Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Ablation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Guidance and Control for Laser-Based Non-Cooperative Target Detumbling

Large pieces of orbital debris form a significant risk of fragmentation in case of collision. Such fragmentation would greatly increase the number of trackable and untrackable debris on orbit. This makes them attractive targets for future rendezvous and disposal missions. However, these non-cooperative targets tend to be tumbling and rendezvous with them is a dangerous prospect. To avoid this danger, contactless detumbling through laser ablation has been proposed prior to rendezvous. Existing proposals for contactless laser-based detumbling have yet to include an in-depth study of the problem's guidance, navigation, and control requirements. In this work we develop an attitude and relative motion control scheme for a chaser satellite detumbling a non-cooperative target via laser. We show that detumbling can be achieved with reasonable time and dV budgets. With Monte Carlo methods we explore the impact of laser force on the detumbling operation and reveal some non-intuitive relationships.

Guidance↗

Double-walled containment cell

Double-walled containment cells are described as may be used for storage, transport, and examination of a sample held within the cell by use of optical analysis techniques. A double-walled containment cell can include multiple types of windows that can be located as desired on the containment cells and thereby provide for optical access to a sample for multiple optical analysis techniques. Disclosed containment cells can be sized and designed for use with existing optical analysis systems, e.g., laser ablation, X-ray diffraction, spectral analysis (e.g., Raman spectroscopy, infrared spectroscopy, laser-induced breakdown spectroscopy, etc.), imaging analysis, etc.

Villa-Aleman, Eliel↗

Spectroscopic and Computational Studies of Spin-Orbit Coupling of Lanthanide Oxides

Spin-orbit (SO) coupling makes it possible for spin forbidden transitions or reactions within non-relativistic quantum theory feasible. Thus, quantification of such interactions has important implications in photophysics and chemical catalysis. This work aims to quantify SO interactions using lanthanide (Ln) oxides as target molecular systems. Through these systems, we examine the impact on the SO coupling by electron configurations and 4f orbital occupancies of Ln elements and sizes of the metal oxides. By examining these factors, we explore how SO coupling is affected by the number of Ln 4f electrons for a given size of molecules and if the Ln 4f orbitals remain atomic in nature in these small clusters. Ln oxides are produced in laser ablation molecular beams, identified with time-of-fight mass spectrometry, and characterized with laser spectroscopy and relativistic quantum chemical computations. Spectroscopic measurements include mass-analyzed threshold ionization (MATI), zero electron kinetic energy, and slow electron velocity-map imaging spectroscopies. Relativistic computations treat scalar relativistic corrections, electron correlations, and SO interactions. The main results are SO terms and energies of the neutral molecules and singly charged cations, ionization energies of the neutral species, metal-metal and metal-oxygen vibrational frequencies of the ions and, in some cases, neutrals as well, and charge effects on the bonding and structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The interplay between laser focusing conditions, expansion dynamics, ablation mechanisms, and emission intensity in ultrafast laser-produced plasmas

The interplay between ultrafast laser focusing conditions, emission intensity, expansion dynamics, and ablation mechanisms is critical to the detection of light isotopes relevant to nuclear energy, forensics, and geochemistry applications. Here, we study deuterium (2Hα) emission in plasmas generated from femtosecond laser ablation of a Zircaloy-4 target with a deuterium concentration of ≈37 at. %. Changes in emission intensity, plume morphology, crater dimensions, and surface modifications were investigated for varying focusing lens positions, where the laser was focused behind, at, and in front of the target. Spatially resolved optical emission spectroscopy and spectrally integrated plasma imaging were performed to investigate emission spectral features and plume morphology. Laser ablation crater dimensions and morphology were analyzed via optical profilometry and scanning electron microscopy. The 2Hα emission intensity showed significant reduction at the geometrical focal point or when the focal point is in front of the target. For all laser spot sizes, a two-component plume was observed but with different temporal histories. At the best focal point, the plume was spherical. When the laser was focused behind the target, the plume was elongated and propagated to farther distances than for the best focal position. In contrast, when the laser was focused in front of the target, filaments were generated in the beam path, and filament-plasma coupling occurred. By focusing the laser behind the target, the amount of material removal in the laser ablation process can be significantly reduced while still generating a plasma with a sufficient 2Hα emission signal for analysis.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗

