Search NASA⌕ Search

SEARCH · Search NASA

Results for “JEFFERSON LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Final Booster Complex Design for the Jefferson Lab Electron Ion Collider*

In this work we show the final iteration of the design for the booster complex of the Jefferson Lab EIC, which would have brought the ions from an energy (proton) of 150 MeV up to 12.1 GeV. This complex would have consisted of two figure-8 rings. The Low Energy Booster (LEB) which would have accelerated its protons from 150 MeV to 8 GeV, and has had its lattice tweaked to increase the effectiveness of chromaticity cancellations. The High Energy Booster (HEB) would have brought the 8 GeV protons up to 12.1 GeV. The HEB would in the tunnel that was designed for the collider rings, sitting on top of them. It has had a bypass around the interaction region added, as well as a cooling solenoid installed.

Nissen, E. A.↗

An e-beam irradiation beamline at Jefferson Lab for 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS) remediation in wastewater

The Upgraded Injector Test Facility (UITF) at Jefferson Lab, providing a beam energy up to 10 MeV, is suitable for wastewater remediation research. To investigate the degradation of 1,4-dioxane and per- and polyfluoroalkyl substances (PFAS), widespread in wastewater and potential to be regulated in near future, a beamline for electron-beam irradiation has been designed, installed and successfully commissioned at the UITF. A solenoid with a peak axial magnetic field of up to 0.28 T and a raster were used to obtain a Gaussian beam profile with a transverse standard deviation of 15 mm. It was applied to irradiate 1,4-dioxane sample filled in the target cell that was designed to let the entire sample receive significant irradiation doses. The dose distribution and absorbed dose, few studied in the current publications, are necessary measures for the degradation mechanism investigation and have been innovatively achieved in this work using simulations which were calibrated with opti-chromic dosimeter rods directly exposed to the electron beam. This approach provides an important way for investigating the environmental remediation impact of electron-beam irradiation.

Li, Xi↗

Development of Advanced Beam Halo Diagnostics at the Jefferson Lab Free-Electron-Laser Facility

High average current and high brightness electron beams are needed for many applications. At the Jefferson Lab FEL facility, the search for dark matter with the FEL laser beam has produced some interesting results, and a second very promising experiment called DarkLight, using the JLab Energy-recovery-linac (ERL) machine has been put forward. Although the required beam current has been achieved on this machine, one key challenge is the management of beam halo. At the University of Md. (UMD) we have demonstrated a high dynamic range halo measurement method using a digital micro-mirror array device (DMD). A similar system has been established at the JLab FEL facility as a joint effort by UMD and JLab to measure the beam halo on the high current ERL machine. Preliminary experiments to characterize the halo were performed on the new UV FEL. In this paper, the limitations of the present system will be analyzed and a discussion of other approaches (such as an optimized coronagraph) for further extending the dynamic range will be presented. We will also discuss the possibility of performing both longitudinal and transverse (3D) halo measurements together on a single system.

43 PARTICLE ACCELERATORS↗

Signal Processing for Beam Loss Monitor System at Jefferson Lab

Ion Chamber and Photomultiplier Tube (PMT) are both used for beam loss monitor in the Machine Protection System (MPS) at Jefferson Lab. The requirements of signal processing of these detectors are different, so two VME-based signal processing boards, Beam Loss Monitor (BLM) board and Ion-Chamber board, were developed. The BLM board has fast response (< 1us) and 5 decades dynamic range from 10nA to 1 mA, while the Ion-Chamber board has 8 decades dynamic range from 100 pA to 10 mA and slower response. Both of boards provide functions of machine protection and beam diagnostics, and features of fast shutdown (FSD) interface, beam sync interface, built-in-self-test, remotely controlled bias signals, and on-board memory buffer.

