Search NASA⌕ Search

SEARCH · Search NASA

Results for “Krypton”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Initial results from safety testing of US AGR-2 irradiation test fuel

Two cylindrical compacts containing tristructural isotropic (TRISO)-coated particles with kernels that contained a mixture of uranium carbide and uranium oxide (UCO) and two compacts with UO 2 -kernel TRISO particles have undergone 1600°C safety testing. These compacts were irradiated in the US Advanced Gas Reactor Fuel Development and Qualification Program's second irradiation test (AGR-2). The time-dependent releases of several radioisotopes ( 110m Ag, 134 Cs, 137 Cs, 154 Eu, 155 Eu, 90 Sr, and 85 Kr) were monitored while heating the fuel specimens to 1600°C in flowing helium for 300 h. The UCO compacts behaved similarly to previously reported 1600°C-safety-tested UCO compacts from the AGR-1 irradiation. No failed TRISO or failed SiC were detected (based on krypton and cesium release), and cesium release through intact SiC was very low. Release behavior of silver, europium, and strontium appeared to be dominated by inventory originally released through intact coating layers during irradiation but retained in the compact matrix until it was released during safety testing. Both UO 2 compacts exhibited cesium release from multiple particles whose SiC failed during the safety test. Europium and strontium release from these two UO 2 compacts appeared to be dominated by release from the particles with failed SiC. Silver release was characteristically like the release from the UCO compacts in that an initial release of the majority of silver trapped in the matrix occurred during ramping to 1600°C. However, additional silver release was observed later in the safety testing due to the UO 2 TRISO with failed SiC. Failure of the SiC layer in the UO 2 fuel appears to have been dominated by CO corrosion, as opposed to the palladium degradation observed in AGR-1 UCO fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Key results from irradiation and post-irradiation examination of AGR-1 UCO TRISO fuel

The AGR-1 irradiation experiment was performed as the first test of tristructural isotropic (TRISO) fuel in the US Advanced Gas Reactor Fuel Development and Qualification Program. The experiment consisted of 72 right cylinder fuel compacts containing approximately 3 × 105 coated fuel particles with uranium oxide/uranium carbide (UCO) fuel kernels. The fuel was irradiated in the Advanced Test Reactor for a total of 620 effective full power days. Fuel burnup ranged from 11.3 to 19.6% fissions per initial metal atom and time-average, volume-average irradiation temperatures of the individual compacts ranged from 955 to 1136 °C. This paper focuses on key results from the irradiation and post-irradiation examination, which revealed a robust fuel with excellent performance characteristics under the conditions tested and have significantly improved the understanding of UCO coated particle fuel irradiation behavior. The fuel exhibited zero TRISO coating failures (failure of all three dense coating layers) during irradiation and post-irradiation safety testing at temperatures up to 1700 °C. Advanced PIE methods have allowed particles with SiC coating failure that were discovered to be present in a very-low population to be isolated and meticulously examined, which has elucidated the specific causes of SiC failure in these specimens. The level of fission product release from the fuel during irradiation and post-irradiation safety testing has been studied in detail. Results indicated very low release of krypton and cesium through intact SiC and modest release of europium and strontium, while also confirming the potential for significant silver release through the coatings depending on irradiation conditions. Focused study of fission products within the coating layers of irradiated particles down to nanometer length scales has provided new insights into fission product transport through the coating layers and the role various fission products may have on coating integrity. The broader implications of these results and the application of lessons learned from AGR-1 to fuel fabrication and post-irradiation examination for subsequent fuel irradiation experiments as part of the US fuel program are also discussed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nonlinear ionization dynamics of hot dense plasma observed in a laser-plasma amplifier

