At least 289 records · Page 16

A high-performance lung-inspired ceramic 3D-printed heat exchanger for high-temperature energy-efficient systems

The thermal-to-electric conversion efficiency of next-generation supercritical carbon dioxide and concentrated solar power plants is significantly augmented by operating at temperatures exceeding 1000 °C if durable, compact, high-temperature heat exchangers (HXs) are developed. Whereas metal 3D-printed HXs fail to operate under extreme temperature conditions, ceramic 3D-printed HXs are deemed promising candidates for high-temperature, highly oxidizing environments. Ceramic 3D-printed HXs, however, exhibit a high gas permeability issue through hot and cold separating walls due to an excessive non-volatile photopolymer content utilized. Here, in this work, a novel leak-free lung-inspired ceramic 3D-printed HX employing a highly complex heat transfer topology is introduced for high-temperature energy-efficient systems. The high permeability issue of ceramic 3D-printed HXs is fully eliminated through a uniform zinc-based coating. It was determined that the effective thermal conductivity of the sintered ceramic heat exchangers is affected by the coated layer. The high-temperature thermal and hydraulic characteristics of the lung-inspired ceramic 3D-printed HX are comprehensively examined and compared against a millichannel 3D-printed HX module. Experimental results indicated that the lung-inspired 3D-printed ceramic HX significantly outperforms its millichannel counterpart. The lung-inspired HX shows a volume-based power density of 8.2 MW/m3 at a hot-side inlet air temperature of 700°C, a 71 % improvement compared with that of the millichannel HX. More importantly, the higher thermal duty of the lung-inspired 3D-printed HX is realized at a lower normalized pressure drop penalty of 510 Pa/W, 22 % lower than that of the millichannel ceramic HX. This study accelerates the advancement of high-performance ceramic 3D-printed HXs with complex topologies for high-temperature energy-efficient systems and/or corrosive environments.

42 ENGINEERING↗

Sensitivity analysis of an automated fault detection algorithm for residential air-conditioning systems

The state of the art of fault detection and diagnosis (FDD) for residential air-conditioning systems is expensive and not yet amenable to widespread implementation. FDD for homes can significantly reduce utility costs, and increase the lifespan of the equipment. The cost barriers currently, however, make FDD for homes economically unviable for large scale implementation. In prior work, we offered a solution to reduce FDD costs by proposing an automated fault detection algorithm to serve as a screening step before more expensive FDD tests can be conducted. The algorithm uses only the home thermostat and local weather information to identify thermodynamic parameters and detect high-impact air-conditioning faults, including those that occur during equipment installation. We had tested the algorithm on a single EnergyPlus™ model of a home in Orlando, Florida. The thermodynamic parameter identification process is highly nonconvex involving several local optimal solutions. In this paper we propose a novel method to select the best model for fault detection from among the list of local optimal solutions to make the algorithm more robust to homes of different construction, without which the fault detection process would be infeasible. Another unique contribution of the paper is implementing the solution on real-world data. We also bring the algorithm closer to market by testing it on real-world data. We implement the algorithm on data obtained from experiments conducted by the Florida Solar Energy Center (FSEC) on a laboratory home equipped with a heat pump where faults were intentionally added for a period of seven months. The algorithm successfully detected an undercharge fault with 70.6% accuracy, concurrent duct leakage and undercharge faults with 85.2% accuracy, and duct leakage faults with 69.1% accuracy. A sensitivity analysis is also performed on EnergyPlus models of nine types of homes that vary in construction to demonstrate the robustness of the algorithm. Finally, the algorithm achieves an average accuracy of 71% for no-fault condition, 77% for 40% undercharge fault, and 76% for duct-leak fault.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improving air leakage prediction of buildings using the fan pressurization method with the Weighted Line of Organic Correlation

In many countries, the fan pressurization method is the most frequently chosen approach for measuring the air leakage of houses. The measurements are usually performed at pressures that far exceed pressures to which buildings are exposed to under normal conditions. A fit of these tests to the power-law formulation allows an extrapolation to data points outside the measured pressure range. With the Ordinary Least Square (OLS) fitting method, the pressure exponent and flow coefficient can be determined. However, the measurement results are highly sensitive to uncertainties induced by external factors like changing wind conditions during the tests, which is neglected by OLS. This may lead to errors in the prediction of flows at lower pressures. The Weighted Line of Organic Correlation (WLOC) is an alternative approach and takes measurement uncertainty into account. In this paper, a statistical analysis of an extensive data set of pressurization measurements has been performed. Both regression techniques have been compared for almost 7500 fan pressurization measurements of six houses in 109 different house leak configurations. The variability in predicting pressure exponent and flow coefficient for both WLOC and OLS regression was analyzed using probability density functions. It was found that the Weighted Line of Organic Correlation significantly decreases the uncertainty in predicting pressure exponent, flow coefficient, and other low-pressure air leakage metrics compared to the Ordinary Least Square fitting. Here, the authors highly recommend the implementation of WLOC in current measurement standards and test equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Application of reference-free natural background–oriented schlieren photography for visualizing leakage sites in building walls

