Directional dependence of equilibrated TLD-400 chips in multiple radiation fields

Fielding of thermoluminescent dosimeters (TLDs) for measurement of photon radiation dose in experiments is the standard practice for γ-irradiation facilities, pulsed power x-ray facilities, and reactor facilities at Sandia National Laboratories (SNL). Due to the high-dose experimental conditions and the mixed ( 1 n, γ) fields in these facilities, SNL radiation metrologists have historically used CaF 2 :Mn TLDs (also known as TLD-400). Recent inquiries to the radiation metrology staff have raised concerns that the aluminum-equilibrated TLD-400 chips may exhibit a directionally dependent response. The metrologists were asked whether the dose measured by the chip may be impacted by the angle of incidence on the equilibrated TLD. To provide a thorough answer to this query, a set of adjoint Monte Carlo radiation transport calculations was performed for three different equilibrated TLDs as well as bare TLD chips using the Integrated Tiger Series (ITS) code. The key feature of the adjoint calculations performed in this study is that each photon escaping the modeled geometry was tallied into angular bins to provide information on both the energy and angular dependence of the equilibrated chip. After the adjoint Monte Carlo calculations were completed, the resulting energy-dependent response function for each angular bin was convolved with multiple photon energy spectra representing various radiation facilities at SNL. The radiation facilities selected for analysis span a range of photon energies from approximately 1 keV up to approximately 20 MeV. Thus, the presented results are applicable to a wide variety of radiation facilities around the world. Although the bare TLD-400 chip was expected to display the largest variation due to the photon angle of impact on the dosimeter, the dosimeter with the thinnest aluminum equilibrator (SNL thin equilibrated TLD-400) was determined to have the biggest differential between the impact angle with the maximum dose ( D max ) and the impact angle with the minimum dose ( D min ). However, the SNL normal equilibrated TLD-400 chip demonstrated a dramatic reduction in that differential between maximum and minimum dose angles. The reduction in this differential is one of the dominant factors in experimenters’ choice to field these dosimeters at SNL radiation facilities. The results from the PNNL (Hanford) energy-flattening field capsule are consistent with the previous publications. The differential dose responses due to the photon impact angle indicate that experimenters should strive to field their TLD-400 dosimeters in a consistent manner to avoid additional uncertainty in the measurements based on dosimeter orientation.

Adjoint radiation transport↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

Toward fully coherent soft x-ray free-electron laser via echo-enabled harmonic generation in fourth generation synchrotron light sources

Having previously reported on bunching via echo-enabled harmonic generation (EEHG) as an effective way to improve the longitudinal coherence in the NSLS-II storage ring [X. Yang et al., Sci. Rep. 12, 9437 (2022)], we demonstrate that this EEHG scheme can be easily adopted to any fourth generation diffraction-limited synchrotron light source with significant benefits. The advantage of the scheme is that it requires no change of the lattice and is fully compatible with other beamlines. Since the EEHG performance is mainly determined by the momentum compaction, beam emittances, and beta functions of a SR lattice, we have identified these crucial parameters and successfully built a generalized model, which can predict the performance of nearly any SLS. Regarding the fourth generation SLSs, momentum compactions are often significantly smaller; thus, to cover the x rays with a photon energy of up to 1 keV, we utilize a specific design, including a 250 nm seed-laser wavelength. Our model predicts that for most of the current and future fourth generation SLSs, the EEHG scheme can produce significant prebunching up to harmonic 200 and, thus, generate a few MW scale peak power at 1.25 nm wavelength.

47 OTHER INSTRUMENTATION↗

A platform for non-local thermodynamic equilibrium atomic physics research using the buried layer target approach at a kJ level laser facility

Here we present a design and first use of a kJ level laser facility for research of non-local thermodynamic equilibrium atomic physics using the buried layer target method. The target design included a metal layer buried inside a plastic tamper with thicknesses tailored to the expected laser intensities. The target was illuminated from each side by two laser beams with intensities of 0.5–5 × 10 14 W/cm 2 . The advanced diagnostic suite included static and time-resolved imagers and spectrometers with various spectral resolutions. A 3D printed dual elliptically curved spectrometer is presented, and its results are compared to a traditional crystal spectrometer. Experimental results and radiation hydrodynamic simulations demonstrate that the target achieved the desired thermodynamic conditions of n e ≈ 10 21 –10 22 cm -3 and T e ≈ 1–2 keV.

