Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integral solution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Multimodal sensor fusion for real-time standoff estimation in directed energy deposition

In Laser Powder-based Direct Energy Deposition (LP-DED) systems, achieving consistency, precision and quality of produced parts requires tight control over printing parameters. One of the critical parameters is the standoff distance. Maintaining an optimal standoff height is crucial for achieving correct laser power density and powder catchment efficiency, as both laser and powder streams are focused at this distance. Here, this study introduces a novel approach using multimodal sensor fusion to predict standoff height in real-time. The proposed system integrates two low-profile, cost-effective sensors: an RGB coaxial camera and a high frequency and high dynamic range microphone. By utilizing a simple fully connected neural network, trained on a limited dataset, data fusion of these sensors allowed for the real-time prediction of the standoff height. The results demonstrate high resolution and accuracy of the predictions across multiple geometries and a wide range of standoff heights. This approach offers a simple, and cost-effective solution for real-time standoff height monitoring and lays the groundwork for future integration into commercial LP-DED systems.

42 ENGINEERING↗

Large Load Integration - Task List and Overview

Large Load Integration Tasks: Task 1 – Workshops Support stakeholder engagement across industry to promote collaboration and identify solutions to challenges that will guide other work Task 2 – Ancillary Services Characterize different types of large loads to assess under what conditions they may be utilized to provide grid stability services Task 3 – Communications Explore the cybersecurity and communications infrastructure required to enable large loads to interface with grid operations to provide ancillary services Task 4 – Nuclear Integration Explore risks and methods for supporting large load energy needs with SMRs and incorporating them into the wider power system Task 5 – Decision Support and TA Provide support to stakeholders through the creation of planning tools and direct technical assistance.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Dissimilar Material Joining via Interlocking Metasurfaces

Background The integration of dissimilar materials poses a significant challenge in engineering, necessitating innovative solutions for robust and reliable joining. Interlocking metasurfaces (ILMs) are a new joining technology comprising arrays of autogenous features patterned across two surfaces that interlock to form robust structural joints. Objective Here, this study elucidates the factors influencing the tensile performance of ILM joints formed between dissimilar materials. Methods We employed parametric optimization to identify optimal unit cell geometries for maximal yield strength based on the hypothesis that the elastic tensile properties of the materials are the primary determinants of tensile performance. Experimental validation was performed by mechanically testing the theorized optimal ILM geometry and a range of ILM geometries to capture the overall behavior trends of joints between two additively manufactured polymers, VeroPureWhite (VW) and RGDA8430-DM (8430). Results Experimental validation of optimized designs revealed that additional factors, e.g. flexural strength and localized plasticity, also strongly influenced the tensile performance of T-slot ILMs joining dissimilar materials. The proposed optimal design remained the best performer. Conclusions This study demonstrates the viability of ILMs as a joining method for dissimilar materials. ILMs can join dissimilar materials with no loss in joint yield strength compared to joints composed solely of the weaker of the two constitutive materials. ILMs demonstrated their potential as a versatile and effective joining technology in diverse engineering applications.

Elbrecht, Benjamin James [Sandia National Laborato↗

Covalent adaptable networks for electrolyte–binder integration in recyclable lithium metal batteries

