Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOSS OF COOLANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A User Guide to PARET/ANL

PARET was originally created in 1969 at what is now Idaho National Laboratory (INL), to analyze reactivity insertion events in research and test reactor cores cooled by light or heavy water, with fuel composed of either plates or pins. The use of PARET is also appropriate for fuel assemblies with curved fuel plates when their radii of curvatures are large with respect to the fuel plate thickness. The PARET/ANL version of the code has been developed at Argonne National Laboratory (ANL) under the sponsorship of the U.S. Department of Energy/NNSA since the inception of the Reactor Conversion Program. Since Reduced Enrichment for Research and Test Reactors (RERTR) began in 1978, PARET/ANL has been benchmarked to experimental data including SPERT testing, and used to determine the expected transient behavior of a large number of reactors regardless of enrichment both inside and outside the Reactor Conversion Program. This document provides the pertinent information for the use of PARET/ANL Version 7.6. PARET/ANL models the various fueled regions of a reactor core as channels. Each of these channels consists of a single flat fuel plate/pin (including cladding and, optionally, a gap) with water coolant on each side. In slab geometry the coolant channels for a given fuel plate are of identical dimensions (mirror symmetry), but they can be of different thickness in each channel. There can be many channels, but each channel is independent and coupled only through reactivity feedback effects to the whole core. The time-dependent differential equations that represent the system are replaced by an equivalent set of finite-difference equations in space and time, which are integrated numerically. PARET/ANL uses fundamentally the same numerical scheme as RELAP5 for the time-integration of the point-kinetics equations. The one-dimensional thermal-hydraulic model includes temperature-dependent thermal properties of the solid materials, such as heat capacity and thermal conductivity, as well as the transient heat production and heat transfer from the fuel meat to the coolant. Temperature- and pressure-dependent thermal properties of the coolant such as enthalpy, density, thermal conductivity, and viscosity are also used in determining parameters such as friction factors and heat transfer coefficients. The code first determines the steady-state solution for the initial state. Then the solution of the transient is obtained by integration in time and space. Multiple heat transfer, DNB and flow instability correlations are available. The code was originally developed to model reactors cooled by an open loop, which was adequate for rapid transients in pool-type cores. An external loop model appropriate for Miniature Neutron Source Reactors (MNSR’s) was also added to PARET/ANL to model natural circulation within the vessel, heat transfer from the vessel to pool and heat loss by evaporation from the pool. PARET/ANL also contains models for decay heat after shutdown, control rod reactivity versus time or position, time-dependent pump flow, and loss-of-flow event with flow reversal as well as logic for trips on period, power, and flow. Feedback reactivity effects from coolant density changes and temperature changes are represented by tables. Feedback reactivity from fuel heat-up (Doppler Effect) is represented by a four-term polynomial in powers of fuel temperature. Photo-neutrons produced in beryllium or in heavy water may be included in the point-kinetics equations by using additional delayed neutron groups.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Coolant side heat transfer with rotation. Task 3 report: Application of computational fluid dynamics

An experimental and analytical program was conducted to investigate heat transfer and pressure losses in rotating multipass passages with configurations and dimensions typical of modern turbine blades. The objective of this program is the development and verification of improved analysis methods that will form the basis for a design system that will produce turbine components with improved durability. As part of this overall program, a technique is developed for computational fluid dynamics. The specific objectives were to: select a baseline CFD computer code, assess the limitations of the baseline code, modify the baseline code for rotational effects, verify the modified code against benchmark experiments in the literature, and to identify shortcomings in the code as revealed by the verification. The Pratt and Whitney 3D-TEACH CFD code was selected as the vehicle for this program. The code was modified to account for rotating internal flows, and these modifications were evaluated for flow characteristics of those expected in the application. Results can make a useful contribution to blade internal cooling.

Kopper, F. C.↗

Flow boiling with enhancement devices for cold plate coolant channel design

Future space exploration and commercialization will require more efficient heat rejection systems. For the required heat transfer rates, such systems must use advanced heat transfer techniques. Forced two phase flow boiling heat transfer with enhancements falls in this category. However, moderate to high quality two phase systems tend to require higher pressure losses. This report is divided into two major parts: (1) Multidimensional wall temperature measurement and heat transfer enhancement for top heated horizontal channels with flow boiling; and (2) Improved analytical heat transfer data reduction for a single side heated coolant channel. Part 1 summarizes over forty experiments which involve both single phase convection and flow boiling in a horizontal channel heated externally from the top side. Part 2 contains parametric dimensionless curves with parameters such as the coolant channel radius ratio, the Biot number, and the circumferential coordinate.

Boyd, Ronald D.↗

Temperature controller for a fluid cooled garment

An automatic controller for controlling the inlet temperature of the coolant to a fluid cooled garment without requiring skin sensors is described. Temperature is controlled by the wearer's evaporative water loss rate.