3D printing↗

Efficient backward x-ray emission in a finite-length plasma irradiated by a laser pulse of picosecond duration

Motivated by experiments employing picosecond-long, kilojoule laser pulses, we examined x-ray emission in a finite-length underdense plasma irradiated by such a pulse using two-dimensional particle-in-cell simulations. We found that, in addition to the expected forward emission, the plasma also efficiently emits in the backward direction. Our simulations reveal that the backward emission occurs when the laser exits the plasma. The longitudinal plasma electric field generated by the laser at the density down-ramp turns around some of the laser-accelerated electrons and re-accelerates them in the backward direction. As the electrons collide with the laser, they emit hard x rays. The energy conversion efficiency is comparable to that for the forward emission, but the effective source size is smaller. We show that the picosecond laser duration is required for achieving a spatial overlap between the laser and the backward energetic electrons. At peak laser intensity of 1.4×1020 W/cm2, backward-emitted photons (energies above 100 keV and 10° divergence angle) account for 2×10−5 of the incident laser energy. This conversion efficiency is three times higher than that for similarly selected forward-emitted photons. The source size of the backward photons (5 μm) is three times smaller than the source size of the forward photons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold L-shell emission spectroscopy as a temperature diagnostic in laser-driven experiments

Measurements of plasma conditions within gold hohlraums are challenging but provide important information about hohlraum energy transport. To date, there are no reliable passive diagnostic approaches that produce information about the hohlraum plasma conditions. Gold L-shell emission spectroscopy is a promising method to measure the electron temperature in multi-keV gold hohlraum plasmas. In this study, we compare time-resolved measurements of gold L-shell spectra against a more conventional electron temperature-sensitive diagnostic, K-shell emission from zinc, a mid-Z dopant. The Au L-shell and Zn K-shell spectra are taken simultaneously. The analysis of both sets of data exhibits good agreement with a singular rad-hydro model, suggesting a similar evolution in the mean electron temperature of the hohlraum plasma. These findings support the use of L-shell spectroscopy of gold as a method to study gold plasma conditions.

Emission spectroscopy↗

A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of 100 Mo. It will operate at ~10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of 100 Mo-enriched Li 2 MoO 4 crystals, facing thin Ge-wafer-based bolometric light detectors. In the CUPID design, the detector structure is novel and needs to be validated. In particular, the CUORE cryostat presents a high level of mechanical vibrations due to the use of pulse tubes and the effect of vibrations on the detector performance must be investigated. In this paper we report the first test of the CUPID-design bolometric light detectors with NTD-Ge sensors in a dilution refrigerator equipped with a pulse tube in an above-ground lab. Light detectors are characterized in terms of sensitivity, energy resolution, pulse time constants, and noise power spectrum. Despite the challenging noisy environment due to pulse-tube-induced vibrations, we demonstrate that all the four tested light detectors comply with the CUPID goal in terms of intrinsic energy resolution of 100 eV RMS baseline noise. Indeed, we have measured 70–90 eV RMS for the four devices, which show an excellent reproducibility. We have also obtained high energy resolutions at the 356 keV line from a 133 Ba source, as good as Ge semiconductor γ detectors in this energy range.

47 OTHER INSTRUMENTATION↗

Exploring high-intensity laser-driven secondary sources via high-order spectral pulse shaping for high-energy-density experiments

We present here the results of an investigation that aims to explore the impact of spectral pulse shaping on the generation of high-energy electrons (>1 MeV) and x rays (∼5–9 keV) using a high-intensity (I∼10 21 W/cm 2 ) laser system. The study involved a systematic scan of a broad parameter space in group delay dispersion and third-order dispersion, with variations up to 4 × 10 3 fs −2 and 6 × 10 4 fs −3 , respectively, to identify optimal conditions for enhancing secondary source yields. Several spectral phase conditions were found to significantly enhance the generation of hot electrons and x rays by amounts reaching up to 50% relative to the transform-limited pulse. The experiment, conducted at the Scarlet laser facility (800 nm, 5 J, 30 fs) at the Ohio State University, highlights the potential of spectral pulse shaping as a powerful tool for tuning secondary laser-driven sources. These findings are particularly relevant for advancing brighter x-ray and electron probes for high-energy-density science.