Yan, J.↗

The Jefferson Lab tritium program of nucleon and nuclear structure measurements

In this work a series of experiments were performed in Hall A of Jefferson Lab in 2018 that used a novel tritium and helium-3 target system. These experiments took advantage of the isospin symmetry of these mirror nuclei to make precise measurements of isospin dependence in both nucleon and nuclear structure. We summarize here the design and properties of these cells, the physics measurements that have been published, and results currently under analysis from this program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of two data acquisition and processing systems of Moller polarimeter in Hall A of Jefferson Lab

Two data acquisition and processing systems are used simultaneously to measure electron beam polarization by Moller polarimeter in Hall A of Jefferson Lab (Newport News, VA, USA). The old system (since 1997) is fully functional, but is not repairable in case of malfunction (system modules arenot manufactured anymore). The new system (since 2010) based on flash-ADC is more accurate, but currently requires more detailed adjustment and further improvement. Description and specifications of two data acquisition and processing systems have been given. The results of polarization measurements during experiments conducted in Hall A from 2010 to 2012 are compared.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

CLAS12 and its initial Science Program at the Jefferson Lab Upgrade

An overview of the CLAS12 detector is presented and the initial physics program after the energy-doubling of the Jefferson Lab electron accelerator. Construction of the 12 GeV upgrade project has started October 2008. A broad program has been developed to map the nucleon's 3-dimensional spin and flavor content through the measurement of deeply exclusive and semi-inclusive processes. Other programs include forward distribution function to large $x_{B} \le 0.85$ and of the quark and gluon polarized distribution functions, as well as nucleon ground state and transition form factors at high $Q^2$. The 12 GeV electron beam and the large acceptance of CLAS12 are also well suited to explore hadronization properties using the nucleus as a laboratory

43 PARTICLE ACCELERATORS↗

Overview of Spin Structure Program at Jefferson Lab

An extensive experimental program to study spin physics at low and moderate four - momentum transfer, Q{sup 2}, has been pursued by Jefferson Lab during the last 15 years, with complementary measurements taking place in all 3 experimental halls. Our inclusive data with high statistical precision and extensive kinematic coverage allow us to better constrain the polarized parton distributions, to accurately determine various moments of spin structure functions, to test the spin content of valent quarks, and to investigate the effects of resonance excitations and higher twist, dominant in this kinematic regime. Our recent semi-inclusive and exclusive measurements have given us new avenues of exploration, and inspired a new generation of experiments planned with 12 GeV beam. Highlights from 6 GeV experimental program are discussed, along with the 12 GeV data projections, and expected impact on the NLO global fits and phenomenological models of valent spin structure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The hypernuclear physics program at Jefferson Lab

Missing mass spectroscopy of Λ hypernuclei using the (e, e' K⁺) re action has been performed in the past at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) by several experiments in Halls A and C. A new experimen tal campaign is expected to start running in 2026 in Hall C and to provide the first study of the isospin dependence in medium-mass hyperisotopes by populating $^{40}_Λ{K}$ and $^{48}_Λ{K}$ using isotopically enriched calcium targets [E12-15-008]. During this cam paign, it will be possible to study Λ interactions in nuclear matter using a lead target [E12-20-013]. Solid-state targets made of lithium, beryllium, boron [LOI12-23-013], and aluminum [LOI12-23-016] are considered to be included in the campaign. The use of the HKS and HES spectrometers together with thin target foils and high beam currents leads to a sub-MeV energy resolution, significantly better than in hadron beam experiments. Valuable information on few-body hyperon systems would be gained if helium targets were used [E12-19-002]. Using an additional spectrometer for measuring the decay-pion spectra could give access to the binding energies of light hyperfragments [LOI12-23-011]. The measurement of precise and accurate en ergy spectra of different hyperisotopes probes the Λ-N interaction in nuclei including the Λ-N-N interaction. The latter is assumed to play a key role for the stiffness of the nuclear equation of state relevant for the stability of neutron stars.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Making the Case for Jefferson Lab

This chapter is a personal account of the initial planning and competition for a new laboratory, which eventually became known as the Thomas Jefferson National Accelerator Facility, with the official nickname "Jefferson Lab." The period covered starts as far back as 1964, with the introduction of quarks, and extends up to the late 1980s after the initial team was assembled, the superconducting design was in place, and construction was well underway. I describe some of the major experiments that were proposed to justify the laboratory, reflect on the present status of those initially proposed experiments, and very briefly outline some of the new ideas that emerged after the laboratory was constructed. The science is presented in a simple manner intended for a lay audience, with some of the ideas illustrated by cartoons that were often used in popular lectures given during this period.

