Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated Sensor Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of real-time density feedback control on MAST-U in L-mode

In this paper we report on the development and demonstration of density feedback control for MAST-U. Sinusoidal perturbations are used to measure the frequency response from a deuterium gas valve (actuator) to line-integrated core electron density measured by the interferometer (sensor). In the frequency range relevant for control design, only two system-identification experiments were needed to regress a first-order dynamic model. This control-oriented model informs the offline design of a proportional integral controller with the established loop-shaping controller design method. After offline verification of the controller implementation, control is demonstrated by experimentally tracking a staircase reference for the line-integrated electron density. This paper demonstrates the efficiency of controller design using system-identification and loop-shaping, providing reliable density control for MAST-U.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

DOE Hybrid and Electric Vehicle Test Platform

Based on the contract NT-42790 to the Department of Energy, “Plug-in Hybrid Ethanol Research Platform”, Advanced Vehicle Research Center (AVRC) Virginia has successfully developed the phase I electric drive train research platform which has been named as Laboratory Rapid Application Testbed (LabRAT). In phase II, LabRAT is to be upgraded into plug-in hybrid research platform, which will be capable of testing power systems for electric vehicles, and plug-in hybrid electric vehicles running on conventional as well as alternative fuels. LabRAT is configured as a rolling testbed with plentiful space for installing various component configurations. Component connections are modularized for flexibility and are easily replaced for testing various mechanisms. LabRAT is designed and built as a full functional vehicle chassis with a steering system, brake system and four wheel suspension. The rear drive axle offers maximum flexibility with a quickly changeable gear ratio final drive to accommodate different motor speed requirements. The electric drive system includes an electric motor which is mechanically connected to the rear axle through an integrated speed/torque sensor. Initially, a 100 kW UQM motor and corresponding UQM motor controller is used which can be easily replaced with another motor/controller combination. A lithium iron phosphate (LiFePO4) battery pack is installed, which consists of 108 cells of 100 AH capacity, giving the total energy capacity of 32.5 kWh. Correspondingly, a fully functional battery management system (BMS) is installed to perform battery cell operation monitoring, cell voltage balancing, and reporting battery real time operating parameters to vehicle controller. An advanced vehicle controller ECU is installed for controlling the drive train. The vehicle controller ECU receives traction or braking torque command from driver through accelerator and brake pedal position sensors and battery operating signals from the BMS through CAN BUS, and then generates motor torque command (traction or braking) to the motor controller based on the control algorithm software embedded in the vehicle controller ECU. The vehicle controller ECU is a re-programmable electronic control unit. Any control algorithm software developed can be easily downloaded to vehicle controller ECU to test any newly developed control strategy. The flexibility of the control system significantly enhances the practical applicability of the LabRAT. A new test methodology has been developed for the LabRAT simulating any vehicles running on road with different weights from compact passenger car to light duty truck on an AC or eddy current dynamometers without much effort for modification of the system. LabRAT is equipped with a fully functional data acquisition system supplied by CyberMetrix. The measurement points along the drive train are DC electric power between battery pack and motor controller input, AC electric power between motor controller and electric motor, mechanical power between motor and rear axle. The data acquisition system is designed with more capability than current requirements in order to meet the requirements for phase II.

33 ADVANCED PROPULSION SYSTEMS↗

Bidirectional Suzuki Catalyst Transfer Polymerization of Poly( p -phenylene)

Suzuki catalyst transfer polymerization (SCTP) has emerged as an effective method for accessing length-controlled π-conjugated poly(p-phenylene). Regio-controlled functional group sequencing along the backbone and the chain ends of synthetic polymers remains a challenge for the successful integration of organic semiconductors in sensors and electronic devices. Here, we report a bidirectional SCTP system based on dinuclear palladium(II) initiators. Functional groups transferred during the initiation and termination steps unlock independently addressable synthetic handles at the polymer core and respective chain ends. These functional groups open opportunities for late-stage regio-controlled and chemoselective derivatizations. Control over key polymer parameters, including molecular weight (M n ), dispersity ( Đ = M w /M n ), degree of polymerization ( DP ), termination efficiency, and functional group interconversion, is corroborated by size exclusion chromatography (SEC) and NMR spectroscopy. The modular design of SCTP initiators, in combination with commercially available terminating groups, represents a highly flexible toolbox for late-stage polymer conjugation, e.g., chemoselective anchoring groups for integration with functional electronics or bioorthogonal conjugation for molecular sensing.