Physics - Plasma physics↗

First use of an InSb crystal for x-ray imaging spectroscopy of highly ionized tungsten in the Wendelstein 7-X stellarator

Advances in time and space resolved measurements of highly charged states of tungsten (W) through x-ray imaging spectroscopy have enabled investigation of impurity transport in the Wendelstein 7-X (W7-X) stellarator. The high-resolution x-ray imaging spectrometer (HR-XIS) system on W7-X utilizes the Bragg diffraction properties of a set of multiple crystals to measure a range of impurity emission lines within sections of the 1–7 Å wavelength range, including transitions of W. A new indium–antimonide crystal has been installed on the HR-XIS system to allow viewing of the 5.5–6.2 Å region focusing on emissions of W. Consequently, many bright W emission lines from W 40+ to W 47+ were observed in this wavelength range, both in plasmas with injected W and in those with only intrinsic W impurity sources, showing the high sensitivity of the diagnostic. Three W 46+ emissions correspond in wavelength and intensity with calculated photon emissivity coefficients and can be exploited for W transport and concentration applications in plasmas with T e ≳ 2.1 keV. Here, an estimate of the core W density behavior in two separate turbulence-reduced ‘high-performance’ (HP) discharges on W7-X is done using the 5.6893 Å W 46+ line. The n W behavior in HP scenarios can be explained by previous experimental results and neoclassical predictions.

XICS↗

Harmonic generation in a terawatt x-ray free-electron laser

Abstract Terawatt x-ray free-electron lasers (XFELs) represent the frontier in further development of x-ray sources and require high current densities with strong transverse focusing. In this paper, we investigate the implications/potentialities of TW XFELs on the generation of harmonics at still shorter wavelengths and higher photon energies. The simulations indicate that significant power levels are possible at high harmonics of the XFEL resonance and that these XFELs can be an important coherent source of hard x-rays through the gamma ray spectrum. For this purpose, we use the MINERVA simulation code which self-consistently includes harmonic generation. Both helical and planar undulators are discussed in which the fundamental is at 1.5 Å and study the associated harmonic generation. While tapered undulators are needed to reach TW powers at the fundamental, the taper does not enhance the harmonics because the taper must start before saturation of the fundamental, while the harmonics saturate before this point is reached. Nevertheless, the harmonics reach substantial powers. Simulations indicate that, for the parameters under consideration, peak powers of the order of 180 MW are possible at the fifth harmonic with a photon energy of about 41 keV and still high harmonics may also be generated at substantial powers. Such high harmonic powers are certain to enable a host of enhanced applications.

Physics↗

XRISM/Resolve view of Abell 2319: Turbulence, sloshing, and ICM dynamics

Here, we present results from XRISM/Resolve observations of the core of the galaxy cluster Abell 2319, focusing on its kinematic properties. The intracluster medium (ICM) exhibits temperatures of approximately 8 keV across the core, with a prominent cold front and a high-temperature region (⁠~11 keV) in the north-west. The average gas velocity in the 3' x 4' region around the brightest cluster galaxy (BCG) covered by two Resolve pointings is consistent with that of the BCG to within 40 km s -1 ⁠ and we found modest average velocity dispersion of 230–250 km s -1 ⁠. On the other hand, spatially resolved spectroscopy reveals interesting variations. A blueshift of up to ~230 km s -1 ⁠ is observed around the east edge of the cold front, where the gas with the lowest specific entropy is found. The region further south inside the cold front shows only a small velocity difference from the BCG; however, its velocity dispersion is enhanced to ~400 km s -1 ⁠, implying the development of turbulence. These characteristics indicate that we are observing sloshing motion with some inclination angle following BCG and that gas phases with different specific entropy participate in sloshing with their own velocities, as expected from simulations. No significant evidence for a high-redshift ICM component associated with the subcluster Abell 2319B was found in the region covered by the current Resolve pointings. These results highlight the importance of sloshing and turbulence in shaping the internal structure of Abell 2319. Further deep observations are necessary to better understand the mixing and turbulent processes within the cluster.