43 PARTICLE ACCELERATORS↗

Light monitoring system for the lead tungstate calorimeter in Hall D at Jefferson Lab

A new electromagnetic calorimeter composed of 1596 lead tungstate (PbWO 4 ) scintillating crystals has been constructed for the GlueX detector in Hall D at Jefferson Lab. The calorimeter is equipped with a light monitoring system that uses light-emitting diodes. The light monitoring system was fabricated, installed, and integrated into the GlueX trigger system. It was successfully operated during detector commissioning and data collection, providing monitoring of the detector response and verification of the calibration with a precision better than 1%. In conclusion, the paper describes the design, installation, and performance of the light monitoring system.

Lead tungstate calorimeter↗

The Meson Spectroscopy Program Using the Forward Tagger with CLAS12 at Jefferson Lab

The 12 GeV upgrade to the Continuous Electron Beam Accelerator Facility (CEBAF) will enable a new generation of experiments in hadronic nuclear physics at Jefferson Lab, seeking to address fundamental questions in QCD. For example, confirming the existence of exotic states, suggested by both quark models and lattice calculations, would allow gluonic degrees of freedom to be explored, and may help explain the role played by gluons in the QCD interaction. In Experimental Hall B, meson spectroscopy (the MesonEx experiment) will be performed using low Q2 electron scattering to produce quasi-real photons. The scattered electron is detected at small angles by the Forward Tagger device, determining the properties of the photon on an event-by-event basis. This technique has notable advantages over real photon beams, and over hadronic beam experiments, where most experimental data exists. This article will focus on the development of the Forward Tagger by the INFN Genova group, and the proposed MesonEx experiment.

Fegan, Stuart↗

The search for QCD in nuclei: A Jefferson lab perspective

We discuss the phenomenon of Color Transparency, and give an overview of the extensive experimental searches for signatures of QCD in nuclei at Jefferson Lab, Hall-C. The results from protons, pions and kaons are compared with each other and with results from hadron scattering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The Beam-Beam Effect and its Consequences for the Jefferson Lab EIC

In this work we address the effect of beam jitter on emittance growth as caused by the beam-beam effect on the Jefferson Lab Electron Ion Collider (JLEIC). This proposed collider would collide up to 100 GeV proton beams with up to 10 GeV electron beams. Due to the asymmetric rigidities of the beams and their non-linear lensing action on each other during a collision, collective effects can limit beam storage times. Using simulations we determined that one of JLEIC’s synchronization concepts would require a new set of software tools to accurately understand phase space evolution.

Nissen, Edward↗

The New 2nd-Generation SRF R&D Facility at Jefferson Lab: TEDF

The US Department of Energy has funded a near-complete renovation of the SRF-based accelerator research and development facilities at Jefferson Lab. The project to accomplish this, the Technical and Engineering Development Facility (TEDF) Project has completed the first of two phases. An entirely new 3,100 m{sup 2} purpose-built SRF technical work facility has been constructed and was occupied in summer of 2012. All SRF work processes with the exception of cryogenic testing have been relocated into the new building. All cavity fabrication, processing, thermal treatment, chemistry, cleaning, and assembly work is collected conveniently into a new LEED-certified building. An innovatively designed 800 m2 cleanroom/chemroom suite provides long-term flexibility for support of multiple R&D and construction projects as well as continued process evolution. The characteristics of this first 2nd-generation SRF facility are described.

43 PARTICLE ACCELERATORS↗

Spectrometer Optics Calibration for Jefferson Lab $ g_2^ p $ Experiment

The proton spin-dependent structure function gp2 in the resonance region has been measured in a recent experiment at Jefferson Lab's Hall A. The goal of this experiment is to determine the gp2 structure function in the Q2 region of 0.02-0.20 GeV2 by using a transversely polarized NH3 target. The Hall A High Resolution Spectrometers (HRS) were used to provide an inclusive measurement of scattered electrons at 5.69 deg. A pair of septum magnets were used to bend the 5.69 deg scatted electrons into the 12.5 deg spectrometers. A full optics calibration of the spectrometer is required to extract the kinematic quantities at the interaction vertex. However, the calibration procedure is challenging due to the complications from the strong transverse target field (2.5 T and 5.0 T) and the varied field configurations of the septum magnets. The details of the optics calibration and the progress will be described in this talk.

Gu, Chao↗