Air leakage in buildings can cause health and comfort concerns for occupants and can contribute to mold growth on building materials, or in extreme conditions, rot of building materials. Unwanted air leakage through the building envelope also contributes to approximately 4 quadrillion Btu (1172 TWh) of energy consumption per year in the building sector in the United States. Locating and sealing leakage sites can improve the energy efficiency, comfort, air quality, and moisture durability of the building stock. Typical methods of finding leakage sites, such as infrared imaging and smoke tracing, rely on concurrent blower door operation, which can also measure the total leakage rate of the building. Smoke tracing can be disruptive to occupants, and infrared imaging and smoke tracing cannot measure the contribution of individual leaks to prioritize sealing efforts. Here, an optical fluid flow imaging technique, reference-free natural background–oriented schlieren imaging, was adapted to visualize air exfiltration. This is the first step in developing a method to noninvasively locate and measure exfiltration or infiltration sites so that sealing efforts can be prioritized. Experimental results of this technique are presented, demonstrating the method's applicability to visualizing exfiltration through three common building claddings in an outdoor environment. Key variables impacting the performance of this technique when applied to building leakage are also discussed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electromechanical memcapacitor model offering biologically plausible spiking.

In this article, we introduce a new nanoscale electromechanical device - a leaky memcapacitor - and show that it may be useful for the hardware implementation of spiking neurons. The leaky memcapacitor is a movableplate capacitor that becomes quite conductive when the plates come close to each other. The equivalent circuit of the leaky memcapacitor involves a memcapacitive and memristive system connected in parallel. In the leaky memcapacitor, resistance and capacitance depend on the same internal state variable, which is the displacement of the movable plate. We have performed a comprehensive analysis showing that several types of spiking observed in biological neurons can be implemented with the leaky memcapacitor. Significant attention is paid to the dynamic properties of the model. As in leaky memcapacitors the capacitive, leaking resistive, and reset functionalities are implemented naturally within the same device structure, their use will simplify the creation of spiking neural networks.

Zhang, Zixi↗

Portable chemical detection platform for on-site monitoring of odorant levels in natural gas

The adequate odorization of natural gas is critical to identify gas leaks and to reduce accidents. To ensure odorization, natural gas utility companies collect samples to be processed at core facilities or a trained human technician smells a diluted natural gas sample. In this work, we report a detection platform that addresses the lack of mobile solutions capable of providing quantitative analysis of mercaptans, a class of compounds used to odorize natural gas. Detailed description of the platform hardware and software components is provided. Designed to be portable, the platform hardware facilitates extraction of mercaptans from natural gas, separation of individual mercaptan species, and quantification of odorant concentration, with results reported at point-of-sampling. The software was developed to accommodate skilled users as well as minimally trained operators. Detection and quantification of six commonly used mercaptan compounds (ethyl mercaptan, dimethyl sulfide, n-propylmercaptan, isopropyl mercaptan, tert–butyl mercaptan, and tetrahydrothiophene) at typical odorizing concentrations of 0.1–5 ppm was performed using the device. We demonstrate the potential of this technology to ensure natural gas odorizing concentrations throughout distribution systems.

03 NATURAL GAS↗

Modeling the corrosion of steel casing and the damage of well cement in a borehole system

This work presents the effect of chloride-induced corrosion in an underground borehole system, specifically considering the steel casing and further damage to the surrounding cement. In the past four decades, oil well cement has been successfully used for underground construction. However, high concentrations of chloride ions gradually degrade the functionality and durability of well cement. Gasses and liquids can leak from deterioration caused by chloride ions, and thus motivate this study. The chemo-mechanical coupling diffusion model and a classical fracture mechanics model are applied. The model is validated with OPC concrete corrosion data from literature, and then applied to well cement using experimentally obtained material property data. The time when crack initiation, peak pressure, and complete fracture is reached in the model of the cement sheath provides a quantification of the expected service life of the borehole system.