Astronomy and AstroPhysics↗

Improving CdMnTe Detector Performance by Adding 2% of Selenium

About 2% of selenium was added to CdMnTe (CMT) to reveal the role of selenium in CMT material used as a gamma-ray detector. The average etch-pit density (EPD) in a typical 2-in CdMnTeSe (CMTS) wafer was measured to be about 8.3×10 3 cm –2 except for the edge regions, and the radial nonuniformity of the bandgap along the wafer was about 2-meV. The typical mobility-lifetime product of electrons and holes was evaluated to be 3.06×10 –3 cm 2 /V and 3.1×10 –4 cm 2 /V, respectively. The energy resolution of the 122-keV photo-peak for a Co-57 radioactive source with a planar CMTS detector was 5.2%, demonstrating a positive effect associated with adding dilute amounts of Se to CMT. Finally, the enhanced detector performance in a planar CMTS detector is attributed to an improved value of hole mobility-lifetime product in CMTS, which mitigates the adverse hole tailing effect found in CdZnTe (CZT) and CMT detectors.

47 OTHER INSTRUMENTATION↗

Performance Study of Virtual Frisch Grid CdZnTeSe Detectors

Nuclear detectors for x-ray and gamma-ray spectroscopy and imaging are a vital tool in many homeland security, medical imaging, astrophysics and other applications. Most of these applications require room-temperature operation due to the operational constraints imposed by a cryogenic cooling system. CdZnTe (CZT) has been the main material with the desired detection properties, and CZT crystals have been used commercially for three decades. However, CdZnTe still suffers from long-standing issues of high densities of performance-limiting intrinsic defects such as Te inclusions and networks of dislocation walls (sub-grain boundaries). A recently invented new quaternary material CdZnTeSe showed excellent material properties for radiation detection. The material was found to be free from dislocation networks, possess reduced Te inclusions, and have better compositional homogeneity. Virtual Frisch grid detectors were fabricated from crystals taken from a CdZnTeSe ingot that was grown by the traveling heater method. The detectors were fabricated from an as-grown ingot, bypassing the post-growth annealing process commonly practiced for industrial-grade CZT. The performances of the detectors were studied with different Frisch grid lengths using an amplifier shaping time ranging from 1–6 µs. The detectors showed high-quality spectroscopic performance with an as-measured energy resolution of ~1.1% at 662 keV for an optimum Frisch grid length of 3 mm. The charge collection was observed to enhance for longer Frisch grids.

47 OTHER INSTRUMENTATION↗

Multiwavelength Afterglow Analysis of GRB 221009A: Unveiling the Evolution of a Cooling Break in a Wind-like Medium

Gamma-ray bursts (GRBs) are the most energetic explosions in the Universe, and their afterglow emission provides an opportunity to probe the physics of relativistic shock waves in an extreme environment. Several key pieces for completing the picture of GRB afterglow physics are still missing, including jet properties, the emission mechanism, and particle acceleration. Here, we present a study of the afterglow emission of GRB 221009A, the most energetic GRB ever observed. Using optical, X-ray, and gamma-ray data up to approximately 2 days after the trigger, we trace the evolution of the multiwavelength spectrum and the physical parameters behind the emission process. The broadband spectrum is consistent with the synchrotron emission emitted by relativistic electrons with its index of p = 2.29 ± 0.02. We identify a break energy at keV and an exponential cutoff at GeV in the observed multiwavelength spectrum. The break energy increases in time from $16.0^{+7.1}_{-4.9}$ keV at 0.65 days to $46.8^{+25.0}_{-15.5}$ keV at 1.68 days, favoring a stellar-wind-like profile of the circumburst medium with k = 2.4 ± 0.1 as in ρ(r) ∝ r -k . The high-energy attenuation at around 0.4 to 4 GeV is attributed to the maximum of the particle acceleration in the relativistic shock wave. This study confirms that the synchrotron process can explain the multiwavelength afterglow emission and its evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Bulk Motions in the Black Hole Jet Sheath as a Candidate for the Comptonizing Corona

