Search NASA⌕ Search

SEARCH · Search NASA

Results for “LAB”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Boosting Deuteron Polarization in HD Targets: Experience of moving spins between H and D with RF methods during the E06-101 experiment at Jefferson Lab

Solid HDice targets are polarized by bringing the HD crystal to thermal equilibrium at low temperature and high magnetic field, typically 10-20 mK and 15 Tesla, at Jefferson Lab. In this regime, due to its smaller magnetic moment, the resulting polarization for D is always at least three times smaller than for H. The controlled amount of polarizing catalysts, o-H2 and p-D2, used in the process of reaching a frozen-spin state, further limit the maximum achievable D polarization. Nonetheless, H and D polarizations can be transferred from one to the other by connecting the H and D sub-states of the HD system with RF. In a large target, the RF power needed for such transitions is effectively limited by non-uniformities in the RF field. High efficiency transfers can require substantial RF power levels, and a tuned-RF circuit is needed to prevent large temperature excursions of the holding cryostat. In this paper, we compare the advantages and limitations of two different RF transfer methods to increase D polarization, Forbidden Adiabatic and Saturated Forbidden RF Transitions. The experience with the HD targets used during the recently completed E06-101 experiment in Hall-B of Jefferson Lab is discussed.

Wei, Xiangdong↗

An overview of recent nucleon spin structure measurements at Jefferson Lab

Jefferson Lab have made significant contributions to improve our knowledge of the longitudinal spin structure by measuring polarized structure functions, g1 and g2, down to Q2 = 0.02 GeV2. The low Q2 data is especially useful in testing the Chiral Perturbation theory (cPT) calculations. The spin-dependent sum rules and the spin polarizabilities, constructed from the moments of g1 and g2, provide an important tool to study the longitudinal spin structure. We will present an overview of the experimental program to measure these structure functions at Jefferson Lab, and present some recent results on the neutron polarizabilities, proton g1 at low Q2, and proton and neutron d2 measurement. In addition to this, we will discuss the transverse spin structure of the nucleon which can be accessed using chiral-odd transversity distribution (h1), and show some results from measurements done on polarized 3He target in Hall A.

Allada, Kalyan↗

CEBAF at Jefferson Lab

The U.S. and international nuclear physics community uses Jefferson Lab's state-of-the-art Continuous Electron Beam Accelerator Facility or CEBAF to conduct world-class fundamental research. The Lab supports more than 1,250 visiting researchers from more than 200 institutions.

Source record↗

Goats Graze Hills at Berkeley Lab

(July 12, 2018) - Our favorite goats from Goats R Us are spending time in area 2 just above Buildings 55, 60, & 64. We bring goats to the lab each year to aid in efforts around fire prevention and fire safety. They help us manage vegetation and reduce potential wildfire fuels. (Video: Kelly J. Owen / Berkeley Lab)

99 GENERAL AND MISCELLANEOUS↗

Goats on the Move at Berkeley Lab

(July 12, 2018) Our favorite goats from Goats R Us are herded from Area 5 to Area 2 this morning to spend time just above Buildings 55, 60, & 64. We bring goats to the lab each year to aid in efforts around fire prevention and fire safety. They help us manage vegetation and reduce potential wildfire fuels. (Video: Kelly J. Owen / Berkeley Lab)

99 GENERAL AND MISCELLANEOUS↗

MEASUREMENT OF Fn 2 /Fp 2 FROM DEEP INELASTIC ELECTRON SCATTERING OFF A=3 MIRROR NUCLEI AT JEFFERSON LAB

This research is part of the Je?erson Lab MARATHON experiment (MeAsurement of the Fn 2 /Fp 2 , d/u RAtios and A = 3 EMC E?ect in Deep Inelastic Electron Scattering Off the Tritium and Helium MirrOr Nuclei). MARATHON is an experiment on electron deep inelastic scattering off the 3H, 3He mirror nuclei. It has extracted, from the measured deep inelastic scattering cross section ratio o? 3H and 3He, the ratio of the neutron to proton inelastic structure functions Fn 2 /Fp 2 . The extraction has taken advantage of the isospin symmetry of the A = 3 mirror nuclei within a novel technique, which avoids the theoretical uncertainties that are present in the SLAC experiments of the 1970s, which used hydrogen and deuterium targets. The experiment was performed using the upgraded 11 GeV beam of the Jefferson Lab electron accelerator, the Hall A Experimental Facility, and a newly designed cryogenic, high-pressure gas target system containing 3H and 3He cells. Electrons scattered o? the gas targets were detected in the two superconducting, high-resolution magnetic spectrometers of Hall A. The cross section data cover the four-momentum transfer squared range 2.0 < Q2 < 14.0 (GeV/c)2, and the Bjorken x scaling variable range 0.19 < x < 0.83. The experiment also measured, for calibration purposes, electron deep inelastic scattering off hydrogen and deuterium at selected kinematics.