Understanding the behaviour of matter under conditions of extreme temperature, pressure, density and electromagnetic fields has profound effects on our understanding of cosmologic objects and the formation of the universe. Lacking direct access to such objects, our interpretation of observed data mainly relies on theoretical models. However, such models, which need to encompass nuclear physics, atomic physics and plasma physics over a huge dynamic range in the dimensions of energy and time, can only provide reliable information if we can benchmark them to experiments under well-defined laboratory conditions. Due to the plethora of effects occurring in this kind of highly excited matter, characterizing isolated dynamics or obtaining direct insight remains challenging. High-density plasmas are turbulent and opaque for radiation below the plasma frequency and allow only near-surface insight into ionization processes with visible wavelengths. Here, the output of a high-harmonic seeded laser-plasma amplifier using eight-fold ionized krypton as the gain medium operating at a 32.8 nm wavelength is ptychographically imaged. A complex-valued wavefront is observed in the extreme ultraviolet (XUV) beam with high resolution. Ab initio spatio-temporal Maxwell–Bloch simulations show excellent agreement with the experimental observations, revealing overionization of krypton in the plasma channel due to nonlinear laser-plasma interactions, successfully validating this four-dimensional multiscale model. This constitutes the first experimental observation of the laser ion abundance reshaping a laser-plasma amplifier. The presented approach shows the possibility of directly modelling light-plasma interactions in extreme conditions, such as those present during the early times of the universe, with direct experimental verification.

36 MATERIALS SCIENCE↗

Analysis of 85Kr: a comparison at the 10-14 level using micro-liter samples

The isotopic abundance of 85Kr in the atmosphere, currently at the level of 10211, has increased by orders of magnitude since the dawn of nuclear age. With a half-life of 10.76 years, 85Kr is of great interest as tracers for environmental samples such as air, groundwater and ice. Atom Trap Trace Analysis (ATTA) is an emerging method for the analysis of rare krypton isotopes at isotopic abundance levels as low as 10214 using krypton gas samples of a few micro-liters. Both the reliability and reproducibility of the method are examined in the present study by an inter-comparison among different instruments. The 85Kr/Kr ratios of 12 samples, in the range of 10213 to 10210, are measured independently in three laboratories: a low-level counting laboratory in Bern, Switzerland, and two ATTA laboratories, one in Hefei, China, and the other in Argonne, USA. The results are in agreement at the precision level of 5%.

MASS SPECTROMETRY↗

Noble gas excimer scintillation following neutron capture in boron thin films

Far-ultraviolet scintillation signals have been measured in heavy noble gases (argon, krypton, xenon) following boron-neutron capture ({sup 10}B(n,α){sup 7}Li) in {sup 10}B thin films. The observed scintillation yields are comparable to the yields from some liquid and solid neutron scintillators. At noble gas pressures of 107 kPa, the number of photons produced per neutron absorbed following irradiation of a 1200 nm thick {sup 10}B film was 14 000 for xenon, 11 000 for krypton, and 6000 for argon. The absolute scintillation yields from the experimental configuration were calculated using data from (1) experimental irradiations, (2) thin-film characterizations, (3) photomultiplier tube calibrations, and (4) photon collection modeling. Both the boron films and the photomultiplier tube were characterized at the National Institute of Standards and Technology. Monte Carlo modeling of the reaction cell provided estimates of the photon collection efficiency and the transport behavior of {sup 10}B(n,α){sup 7}Li reaction products escaping the thin films. Scintillation yields increased with gas pressure due to increased ionization and excitation densities of the gases from the {sup 10}B(n,α){sup 7}Li reaction products, increased frequency of three-body, excimer-forming collisions, and reduced photon emission volumes (i.e., larger solid angle) at higher pressures. Yields decreased for thicker {sup 10}B thin films due to higher average energy loss of the {sup 10}B(n,α){sup 7}Li reaction products escaping the films. The relative standard uncertainties in the measurements were determined to lie between 14% and 16%. The observed scintillation signal demonstrates that noble gas excimer scintillation is promising for use in practical neutron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-LTE analysis of high energy density Kr plasmas on Z and NIF

We report that multi-keV X-ray radiation sources have a wide range of applications, from biomedical studies and research on thermonuclear fusion to materials science and astrophysics. The refurbished Z pulsed power machine at the Sandia National Laboratories produces intense multi-keV X-rays from argon Z-pinches, but for a krypton Z-pinch, the yield decreases much faster with atomic number Z A than similar sources on the National Ignition Facility (NIF) laser at the Lawrence Livermore National Laboratory. To investigate whether fundamental energy deposition differences between pulsed power and lasers could account for the yield differences, we consider the Kr plasma on the two machines. The analysis assumes the plasma not in local thermodynamic equilibrium, with a detailed coupling between the hydrodynamics, the radiation field, and the ionization physics. While for the plasma parameters of interest the details of krypton’s M-shell are not crucial, both the L-shell and the K-shell must be modeled in reasonable detail, including the state-specific dielectronic recombination processes that significantly affect Kr’s ionization balance and the resulting X-ray spectrum. We present a detailed description of the atomic model, provide synthetic K- and L-shell spectra, and compare these with the available experimental data from the Z-machine and from NIF to show that the K-shell yield behavior versus Z A is indeed related to the energy input characteristics. In conclusion, this work aims at understanding the probable causes that might explain the differences in the X-ray conversion efficiencies of several radiation sources on Z and