Genesis Noble Gas Measurements

The original thrust of our Genesis funding was to extend and refine the noble gas analytical capabilities of this laboratory to improve the precision and accuracy of noble gas measurements in order to optimize the scientific return from the Genesis Mission. This process involved both instrumental improvement (supplemented by a SRLIDAP instrument grant) and refinement of technique. The Genesis landing mishap shifted our emphasis to the irregular aluminum heat shield material from the flat collector wafers. This has required redesign of our laser extraction cells to accommodate the longer focal lengths required for laser extraction from non-flat surfaces. Extraction of noble gases from solid aluminum surfaces, rather than thin coatings on transparent substrates has required refinement of controlled-depth laser ablation techniques. Both of these bring new problems, both with potentially higher blanks form larger laser cells and the larger quantities of evaporated aluminum which can coat the sapphire entrance ports. This is mainly a problem for the heavy noble gases where larger extraction areas are required, necessitating the new aluminum vapor containment techniques described below. With the Genesis Mission came three new multiple multiplier noble gas mass spectrometers to this laboratory, one built solely by us (Supergnome-M), one built in collaboration with Nu-Instruments (Noblesse), and one built in collaboration with GVI (Helix). All of these have multiple multiplier detection sections with the Nu-Instruments using a pair of electrostatic quad lenses for isotope spacing and the other two using mechanically adjustable positions for the electron multipliers. The Supergnome-M and Noblesse are installed and running. The GVI instrument was delivered a year late (in March 2005) and is yet to be installed by GVI. As with all new instruments there were some initial development issues, some of which are still outstanding. The most serious of these are performance issues with the miniature channel electron multipliers. The delayed installation of Helix by the GVI is partly due to failure of the initial batch of Burle channel multipliers to perform as expected. A number of the channel multipliers designed for Noblesse by Burle have also failed upon baking. Burle has now refined the design of these and we have installed two of the new multipliers and are assessing their performance. The remaining multipliers Will be upgraded to the new design from Burle once we confirm that the problem has been fixed.

Hohenberg, Charles M.↗

Exploration of a Combined LIBS and LA-ICP-MS Approach for Apatite Characterisation

A combined laser‐induced breakdown spectroscopy (LIBS) and laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) method is demonstrated for comprehensive apatite analysis. These measurements provide elemental imaging that can be used as a screening technique for chemical selection of grains for subsequent analysis (e.g., U‐Pb geochronology) or can be used to understand elemental distributions within a single grain that would have direct textural‐chemical implications (e.g., zoning patterns). Adding LIBS as a simultaneous measurement, to LA‐ICP‐MS U‐Pb geochronology, allowed for the direct determination of F (H and O show promise for future applications) in addition to major and trace elements of interest. Here, the quantitative measurements were validated against a series of apatites with known values and used to characterise a wide range of samples. Fluorine detection limits were determined to be as low as 70 μg g ‐1 F (broadband CMOS detector) and 4.2 μg g ‐1 F (ICCD detector). U‐Pb age dating was simultaneously collected by LA‐ICP‐MS with the quantitative elemental data from LIBS, providing a comprehensive method for geochronology.

Apatite↗

Planar laser induced fluorescence mapping of a carbon laser produced plasma

We present measurements of ion velocity distribution profiles obtained by laser induced fluorescence (LIF) on an explosive laser produced plasma. The spatiotemporal evolution of the resulting carbon ion velocity distribution was mapped by scanning through the Doppler-shifted absorption wavelengths using a tunable, diode-pumped laser. The acquisition of these data was facilitated by the high repetition rate capability of the ablation laser (1 Hz), which allowed for the accumulation of thousands of laser shots in short experimental times. By varying the intensity of the LIF beam, we were able to explore the effects of fluorescence power against the laser irradiance in the context of evaluating the saturation vs the non-saturation regime. The small size of the LIF beam led to high spatial resolution of the measurement compared to other ion velocity distribution measurement techniques, while the fast-gate operation mode of the camera detector enabled the measurement of the relevant electron transitions.