Lithium-metal batteries (LMBs) are considered a promising next-generation energy storage technology due to their exceptionally high energy density. However, the development of solid polymer electrolytes and cathode binders for LMBs faces critical challenges, including interfacial instability, poor recyclability, and growing environmental concerns. In particular, current systems often rely on non-recyclable components featuring permanently crosslinked networks and polyfluoroalkyl substances (PFAS), such as poly(vinylidene fluoride) (PVDF), which cause battery waste and environmental harm. Herein, we introduce a multifunctional covalent adaptable network (CAN) platform based on thermally reversible Diels–Alder (DA) chemistry, designed for dual functionality as a CAN-based electrolyte (CAE) and a CAN-based cathode binder. The CAE achieves high ionic conductivity and strong storage modulus (1.4 mS cm −1 and ∼ 10 5 Pa at room temperature, respectively) and enables stable long-term cycling in symmetric Li||Li cells for over 2000 h with low overpotential. When it is applied as a cathode binder in LiFePO 4 (LFP) composite electrodes (C-LFP), the CAN matrix significantly reduces interfacial resistance and enhances discharge capacity compared to conventional PVDF-based systems. Thermal treatment induces self-healing at the cathode–electrolyte interface, further improving contact and yielding a discharge capacity of 150 mAh g −1 at 0.5 C. Moreover, the dynamic CAN architecture allows efficient recovery and reuse of lithium salts from spent electrolytes through retro-DA reactions under mild conditions (∼80 °C), establishing a low-energy, cost-effective recycling pathway. In conclusion, this work presents a scalable and sustainable strategy for high-performance LMBs by integrating recyclability, interfacial healing, and PFAS-free design, offering a holistic solution aligned with circular economy principles and next-generation battery demands.

Diels–Alder↗

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Regeneration of anion-exchange resins for cyclic selenium removal from industrial wastewaters

Application of ion exchange for the removal of selenium (Se) oxyanions from industrial wastewaters is often limited by ineffective regeneration of the ion-exchange resins, particularly in complex systems containing competing ions, such as coal-ash leachate containing high-sulfate concentrations and heavy metal ions. Here, in this study, it was first demonstrated that while conventional regeneration with sodium chloride (NaCl) is effective for simulated wastewater, with ∼80% efficiency, NaCl fails to regenerate resin loaded with real industrial wastewater, achieving less than 20% efficiency. To overcome this challenge, a two-step regeneration process was investigated using a sodium carbonate (Na 2 CO 3 ) solution for elution, followed by a NaCl solution for restoration. Compared to the one-step NaCl regeneration, this integrated process restored more than 80% of the resin's capacity with real industrial wastewaters. Beyond demonstrating regeneration performance, this research emphasizes fundamental mechanistic interpretations of the observed regeneration behavior across different water matrices and experimental conditions. Particularly, accounting for pH-dependent carbonate speciation, it is proposed that the elution step exploits the resin's strong affinity for divalent carbonate ions to displace strongly bound contaminants, while the subsequent restoration step relies mainly on the mass action effects of chloride ions to regenerate the resin sites. The protocol was optimized to achieve rapid regeneration (<10 min) using moderate chemical concentrations (0.5 M) in treating real leachate. In batch cyclic experiments, Se regeneration reached nearly complete recovery after five consecutive sorption and desorption cycles, while in the fixed-bed system, the regeneration efficiency remained at approximately 80% after five cycles.

Anion-exchange resin↗

Enabling ITO-free perovskite solar cells through n-doped poly(benzodifurandione) (n-PBDF) electrodes

The burgeoning commercialization of perovskite solar cells (PSCs) is propelled by their exceptional power conversion efficiency (PCE), enhanced stability, and ease of fabrication. However, the rigidity of mainstream transparent conductive oxides (TCOs) limits the adaptability of PSCs to various application scenarios. Although alternative materials such as silver nanowires, carbon nanotubes, graphene, and PEDOT:PSS have been evaluated, the p-type nature confines their device designs to inverted architecture and restricts broader applicability. Here, for the first time, a conducting polymer electrode based on n-doped poly(benzodifurandione) (n-PBDF) was used to replace TCOs in PSCs. The n-PBDF electrodes can be readily fabricated via low-temperature, solution-based processes, indicating substantial potential for reducing manufacturing costs. Furthermore, its integration into PSCs has negligible effect on the phase, morphology, or photophysical properties of the perovskite layer, which is comparable to the typical TCOs. After optimization, the n-PBDF-based device achieves a power conversion efficiency of 12.70 and 11.23%, for rigid and flexible devices, respectively. Our study provides a promising alternative to the widely used TCOs in PSCs, highlighting the advantages of using n-doped conducting polymers in terms of processability and flexibility.