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Staged Z-pinch modeling of high and low atomic number liners compressing deuterium targets using parameters of the Z pulsed power facility

The staged Z-pinch is a potentially transformative magneto-inertial fusion energy concept where a high atomic number liner implodes on a deuterium or deuterium-tritium target using multi-MA pulsed current. Over the past several years, this concept was studied experimentally on 1 MA facilities with argon or krypton gas puffs compressing a magnetized deuterium target. Consistent thermonuclear neutron yield of 1010 per shot was measured with krypton liners. In this paper, we investigate the fusion performance of deuterium targets of varying density undergoing compression with low (beryllium) and high atomic number liners (silver, tantalum) using parameters of the Z pulsed power facility. Silver and tantalum liners create strong shocks that preheat the target plasma above 100 eV and pile up liner material at the liner-target interface. The increased mass density at the interface creates strong ram pressure just before the pinch stagnation time. The target plasma is heated to 2–4 keV, in contrast to the < 0.5 kV temperature calculated for the beryllium case. The high atomic number liners produce neutron yield orders of magnitude higher than the yield from the low atomic number liner.

Ruskov, E. (ORCID:0000000336724580)↗

Two-photon absorption laser induced fluorescence measurements of absolute neutral deuterium density, temperature, and bulk flow in Proto-MPEX

Neutral particle control is critical for fusion fueling and confinement. Neutral diagnostics for fusion-relevant plasmas are commonly restricted to line-integrated or ex situ methods. A non-perturbative, two-photon absorption laser induced fluorescence (TALIF) diagnostic is implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to probe neutral atomic deuterium in a fusion-relevant plasma at 1 cm intervals along the radius of the vacuum vessel. The diagnostic is situated ~20 m from the vacuum vessel, and a signal is collected along the laser injection axis, requiring only one line-of-sight. TALIF measurements are absolutely calibrated using xenon and krypton. Absolute atomic densities derived from xenon calibration are compared to absolute atomic densities derived from krypton calibration. In this work, preliminary measurements of absolute atomic deuterium density, temperature, and local bulk flow dependence on radial location and input power in Proto-MPEX are presented. Neutral atomic deuterium velocity distribution functions are measured throughout a one-second plasma pulse with a time resolution of 250 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Strength, deformation, and the fcc–hcp phase transition in condensed Kr and Xe to the 100 GPa pressure range

The rare gas solids exhibit systematic differences in crystal structure, phase transition conditions, bond strength, and other physical properties. The physical properties of heavy rare gas solids krypton and xenon are modified by the martensitic phase transition from face-centered cubic to hexagonal close packed structure over a broad pressure range. Crystal structure, strength, and plastic deformation of krypton and xenon have been investigated at 300 K using compression in the diamond-anvil cell with synchrotron angle-dispersive x-ray diffraction and complementary ruby fluorescence spectroscopy for Xe. Stacking faults indicative of the fcc–hcp phase transition are observed at pressures at and above 1.23 ± 0.05 and 1.9 ± 0.6 GPa in Kr and Xe, respectively. The transition remains incomplete in both solids to pressures greater than 100 GPa. Strength determined from stress measurements in Pt and ruby standards at pressures up to 111 GPa and complemented by observations of strain and texture measurements obtained by x-ray diffraction in the radial geometry to 100 GPa indicates similar or higher strength than Ar at all conditions, with significant stiffening at 15–20 GPa. Radial diffraction data reveal the persistence of broad highly textured fcc diffraction lines to 101 GPa in Xe, suggesting that the axial measurements may underestimate the metastable persistence of the fcc phase due to biased sampling of hcp crystallites resulting from preferred crystallite orientation. Kr and Xe are compared with He, Ne, and Ar for a systematic understanding of physical properties and phase equilibria of rare gas solids.

