Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integration of sensors through additive manufacturing leading to increased efficiencies of gas turbines for power generation and propulsion

To realize the full capability of additively manufactured components in complex energy systems, it is imperative to minimize early component failures during development phases and during operation. Traditional field feedback timelines and offline inspection protocols significantly reduce the design-manufacturing iteration times. To address this specific question, the project developed and demonstrated a method for the integration of sensors into complex components through additive manufacturing. The team used gas turbine engines as a platform, which meets the need of both power generation and propulsion and offer opportunities for cost reductions and efficiency increases. The innovation of this intelligent integration of sensors into complex components uniquely customized to address questions of integrity and durability for additively manufactured components. With real-time sensing data from additively manufactured components, turbine manufacturers will realize higher efficiencies, reduced component failures, and a 30-50% acceleration in product deployment of high efficiency gas turbine components due to a faster reduction in component risk assessment under actual operating conditions. This is a transformative shift towards a data-driven design and qualification of additively manufactured gas turbine components. To directly integrate sensors into additively manufactured components with all the complexities of actual hardware, powder bed fusion (direct metal laser sintering) and laser metal deposition technologies was developed. Validation took take place in two university laboratories both of which contain actual engine hardware and closely simulate a gas turbine prior to demonstrating the technology in a turbine development test. Indeed, two major technologies from this research cold impact turbine systems in the near future: (1) higher efficiency materials and designs enabled by additive manufacturing with 50% faster design to manufacturing cycle time, to enable faster time-to-market targets; and (2) integration of sensors into additively manufactured components enabling broad health and condition based prognostics for faster component and engine risk reduction.

33 ADVANCED PROPULSION SYSTEMS↗

Laser Ablation Plasmas and Spectroscopy for Nuclear Applications

The development of measurement methodologies to detect and monitor nuclear-relevant materials remains a consistent and significant interest across the nuclear energy, nonproliferation, safeguards, and forensics communities. Optical spectroscopy of laser-produced plasmas is becoming an increasingly popular diagnostic technique to measure radiological and nuclear materials in the field without sample preparation, where current capabilities encompass the standoff, isotopically resolved and phase-identifiable (e.g., UO and UO[Formula: see text]) detection of elements across the periodic table. These methods rely on the process of laser ablation (LA), where a high-powered pulsed laser is used to excite a sample (solid, liquid, or gas) into a luminous microplasma that rapidly undergoes de-excitation through the emission of electromagnetic radiation, which serves as a spectroscopic fingerprint for that sample. This review focuses on LA plasmas and spectroscopy for nuclear applications, covering topics from the wide-area environmental sampling and atmospheric sensing of radionuclides to recent implementations of multivariate machine learning methods that work to enable the real-time analysis of spectrochemical measurements with an emphasis on fundamental research and development activities over the past two decades. Background on the physical breakdown mechanisms and interactions of matter with nanosecond and ultrafast laser pulses that lead to the generation of laser-produced microplasmas is provided, followed by a description of the transient spatiotemporal plasma conditions that control the behavior of spectroscopic signatures recorded by analytical methods in atomic and molecular spectroscopy. High-temperature chemical and thermodynamic processes governing reactive LA plasmas are also examined alongside investigations into the condensation pathways of the plasma, which are believed to serve as chemical surrogates for fallout particles formed in nuclear fireballs. Laser-supported absorption waves and laser-induced shockwaves that accompany LA plasmas are also discussed, which could provide insights into atmospheric ionization phenomena from strong shocks following nuclear detonations. Furthermore, the standoff detection of trace radioactive aerosols and fission gases is reviewed in the context of monitoring atmospheric radiation plumes and off-gas streams of molten salt reactors. Finally, concluding remarks will present future outlooks on the role of LA plasma spectroscopy in the nuclear community.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Combined Coherent Manipulation and Single-Shot Measurement of an Electron Spin in a Quantum Dot (Final Technical Report)