Instruments & Instrumentation↗

Overview of Advanced Space Propulsion Activities in the Space Environmental Effects Team at MSFC

Exploration of our solar system, and beyond, requires spacecraft velocities beyond our current technological level. Technologies addressing this limitation are numerous. The Space Environmental Effects (SEE) Team at the Marshall Space Flight Center (MSFC) is focused on three discipline areas of advanced propulsion; Tethers, Beamed Energy, and Plasma. This presentation will give an overview of advanced propulsion related activities in the Space Environmental Effects Team at MSFC. Advancements in the application of tethers for spacecraft propulsion were made while developing the Propulsive Small Expendable Deployer System (ProSEDS). New tether materials were developed to meet the specifications of the ProSEDS mission and new techniques had to be developed to test and characterize these tethers. Plasma contactors were developed, tested and modified to meet new requirements. Follow-on activities in tether propulsion include the Air-SEDS activity. Beamed energy activities initiated with an experimental investigation to quantify the momentum transfer subsequent to high power, 5J, ablative laser interaction with materials. The next step with this experimental investigation is to quantify non-ablative photon momentum transfer. This step was started last year and will be used to characterize the efficiency of solar sail materials before and after exposure to Space Environmental Effects (SEE). Our focus with plasma, for propulsion, concentrates on optimizing energy deposition into a magnetically confined plasma and integration of measurement techniques for determining plasma parameters. Plasma confinement is accomplished with the Marshall Magnetic Mirror (M3) device. Initial energy coupling experiments will consist of injecting a 50 amp electron beam into a target plasma. Measurements of plasma temperature and density will be used to determine the effect of changes in magnetic field structure, beam current, and gas species. Experimental observations will be compared to predictions from computer modeling.

Edwards, David↗

Carbon Nanotube Activities at NASA-Johnson Space Center

Research activities on carbon nanotubes at NASA-Johnson Space Center include production, purification, characterization and their applications for human space flight. In-situ diagnostics during nanotube production by laser oven process include collection of spatial and temporal data of passive emission and laser induced fluorescence from C2, C3 and Nickel atoms in the plume. Details of the results from the "parametric study" of the pulsed laser ablation process indicate the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymednanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large surface area as well as high electrical and thermal conductivity exhibited by SWCNTs.

Arepalli, Sivaram↗

LightForce: An Update on Orbital Collision Avoidance Using Photon Pressure

We present an update on our research on collision avoidance using photon-pressure induced by ground-based lasers. In the past, we have shown the general feasibility of employing small orbit perturbations, induced by photon pressure from ground-based laser illumination, for collision avoidance in space. Possible applications would be protecting space assets from impacts with debris and stabilizing the orbital debris environment. Focusing on collision avoidance rather than de-orbit, the scheme avoids some of the security and liability implications of active debris removal, and requires less sophisticated hardware than laser ablation. In earlier research we concluded that one ground based system consisting of a 10 kW class laser, directed by a 1.5 m telescope with adaptive optics, could avoid a significant fraction of debris-debris collisions in low Earth orbit. This paper describes our recent efforts, which include refining our original analysis, employing higher fidelity simulations and performing experimental tracking tests. We investigate the efficacy of one or more laser ground stations for debris-debris collision avoidance and satellite protection using simulations to investigate multiple case studies. The approach includes modeling of laser beam propagation through the atmosphere, the debris environment (including actual trajectories and physical parameters), laser facility operations, and simulations of the resulting photon pressure. We also present the results of experimental laser debris tracking tests. These tests track potential targets of a first technical demonstration and quantify the achievable tracking performance.