Abstract Using two-dimensional general relativistic resistive magnetohydrodynamic simulations, we investigate the properties of the sheath separating the black hole jet from the surrounding medium. We find that the electromagnetic power flowing through the jet sheath is comparable to the overall accretion power of the black hole. The sheath is an important site of energy dissipation as revealed by the copious appearance of reconnection layers and plasmoid chains. About 20% of the sheath power is dissipated between 2 and 10 gravitational radii. The plasma in the dissipative sheath moves along a nearly paraboloidal surface with transrelativistic bulk motions dominated by the radial component, whose dimensionless 4-velocity is ∼1.2 ± 0.5. In the frame moving with the mean (radially dependent) velocity, the distribution of stochastic bulk motions resembles a Maxwellian with an “effective bulk temperature” of ∼100 keV. Scaling the global simulation to Cygnus X-1 parameters gives a rough estimate of the Thomson optical depth across the jet sheath, ∼0.01–0.1, and it may increase in future magnetohydrodynamic simulations with self-consistent radiative losses. These properties suggest that the dissipative jet sheath may be a viable “coronal” region, capable of upscattering seed soft photons into a hard, nonthermal tail, as seen during the hard states of X-ray binaries and active galactic nuclei.

Sridhar, Navin (ORCID:0000000255199550)↗

The XRISM/Resolve View of the Fe K Region of Cyg X-3

The X-ray binary system Cygnus X-3 (4U 2030+40, V1521 Cyg) is luminous but enigmatic owing to the high intervening absorption. High-resolution X-ray spectroscopy uniquely probes the dynamics of the photoionized gas in the system. In this Letter, we report on an observation of Cyg X-3 with the XRISM/Resolve spectrometer, which provides unprecedented spectral resolution and sensitivity in the 2–10 keV band. We detect multiple kinematic and ionization components in absorption and emission whose superposition leads to complex line profiles, including strong P Cygni profiles on resonance lines. The prominent Fe xxv Heα and Fe xxvi Lyα emission complexes are clearly resolved into their characteristic fine-structure transitions. Self-consistent photoionization modeling allows us to disentangle the absorption and emission components and measure the Doppler velocity of these components as a function of binary orbital phase. We find a significantly higher velocity amplitude for the emission lines than for the absorption lines. The absorption lines generally appear blueshifted by ∼−500–600 km s −1 . We show that the wind decomposes naturally into a relatively smooth and large-scale component, perhaps associated with the background wind itself, plus a turbulent, denser structure located close to the compact object in its orbit.

Audard, Marc (ORCID:000000034721034X)↗

A Leptonic Model for Neutrino Emission From Active Galactic Nuclei

It is often stated that the observation of high-energy neutrinos from an astrophysical source would constitute a smoking gun for the acceleration of hadronic cosmic rays. Here, we point out that there exists a purely leptonic mechanism to produce TeV-scale neutrinos in astrophysical environments. In particular, very high-energy synchrotron photons can scatter with X-rays, exceeding the threshold for muon-antimuon pair production. When these muons decay, they produce neutrinos without any cosmic-ray protons or nuclei being involved. In order for this mechanism to be efficient, the source in question must produce very high-energy photons which interact in an environment that is dominated by keV-scale radiation. As an example, we consider the active galaxy NGC 1068, which IceCube has recently detected as a source of TeV-scale neutrinos. We find that the neutrino emission observed from this source could potentially be generated through muon pair production for reasonable choices of physical parameters.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Codoping method for modifying the scintillation and optical properties of garnet-type scintillators

A method of tailoring the properties of garnet-type scintillators to meet the particular needs of different applications is described. More particularly, codoping scintillators, such as Gd 3 Ga 3 Al 2 O 12 , Gd 3 Ga 2 Al 3 O 12 , or other rare earth gallium aluminum garnets, with different ions can modify the scintillation light yield, decay time, rise time, energy resolution, proportionality, and/or sensitivity to light exposure. Also provided are the codoped garnet-type scintillators themselves, radiation detectors and related devices comprising the codoped garnet-type scintillators, and methods of using the radiation detectors to detect gamma rays, X-rays, cosmic rays, and particles having an energy of 1 keV or greater.

Tyagi, Mohit↗