Kumar, Prashant [Purdue University, West Lafayette↗

The Physics Imposed on a Streaming Operator by Spherical Transport Problems

The streaming operator, which generates a displacement of a particle on a straight line at a constant speed in transport theory, is derived algebraically from a spherical coordinate formulation of Newton’s second law. This derivation leads to an operator that has more partial derivatives than a Cartesian coordinate formulation of the operator. The additional partial derivatives, which are with respect to the normalized velocity variables of a particle, take into account the intrinsic curvature of a ball. Moreover, these partial derivatives mitigate ray effects, which arise when a finite number of normalized velocities (also called directions or discrete ordinates) are used to simulate a continuous S 2 sphere of directions, by rotating the polar axis of the S 2 sphere into the radial direction of the coordinate system. As a consequence of this rotation, the number of actual discrete ordinates is greatly amplified to an enormous number of effective discrete ordinates by a multiplier that is equal to the number of patches that partitions a spherical surface. In addition to the derivation of the streaming operator, we provide in closed form a solution to the system of characteristic equations that is equivalent to the streaming operator. Furthermore, the solution to the system of characteristic equations enables the construction of an integral operator that is the inverse to the streaming operator. Examples in which ray effects are immensely mitigated by spherical coordinates are presented.

integral operator↗

eLog analysis for accelerators: status and future outlook

This work demonstrates electronic logbook (eLog) systems leveraging modern AI-driven information retrieval capabilities at the accelerator facilities of Fermilab, Jefferson Lab, Lawrence Berkeley National Laboratory (LBNL), SLAC National Accelerator Laboratory. We evaluate contemporary tools and methodologies for information retrieval with Retrieval Augmented Generation (RAGs), focusing on operational insights and integration with existing accelerator control systems. The study addresses challenges and proposes solutions for state-of-the-art eLog analysis through practical implementations, demonstrating applications and limitations. We present a framework for enhancing accelerator facility operations through improved information accessibility and knowledge management, which could potentially lead to more efficient operations.

Accelerator Physics↗

CI-MOR Final Report: Analysis and Validation of Critical Infrastructure Models using Model Order Reduction

This report summarizes the research and capabilities developed as part of the project “Analysis and Validation of Critical Infrastructure Models using Model Order Reduction” (CI-MOR) LDRD project. CI-MOR research enables the solution of large, complex optimization models that naturally arise in national security challenges involving critical infrastructures. Specifically, CI-MOR researchers developed methods to (1) rigorously approximate complex, nonlinear optimization formulations, (2) identify alternative near-optimal solutions, (3) accelerate optimization workflows used for complex applications, and (4) rigorously integrate domain knowledge in stochastic-process models. This report provides an overview of the research done in CI-MOR, and we describe application exemplars used to illustrate CI-MOR capabilities. Furthermore, we describe the software developed by CI-MOR that researchers can leverage to analyze new applications.

97 MATHEMATICS AND COMPUTING↗

eLog Analysis for Accelerators: Status and Future Outlook

This work demonstrates electronic logbook (eLog) systems leveraging modern AI-driven information retrieval capabilities at the accelerator facilities of Fermilab, Jefferson Lab, Lawrence Berkeley National Laboratory (LBNL), SLAC National Accelerator Laboratory. We evaluate contemporary tools and methodologies for information retrieval with Retrieval Augmented Generation (RAGs), focusing on operational insights and integration with existing accelerator control systems. The study addresses challenges and proposes solutions for state-of-the-art eLog analysis through practical implementations, demonstrating applications and limitations. We present a framework for enhancing accelerator facility operations through improved information accessibility and knowledge management, which could potentially lead to more efficient operations.