Aldehydes↗

Building-Integrated Microscale Sensors for CO 2 -Level Monitoring

This research effort enabled the development of new classes of small-scale sensing systems that use mass and/or electrochemical sensors to detect the presence of carbon dioxide (CO 2 ). The concentration of this gas within the indoor environment is an important metric, as it can help enable the use of variable speed ventilation fans in commercial and governmental buildings, thus saving a significant amount of energy. Furthermore, there is a pressing need for enhanced CO 2 sensing to improve the comfort and productivity of people in commercial and government buildings, including academic spaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Multi-Robot System for Autonomous Inspection of Nuclear Waste Tank Pits

This paper introduces the overall design plan, development timeline, and preliminary progress of the Autonomous Pit Exploration System project. This project aims to develop an advanced multi-robot system for the efficient inspection of nuclear waste-storage tank pits. The project is structured into three phases: Phase 1 involves data collection and interface definition in collaboration with Hanford Site experts and university partners, focusing on tank riser geometry and hardware solutions. Phase 2 includes the selection of sensors and robot components, detailed mechanical design, and prototyping. Phase 3 integrates all components into a cohesive system managed by a master control package which also incorporates digital twin and surrogate models, and culminates in comprehensive testing and validation at a simulated tank pit at the Idaho National Laboratory. Additionally, the system’s communication design ensures coordinated operation through shared data, power, and control signals. For transportation and deployment, an electric vehicle (EV) is chosen to support the system for a full 10 h shift with better regulatory compliance for field deployment. A telescopic arm design is selected for its simple configuration and superior reach capability and controllability. Preliminary testing utilizes an educational robot to demonstrate the feasibility of splitting computational tasks between edge and cloud computers. Successful simultaneous localization and mapping (SLAM) tasks validate our distributed computing approach. More design considerations are also discussed, including radiation hardness assurance, SLAM performance, software transferability, and digital twinning strategies.

Nuclear waste management↗

3D printed graphene-based self-powered strain sensors for smart tires in autonomous vehicles

The transition of autonomous vehicles into fleets requires an advanced control system design that relies on continuous feedback from the tires. Smart tires enable continuous monitoring of dynamic parameters by combining strain sensing with traditional tire functions. Here, we provide breakthrough in this direction by demonstrating tire-integrated system that combines direct mask-less 3D printed strain gauges, flexible piezoelectric energy harvester for powering the sensors and secure wireless data transfer electronics, and machine learning for predictive data analysis. Ink of graphene based material was designed to directly print strain sensor for measuring tire-road interactions under varying driving speeds, normal load, and tire pressure. A secure wireless data transfer hardware powered by a piezoelectric patch is implemented to demonstrate self-powered sensing and wireless communication capability. Combined, this study significantly advances the design and fabrication of cost-effective smart tires by demonstrating practical self-powered wireless strain sensing capability.

33 ADVANCED PROPULSION SYSTEMS↗

Development of an Advanced Integrated Operations Concept for Hybrid Control Rooms

The U.S. Nuclear Industry has an urgent need to reduce the operations and maintenance costs to remain economically competitive in today’s energy market. Measures to improve efficiency in operations will need to leverage technology in a way that safely transforms how plants are operated. This work describes the development of an integrated operations concept that integrates data from existing Instrumentation and Control (I&C) infrastructure, upgraded I&C systems, new sensors, and field technologies such as computer-based procedures to provide operators with centralized, streamlined instructions. The concept was developed to allow for an operator to remotely supervise many plant activities and to dramatically streamline plant operations and maintenance. This report describes the design philosophy, the analysis used to inform design, the implementation in the Human Systems Simulation Laboratory, and illustrates the design concept.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

An integral quality monitoring system for real-time verification of intensity modulated radiation therapy