Compressive stress↗

Calibration of the NEXT-White detector using 83m Kr decays

We report the NEXT-White (NEW) detector is currently the largest radio-pure high-pressure xenon gas time projection chamber with electroluminescent readout in the world. It has been operating at Laboratorio Subterraneo de Canfranc (LSC) since October 2016. This paper describes the calibrations performed using 83m Kr decays during a long run taken from March to November 2017 (Run II). Krypton calibrations are used to correct for the finite drift-electron lifetime as well as for the dependence of the measured energy on the event transverse position which is caused by variations in solid angle coverage both for direct and reflected light and edge effects. After producing calibration maps to correct for both effects we measure an excellent energy resolution for 41.5 keV point-like deposits of (4.553 +/- 0.010 (stat.) ± 0.324 (sys.)) % FWHM in the full chamber and (3.804 ± 0.013 (stat.) ± 0.112 (sys.)) % FWHM in a restricted fiducial volume. Laslty, using naive 1/$ \sqrt{E} $ scaling, these values translate into resolutions of (0.5916 ± 0.0014 (stat.) ± 0.0421 (sys.)) % FWHM and (0.4943 ± 0.0017 (stat.) +/- 0.0146 (sys.)) % FWHM at the Qᵦᵦ energy of xenon double beta decay (2458 keV), well within range of our target value of 1%.

47 OTHER INSTRUMENTATION↗

Direct laser ion acceleration and above-threshold ionization at intensities from 10 21 W/cm 2 to 3 × 10 23 W/cm 2

Calculations on the dynamics of ions and electrons in near-infrared laser fields at intensities up to 3 × 10 23 W/cm 2 are presented here. We explore the acceleration of ions in a laser focus by conservation of canonical momentum during ionization events and by the ponderomotive force in the f/1 focal geometry required to reach such intensity. At intensities exceeding 10 23 W/cm 2 , highly charged ions are expelled from the laser focus before they can interact with the laser pulse at peak intensity, decreasing the predicted ionization yields of deeply bound states. We consider the interaction of a tightly focused, f/1 laser pulse with krypton at an intensity of 3 × 10 23 W /cm 2 and a pulse duration of 140 fs.We find that the ions and electrons are accelerated to energies in excess of 2 MeV/nucleon and 1.4 GeV, respectively. Ponderomotive expulsion of the parent ions decreases the total number of ultrarelativistic above-threshold ionization electrons produced by tunneling ionization from the K-shell states of krypton but does not change their energy spectrum.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of fission product release predictions using PARFUME with results from the AGR-1 safety tests

Safety tests were conducted on fourteen fuel compacts from AGR-1, the first irradiation experiment of the Advanced Gas Reactor (AGR) Fuel Development and Qualification program, at temperatures ranging from 1600 to 1800°C to determine fission product release at temperatures that bound reactor accident conditions. The PARFUME (PARticle FUel ModEl) code was used to predict the release of fission products silver, cesium, strontium, and krypton from fuel compacts containing tristructural isotropic (TRISO) coated particles during the safety tests, and the predicted values were compared with experimental results. Preliminary comparisons between PARFUME predictions and post-irradiation examination (PIE) results of the safety tests show different trends in the prediction of the fractional release depending on the species, and it leads to different conclusions regarding the diffusivities used in the modeling of fission product transport in TRISO-coated particles: • For silver, the diffusivity in silicon carbide (SiC) might be over-estimated by a factor of at least 102 to 103 at 1600°C and 1700°C, and at least 10 to 102 at 1800°C. The diffusivity of silver in uranium oxy-carbide (UCO) might also be over-estimated, but the available data are insufficient to allow definitive conclusions to be drawn. • For cesium, the diffusivity in UCO might be over-estimated by a factor of at least 102 to 103 at 1600°C, 105 at 1700°C, and 103 at 1800°C. The diffusivity of cesium in SiC might also over-estimated, by a factor of 10 at 1600°C and 103 at 1700°C, based upon the comparisons between calculated and measured release fractions from intact particles. There is no available estimate at 1800°C since all the compacts heated up at 1800°C contain particles with failed SiC layers whose release dominates the release from intact particles. • For strontium, the diffusivity in SiC might be over-estimated by a factor of 10 to 102 at 1600 and 1700°C, and 102 to 103 at 1800°C. These values might be somewhat over-estimated because the strontium retention during irradiation cannot be assessed a priori, which affects the magnitude of the calculated release during safety testing. The diffusivity of strontium in UCO cannot be derived from these heating tests, but it is assumed to be modeled correctly using the IAEA recommended value for kernel diffusivity. • For krypton, there is no reliable release data for compacts heated up at 1600°C, which includes all the compacts containing only intact particles. At 1700 and 1800°C, comparisons show an over-prediction of the release from compacts containing particles with failed SiC by 1 to 1.5 orders of magnitude. The available data from these heating tests do not allow to determine which of the TRISO-coating’s layers diffusivities are under or over-estimated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Mechanisms of Retention and Transport of Fission Products in Virgin and Irradiated Nuclear Graphite