Semiconductor quantum dots (QDs) are promising candidates to act as single-photon sources and/or quantum bits in future optical quantum information applications. Their excellent optical properties such as high brightness, single-photon purity, and narrow linewidth have potential utility in many areas. One challenge is to control the energy levels of the QD without using a magnetic field. The AC Stark effect offers the opportunity to do this. We have demonstrated record-large AC Stark shifts of the energy states of a single charged QD. We showed that the shifts can be applied in a spin-selective manner by controlling the polarization of the laser producing the AC Stark effect. In order to characterize the effect, we developed a novel spectral filtering scheme to discriminate the high-power AC Stark laser from the QD fluorescence. We also developed a compact, low-cost, homemade polarimeter to help control the polarization of the AC Stark laser, which enabled the spin selectivity of the AC Stark effect. With the practical capabilities thus developed, we learned that the spin-selective AC Stark effect causes electron spin pumping, which in turn causes nuclear spin pumping via the hyperfine interaction. The nuclear spin pumping causes a mean field Zeeman interaction between the nuclear spin ensemble and the electron trapped in the QD, resulting in the so-called Overhauser shift. The magnitude of the Overhauser shift and the measured linewidth of the QD’s optical transitions enabled characterization of the mean nuclear spin polarization and fluctuations. The potentially rapid (ns-scale) control of the QD energy levels and nuclear spin polarization will enable measurements of electron and nuclear spin polarization in the absence of any real magnetic field, which is a completely unique capability. The ability to rapidly apply a spin-selective AC Stark effect in the presence of a weak real magnetic field will allow control of the polarization selection rules of the transitions, enabling all single-qubit operations on the electron spin, i.e., initialization, coherent manipulation, and quantum non-demolition measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Control of laser-beam spatial distribution for correcting the shape and refraction of eye cornea

The results of calculation and development of a device aimed at forming a laser beam with an annular intensity distribution and spatial mode homogenisation, as well as approbation of this device for biological phantoms and eyes in ex vivo experiments with laser non-ablative correction of the cornea profile, are presented. The radiation intensities and thermal field distributions on the surfaces of a phantom and isolated rabbit’s eye are investigated. The absence of significant heating in the central region of eye is confirmed. It is shown that this device can be used for laser impact in order to change symmetrically eye’s refraction. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nuclear Excitation and Fission Studies with Short Pulsed Laser-Driven High Energy Gamma Rays

We propose the development of a platform to study photon excitation of high Z nuclei utilizing a high energy (70 J) short pulsed (500 fs) laser to drive > 5 MeV γ-radiation. The laser beam will be focused onto a specially prepared foam or corrugated conveying target, where it generates relativistic MeV electrons via ponderomotive and wake-field acceleration mechanisms. γ-emission is produced in the form of bremsstrahlung in the same target or in a separated high-Z γ-production target hit by the accelerated MeV electrons. The high energy γ-rays will be utilized to provide nuclear state excitation in the short time domain. The γ platform will allow to investigate photo fission of high Z target material positioned in an auxiliary target chamber in the γ-ray beam path via the established gas transport scheme. The photo fission yield will provide furthermore diagnostic information on the produced γ-yield. In addition, γ-spectroscopy will be used to identify γ-lines for the diagnostic of the excited state population of high Z target nuclei. This research capability is relevant to the understanding of how nuclear excitation effects fission, in relevance to recent astrophysical observations on element nucleosynthesis. These processes involve neutron-rich fragments and processes such as fission recycling (e. g. in neutron stars outer crusts).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Triple oxygen and hydrogen stable isotope composition of water in Murchison carbonaceous chondrite accessed by thermogravimetry-enabled laser spectroscopy

For this work, we have developed the capability to measure 17 O/ 16 O in H 2 O and OH - of hydrous minerals by a technique using thermogravimetric analysis coupled with isotope ratio infrared spectroscopy (TGA-IRIS) on a suite of liquid water standards, terrestrial mineral standards, multi-mineral synthetic mixtures of terrestrial samples, and Murchison carbonaceous chondrite. This 17 O/ 16 O analytical capability is combined with the previously developed TGA-IRIS capability of 18 O/ 16 O, which enables us to calculate Δ `17 O values. Additionally, we have made 2 H/ 1 H measurements by TGA-IRIS on the suite of materials. Analyses of 328 standard water samples sealed into silver tubes (0.25 μL, 174 VSMOW and 154 GISP) analyzed over the course of three years yielded δ 18 O values by TGA-IRIS with precision of ±0.30 ‰, δ 17 O of ±0.24 ‰, Δ `17 O of ±0.126 ‰, and δ 2 H ± 7.5 ‰ (± 1 Std. Dev.). TGA-IRIS analyses of a suite of hydrous minerals (oxy-hydroxide, mica, serpentines, sulfide, phyllosillicates) yields similar precision. TGA-IRIS analyses of the CM2 carbonaceous chondrite Murchison resulted in δ 18 O, δ 17 O, Δ `17 O, and δ 2 H values of the H 2 O and/or OH - from its hydrous minerals. Δ `17 O values of Murchison H 2 O range from 1.034 ‰ at 350 °C, to -0.368 ‰ at 650 °C, to -1.75 ‰ at 850 °C. TGA-IRIS can generate Δ `17 O values of H 2 O and/or OH - in hydrous materials that are well within the precision needed for the analysis of meteoritic samples, as well as samples returned from asteroids, such as Ryugu and Bennu.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nanoscale ultrafast lattice modulation with a free-electron laser