36 MATERIALS SCIENCE↗

Natural fibers as promising core materials of vacuum insulation panels

To reduce energy consumption in buildings, this paper investigates the feasibility of using natural fibers as cost-effective, environmentally sustainable core materials for vacuum insulation panels (VIPs). First, a comprehensive experimental study was conducted for 10 potential natural fiber candidates. The thermal conductivities of the 10 natural fiber mats at various vacuum pressures were measured; their compression and morphology properties were quantified. In addition, an analytical model was used to explore the major factors that influence the thermal conductivity of natural fibers as a function of internal air pressure. Results show that recycled cotton, kapok, and bamboo fibers are ideal candidates for VIP core materials; at <0.05 Pa, their thermal conductivities varied between 2 and 4 mW/(m∙K). Furthermore, for some fibers, thermal conductivity was inversely proportional to fiber density. For the selection of fiber materials for VIP cores, the ideal fiber candidate has a small fiber diameter and a low fiber mat density. Based on thermal measurements, even though the internal air pressure of 5 Pa was enough to attain the minimum thermal conductivity, obtaining internal air pressure below 5 Pa is recommended for prolonged service life, considering small leaks of VIP package barrier films and potential off-gassing from fibers. The simulation results predicting the effective thermal conductivities matched the experimental results well. These findings indicate that natural fiber–based VIPs have the potential to be a sustainable, inexpensive alternative to the current technologies in building insulation materials.

36 MATERIALS SCIENCE↗

Automated fault detection of residential air-conditioning systems using thermostat drive cycles

Residential air conditioning equipment comprises a significant portion of the total energy consumption of a home. Unfortunately, air-conditioning systems can be susceptible to faulty operation either from installation errors or faults that accrue over the equipment’s lifetime. This paper presents a novel automated fault detection algorithm for residential air-conditioning systems that can alert the homeowner of the presence of these faults. The proposed algorithm utilizes only the home’s thermostat and outside air temperature to perform automated fault detection over the course of the equipment’s lifetime, including immediately after installation. The algorithm uses an extended Kalman filter approach to identify a three-resistor, two-capacitor (3R2C) electrical equivalent thermodynamic model. The identified 3R2C model is used to predict cooling times during a testing period comprising of a series of thermostat drive-cycle experiments. We tested the algorithm on an EnergyPlus™ model of a typical residential building in Orlando, Florida. Duct faults, indoor airflow faults, and refrigerant undercharge faults were introduced into the building model one at a time. The algorithm was able to accurately determine duct-leak faults, 40% airflow faults, 40% undercharge faults, and no-fault cases with an accuracy of 70%, 77%, 82%, and 87%, respectively.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimal pumping schedule with high-viscosity gel for uniform distribution of proppant in unconventional reservoirs

Hydrocarbon recovery from a hydraulic-fractured unconventional reservoir can be enhanced by replacing slickwater with non-Newtonian high-viscosity gel as a fracturing fluid. However, in the literature, the role of gel rheology on hydrocarbon production from a fractured reservoir is not very well understood. This lack of understanding makes it difficult for the industry to choose appropriate viscosity parameters of fracturing gels. Motivated by these limitations, first, we have developed a high-fidelity model of non-Newtonian fluid flow to simulate fracture propagation, fluid leak-off, and gel flowback processes to predict the oil production from a hydraulic fractured reservoir. Simulation results of the high-fidelity model show how fracture geometry, formation damage, and gel cleanup process varies with the fracturing fluid rheology. Therefore, the developed model is used to understand the effect of gel rheology on hydrocarbon production via a sensitivity analysis, which provides a set of rheological parameters that maximize the cumulative amount of oil production. Finally, utilizing this optimal high-viscosity gel, a model predictive controller is designed to obtain an optimal pumping schedule necessary for producing a target fracture geometry and proppant concentration. The closed-loop simulation results demonstrate that the obtained pumping schedule successfully achieved the desired fracture geometry and proppant concentration at the end of pumping, leading to the maximum oil production from an unconventional reservoir.