Hellert, Thorsten [LBNL, ALS]↗

MegaWatt Mayhem: Grid Operator Challenges Center Loads

This report provides a summary of the challenges faced by United States electricity grid operators in accommodating and anticipating the rapid deployment of large loads, particularly data centers, based on academic literature and industry working groups. The report highlights the unique requirements and operational characteristics of data centers, which differ significantly from traditional industrial loads. Key issues addressed utility planning considerations, with emphasis on the implications for grid operators, impacts to normal operations for grid operators, reliability considerations during periods of grid stress, and resilience considerations for the changing operational paradigms based on data centers. Real-world examples are used to highlight these challenges and the changes that grid operators must address. The findings underscore the necessity for coordinated efforts and innovative solutions from both grid operators and regulatory bodies to ensure the stable integration of large loads into the grid. This report is the first in a series that will explore the challenges of data center deployments based on several key power system perspectives.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

eLog analysis for accelerators: status and future outlook

This work demonstrates electronic logbook (eLog) systems leveraging modern AI-driven information retrieval capabilities at the accelerator facilities of Fermilab, Jefferson Lab, Lawrence Berkeley National Laboratory (LBNL), SLAC National Accelerator Laboratory. We evaluate contemporary tools and methodologies for information retrieval with Retrieval Augmented Generation (RAGs), focusing on operational insights and integration with existing accelerator control systems. The study addresses challenges and proposes solutions for state-of-the-art eLog analysis through practical implementations, demonstrating applications and limitations. We present a framework for enhancing accelerator facility operations through improved information accessibility and knowledge management, which could potentially lead to more efficient operations.

Sulc, A. [LBL, Berkeley]↗

Numerical modeling of electromagnetic field spatiotemporal evolution to evaluate the effects on calcium carbonate crystallization

Calcium carbonate (CaCO 3 ) scaling is a significant impediment to water systems. Electromagnetic field (EMF) treatment is a promising approach to control scaling owing to its simplicity and low or no energy requirements. However, the underlying mechanisms by which EMF impacts CaCO 3 crystallization remain unclear due to the challenges in measuring the EMFs in feed solutions and the lack of a fundamental understanding of the applied EMFs and the observed physicochemical phenomena. To fill this knowledge gap, a high-fidelity COMSOL model was first developed to simulate EMFs in bulk solutions for three alternating current-induced EMF devices with different configurations and properties. These were then integrated with experimental data to unveil the underlying mechanism by which applied EMFs alter the physicochemical processes. The study revealed that even low-strength EMFs (e.g., electric fields <0.15 V/m and magnetic fields <0.03 mT) promoted CaCO 3 precipitation in bulk solutions. The electric fields created by these EMF devices resulted in higher Lorentz force compared to their induced magnetic fields. In conclusion, the methodology of this study offers the capability to predict the effectiveness of different EMF devices in facilitating crystallization processes, and these mechanistic insights lay the foundation for the smart design of EMF devices for diverse water treatment applications.

COMSOL simulation↗

Modified Andronov-Hopf Oscillator-Based Grid-Forming Converter with Emulated Virtual Cable for Enhanced Power Sharing Performance

Nonlinear oscillator-based grid-forming converters offer superior dynamic and steady-state performance, making them an attractive solution for interconnecting renewable resources. This paper proposes a novel modified Andronov-Hopf oscillator to enhance the operating spectrum and facilitate the integration of renewable energy sources. An inner loop controller based on the Lyapunov energy function is implemented to achieve robust stability and performance, while a virtual cable emulation strategy enables seamless parallel operation. Comprehensive modeling and simulation studies validate the effectiveness of the proposed system, demonstrating its capabilities in addressing diverse operating scenarios, including grid faults, renewable energy fluctuations, and parallel operation. The proposed solution exhibits fast transient response, robust stability, and flexible operation, making it a valuable contribution to the field of renewable energy integration. The results of this study can be used to inform the design and implementation of next-generation grid-forming converters, enabling a more sustainable and reliable energy future. Additionally, the proposed system's ability to operate in both grid-connected and islanded modes makes it an ideal candidate for remote and off-grid renewable energy applications. The proposed solution's scalability and modularity also make it suitable for large-scale renewable energy integration. The proposed system is verified through MATLAB/Simulink and PLECS simulations, demonstrating its effectiveness in ensuring robust and efficient operation.