Chambers, A. B.↗

Fuel Performance Evaluation of THOR-C Experiments

The Temperature Heatsink Overpower Response Commissioning (THOR-C) and THOR-Metal (THOR-M) experiments will be performed as part of an ongoing project for testing sodium fast reactor fuels with the Japan Atomic Energy Agency (JAEA). The THOR-C experiments consist of fresh metallic fuel pins and have been analyzed using the ABAQUS, Ansys codes and the BISON fuel performance code. THOR-M-Loss of Flow-1 (THOR-M-LOF-1) is designed to test an EBR-II irradiated fuel pin under LOF conditions. Simulation of the THOR-MLOF-1 experiment required first simulating the base irradiation of the fuel pin in EBR-II. MFUEL module of SAS4A/SASSYS-1 [1] is a physics-based metallic fuel performance model applicable to the normal operation, transient scenarios and fuel failure modeling including scenarios with bulk fuel melting. The model has been validated using EBR-II normal operation, separate effect transient tests as well as TREAT M-Series transient tests [2]. In this study, MFUEL models has been utilized together with a new capsule heat transfer model developed in this project. The new heat transfer model was necessary due to (1) significant amount of heat losses that required 2D heat transfer, (2) the presence of a titanium heat sink, rejecting a significant amount of heat, and (3) stagnant coolant conditions, which are inconsistent with SAS4A/SASSYS-1 (SAS) heat transfer model. Updates to SAS4A/SASSYS-1 and MFUEL has been described below, followed by a preliminary validation effort using the results from THOR-C-2 fresh fuel capsule experiment. A previous study for THOR-C-2 analysis using BISON code is also utilized in this study to model this test [3]. [1] D. O’Grady, A. J. Brunett, L. Ibarra, A. Karahan, T. Kim, T. S. Sumner, R. Thomas, T. H. Fanning, “The SAS4A/SASSYS-2 Version 5.7 Safety Analysis Code System,” Argonne National Laboratory,ANL/NSE-SAS/5.7, (2023). [2] A. Karahan, T. Kim, T. Fanning, D. O’Grady, “Validation of MFUEL Metal Fuel Performance Models of SAS4A/SASSYS-1,” Argonne National Laboratory, ANL/NSE-23/11, (2023). [3] M. Mihelish, A. Zabriskie, K. Paaren, P. Medvedev, C. Jensen, “Fuel Performance Predictions for the TREAT THOR-C Experiments,” Idaho National Laboratory, INL/RPT-23-73397, Revision 0, (2023)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility of water injection into the turbine coolant to permit gas turbine contingency power for helicopter application

A system which would allow a substantially increased output from a turboshaft engine for brief periods in emergency situations with little or no loss of turbine stress rupture life is proposed and studied analytically. The increased engine output is obtained by overtemperaturing the turbine; however, the temperature of the compressor bleed air used for hot section cooling is lowered by injecting and evaporating water. This decrease in cooling air temperature can offset the effect of increased gas temperature and increased shaft speed and thus keep turbine blade stress rupture life constant. The analysis utilized the NASA-Navy-Engine-Program or NNEP computer code to model the turboshaft engine in both design and off-design modes. This report is concerned with the effect of the proposed method of power augmentation on the engine cycle and turbine components. A simple cycle turboshaft engine with a 16:1 pressure ratio and a 1533 K (2760 R) turbine inlet temperature operating at sea level static conditions was studied to determine the possible power increase and the effect on turbine stress rupture life that could be expected using the proposed emergency cooling scheme. The analysis showed a 54 percent increse in output power can be achieved with no loss in gas generator turbine stress rupture life. A 231 K (415 F) rise in turbine inlet temperature is required for this level of augmentation. The required water flow rate was found to be .0109 kg water per kg of engine air flow.

Vanfossen, G. J.↗

Achieving 5,000-h and 8,000-h Low-PGM Electrode Durability on Automotive Drive Cycles

Whereas total Pt loading in anode and cathode catalysts below 0.125 mg cm −2 is required to meet the stringent cost target for automotive fuel cell systems (FCS) for light duty vehicles, low-loaded cathode catalysts are susceptible to unacceptable aging-related performance losses at high current densities. A framework model, validated by accelerated stress test data, has identified cell voltage, relative humidity (RH) and temperature as the key operating variables that affect degradation of a high-activity d-PtCo/C cathode catalyst with 0.1 mg cm −2 Pt loading. Drive cycle simulations indicate that these can be controlled by properly selecting the minimum FCS power, compressor-expander module (CEM) turndown, and stack coolant temperature. The optimum system parameters are 4-kW e minimum power for an 80-kW e FCS, CEM turndown of 12.5, and 66 °C average coolant exit temperature that combine to limit the maximum cell voltage to 850 mV and outlet RH to 90%–100%. Depending on Pt loading, the mismatch between actual and allowable degradation for 10% power loss over 5,000-h lifetime requires the stack to be oversized by 2.4%–5%, resulting in 8.4%–41% lower Pt utilization and 7.1%–20.5% penalty in stack cost. The corresponding results for 8,000-h lifetime are 10.3%-14% stack oversizing, 23%–51.8% lower Pt utilization, and 24.1%–35.4% stack cost penalty.