Su, Tong↗

Multipass Beam Breakup Study at Jefferson Lab for the 12 Ge V CEBAF U pgrade

Recirculating linear accelerators (linacs) provide a compact and efficient way of accelerating particle beams to medium and high energies by reusing the same linac for multiple passes. In recirculating linacs, maximum current can be limited by multipass beam breakup (BBU), which occurs when an electron beam interacts with the higher order modes (HOMs) of accelerating cavities during multipass recirculations. The average current of the CEBAF 12 GeV Upgrade accelerator at Jefferson Lab, a 5-pass recirculating linac, may be limited by multipass BBU. This disserta- tion work was performed as part of the 12 GeV Upgrade project at Jefferson Lab to investigate limits on average beam currents from the BBU instability. Exper- imental and simulation studies were carried out, and revealed that the multipass BBU will not be a limiting factor to the average beam current in the 12 GeV Upgrade of the CEBAF accelerator. This dissertation includes the theoretical calculation for longitudinal BBU, which revealed that the maximum current limit from longitudinal BBU is much higher than the transverse one. Therefore, longitudinal BBU will not become a problem, as long as transverse BBU does not cause instability. A cumulative BBU simulation study for a new injector in the 12 GeV accelerator also was conducted. The results showed that the transient behavior of cumulative BBU in the injector is not problematic.

Shin, Ilkyoung↗

Sub-1% Electron Beam Polarimetry in Hall C at Jefferson Lab

The electron beam polarization in experimental Hall C at Jefferson Lab has been measured with a total uncertainty of dP/P<0.7\% at a beam energy of ≈ 1~GeV. This was accomplished using two, high-precision electron beam polarimeters. The first device makes use of M\o ller scattering from atomic electrons polarized in a pure iron foil driven to magnetic saturation. The second uses polarized electron-photon (Compton) scattering from laser light stored in a low gain Fabry-Perot cavity. Data from both devices, as well as a direct comparison of the two will be shown. The polarization data that will be described were taken as part of the Qweak experiment in Hall C, which aimed to measure the polarization to better than 1\%. Future experiments at Jefferson Lab will require knowledge of the polarization to 0.4\% or better. In this talk, I will describe the lessons learned during the Qweak running and discuss prospects for improving the beam polarimetry precision to the 0.4\% level.

Gaskell, David↗

Nucleon Tomography Studies at Jefferson Lab

Protons and neutrons, are the building blocks of atomic nuclei. They constitute over 99 percent of the mass of the matter in the visible universe. A fundamental challenge of modern nuclear physics is to understand the structure of these constituents. The 12 GeV Upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab and the construction of state-of-the-art detector systems make it a unique facility in the world to address this challenge. Electron scattering is a superb experimental tool to study the internal structure of nucleons at differing distance scales, as the resolving power of the probe can be varied. The CEBAF Upgrade was completed in September 2017 and the new generation of experiments has started. These experiments will enable a collaboration of scientists from around the world to perform precise experiments of exclusive processes covering a large range in kinematics to effectively engage in nuclear imaging, revealing hidden aspects of its internal structure, and providing insight into quark confinement forces in the nucleon, one of the greatest mysteries of modern physics. The Generalized Parton Distributions (GPDs) provide the theoretical framework to interpret the experimental data in terms of 3-dimensional imaging. In addition, recent development demonstrated that the GPD formalism enables access to the nucleon's Gravitational Form Factors that encode its mechanical properties. We will focus on the study of the Deeply Virtual Compton Scattering (DVCS), the most effective way to access GPDs. We will review the landscape of both theory and experiment, and discuss the latest results from Jefferson Lab at 6 GeV in comparison with results from other facilities, and present a first look at the new experiments with the 12 GeV Upgrade.

Elouadrhiri, Latifa↗

Precision Electron Beam Polarimetry in Hall C at Jefferson Lab

The electron beam polarization in experimental Hall C at Jefferson Lab is measured using two devices. The Hall-C/Basel M\o ller polarimeter measures the beam polarization via electron-electron scattering and utilizes a novel target system in which a pure iron foil is driven to magnetic saturation (out of plane) using a superconducting solenoid. A Compton polarimeter measures the polarization via electron-photon scattering, where the photons are provided by a high-power, CW laser coupled to a low gain Fabry-Perot cavity. In this case, both the Compton-scattered electrons and backscattered photons provide measurements of the beam polarization. Results from both polarimeters, acquired during the Q-Weak experiment in Hall C, will be presented. In particular, the results of a test in which the M\o ller and Compton polarimeters made interleaving measurements at identical beam currents will be shown. In addition, plans for operation of both devices after completion of the Jefferson Lab 12 GeV Upgrade will also be discussed.

