Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Megahertz single-particle imaging at the European XFEL

The emergence of high repetition-rate X-ray free-electron lasers (XFELs) powered by superconducting accelerator technology enables the measurement of significantly more experimental data per day than was previously possible. The European XFEL is expected to provide 27,000 pulses per second, over two orders of magnitude more than any other XFEL. The increased pulse rate is a key enabling factor for single-particle X-ray diffractive imaging, which relies on averaging the weak diffraction signal from single biological particles. Taking full advantage of this new capability requires that all experimental steps, from sample preparation and delivery to the acquisition of diffraction patterns, are compatible with the increased pulse repetition rate. Here, we show that single-particle imaging can be performed using X-ray pulses at megahertz repetition rates. The results obtained pave the way towards exploiting high repetition-rate X-ray free-electron lasers for single-particle imaging at their full repetition rate.

36 MATERIALS SCIENCE↗

Thermal transport in nanoporous holey silicon membranes investigated with optically induced transient thermal gratings

In this study, we use transient thermal gratings—a non-contact, laser-based thermal metrology technique with intrinsically high accuracy—to investigate room-temperature phonon-mediated thermal transport in two nanoporous holey silicon membranes with limiting dimensions of 120 nm and 250 nm, respectively. We compare the experimental results with ab initio calculations of phonon-mediated thermal transport according to the phonon Boltzmann transport equation (BTE) using two different computational techniques. We find that the calculations conducted within the Casimir framework, i.e., based on the BTE with the bulk phonon dispersion and diffuse scattering from surfaces, are in quantitative agreement with the experimental data and thus conclude that this framework is adequate for describing phonon-mediated thermal transport in silicon nanostructures with feature sizes of the order of 100 nm.

Duncan, Ryan A. (ORCID:0000000328318099)↗

Coupling of a single tin-vacancy center to a photonic crystal cavity in diamond

In this work, we demonstrate optical coupling between a single tin-vacancy (SnV) center in diamond and a free-standing photonic crystal nanobeam cavity. The cavities are fabricated using quasi-isotropic etching and feature experimentally measured quality factors as high as ~11000. We investigate the dependence of a single SnV center's emission by controlling the cavity wavelength using a laser-induced gas desorption technique. Under resonance conditions, we observe an intensity enhancement of the SnV emission by a factor of 12 and a 16-fold reduction of the SnV lifetime. Based on the large enhancement of the SnV emission rate inside the cavity, we estimate the Purcell factor for the SnV zero-phonon line to be 37 and the coupling efficiency of the SnV center to the cavity, the β factor, to be 95%. Our work paves the way for the realization of quantum photonic devices and systems based on efficient photonic interfaces using the SnV color center in diamond.

42 ENGINEERING↗

Large-volume CdZnTe bar detectors characterized by laser-induced transient currents

In this work, we studied the free-carrier transport properties and space-charge formation/polarization in a CdZnTe bar-shaped radiation detector using the Laser-Induced Transient Current technique. We found out that a steady-state space charge ranging from 8 x 10 8 to 2.1 x 10 9 cm -3 is formed throughout the detector at about 0.5 s following biasing. The measured current waveforms were modeled by Monte Carlo simulations after taking into account the electric and weighting fields inside the detector and shielding box. Modeling of the unpolarized waveforms revealed an exceptionally high electron mobility-lifetime product μ e τ e ≥0.095cm 2 V -1 . The observed formation of positive space charge in the biased detector and linear scaling of the current waveform shapes on applied bias revealed that the detector polarization is attributed to carrier injection at the anode. In conclusion, measurements in pulsed and DC bias in modified electrode geometry proved the surface-charge formation.

47 OTHER INSTRUMENTATION↗

The shard test and nanoporomechanics reverse classical paradigm of cement hydration being contractive

Le Chatelier in 1887 and Powers in 1947 demonstrated that the volume of nanoscale C-S-H (calcium silicate hydrate) particles formed during hydration is smaller than the combined volume of the reactants—the anhydrous Portland cement and water. Hydration has thus been considered as contractive. An experiment shows that the opposite is true above the nanoscale. The porous skeleton of cement paste expands as the growing C-S-H particles push each other apart, similar to crystal growth pressure. This is significant for high-performance concretes (HPC) with low water-cement ratios (w/c ≤ 0.4), where chemical self-desiccation lowers pore relative humidity by 40%, compared to just 1% in traditional concretes (w/c ≈ 0.5). Standard American Society for Testing and Materials (ASTM) C1608 tests, using 10 mm thick water-immersed specimens, show large shrinkage because the half-time of water ingress is many decades, unable to offset shrinkage-causing self-desiccation. The present experiment, using a laser microscopy-topography technique, proves the opposite—expansion, evidenced by measuring the length changes of water-immersed HPC shards 0.5 mm thick in which the diffusion halftime, only about one hour, allows continuous resaturation of pores, canceling self-desiccation. The faster diffusion (halftime of one hour) enables continuous pore resaturation, preventing shrinkage. When sealed with paraffin oil, the shards self-desiccate and shrink. These findings align with studies since 2015, showing that models excluding hydration expansion cannot fit test data across various specimen sizes and sealing conditions. The results suggest that standardized ASTM tests for the so-called chemical shrinkage in modern concretes with very low water-cement ratios are misleading and need revision.