13 HYDRO ENERGY↗

Synergistic foam stabilization and transport improvement in simulated fractures with polyelectrolyte complex nanoparticles: Microscale observation using laser etched glass micromodels

Inaccessibility to direct pore scale observation in hydrocarbon recovery of tight shale formations poses a great challenge to water-energy nexus initiatives and necessitates the use of high throughput technologies to emulate environmentally friendly processes. Herein, we employ a precise glass micromodel fabrication and visualization method to isolate the supercritical CO 2 bubbles surrounded by CO 2 -water lamella prepared in saline produced water stabilized with molecular complexation of zwitterionic surfactants (ZS) and polyelectrolyte complex nanoparticles (PECNP). The Selective Laser Enhanced Etching (SLE) technique was selected for micromodel simulation of high-pressure flow. Two representative designs, (1) fracture/micro-crack network 28 and (2) fracture/matrix were etched on fused silica glass with a laser printing machine and scCO 2 foam was injected to study the foamability, propagation, stability, and fluid loss properties. The highly monodispersed and uniformly distributed array of scCO 2 bubbles were detected in flow of scCO 2 foam in highly saline brine containing ionic complexes of positively charged PECNPs and ZS, whereas foam flow with the lamella containing ZS in fractures offered a noticeably large and polydisperse array of scCO 2 bubbles. scCO 2 bubble motion and deformation were traced, and local description of foam flow was visually examined. The confined array of scCO 2 bubbles stabilized by ZS in microcracks was affected by bubble growth and coalescence, whereas the super-populated array of monodispersed scC O2 bubbles with lamella containing complexes of PECNP and ZS were able to fill the channels with stable configurations within the timeframe of comparative stability measurements. The ability of complex fluid to prevent the formation damage was evaluated through fluid loss visualization in micromodels. Probing scCO 2 foam transport in homogenous porous media revealed smaller volume leak-off for scCO 2 foam containing PECNP-ZS ionic complexes.

04 OIL SHALES AND TAR SANDS↗

Software stewardship and advancement of a high-performance computing scientific application: QMCPACK

Here, we provide an overview of the software engineering efforts and their impact in QMCPACK, a production-level ab-initio Quantum Monte Carlo open-source code targeting high-performance computing (HPC) systems. Aspects included are: (i) strategic expansion of continuous integration (CI) targeting CPUs, using GitHub Actions own runners, and NVIDIA and AMD GPUs used in pre-exascale systems, (ii) incremental reduction of memory leaks using sanitizers, (iii) incorporation of Docker containers for CI and reproducibility, and (iv) refactoring efforts to improve maintainability, testing coverage, and memory lifetime management. We quantify the value of these improvements by providing metrics to illustrate the shift towards a predictive, rather than reactive, maintenance approach. Our goal, in documenting the impact of these efforts on QMCPACK, is to contribute to the body of knowledge on the importance of research software engineering (RSE) for the stewardship and advancement of community HPC codes to enable scientific discovery at scale.

97 MATHEMATICS AND COMPUTING↗

The need to consider regional supply chains and water usage in H 2 –steel transition

The iron and steel industry is one of the largest contributors to U.S. and global greenhouse gas emissions. Hydrogen can act as a promising reducing agent and clean energy carrier to decarbonize this sector, and has received significant attention in terms of process modelling, techno-economic analysis, and life cycle assessment in recent years. Policy incentives, hydrogen storage and transportation, and water stress levels are key factors that require significantly more consideration in order to realize hydrogen’s potential to decarbonize this industry. This review demonstrates the need for a systematic understanding and critical assessment of these areas, and their profound impacts on the decarbonization of the iron and steel sector. Furthermore, hydrogen and water supply face competition from other hard-to-decarbonize sectors, which should be considered on national and regional levels. Lastly, future research should also consider the impact of other environmental factors and hydrogen leak when deploying hydrogen at scale for industrial decarbonization.

Green steel↗

Feasibility of using in situ deformation to monitor CO 2 storage

Deformation during CO 2 injection can lead to problems, like seismicity or fluid leaks, but small strains have the potential to be a useful signal for monitoring. The objective of this paper is to evaluate the possible evolution of the strain field during injection, and then assess existing and emerging techniques for measuring the strain field. Poroelastic analyses show that normal strains caused by injection into a reservoir are tensile in the vicinity of the well, but everywhere else at least one strain component is compressive. The vertical strain is compressive in the confining unit, and the radial strain decreases and changes sign from tensile to compressive with distance from the well. Tilting is away from the injection well at the ground surface, but it is towards the well overlying the reservoir. Methods for measuring in-situ strain include instruments that are grouted in the annulus between casing and wall rock (~ 0.1 microstrain resolution), portable strain sensors that are temporarily clamped to the borehole wall (~0.01 microstrain resolution), and strainmeters that are grouted in place (~0.001 microstrain resolution). Instruments for measuring in-situ normal strains at the magnitudes and rates expected during injection are emerging, but they have yet to be fully evaluated in applications related to CO 2 storage. Finally, in-situ strain data measured with emerging instruments promises to fill an important gap between the episodes of fast strain rates measured by seismic data, and the slow strains measured over relatively long periods of time by InSAR and GPS.