To fulfill the design and licensing requirements for advanced reactors, the U.S. Department of Energy (DOE) is specifically interested in targeted research to quantify the mechanisms of fission product transport and retention in graphitic grades that will likely be used in next-generation very/high temperature reactors, fluoride salt-cooled high temperature reactors and molten salt reactors. We have examined an integrated experimental-computational approach to determine the diffusivities of selected fission products – ruthenium (Ru) and silver (Ag) in five nuclear graphite grades – POCO AXF-5Q, POCO ZXF-5Q, PCEA, IG110, and NBG-18. Experimental investigation for diffusion of other fission products (iodine, cesium, and krypton) in graphite could not be carried out due to extreme evaporation due to high vapor pressure, despite several attempts incorporating various experimental schemes. Experimental investigation with irradiated graphite could not be carried out because necessary approval to transport irradiated graphite could not be obtained due to procedural reasons at ORNL and national policy change in UK. An effort was made to “produce” by ion sputtering, but it was discontinued because the outcome did not adequately represent irradiated graphite. Thin film and “cup-and-cap” methods were employed to deposit fission products, diffusion annealed were carried out in an argon atmosphere, and concentration profiles were determined by dynamic secondary ion mass spectroscopy depth profiling technique. Regardless of graphite type, anomalous diffusion behavior of Ru (i.e., lower than expected based on Arrhenius temperature dependence) at an intermediate temperature, around 600 to 700 °C, was observed. Diffusion behavior of silver on the other hand agreed well to the Arrhenius temperature dependence although the excessive evaporation of silver hampered the accurate determination of diffusivities at temperature higher than 900 °C. In general, silver was observed to diffuse faster than Ru in the temperature range compared from 500 to 900 °C, had consistently had higher pre-exponential factor corresponding to higher jump frequency. To understand the abnormal diffusional behavior of Ru in graphite in intermediate temperature range, a detailed microstructural analysis was carried out. Clustering of Ru into particles on the surface of graphite was observed around 700 °C corresponding to de-wetting and spheroidization. This change would influence the boundary condition of diffusion, although features of clustering was much smaller (<1 mm) than the SIMS raster size (120 x 120 mm). Raman spectroscopy also demonstrated that Raman peak intensity for Ru decreased significantly for samples annealed higher than 700 °C and presence of Ru in graphite altered the crystallinity of graphite. To further elucidate the abnormal diffusion behavior observed in intermediate temperature investigated, the vibrational properties of graphene, bilayer graphene and Kr atoms in bilayer graphene were investigated with molecular dynamics. Krypton, which is a fission product, was introduced between a bilayer graphene system to evaluate (i) whether the phonon dispersion curves change with high temperature in bilayer graphene (ii) whether the addition of Kr atoms between the bilayer introduces any significant change in the vibrational properties, and (iii) whether any change in the vibrational properties can be correlated to the diffusive behavior of Kr atoms. The results show that the Kr atoms indeed exhibit an anomalous diffusive behavior at 550°C. Phonon analysis shows that a few phonon frequencies are enhanced as much as 20 to 30 % with the addition of just 0.2 at.% Kr. So, this may explain the unexpected self-diffusivity of fission products.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Operation Experience with DC Photoemission Guns at Jefferson Lab

