x,y are the fractional parts of the betatron tunes. Frequencies higher than ƒ 0 /2 will be folded back due to the particles sampling the field once per turn. To provide flexibility for future lattice adjustments and working point variations, we do not consider the tunes as fixed. Instead, we assume a certain margin and allow them to potentially fall within the range of 0.1< v x,y <0.5. In other words, the high-frequency region spans approximately from 8kHz to 40 kHz. Consequently,, we definte the dipole PS ripple in two distinct frequency ranges: the low-frequency range of [1-8000] Hz and the high-frequency range of [8-40] kHz. For the physics effects we analyzed in this note, there is no distinction between the ripple (which can be approximately reproduced in the frequency domain) and the random noise if both have some power within the frequency bandwidth of interest. Therefore, while we will use the term "ripple" for short, it should always be understood that we are referring to "ripple plus noise." Except for the lower end of the low-frequency range, the impact of the rippling PS current on the beam will be considerably reduced due to the eddy currents induced in the walls of the vacuum chamber. We will account for this effect in the PS ripple specifications to follow. The remaining sections of this note are structure as follows: Section II outlines the beam-beam physics requirements for the positional stability of the beam at the IP. Section III describes the anticipated shielding effect of the eddy currents induced in the vacuum chamber. Section IV derives the ripple requirement for the low-frequency range by propagating the closed orbit ripple resulting from the rippling dipoles to the IP (relevant lattice simulation results are summarized in the Appendix). In Section V, we present the analytical criterion for the ripple in the high-frequency range by considering resonant oscillations of the electron beam around a stable closed orbit near the betatron frequency. Finally, Section VI provides a summary of our findings and discusses related work.

43 PARTICLE ACCELERATORS↗

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

First Measurement of the Electron-Neutrino Charged-Current Pion Production Cross Section on Carbon with the T2K Near Detector

The T2K Collaboration presents the first measurement of electron neutrino-induced charged-current pion production on a predominantly carbon target in a restricted kinematical phase space. This is performed using data from the 2.5° off-axis near detector, ND280. The differential cross sections with respect to the outgoing electron and pion kinematics, in addition to the total flux-integrated cross section, are obtained. Comparisons between the measured and predicted cross-section results using the neut, genie, and nuwro Monte Carlo event generators are presented. The measured total flux-integrated cross section is [2.52 ± 0.52⁢(stat) ± 0.30⁢(syst)] × 10 −39 cm 2 nucleon −1 , which is lower than the event generator predictions.

Neutrinos↗

Electrical de-poling and re-poling of relaxor-PbTiO 3 piezoelectric single crystals without heat treatment

Re-poling of unexpected partially depoled piezoelectric materials conventionally needs to be first fully depoled through annealing above their Curie temperature to revive piezoelectric performances. Here, we investigated de-poling and re-poling of Pb(In 1/2 Nb 1/2 )O 3 -Pb(Mg 1/3 Nb 2/3 )O 3 -PbTiO 3 single crystals under electric fields at room temperature. We found that alternating current electric fields with amplitudes near the coercive field at low frequencies (<10 Hz) can be employed to successfully depolarize poled crystals at room temperature. We also demonstrated a reversible polarization switching process with a relaxor-PbTiO 3 single crystal ultrasound transducer without device performance degradations. This experimental observation is supported by phase-field simulation, showing that alternating current electric fields can readily induce de-poling at room temperature, while direct current electric fields induce a transient depoled state only within an uncontrollable short period of time. The findings suggest new strategies for unprecedented in-device tailoring of the polarization states of ferroelectric materials.