Andronov-Hopf Oscillator (AHO)↗

Specific iron binding to natural sphingomyelin membrane induced by non-specific co-solutes

Sphingomyelin (SPM), a crucial phospholipid in the myelin sheath, plays a vital role in insulating nerve fibers. We hypothesize that iron ions selectively bind to the phosphatidylcholine (PC) template within the SPM membrane under near-physiological conditions, resulting in disruptions to membrane organization. These interactions could potentially contribute to the degradation of the myelin sheath, thereby playing a role in the development of neurodegenerative diseases. We utilized synchrotron-based X-ray spectroscopy and diffraction techniques to study the interaction of iron ions with a bovine spinal-cord SPM monolayer (ML) at the liquid-vapor interface under physiological conditions. The SPM ML serves as a model system, representing localized patches of lipids within a more complex membrane structure. The experiments assessed iron binding to the SPM membrane both in the presence of salts and with additional evaluation of the effects of various ion species on membrane behavior. Grazing incidence X-ray diffraction was employed to analyze the impact of iron binding on the structural integrity of the SPM membrane. Furthermore, our results demonstrate that iron ions in dilute solution selectively bind to the PC template of the SPM membrane exclusively at near-physiological salt concentrations (e.g., NaCl, KCl, KI, or CaCl 2 ) and are pH-dependent. In-significant binding was detected in the absence of these salts or at near-neutral pH with salts. The surface adsorption of iron ions is correlated with salt concentration, reaching saturation at physiological levels. In contrast, multivalent ions such as La 3+ and Ca 2+ do not bind to SPM under similar conditions. Notably, iron binding to the SPM membrane disrupts its in-plane organization, suggesting that these interactions may compromise membrane integrity and contribute to myelin sheath damage associated with neurological disorders.

59 BASIC BIOLOGICAL SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Two Spacers, One Perovskite: Integrating Ruddlesden–Popper and Dion–Jacobson Halide Perovskites

Hybrid organic–inorganic perovskites are a rapidly developing class of materials due to their desirable properties for optoelectronic applications such as their ease of synthesis, solution-processable film formation, tunable band gap, strong photoluminescence, good charge carrier mobilities, and high defect tolerance. Here, we present a novel 2D perovskite motif that seamlessly integrates the structural elements from both Ruddlesden–Popper and Dion–Jacobson halide perovskites. We demonstrate the incorporation of two different organic spacer cations in an ordered manner in 5 novel 2D perovskite iodide materials. Both a cyclic diammonium cation 3-(aminomethyl)piperidinium (3AMP) and a linear alkyl monoammonium cation (Cn = C n H 2n+4 N, n = 4–8) are present in distinct alternating layers, making the new series (Cn) 2 (3AMP)[PbI 4 ] 2 . The crystallization of these materials was optimized through careful temperature control to obtain precise crystal structures via single-crystal X-ray diffraction (XRD) which confirmed the presence of the two cations in distinct layers. The influence of the two spacers on optical properties including the band gaps and photoluminescence spectra are found to more closely resemble (3AMP)PbI 4 than (Cn) 2 PbI 4 , which can be attributed to the amount of distortion imposed by the 3AMP spacer on the lead iodide layers. The findings are supported by density functional theory calculations. The strong photoelectric response of solution-processed thin films shows the potential of these materials in photodetectors or photovoltaics. This unprecedented amalgamation of RP–DJ in (Cn) 2 (3AMP)[PbI 4 ] 2 in a structurally ordered fashion suggests a potential vastly underexplored phase space of 2D perovskites in which there are chemically different spacers in distinct layers of the structure, providing an additional parameter to tune perovskite properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