The JLab IR FEL injector is driven by a DC photoemission electron gun based on GaAs photocathodes. Since the FEL commissioning in 1998, the DC gun has been rebuilt several times for improved performance and/or for repairs. After demonstrating 9 mA CW and over 7000 Coulombs at 350kV for three consecutive years, the gun was rebuilt in 2008 due to a punctured insulator. Since then, the gun has been operating at 325V (lower voltage due to field emission) and has delivered beam at 65 pC bunch charge for VUV FEL operations, and 135pC for IR FEL operations at beam currents up to 4 mA CW. In February 2011, a copy of that gun was tested in the Gun Test Stand with a partially conductive insulator from Wesgo/Morgan to study bulk conductivity as charge drain for preventing insulator puncture by field emission. Close to 300 hours of high voltage testing showed that processing of field emission with partial pressure of Krypton gas is very effective. The gun held 500kV over 8 hours with 1E-4 Torr of Krypton. However, the gun could not hold more than 440kV under vacuum conditions, at which set point the insulator suffered a puncture. Various observations of Kr processing behavior and voltage-induced gas desorption will be presented. Financial support was provided by the Office of Naval Research, the Army Night Vision Laboratory, the Air Force Research Laboratory, the Joint Technology Office, the Commonwealth of Virginia, and by the U.S. DOE Basic Energy Sciences under contract No. DE-AC05-060R23177.

Hernandez-Garcia, Carlos↗

Field Emission Studies Toward Improving the Performance of DC High Voltage Photoelectron Guns

Field emission is the main mechanism that prevents DC high voltage photoemission electron guns from operating at the very high bias voltages required to produce low emittance beams. Gas conditioning is shown to eliminate field emission from cathode electrodes used inside DC high voltage photoelectron guns. Measurements and simulation results indicate that gas conditioning eliminates field emission from cathode electrodes via two mechanisms: sputtering and implantation, with the benefits of implantation reversed by heating the electrode. The field emission characteristics of 5 stainless steel electrodes varied significantly upon the initial application of voltage but improved to nearly the same level after helium and krypton gas conditioning, exhibiting less than 10 pA field emission at - 225kV bias voltage with a 50 mm cathode/anode gap, corresponding to a field strength ? 13 MV/m. Field emission could be reduced with either krypton or helium, but there were conditions related to gas choice, voltage and field strength that were more favorable than others. The field emission characteristics of niobium electrodes were compared to those of stainless steel electrodes using a DC high voltage field emission test apparatus. Out of 8 electrodes (6 niobium and 2 stainless steel), the best niobium electrode performed better than the best stainless steel electrodes. Large grain niobium exhibited no measurable field emission (< 10 pA) at 225 kV with 20 mm cathode/anode gap, corresponding to a field strength of 18.7 MV/m. Surface evaluation of all electrodes suggested no correlation between the surface roughness and the field emission current. Removing surface particulate contaminations and protrusions using an effective polishing and cleaning technique helps to prevent field emission. Mechanical polishing using silicon carbide paper and diamond paste is a common method of obtaining a mirror like surface finish on the cathode electrodes. However, it sometimes results rolled-over tips and embedded contamination. A different polishing technique was considered: electropolishing. Three stainless steel cathode electrodes with different initial surface roughness were electropolished by a commercial vendor, and evaluated inside a high voltage test stand. They exhibited less field emission than the diamond paste polished electrodes at the initial application of high voltage; but they were less receptive to ion implantation, which is a beneficial aspect of gas conditioning that serves to increase the work function of the cathode surface. Ultimately, the electropolished electrodes exhibited more field emission than diamond-paste polished electrodes.

Bastaninejad, Mahzad↗

Operation of an electron-bombardment ion source using various gases

An electron-bombardment ion thruster of the SERT 2 type was operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was similar to that obtained previously with mercury. Mass spectrometer data indicated that the xenon contained no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor because the basic thruster designed was optimized for operation with mercury.

Byers, D. C.↗

Electron-bombardment ion source operation using various gases.

Description of a modified flight-type SERT II ion thruster operated with xenon, krypton, argon, neon, nitrogen, helium, and carbon dioxide. The discharge performance with xenon, krypton, and argon was found to be similar to that obtained previously with mercury. Mass spectrometer data indicated that xenon could be operated efficiently with no significant multiple ionization. Restriction of the beam area, with an associated decrease in discharge potential, was necessary to reduce multiple ionization with argon to a negligible level. This modification also resulted in more stable operation of the thruster. Performance with the remaining gases was poor, but some future performance improvements may be realizable.

Byers, D. C.↗

Driving lamps by induction

An electrodeless lamp circuit with a coil surrounding a krypton lamp is driven by an RF input source. A coil surrounding a mercury lamp is tapped across the connection of the input central to the krypton-lamp coil. Each coil is connected in parallel with separate capacitors which form resonant circuits at the input frequency.

Laue, H. H.↗