Purpose: To develop an independent and on-line beam monitoring system, which can validate the accuracy of segment-by-segment energy fluence delivery for each treatment field. The system is also intended to be utilized for pretreatment dosimetric quality assurance of intensity modulated radiation therapy (IMRT), on-line image-guided adaptive radiation therapy, and volumetric modulated arc therapy. Methods: The system, referred to as the integral quality monitor (IQM), utilizes an area integrating energy fluence monitoring sensor (AIMS) positioned between the final beam shaping device [i.e., multileaf collimator (MLC)] and the patient. The prototype AIMS consists of a novel spatially sensitive large area ionization chamber with a gradient along the direction of the MLC motion. The signal from the AIMS provides a simple output for each beam segment, which is compared in real time to the expected value. The prototype ionization chamber, with a physical area of 22x22 cm{sup 2}, has been constructed out of aluminum with the electrode separations varying linearly from 2 to 20 mm. A calculation method has been developed to predict AIMS signals based on an elementwise integration technique, which takes into account various predetermined factors, including the spatial response function of the chamber, MLC characteristics, beam transmission through the secondary jaws, and field size factors. The influence of the ionization chamber on the beam has been evaluated in terms of transmission, surface dose, beam profiles, and depth dose. The sensitivity of the system was tested by introducing small deviations in leaf positions. A small set of IMRT fields for prostate and head and neck plans was used to evaluate the system. The ionization chamber and the data acquisition software systems were interfaced to two different types of linear accelerators: Elekta Synergy and Varian iX. Results: For a 10x10 cm{sup 2} field, the chamber attenuates the beam intensity by 7% and 5% for 6 and 18 MV beams, respectively, without significantly changing the depth dose, surface dose, and dose profile characteristics. An MLC bank calibration error of 1 mm causes the IQM signal of a 3x3 cm{sup 2} aperture to change by 3%. A positioning error in a single 5 mm wide leaf by 3 mm in 3x3 cm{sup 2} aperture causes a signal difference of 2%. Initial results for prostate and head and neck IMRT fields show an average agreement between calculation and measurement to within 1%, with a maximum deviation for each of the smallest beam segments to within 5%. When the beam segments of a prostate IMRT field were shifted by 3 mm from their original position, along the direction of the MLC motion, the IQM signals varied, on average, by 2.5%. Conclusions: The prototype IQM system can validate the accuracy of beam delivery in real time by comparing precalculated and measured AIMS signals. The system is capable of capturing errors in MLC leaf calibration or malfunctions in the positioning of an individual leaf. The AIMS does not significantly alter the beam quality and therefore could be implemented without requiring recommissioning measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Color Sensor Comparison for Solvent Extraction Processes

Idaho National Laboratory is building Beartooth, a test bed to advance research into nuclear fuel cycle reprocessing. This test bed will give researchers the opportunity to study solvent extraction processes. Beartooth extraction operations will include the use of centrifugal contactors designed for the recovery and purification of special nuclear material from spent fuel. This new test bed facility provides researchers with the opportunity to study innovative technologies. As part of that initiative, this project will integrate non-traditional (atypical to a solvent extraction process) measurement sensors into a system of contactors to determine the state-of-health. These non-traditional sensors have the potential to enhance nuclear safeguarding efforts and other process activities. The non-traditional sensors include accelerometers, acoustic microphones, colorimetric, pH, conductivity, viscosity, density, and infrared cameras. This report documents the testing and evaluation of two different colorimetric RGB sensors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A multi-modal sweat sensing patch for cross-verification of sweat rate, total ionic charge, and Na + concentration

Sweat sensors introduced in recent years have targeted a variety of sweat features and biomarkers for non-invasive health monitoring. Amongst these targets, reliable monitoring of sweat rate is crucial due to its modulation of sweat analyte concentrations and its intrinsic significance to numerous medical and physiological health conditions. In this paper, we present a sweat rate sensor structure comprising of electrodes with interdigitated fingers in a microfluidic channel. Each time the accumulating sweat impinges on an electrode finger, the sensor reports a jump in admittance that can be simply and efficiently counted to estimate sweat rate, overcoming selectivity limitations of previously reported sweat rate sensors. We further integrate an impedimetric sensor for measuring total ionic charge concentration and an electrochemical Na + sensor, together creating a multi-modal system for analyzing fluid and electrolyte secretion. We demonstrate how low analyte diffusion rates through this microfluidic device allow for multi-purpose sensor function, including utilizing the sweat rate sensor signal to corroborate total ionic sensor measurements. This cross-verification capability ensures data integrity in real time, satisfying a vital consideration for personalized healthcare technologies. We use the presented patch for continuous analysis of sweat rate, total ionic charge concentration, and Na + concentration during exercise, while demonstrating how multi-modal cross-verification brings new trust to sensor readings.