08 HYDROGEN↗

Aero-Thermo-Structural Design Optimization of Internally Cooled Turbine Blades

A set of robust and computationally affordable inverse shape design and automatic constrained optimization tools have been developed for the improved performance of internally cooled gas turbine blades. The design methods are applicable to the aerodynamics, heat transfer, and thermoelasticity aspects of the turbine blade. Maximum use of the existing proven disciplinary analysis codes is possible with this design approach. Preliminary computational results demonstrate possibilities to design blades with minimized total pressure loss and maximized aerodynamic loading. At the same time, these blades are capable of sustaining significantly higher inlet hot gas temperatures while requiring remarkably lower coolant mass flow rates. These results suggest that it is possible to design internally cooled turbine blades that will cost less to manufacture, will have longer life span, and will perform as good, if not better than, film cooled turbine blades.

Dulikravich, G. S.↗

High power density compact drive integrated motor for electric transportation

This project, initially part of OPEN 2018, and subsequently the ASCEND effort, targeted demonstration of significant enhancements in internal permanent magnet (IPM) motor torque and power density for current and future ground and air electric transportation applications. These were achieved through: (1) embedded two-phase system thermal management, (2) coupled, multi-scale electrical-electromagnetic-thermal-mechanical co-design and optimization, (3) size and weight reduction of motor and drive electronics through elimination of redundant cooling and coupling hardware, and (4) higher efficiency operation of SiC wide bandgap power electronics packaging through high temperature operation (200 oC). The proposed approach utilizes a single dielectric coolant for closed loop two-phase thermal management, and a combined heat rejection unit for the IPM and drive. Wick assisted liquid delivery for evaporative thermal management is utilized for the motor, and the drive electronics utilize the same coolant in flow boiling within the cold plate structures. Through the use of three-dimensional packaging for SiC, and novel drive topologies with reduced switching losses, significant increases in power density and compactness were targeted.

33 ADVANCED PROPULSION SYSTEMS↗

Thermionic technology infrastructure for space power

An assessment is made of the potential effectiveness, designs, and technological difficulties involved in the construction of space nuclear reactors coupled to thermionic energy converters (TEC). The TECs can be positioned either inside or outside of the reactor core. The out-of-core design lowers the reactor shielding requirements, as well as removing the need for mechanically pumped coolant for the reactor. R&D is still needed for the heat pipes for the reactor and the collectors, electrical insulation, and to reduce the potential losses in the interelectrode space. A cylindrical converter for the out-of-core configuration consists of a tungsten emitter heated by a tungsten-lithium heat pipe. The collector is a layer of tungsten oxide deposited on a Nb-1%Zr alloy, and has been tested at emitter temperatures of 1300-1850 K and a collector temperature range of 700-850 K. A design of a superheated thermionic converter is described, noting that a prototype has been operated at 1730 K for 12,000 hr.

Huffman, F.↗

Semi-Annual Report for Horizontal Compact High Temperature Gas Reactor (HC-HTGR) Development during Performance Period October 2022-March 2023

Horizontal Compact High Temperature Gas Reactor (HC-HTGR) is being designed by a multi-disciplinary team of nuclear, mechanical, and structural engineers under the support of a DOE-NE Advanced Reactor Demonstration Program’s Advanced Reactor Concepts-20 (ARC-20) award. The objective of this ARC-20 project is to deliver a conceptual design for the proposed HC-HTGR in 3 years and support its commercialization as a safe, low-cost HTGR. Argonne National Laboratory (Argonne) is responsible for the design and analysis of the reactor cavity cooling system (RCCS) as a safety system for passive decay heat removal of the reactor concept. Additionally, Argonne is providing analysis of the primary heat transport system to ensure temperatures in the reactor systems, structures and components with significant safety margins during normal operation and design basis accident scenarios. This third semi-annual report summarized the progress made at Argonne on the two tasks during the first half of FY23. As a part of the RCCS design task, a design process for the water panel and the system configuration was performed to improve the thermal performance of the RCCS. The updated water panel design had achieved enhanced thermal performance with 0.96 MWth capability with major design updates made in structural interfaces with the RPV and initial configuration of the water tanks. The loop configuration of the RCCS has been proposed to have two independently working loops for system redundancy. A water panel material study was performed focusing on the use of carbon steel in water systems. Additional modeling strategies of primary system thermal fluids analyses were developed to meet modeling needs that are not well suited for the 1D-3D assembly level approach. The first of these is a reduced order assembly model, in which fuel centered unit cells are used to represent a fuel assembly. The 2D approach used in this model is much more computationally efficient, making this model useful for full core transient scenarios where fuel to coolant heat transfer is still the dominant flow path. The next model is the 3D core conduction model to be used to analyze decay heat removal in loss of primary system flow scenarios. Because these scenarios require a large domain to be modeled, a homogenized core model is being pursued to reduce the required computational costs. To accurately model decay heat scenarios it is necessary to couple a RCCS model to the 3D core conduction model. A simplified case is presented to demonstrate how the coupling methodology will be applied to the full core 3D conduction model.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessing the Impact of Effective Thermal Conductivity on Gas-cooled Reactor Transients in RELAP5-3D