Ultrafast optical laser-based techniques have enabled the probing of atomistic processes at their intrinsic temporal scales with femto- and attosecond resolution. However, the long wavelengths of optical lasers have prevented their interrogation and manipulation with nanoscale spatial specificity. Advances in hard X-ray free-electron lasers have enabled progress in developing X-ray transient-grating spectroscopy, a technique that aims to coherently control elementary excitations with nanoscale X-ray standing waves. Thus far, the realization of this technique at the nanoscale has been a challenge. Here we demonstrate X-ray transient-grating spectroscopy with spatial periods of the order of 10 nm via the subfemtosecond synchronization of two hard X-ray pump pulses at a precisely controlled crossing angle. This creates a thermal grating and preferentially excites coherent longitudinal acoustic phonon modes with the transient-grating wavevector. On probing with a third, variably delayed, X-ray pulse with the same photon energy, time-and-wavevector-resolved measurements of the modulation of the induced scattering intensity provide evidence of ballistic thermal transport at nanometre scales. Finally, these results highlight the potential of X-ray transient gratings as a powerful platform for studying nanoscale transport in condensed matter and the coherent control of nanoscale dynamics.

nonlinear optics↗

Nanosecond Laser Drying in Wafer Foundries for Significant Energy Efficiency Improvement

Surface drying is a critical process in microelectronics wafer fabrication. In order to reduce and eliminate watermarks, many surface drying processes have been studied and used. Most of the wafer foundries currently use drying processes based on Isopropyl Alcohol (IPA), which causes serious safety (fire), health, environmental, and energy efficiency issues. The long-term goal of this project is to develop a fast, effective, chemical-free, and extremely energy efficient wafer drying technology that employs nanosecond laser-induced sub-surface evaporation and explosion. The objectives of this project are to 1) experimentally develop and verify the laser surface drying method, explore and identify how and to what extent various physical parameters influence the drying efficiency and effectiveness; and 2) understand and optimize the underlying thermodynamics in the proposed laser surface drying, including micro/nanoscale sub-surface superheating, evaporation, explosion, and photo/thermochemical bond breaking via atomistic modeling and experimental characterization. Toward these objectives, five tasks have been accomplished successfully, including 1) develop in-lab laser surface drying setup and study the effect of varied laser parameters, 2) use multiscale hybrid-modeling to study and understand the physics of water behavior during drying toward process optimization, 3) investigate the effect of drying conditions on the drying effectiveness, 4) develop a large-scale laser drying scanning system with automatic scanning, and 5) conduct large-scale simulation to study the effect of dopant level and develop strategies for system development toward industry deployment.

42 ENGINEERING↗

Understanding non-stochiometric deposition of multi-principal elemental NiCoCr thin films

Multi-principal elemental NiCoCr thin films with compositional flexibility have potential applications as a thermal barrier, corrosion-resistant coatings, and functional energy materials. In this study, the non-stochiometric multi-principal element alloy thin film formation behavior from an equiatomic ablation target of NiCoCr using pulsed laser deposition has been reported. Here, the effect of varying laser fluence on compositions of constituent elements in the NiCoCr thin films is systematically investigated. The increase in laser fluence typically increases the likelihood of acquiring undesirable particulates in thin films. Therefore, to maintain the film quality the laser fluences are adjusted within the range of 1.3–3.3 J·cm -2 , while the film thicknesses are kept constant at ~30 nm. Results show that the constituent elements are well-distributed in the formed NiCoCr thin films, however, having average atomic percentages of Ni and Cr twice as high as Co irrespective of the equiatomic composition of individual elements in the ablation target. This stochiometric alteration in the as-deposited thin films is governed by the rate of ablation and subsequent evaporation of each element, which is facilitated by the optical properties and vapor pressure of individual constituent elements. Additionally, electron energy-loss spectroscopy and x-ray absorption spectroscopy analysis reveal that the thin films have partially oxidized, with the Cr oxidation contributing the most to the O-K edge in comparison to Ni and Co. Finally, this study presents a laser-assisted pathway for fabricating compositionally flexible NiCoCr thin films and develops an understanding of the non-equilibrium laser-material interactions and how the intrinsic properties of constituent elements affect the stoichiometric flow of materials from the target to the final film deposition.