Stupl, Jan↗

Nanotube Activities at NASA-Johnson Space Center

Nanotube activities at NASA-Johnson Space Center include production, purification, characterization as well as applications of single wall carbon nanotubes (SWCNTs). A parametric study of the pulsed laser ablation process is recently completed to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Enhancement of production is achieved by rastering the graphite target and by increasing the target surface temperature with a cw laser. In-situ diagnostics during production included time resolved passive emission and laser induced fluorescence from the plume. The improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymer/nanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large Surface area as well as high electrical and thermal conductivity exhibited by SWCNTs. Comparison with existing technologies and possible future improvements in the SWCNT materials sill be presented.

Arepalli, Sivaram↗

Advanced Coating Removal Techniques

An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid nitrogen operations include cutting of both soft and hard materials. While the laser will not cut materials, it can be used to roughen surfaces and to remove other materials from the substrate including oil, grease, and mold. The space program can benefit from several of these applications with the need for precise removal of coatings and other organic compounds in areas adjacent to sensitive space flight hardware. Significant advantages are evident when comparing liquid nitrogen and laser removal operations over current techniques of media blasting and sanding.

Seibert, Jon↗

Trace Element Abundances of Olivine-Hosted Melt Inclusions in Shergottites Northwest Africa 7397 and Robert Massif 04262

Olivine-hosted melt inclusions (MIs) may retain trapped parent magma compositions as well as record progressive differentiation while magmas crystallize and ascend towards the surface [1,2 and references therein]. Major element compositions of the MIs, especially Fe and Mg, can be affected by post-entrapment re-equilibration with their host olivine [1,2]. Therefore, Fe/Mg ratio correction is required to obtain MI bulk compositions following equilibrium with their host olivine. Partition coefficients of most of the trace elements in olivine are very low (i.e. DOL/melt<0.001). Thus, ratios of trace elements of olivine-hosted MIs are unlikely to be affected by post-entrapment re-equilibration and no correction is necessary [2]. Hence, tracking trace element behavior in MIs may constrain the composition of the parent magma and its evolution yielding insights on magma differentiation of shergottites. However, analyzing MIs for chemical compositions is a challenging task due to their low abundances and small sizes. Using a highly sensitive and precise micro-beam technique is essential to examine olivine-hosted MIs in order to measure trace element abundances. For this purpose, laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) is an excellent tool due to its wide range of laser spot sizes (1-150 μm), ability to obtain raster analysis (several mm2) and lower detection limits (0.1 ppb) [3].

Ferdous, J.↗

Studies of High Energy Density Discharge and Laser-Driven Deflagrating Plasma Stagnations

The goal of this proposal is to develop an understanding of the thermalization and mixing of high energy density (HED) interpenetrating and stagnating plasma deflagrations on two different platforms. The first is opposing gas-fed Z-pinch plasma expansions in a facility at Stanford University. The second is the convergence of multiple deflagration fronts generated by inverted corona laser ablations through experiments carried out by the P.I. as part of a larger team at the University of Rochester Laboratory for Laser Energetics. The link between the two platforms is the role played by kinetic effects that impact mixing and the conversion of directed to thermal energy. Such kinetic effects are important because of the relatively high temperatures despite high plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Envisioning an Optimal Network of Space-Based Lasers for Orbital Debris Remediation

The rapid increase in resident space objects, including satellites and orbital debris, poses a significant threat to the safety and sustainability of space missions. This paper explores orbital debris remediation using a network of collaborative space-based lasers, leveraging laser ablation for momentum transfer on debris. A novel delta-v vector analysis framework quantifies the e↵ects of multiple simultaneous laser-to-debris (L2D) engagements by using vector composition of the imparted delta-v vectors. The paper introduces the Concurrent LocationScheduling Problem (CLSP), which optimizes the placement of laser platforms and the scheduling of L2D engagements to maximize debris remediation capacity. Due to the computational complexity of the CLSP, it is decomposed into two sequential subproblems: (1) optimal laser platform locations are determined using the Maximal Covering Location Problem, and (2) a novel integer linear programming-based approach schedules L2D engagements within the network configuration to maximize remediation capacity. Computational experiments are conducted to evaluate the proposed framework’s e↵ectiveness under various mission scenarios, demonstrating key network functions such as collaborative nudging, deorbiting, and just-in-time collision avoidance. A sensitivity analysis further examines how varying the number and distribution of laser platforms a↵ects debris remediation capacity, providing insights into optimizing the performance of space-based laser networks.