36 MATERIALS SCIENCE↗

High Statistics Measurements of $ν_μ$ Charged-Current Single $π^{+}$ Production with Zero Pion Kinetic Energy Threshold in MINERvA

This Letter presents measurements of single-differential cross sections of $ν_μ$-induced charged-current 1 $π^{+}$ production on scintillator using the MINERvA detector at Fermilab. These measurements use traditional track-based pion reconstruction as well as pions identified solely via Michel electron decays, allowing measurement of kinetic energies from 0 to 350 MeV. In total, 91,843 events were selected with $W_{exp}$$<$ 1.4 GeV/c. Differential cross sections as a function of pion and muon kinematic variables are presented and compared with the predictions of several neutrino event generators. Overall, modern pion production models tend to agree with data at the ends of the kinematic regions probed, but are discrepant with the main regions of the phase space probed by up to 15% in muon observables and up to 20% in pion observables. No model describes any of the variables well, and this result highlights model areas that require improvement for the next generation of neutrino oscillation experiments.

Granados, E. [Guanajuato U.]↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

Development of NDE/NDT Tools for High-Volume & High-Speed Inspection of CFRP Structures in Automotive Manufacturing

Main advantages of the air-coupled ultrasound testing (ACUT) and electromagnetic testing (EMT) techniques for NDE of CFRP composites were non-contact sensing, scalability for high-speed inspection, cost-effectiveness, and non-hazardous operation. Despite these advantages, no systems that would satisfy the project requirements were commercially available. Hence, one of the major efforts of the Michigan State University (MSU) team at the initial stage of the project was to close this technological gap by developing, optimizing, and validating array sensors that would provide sufficient sensitivity, spatial coverage, and resolution for robust defect detection. Optimization of the ACUT and EMT sensor designs was performed using experimentally validated finite element models. Initial experiments using array probes were conducted on relatively flat CFRP samples. In parallel, the MSU team designed and assembled a portable platform with two robotic arms. The robots were equipped with newly designed sensors that enabled high-speed NDE of curved CFRP parts. Presently, the developed robotic platform can be used as a demo/template NDE system, which is easily adaptable to manufacturing environments and in-line NDE. The ACUT NDE system developed by the MSU team used a high-power 4-channel pulser receiver for parallel data acquisition. The array probes were designed by stacking commercially available ACUT transducers, which operated in the frequency range between 100 kHz and 500 kHz. MSU optimized the excitation procedure and developed wave focusing cones so as to reduce the crosstalk between the transducers and to provide higher pulse repletion frequency (PRF). The through-transmission (TT) and single-side access (SSA) inspection modes were successfully implemented. In the TT-ACUT, structural defects in CFRP were detected by passing ultrasonic waves through the test part. Hence, the ACUT transmitters and receivers needed to be placed on the opposite sides of the test part. In the SSA-ACUT, guided waves (GW) were excited in the test part using the transmitters and were sensed by the receivers from the same side. Multi-channel TT-ACUT and SSA-ACUT provided high-speed NDE, and were successfully validated on CFRP test samples with interlaminar delaminations and other embedded defects The EM techniques developed by the MSU team included: 1) eddy current testing (ECT), 2) capacitive imaging (CI) and hybrid dual-mode imaging. In ECT, structural damage was detected in CFRP using coils sensor arrays. In ECT, the excitation magnetic field is generated by passing an alternating current through a coil, which is placed above the test sample. The excitation field penetrates the conductive sample and induces the eddy currents in its transect. In turn, the eddy currents generate the reaction field, which affects the total field sensed by a coil. Hence, the presence of structural flaws will alter the eddy current flow and the picked-up signal. ECT is mostly sensitive to local changes of the electric conductivity of the test sample, and CFRPs are mostly conductive in the direction of carbon fibers. Hence, ECT was well suited for the detection of fiber damage/fiber irregularities. The MSU team developed printed circuit boards (PCB) with coil sensor arrays optimized for NDE of CFRP. Unlike most commercial probes designed for ECT of metallic structures, the MSU array probes were designed for operation in [1-10] MHz frequency range, which was optimal for low-conductive CFRP. Multiple sensing topologies (coil groups excitation/sensing arrangements) were implemented and successfully validated. Capacitive Imaging (CI) technique developed by MSU was complementary to ECT. In contrast to ECT, which was sensitive to local changes of the electrical conductivity, the CI was sensitive to local changes of the dielectric constant. Therefore, CI could provide information about matrix damage/matrix irregularities in CFRP. The MSU CI sensor arrays were made of multiple circular or rectangular open-plate capacitors printed on PCB. Sensors of this type are not commercially available. In addition to ECT and CI, the MSU team developed a hybrid (dual-mode) inductive/capacitive measurement technique that synergistically combined the benefits of inductive and capacitive sensing for rapid NDE of fiber reinforced polymer (FRP) composite structures. Fiber damage and fiber irregularities in FRPs were detected by configuring hybrid sensors as coil sensors. Similarly, matrix damage, matrix irregularities and interlaminar delaminations were detected by configuring hybrid sensors as capacitive sensors. ECT and CI were performed sequentially by means of electronic switching. Hence, eliminating the need for mounting two separate sensor arrays on the probe. Portable robotic platform was developed by MSU for multi-technique high-speed NDE of CFRP test parts. The platform had two 6-axis robots, which enabled inspection of curved parts in approximately a 6×6×6 ft 3 active scan area. On the software side, the MSU team integrated scripts for NDE hardware control with scripts for robot motion control. MSU also implemented automated path planning for the robots, reconstruction of part’s surfaces via stereovision, 3D rendering of inspection data, and image processing algorithms for enhanced defect detection. Automotive composite parts manufactured by Plasan Composites from Phase I were used to validate the ACUT and EMT techniques on representative testbeds. Among those parts were three X-braces for a Dodge Viper, one composite calibration plaque with known defects at known locations, and four other test sections, including sections from a front splitter, a corner section from a composite hood, and a high-pressure RTM panel made using non crimp fabric. Other test samples included CFRP and GFRP calibration plates with fiber/matrix defects fabricated at MSU/CVRC.