47 OTHER INSTRUMENTATION↗

Robust Structural Analysis and Design of Distributed Control Systems to Prevent Zero Dynamics Attacks

We consider the design and analysis of robust distributed control systems (DCSs) to ensure the detection of integrity attacks. DCSs are often managed by independent agents and are implemented using a diverse set of sensors and controllers. However, the heterogeneous nature of DCSs along with their scale leave such systems vulnerable to adversarial behavior. To mitigate this reality, we provide tools that allow operators to prevent zero dynamics attacks when as many as p agents and sensors are corrupted. Such a design ensures attack detectability in deterministic systems while removing the threat of a class of stealthy attacks in stochastic systems. To achieve this goal, we use graph theory to obtain necessary and sufficient conditions for the presence of zero dynamics attacks in terms of the structural interactions between agents and sensors. We then formulate and solve optimization problems which minimize communication networks while also ensuring a resource limited adversary cannot perform a zero dynamics attacks. Polynomial time algorithms for design and analysis are provided.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Innovative Natural Gas Technologies For Efficiency Gain In Reliable And Affordable Thermochemical Electricity Generation (INTEGRATE)

Hyper is a cutting-edge system that pairs computational models that simulate the response of different systems with physical components such as sensors and actuators to transfer said calculated response to the HyPer facility. Computational models must operate in real-time in order to resolve the system response when coupled to physical hardware. Real-time is defined by the minimal HyPer system response time of Δt = 0.080 s. The integration of these models serves as a foundation for performance characterization based on real-world SOFC hardware and paves the way for comprehensive fuel flexibility studies. This report underscores the innovative approach to cyber-physical system deployment at NETL’s HyPer Facility, highlighting the critical role of computational models in enhancing the performance and adaptability of energy technologies.

03 NATURAL GAS↗

Demonstration of an Automated System for Vertical Profiles of Volatile Organic Compounds

Volatile organic compounds (VOCs) play important roles throughout the atmosphere, many of which are altitude dependent. This highlights the need for easily deployable devices to sample VOCs across different atmospheric layers. To address this, we present the design and initial application of a Time Resolved Automated Volatile organIc compounds Sampling system (TRAVIS). VOCs are collected on sorbent tubes, which are subsequently analyzed by a thermal desorption gas chromatography mass spectrometry pipeline. TRAVIS leverages a piezoelectric pump with an integrated pressure sensor for precise (0.1% flow rate relative standard deviation) and accurate (−3 ± 2% error in VOC quantitation) measurements. Via deployment on a tethered balloon system over an agricultural area, TRAVIS is used to show consistent vertically resolved VOC concentrations in a well-mixed (i.e., turbulent) atmosphere (e.g., 5% relative standard deviation for isoprene) and vertically dependent concentrations for a stratified atmosphere (e.g., prior to boundary layer development). Furthermore, we also show VOC information from an intermittent plume via both targeted and untargeted analysis, highlighting future applications for spurious events in agriculture, air quality monitoring, and environmental impact. Overall, the development of TRAVIS represents a lightweight, accurate, sensitive, and precise VOC sampling module for the scientific community.

Aerosols↗

Fast timing with induced current detectors

Vertically integrated (3D) combinations of sensors and electronics offer the ability to fabricate small, fine pitch pixels with very small total capacitance monolithically integrated with complex circuitry. The small capacitance, enabled by the fine pixel pitch and low interconnect capacitance available in 3D hybrid bonding, provides excellent signal/noise with moderate power. This combination enables fabrication of integrated sensors and electronics with both excellent position and time resolution. We describe the capabilities of such a system and the limitations imposed by geometry and power. Furthermore, we illustrate how a similar geometry can be used to provide very fast timing of x-ray arrival in a thick sensor by utilizing the transient induced current in a field of pixels.