36 MATERIALS SCIENCE↗

Improved modeling of the solid-to-plasma transition of polystyrene ablator for laser direct-drive inertial confinement fusion hydrocodes

We report that the target performance of laser direct-drive inertial confinement fusion (ICF) can be limited by the development of hydrodynamic instabilities resulting from the nonhomegeneous laser absorption at the target surface, i.e., the laser imprint on the ablator. To understand and describe the formation of these instabilities, the early ablator evolution during the laser irradiation should be considered. In this work, an improved modeling of the solid-to-plasma transition of a polystyrene ablator for laser direct-drive ICF is proposed. This model is devoted to be implemented in hydrocodes dedicated to ICF which generally assume an initial plasma state. The present approach consists of the two-temperature model coupled to the electron, ion and neutral dynamics including the chemical fragmentation of polystyrene. The solid-to-plasma transition is shown to significantly influence the temporal evolution of both free electron density and temperatures, which can lead to different shock formation and propagation compared with an initial plasma state. The influence of the solid-to-plasma transition on the shock dynamics is evidenced by considering the scaling law of the pressure with respect to the laser intensity. The ablator transition is shown to modify the scaling law exponent compared with an initial plasma state.

36 MATERIALS SCIENCE↗

Optically pumped polarized 3 He ++ ion source development for RHIC/EIC

The proposed polarized 3 He ++ acceleration in RHIC and the future Electron-Ion Collider will require about 2×10 11 ions in the source pulse. A new technique had been proposed for production of high intensity polarized 3 He ++ ion beams. It is based on ionization and accumulation of the 3 He gas (polarized by metastability-exchange optical pumping and in the 5T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel 3 He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized 3 He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3–5 T field has been developed. The 3 He polarization 80–85% (and sufficiently long ~30 min relaxation time) was obtained in the “open” cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and 3 He 4 He absolute nuclear polarimeter at 6 MeV 3 He ++ beam energy is also presented here in this work.

43 PARTICLE ACCELERATORS↗

X-ray multi-probe data acquisition: A novel technique for laser pump x-ray transient absorption spectroscopy

We report the development and implementation of a novel data acquisition (DAQ) technique for synchrotron-based laser pump X-ray Transient Absorption (XTA) spectroscopy, called X-ray Multi-Probe DAQ (XMP DAQ). This technique utilizes high performance analog to digital converters and home-built software to efficiently measure and process the XTA signal from all x-ray pulses between laser excitations. XMP DAQ generates a set of time resolved x-ray absorption spectra at thousands of different pump–probe time delays simultaneously. Two distinct XMP DAQ schemes are deployed to accommodate different synchrotron storage ring filling patterns. Current Integration (CI) DAQ is a quasi-analog technique that implements a fitting procedure to extract the time resolved absorption intensity from the averaged fluorescence detector response. The fitting procedure eliminates issues associated with small drifts in the voltage baseline and greatly enhances the accuracy of the technique. Photon Counting (PC) DAQ is a binary technique that uses a time resolved histogram to calculate the XTA spectrum. While PC DAQ is suited to measure XTA data with closely spaced x-ray pulses (~10 ns) and a low count rate (<1 detected photon/pulse), CI DAQ works best for widely spaced pulses (tens of ns or greater) with a high count rate (>1 detected photon/pulse). XMP DAQ produces a two-dimensional XTA dataset, enabling efficient quantitative analysis of photophysical and photochemical processes from the sub-nanosecond timescale to 100 μs and longer.

47 OTHER INSTRUMENTATION↗

457-nm radiation source based on a diode laser for precision spectroscopy of magnesium atoms

We report on the development of a highly stable source of 457-nm radiation based on a diode laser and a tapered amplifier operating in a double-pass scheme. The diode laser frequency was stabilised by a high-Q reference Fabry – Perot interferometer and doubled in a PPSLT nonlinear crystal placed in an enhancement cavity. At a maximum output power of 200 mW at a wavelength of 457 nm, the laser linewidth was less than 5 kHz. The radiation source operation was demonstrated in experiments on precision spectroscopy of cold magnesium atoms in a magneto-optical trap. (lasers)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical model of the stimulated forward Brillouin scattering driven by a randomized laser beam in plasma