36 MATERIALS SCIENCE↗

Electronic noise of a single skyrmion

To enable the practical use of skyrmion-based devices, it is essential to achieve a balance between energy efficiency and thermal stability while also ensuring reliable electrical detection against noise. Understanding how a skyrmion interacts with material disorder and external perturbations is thus essential. Here, we investigate the electronic noise of a single skyrmion under the influence of thermal fluctuations and spin currents in a magnetic thin film. We detect the thermally induced noise with a 1/ƒ $\gamma$ signature in the strong pinning regime but a random telegraph noise in the intermediate pinning regime. Both the thermally dominated and current-induced telegraphlike signals are detected in the weak pinning regime. Our results provide a comprehensive electronic noise picture of a single skyrmion, demonstrating the potential of noise fluctuation as a valuable tool for characterizing the pinning condition of a skyrmion. In conclusion, these insights could also aid in the development of low-noise and reliable skyrmion-based devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The current status of inelastic and capture Gamma-ray production evaluations in translated ENDF-VIII.0 GNDS files and recommended remediation actions

This report provides the status of discrete nuclear levels and inelastic gamma-ray production for neutron induced reactions in current ENDF-VIII.0 evaluations for the isotopes in the GRIN project. Different categories of issues are identified after a comparison with information from “adopted” ENSDF files. Improvement strategies are given and recommendations are described. We have included a similar, but more limited, analysis for thermal capture data where EGAF and ENSDF thermal libraries are considered. In addition, we provide a validation plan to employ different transport code simulations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Current-Driven Symmetry Breaking and Spin–Orbit Polarization in Chiral Wires

The spin dynamics of electrons in chiral molecular systems remains a topic of intense interest, particularly regarding whether geometric chirality inherently induces spin polarization in current-carrying electrons. In this work, we employ ab initio real-time time-dependent density functional theory (rt-TDDFT) to directly simulate the interplay among charge current, spin, and orbital. This realtime tracking extends beyond perturbative treatments, and we analyze how nonequilibrium currents effectively lift the symmetry constraints of screw rotation and time-reversal symmetry. We find that the emergence of spin and orbital angular momenta is dynamically correlated with a concomitant loss of translational (linear) momentum, which we interpret as an intrinsic consequence of current-driven symmetry lowering. The implications of this mechanism for chirality-induced spin selectivity and spintronics device design are discussed.

chiral wire↗