42 ENGINEERING↗

Feasibility of using reactive silicate particles with temperature-responsive coatings to enhance the security of geologic carbon storage

The large-scale deployment of geologic carbon storage will require minimizing the risk of CO 2 leakage. Here we report on a novel strategy to seal leakage pathways by injecting functionalized reactive calcium silicate (CaSiO 3 ) particles. The particles consist of a mineral silicate core within a temperature-sensitive Poly(N,N-dimethylaminoethyl methacrylate) coating that limits contact between the core and the surrounding CO 2 (aq) above a switching temperature making them relatively unreactive deep in the subsurface. If the CO 2 leaks to shallower depths and cooler temperatures, the coatings would extend and enable the silicate core to react with CO 2(aq) to form solid carbonate precipitates that reduce the permeability of the fracture or flow path. A combined laboratory- and simulation-based investigation was conducted to explore key early-stage research questions related to the feasibility of this leakage management strategy. Sand columns were injected with either coated or uncoated CaSiO 3 particles and the permeability was measured before and after exposure to CO 2 . Experiments were conducted at 35 °C and 70 °C, a range that spans the switching temperature for the coatings. Results show that at the cooler temperature the coating effectively enabled reaction and permeability reduction. At higher temperatures, the coated particles limited mineral carbonation and the permeability decrease was minimal compared to columns with uncoated particles. Here, the morphology and location of the precipitates provides insight about permeability evolution. Model simulations of 2D radial particle transport from an injection point provided insight into the effects of particle size, coating properties, and concentrations of particles in several representative rock formations.

54 ENVIRONMENTAL SCIENCES↗

Application of emerging monitoring techniques at the Illinois Basin – Decatur Project

The Illinois Basin – Decatur Project is a large-scale carbon capture and storage demonstration project located in Decatur, Illinois, USA. In this project, one million metric tons of carbon dioxide (CO 2 ) was captured from an ethanol production facility and successfully injected into a deep saline reservoir over a period of three years. The scale of this project presented an opportunity to explore emerging technologies for effective long-term monitoring of the carbon capture and storage site. This research documents the application of three emerging monitoring techniques: (1) a prototype “open-path” sensor, a method of continuously monitoring atmospheric CO 2 by applying tunable diode laser absorption spectroscopy to provide a warning system for personnel safety along pipelines and at wellheads; (2) the Greenhouse Gas Laser Imaging Tomography Experiment (GreenLITE), an automated system for measuring two-dimensional spatial distribution of atmospheric CO 2 concentrations; and (3) periodic aerial imagery, a method of documenting surface-vegetation dynamics to detect vegetative responses to CO 2 leaks. The objective of this work was to assess the advantages and limitations of these monitoring techniques and quantify their reliability over an extended deployment at an active industrial site. These results will aid in determining viability of long-term monitoring on a commercial scale.

42 ENGINEERING↗

Tracking natural CO 2 migration through a sandstone aquifer using Sr, U and C isotopes: Chimayó, New Mexico, USA

The geochemical and isotopic characteristics of groundwaters in Chimayó, New Mexico, reflect processes that affect water quality in the Tesuque Aquifer, which overlies a leaking natural CO 2 source in a structurally complex region. In this study, select isotopes (δ 13 C, 87 Sr/ 86 Sr, 234 U/ 238 U) are applied to groundwaters to better understand CO 2 transport mechanisms and related water-rock interactions that impact Chimayó groundwater. Carbon stable isotope ratios of dissolved inorganic carbon (DIC; δ 13 CDIC = -15.10‰ to 4.50‰) identify a distinct source of upward-migrating CO 2 that interacts with the groundwater. Additionally, groundwater 87 Sr/ 86 Sr compositions (0.7098 to 0.7154) reflect intrusion of varying amounts of saline water associated with the high CO 2 source, while 234 U/ 238 U ratios corroborate presence of deep groundwater and suggest impacts from distinctive natural uranium sources are affecting groundwater. Previous work proposed two CO 2 transport mechanisms at the site: (1) dissolved in deep brine that underlies the aquifer and (2) in the gas phase; this study uses isotope mixing models to identify wells that are affected by these CO 2 transport mechanisms and demonstrates that both transport mechanisms are associated with impaired groundwaters. Overall, this study demonstrates that applying multiple isotope systems (δ 13 CDIC, 87 Sr/ 86 Sr, 234 U/ 238 U) is a dynamic tool for identifying and measuring the impact of CO 2 leakage from a sequestration site.

58 GEOSCIENCES↗