The modeling of a spatially incoherent laser beam remains a central problem of the parametric instabilities in the context of inertial confinement fusion. This letter gives a simplified and comprehensive overview of the recent analytical developments regarding the modeling of these laser beams and a comparison with a dedicated experiment. Our model accounts for the first time for the statistical standard deviation of the gain and accurately captures the entanglement between wave mixing processes and the speckle correlations thus resolving the longstanding contradictions between the random phase approximation and the model of independent speckles. It is successfully compared to a recent laser beam spray experiment and the associated paraxial simulations, demonstrating that backscattering predictions require accounting for the beam spray. Furthermore, our framework thus provides a way to evaluate and guide the analysis of parametric instabilities in high laser energy experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A formaldehyde and nitrogen dioxide toxics monitor for environmental justice

DOE’s Integrated Field Laboratories (IFLs) require a vast array of measurements to measure urban air quality. Nitrogen dioxide (NO2) and formaldehyde (HCHO) are ubiquitous pollutants with numerous sources, most notably vehicle exhaust. High-spatial density measurements are critical to understanding how certain neighborhoods are more adversely impacted by pollutants. This report describes the results of a Phase I SBIR project to develop and demonstrate a rapid, affordable, low-power monitor to provide high spatial resolution mobile measurements of formaldehyde and nitrogen dioxide at street-level, where people live and walk. The spatial density will be achieved via rapid measurements on a mobile platform. This sensor will quantify spatial disparities in cities of the toxics, HCHO and NO2, as well as carbon monoxide and carbon dioxide for better source identification. These species are detected in the mid infrared by laser absorption spectroscopy, and fiberoptics are used. Tasks accomplished include identification and testing of the appropriate spectroscopic regions; coupling of laser light into a fiberoptic system; development of software to control miniature electronics to scan and control two lasers simultaneously; coupling of the mid infrared fiber into a multipass cell for enhanced pathlength and sensitivity; characterization of sources of instrument noise; and design work for a Phase II prototype.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spatially Resolved Mass Spectrometry at the Single Cell: Recent Innovations in Proteomics and Metabolomics

Biological systems are composed of heterogeneous populations of cells that intercommunicate to form a functional living tissue. Biological function varies greatly across populations of cells, as each single cell has a unique transcriptome, proteome, and metabolome that translates to functional differences within single species and across kingdoms. Over the past decade, substantial advancements in our ability to characterize omic profiles on a single cell level have occurred, including in multiple spectroscopic and mass spectrometry (MS)-based techniques. Of these technologies, spatially resolved mass spectrometry approaches, including mass spectrometry imaging (MSI), have shown the most progress for single cell proteomics and metabolomics. For example, reporter-based methods using heavy metal tags have allowed for targeted MS investigation of the proteome at the subcellular level, and development of technologies such as laser ablation electrospray ionization mass spectrometry (LAESI-MS) now mean that dynamic metabolomics can be performed in situ. In this Perspective, we showcase advancements in single cell spatial metabolomics and proteomics over the past decade and highlight important aspects related to high-throughput screening, data analysis, and more which are vital to the success of achieving proteomic and metabolomic profiling at the single cell scale. Finally, using this broad literature summary, we provide a perspective on how the next decade may unfold in the area of single cell MS-based proteomics and metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Characterization of a mock up nuclear waste package using energy resolved MeV neutron analysis

Reliable radiographic methods for characterizing nuclear waste packages non-destructively (without the need to open containers) have the potential to significantly contribute to safe handling and future disposal options, particularly for legacy waste of unknown content. Due to required shielding of waste containers and the need to characterize materials consisting of light elements, X-ray methods are not suitable. Here, energy-resolved MeV neutron radiography is demonstrated as a first-of-its-kind application for non-destructive and remote examination of mock up nuclear waste packages from a safe position using time-of-flight techniques enabled by a novel event-mode imaging detector system. Energy-resolved neutron transmission spectra were measured spatially, permitting the detection of analogue materials to actual nuclear waste such as water, melamine, and ion exchange resin within a 2.54 cm wall thickness steel pipe. The results demonstrate the capability to locate the materials through this wall thickness by radiography and tomographic reconstruction, revealing detailed 3D distributions and structural anomalies. The method effectively detects residual water in ion exchange resin, highlighting its sensitivity to moisture content, a crucial parameter for nuclear waste characterization. Monte Carlo simulations are in agreement with the experimental findings, providing a pathway to simulate waste forms more difficult to tackle experimentally. This work paves the way to apply sub-nanosecond intense MeV neutron sources, such as laser-driven neutron sources under development, to nuclear waste characterization.

36 MATERIALS SCIENCE↗