High-temperature gas-cooled reactors (HTGRs) are a relatively mature advanced reactor concept that are of interest to industry and government for near-term deployment. These systems feature passive safety through low power density, coated particle fuels, and large graphite volumes that lead to slow heatup. In loss of flow transients, cooldown is achieved through conduction and radiation heat transfer. In prismatic block-type reactors, such as the mHTGR-350, the presence of coolant holes and fuel compacts alters the flow of heat through the blocks. To capture this effect in systems codes like RELAP5-3D, relationships for effective thermal conductivity (ETC) must be used to appropriately degrade the thermal conductivity. This work presents an assessment of the impact of ETC on performance of block-type gas-cooled reactors in a pressurized conduction cooldown (PCC) and depressurized conduction cooldown (DCC) transients. Models for PCC and DCC with bulk material thermal conductivity and ETC were run for both the mHTGR-350 and the High-Temperature Test Facility (HTTF) to determine the impact of ETC on transient performance.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Cyclic Phase Change and Energy Storage in Solar Heat Receivers

Numerical results pertaining to cyclic melting and freezing of an encapsulated phase change material (PCM), integrated into a solar heat receiver, have been reported. The cyclic nature of the present melt/freeze problem is relevant to latent heat thermal energy storage (LHTES) systems used to power solar Brayton engines in microgravity environments. Specifically, a physical and numerical model of the solar heat receiver component of NASA Lewis Research Center's Ground Test Demonstration (GTD) project was developed and results compared with available experimental data. Multi-conjugate effects such as the convective fluid flow of a low-Prandtl-number fluid, coupled with thermal conduction in the phase change material, containment tube and working fluid conduit were accounted for in the model. A single-band thermal radiation model was also included to quantify reradiative energy exchange inside the receiver and losses through the aperture. The eutectic LiF-CaF2 was used as the phase change material (PCM) and a mixture of He/Xe was used as the working fluid coolant. A modified version of the computer code HOTTube was used to generate results for comparisons with GTD data for both the subcooled and two-phase regimes. While qualitative trends were in close agreement for the balanced orbit modes, excellent quantitative agreement was observed for steady-state modes.

Hall, Carsie A., III↗

Parametric Analysis of Cyclic Phase Change and Energy Storage in Solar Heat Receivers

A parametric study on cyclic melting and freezing of an encapsulated phase change material (PCM), integrated into a solar heat receiver, has been performed. The cyclic nature of the present melt/freeze problem is relevant to latent heat thermal energy storage (LHTES) systems used to power solar Brayton engines in microgravity environments. Specifically, a physical and numerical model of the solar heat receiver component of NASA Lewis Research Center's Ground Test Demonstration (GTD) project was developed. Multi-conjugate effects such as the convective fluid flow of a low-Prandtl-number fluid, coupled with thermal conduction in the phase change material, containment tube and working fluid conduit were accounted for in the model. A single-band thermal radiation model was also included to quantify reradiative energy exchange inside the receiver and losses through the aperture. The eutectic LiF-CaF2 was used as the phase change material (PCM) and a mixture of He/Xe was used as the working fluid coolant. A modified version of the computer code HOTTube was used to generate results in the two-phase regime. Results indicate that parametric changes in receiver gas inlet temperature and receiver heat input effects higher sensitivity to changes in receiver gas exit temperatures.

Hall, Carsie A., III↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

W T Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

William T. Wallace↗

ECAR-6599 Rev 0 PCAT Walls Temperature Distribution, Beryllium Inserts and Fuel-to-Fuel Gap Tolerance Analysis

This document reports the primary coolant system structures temperature distribution for the Primary Coolant Apparatus Test (PCAT) of the MARVEL microreactor. The temperature distributions have been calculated using the RELAP5-3D system code, using one-dimensional approximation, and considering radial heat losses, effects of thermal insulators, and hot spot factors. Sensitivities on the Be inserts dimensions tolerances and heater-to-heater pitch has been also performed, investigating the effects on the NaK and heater cartridge sheath temperatures.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