Gaskell, David↗

Nucleon Spin - Results from Jefferson Lab

Over thirty years after the first experiments probed the spin structure of the nucleon, the pace of experimental and theoretical exploration of this subject keeps increasing. During its fifteen-year run with beam energies up to 6 GeV, Jefferson Lab has made many important contributions to this field - from measurements of the inclusive spin structure functions of the proton and the neutron over a wide kinematic range to seminal experiments accessing the three-dimensional nucleon spin structure through Generalized Parton Distributions and Transverse Momentum Dependent structure functions. An even brighter future lies ahead - after the 12 GeV upgrade, Jefferson Lab will completely map the spin-dependent parton distribution functions for all quark flavors in the valence region. In this talk, I will present an overview of this program, with special emphasis on recent and forthcoming results from the 6 GeV run and a glimpse of the future program with 12 GeV.

Kuhn, Sebastian↗

Detailed study of Short Range Correlations at Jefferson Lab

The force which holds the nucleus together has been under intense study for many decades. The nuclear shell model, which plays a central role in these investigations, has been very successful in reproducing low energy measurements, but is insufficient to predict medium energy results. The discrepancy is believed to originate from short range correlations, i.e. overlapping nucleons in the nucleus which briefly create densities close to those in neutron stars. Using an electron beam, these features of the nucleus can be isolated and studied at kinematics where xbj>1. In order to present the new results from Jefferson Lab, we will first highlight what has happened in the field over the last decade. We will also discuss the goals of the future related measurements scheduled to run at Jefferson Lab after the 12 GeV upgrade.

Solvignon, Patricia↗

Rural Hybrid Generation & Microgrids: National Labs are Here to Help

Hear about the tools and technical assistance National Labs can offer to co-ops and other rural utilities seeking to build or enhance hybrid generation projects combining multiple technologies including wind, solar, battery storage, and others resources. These hybrids can deliver additional value by combining complimentary resources and by increasing reliability and resilience, including as part of a microgrid to serve a local load or community. Experienced cooperative and lab experts will share their perspectives on the opportunities there are to make use of their advanced modeling capabilities and expertise to scope, design, and implement these emerging hybrid solutions. Key takeaways for participants will include better understanding of the resilience benefits distributed hybrid systems provide, awareness of National Laboratory assistance programs and resources, tips for successful federal funding applications for these types of projects, and peer-to-peer learning through shared experiences and discussion.

14 SOLAR ENERGY↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Signal Extraction and Simulations for n -> p^0 y y and n -> p+p-e+e- Decays at the Jefferson Lab Eta Factory

The Jefferson Lab eta Factory (JEF) began acquiring data in early 2025. The experiment aims to give insight into the connection between Dark Matter physics models and the Standard Model by investigating rare decay processes of n and n' mesons. Several other physics motivations are also a key factor in the experiment, such as probing C and/or P violation and aspects of chiral perturbation theory. For these purposes, the forward calorimeter of the GlueX experiment in Jefferson Lab was upgraded so that it provides greater positional and energy resolution. Understanding physics-motivated cuts and background removal methods is of great importance to achieving JEF goals. Several methods have been implemented to obtain invariant mass plots for the “golden” channel of interest ¿ ¿ p0¿¿, while channels such as ¿ ¿ p+p-e+e- open a promising window into CP-violating physics. This thesis work shows a sig nificant background reduction in rare decay channels of interest, asymmetry factors comparable to recent experimental measurements, an evaluation on which analysis cuts to use after data acquisition and the likelihood of probing specific rare ¿ decays. Despite background rejection from obstructing decay channels, much remains to do to extract the p0¿¿ final-state. The asymmetry between the pion and lepton planes looks promising for p+p-e+e-; simulations show that the asymmetry is consistent with zero (no instrumental asymmetry), and the next step should include generators that model the physics of the asymmetry. This thesis work may help in the effort of probing CP-violating physics or solving the mysteries between “beyond-Standard Model” and our current understanding of physics.

Oresic, Stjepan [Univ. of Regina, SK (Canada)]↗

Performance of the Pair Spectrometer in Hall D at Jefferson Lab

This article describes the performance of the pair spectrometer installed in experimental Hall D at Jefferson Lab and its successfully operation in multiple experiments with the GlueX detector. The primary purpose of the pair spectrometer is the precise determination of the flux of beam photons incident on the GlueX target, a critical input for physics analyses such as absolute cross-section measurements. The photon energy spectrum is determined by reconstructing electron–positron pairs produced in a thin converter inserted into the photon beam. The spectrometer is integrated into the GlueX trigger system, whose electronics enable continuous real-time monitoring of the photon flux and the recording of e+e- pair candidates for offline analysis. In addition, the pair spectrometer provides a versatile test facility for evaluating calorimeter prototypes using leptons with well-defined energies produced via electromagnetic pair production.

Somov, Alexander [Jefferson Lab]↗