David O Williams Rogers↗

Femtosecond temperature measurements of laser-shocked copper deduced from the intensity of the x-ray thermal diffuse scattering

We present 50-fs, single-shot measurements of the x-ray thermal diffuse scattering (TDS) from copper foils that have been shocked via nanosecond laser ablation up to pressures above ∼135 GPa. We hence deduce the x-ray Debye–Waller factor, providing a temperature measurement. The targets were laser-shocked with the DiPOLE 100-X laser at the High Energy Density endstation of the European X-ray Free-Electron Laser. Single x-ray pulses, with a photon energy of 18 keV, were scattered from the samples and recorded on Varex detectors. Despite the targets being highly textured (as evinced by large variations in the elastic scattering) and with such texture changing upon compression, the absolute intensity of the azimuthally averaged inelastic TDS between the Bragg peaks is largely insensitive to these changes, and allowing for both Compton scattering and the low-level scattering from a sacrificial ablator layer provides a reliable measurement of $T/Θ^2_D$, where Θ D is the Debye temperature. We compare our results with the predictions of the SESAME 3336 and LEOS 290 equations of state for copper and find good agreement within experimental errors. We, thus, demonstrate that single-shot temperature measurements of dynamically compressed materials can be made via thermal diffuse scattering of XFEL radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Role of Laser Wavelength on the Early-stage Electron Density Evolution in Laser-Produced Plasma

In this study, a laser-produced plasma (LPP) was generated by focusing fundamental (1064 nm), second (532nm), and fourth (266 nm) harmonic radiation from a 6 ns Nd:YAG laser at a laser intensity of 10 GW/cm2 onto a copper target placed in vacuum. The early time evolution of the plasma between 0-70 ns following laser ablation was then analyzed using Nomarski interferometry. The dependence of plasma properties such as the electron density distribution, plume velocity, and plume morphology on the laser wavelength are discussed.

(280.5395) Plasma Diagnostics, (140.3440) Laser-in↗

Observation of fullerenes (C60-C70) associated with LDEF crater number 31

The presence of fullerenes in and around the LDEF crater number 31 is reported. This crater has a high C level associated with it, and is interpreted as having been produced by the impact of a C-rich micrometeoroid. Fullerenes are large 3-D C structures, among which the species C sub 60 (MW 720) and C sub 70 (MW 840) are preeminent. Fullerenes have several UV absorption bands, hence fullerenes should be detectable using UV laser ionization time-of-flight mass spectrometry. We use a LIMA-2A instrument with pulsed UV laser (266 nm) to search for high mass C species associated with LDEF crater number 31. The mass range was 0 to 1200 amu. Low ablating laser power levels were used (less than or = 5 x 10 exp 7 W/sq. cm); 200 mass spectra were acquired and summed. We observed high mass signals near m/z 720, exhibiting 24 amu separation, which is characteristic of fullerenes. Alkali ion signals were also observed. Little or no C clusters of intermediate mass were observed. We interpret the signals around m/z 720 as fullerenes, mainly C sub 60+ with lower levels of C sub 70+. We propose that the mechanism that produces these signals is resonant multiphoton ionization (REMPI). This selective mechanism explains why low mass C cluster ions are not observed along with the fullerenes, since they have much higher ionization potentials. This finding is unexpected, since up to now the search for fullerenes in extraterrestrial materials has not been successful. We conclude that the fullerenes became associated with crater number 31 in space. Two alternative (and exciting) scenarios are being considered at this time: either the fullerenes were carried by the C-rich projectile that formed crater number 31, or the fullerenes formed upon impact with the LDEF. We show the results of experiments at the ARC Vertical Gun Facility, which may establish some constraints on the origin of the fullerenes.

Radicatidibrozolo, Filippo↗