3D integration↗

A Review of Sensor Calibration Monitoring for Calibration Interval Extension in Nuclear Power Plants

Currently in the United States, periodic sensor recalibration is required for all safety-related sensors, typically occurring at every refueling outage, and it has emerged as a critical path item for shortening outage duration in some plants. Online monitoring can be employed to identify those sensors that require calibration, allowing for calibration of only those sensors that need it. International application of calibration monitoring, such as at the Sizewell B plant in United Kingdom, has shown that sensors may operate for eight years, or longer, within calibration tolerances. This issue is expected to also be important as the United States looks to the next generation of reactor designs (such as small modular reactors and advanced concepts), given the anticipated longer refueling cycles, proposed advanced sensors, and digital instrumentation and control systems. The U.S. Nuclear Regulatory Commission (NRC) accepted the general concept of online monitoring for sensor calibration monitoring in 2000, but no U.S. plants have been granted the necessary license amendment to apply it. This report presents a state-of-the-art assessment of online calibration monitoring in the nuclear power industry, including sensors, calibration practice, and online monitoring algorithms. This assessment identifies key research needs and gaps that prohibit integration of the NRC-approved online calibration monitoring system in the U.S. nuclear industry. Several needs are identified, including the quantification of uncertainty in online calibration assessment; accurate determination of calibration acceptance criteria and quantification of the effect of acceptance criteria variability on system performance; and assessment of the feasibility of using virtual sensor estimates to replace identified faulty sensors in order to extend operation to the next convenient maintenance opportunity. Understanding the degradation of sensors and the impact of this degradation on signals is key to developing technical basis to support acceptance criteria and set point decisions, particularly for advanced sensors which do not yet have a cumulative history of operating performance.

Calibration↗

Real-Time Cyber-Physical False Data Attack Detection in Smart Grids Using Neural Networks

Attacks on cyber-physical systems have recently increased in frequency, impact, and publicity. In this paper, a cyber-physical false data attack detection mechanism is proposed to protect the operation of power transmission and distribution systems by automatically inferring underlying physical relationships using cross-sensor analytics in order to detect sensor failures, replay attacks, and other data integrity issues in real-time. We investigate a neural network based mechanism acting on voltage and current readings resulting from a wide variety of load conditions on the IEEE 30-bus power system standard and compare its performance with a support vector machine based mechanism. Experiments showed that 99% detection accuracy of replay attacks was achieved using the proposed neural network mechanism. More importantly, we showed that the best approach was to not create physics-based features using what we knew about the system, but rather to use a neural network to automatically learn the laws, and then use the outputs of that to build a classifier to identify whether and where data spoofing occurs. Thus, it is preferable to infer and exploit the physics using a single machine learning solution

Ferragut, Erik M.↗

In-Containment Signal Acquisition and Data Transmission via Power Lines within High Dose Areas of Nuclear Power Plants

Signal acquisition and data transmission for innovative sensor systems and networks inside the containment of nuclear power plants (NPPs) is still a challenge with respect to safety, performance, reliability, availability, and costs. This especially applies to equipment upgrades for existing plants, special measurements, but also for new builds. This paper presents a novel method for efficient and cost-effective sensor signal acquisition and data transmission via power lines, in order to cope with the disadvantages of common system architectures that often suffer from poor signal integrity due to raw data transmissions via long cables, huge efforts and costs for installation, and low flexibility with respect to maintenance and upgrades. A transmitter-receiver architecture is proposed that allows multiplexing of multiple sensor inputs for unidirectional point-to-point transmission by superimposing information signals on existing AC or DC supply lines, but also on active and inactive sensor wires, or spare cables, using power line communication (PLC) technology. Based on commercial off-the-shelf (COTS) electronic parts, a radiation hard transmitter hardware is designed to operate in harsh environment within the containment during full plant operation. The system's modular approach allows application specific trade-offs between redundancy and throughput regarding data transmission, as well as various sensor input front-ends which are compatible with state of the art systems. PLC technology eliminates the need for costly installation of additional cables and wall penetrations, while providing a complementary and diverse communication technology for upgrades of existing systems. At the receiver side in low dose areas, signals are extracted from the power line, demodulated, and de-multiplexed, in order to regain the original sensor signal information and provide it either in analog or digital output format. Successful laboratory qualification tests, field trails, and a demonstrator setup installation within a NPP verify the overall performance of the proposed system. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