Science & Technology - Other Topics↗

Ultrahigh strength and plasticity in laser rapid solidified Al–Si nanoscale eutectics

As-cast Al–20wt.% Si alloys were processed via laser rapid solidification (LRS) techniques to create eutectic microstructures with nanoscale interconnected, nanotwinned Si fibers. LRS morphologies exhibit higher flow stress, exceeding 800 MPa and uniform plastic deformation above 20% compared to as-cast alloy that fractures at strains below 8% at flow strength of approximately 200 MPa. The strengthening mechanisms of LRS morphologies are interpreted in terms of the interfacial constraints: increase in yield strength as well as strain hardening rate due to nanoscale confined slip in fibrous Al–Si eutectic, and load transfer and eventual plasticity in the nanoscale Si fibers.

36 MATERIALS SCIENCE↗

Measurements of time and spatial resolution of AC-LGADs with different designs

AC-LGAD sensors are prime candidates for fast and precise measurement of charged particles in a variety of applications. In a fine-pitched pixel or strip AC-LGAD sensor, the signal generated by the passage of a particle is not localized in a limited volume in the sensor, but is shared among multiple electrodes. This signal sharing characteristic allows us to improve the spatial resolution of AC-LGAD sensors beyond the capabilities of common silicon trackers. Since the magnitude of the shared signal depends on the distance between the pixels or strips and the point of passage of the particle, signal sharing is strongly influenced by the geometry of the sensor. The electrode pitch and gap size as well as the shape can be fine tuned to maximize the space resolution, while keeping the detector granularity and the number of channels to be read out under control. Prototypes of AC-LGAD sensors produced at the Brookhaven National Laboratory covering a variety of possible geometries have been studied via Transient Current Technique using an infrared laser, and the signal sharing, spatial resolution, and time resolution of the different topologies have been measured. These results have been compared with measurements performed in test-beams with 120 GeV protons at the Fermilab Test Beam Facility. A time resolution of ~30 ps can be achieved using AC-LGAD sensors with a thickness of 50 μm, compatible to that of standard DC-coupled LGADs, while presenting a far superior spatial resolution. Finally, this combination of high precision, fast timing capabilities, and low material budget makes AC-LGADs an ideal choice for a truly 4D detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A mesoscopic digital twin that bridges length and time scales for control of additively manufactured metal microstructures

We present our recent development of an integrated mesoscale digital twin (DT) framework for relating processing conditions, microstructures, and mechanical responses of additively manufactured (AM) metals. In particular, focusing on the laser powder bed fusion technique, we describe how individual modeling and simulation capabilities are coupled to investigate and control AM microstructural features at multiple length and time scales. We review our prior case studies that demonstrate the integrated modeling schemes, in which high-fidelity melt pool dynamics simulations provide accurate local thermal profiles and histories to subsequent AM microstructure simulations. We also report our new mechanical response modeling results for predicted AM microstructures. In addition, we illustrate how our DT framework has been validated through modeling–experiment integration, as well as how it has been practically utilized to guide and analyze AM experiments. Finally, we share our perspectives on future directions of further development of the DT framework for more efficient, accurate predictions and wider ranges of applications.

36 MATERIALS SCIENCE↗

Experimental Generation of Extreme Electron Beams for Advanced Accelerator Applications

In this Letter, we report on the experimental generation of high energy (10 GeV), ultrashort (femtosecond-duration), ultrahigh current (∼ 0.1 MA), petawatt peak power electron beams in a particle accelerator. These extreme beams enable the exploration of a new frontier of high-intensity beam-light and beam-matter interactions broadly relevant across fields ranging from laboratory astrophysics to strong field quantum electrodynamics and ultrafast quantum chemistry. We demonstrate our ability to generate and control the properties of these electron beams by means of a laser-electron beam shaping technique. In conclusion, this experimental demonstration opens the door to on-the-fly customization of extreme beam current profiles for desired experiments and is poised to benefit a broad swath of cross-cutting applications of relativistic electron beams.

43 PARTICLE ACCELERATORS↗

XtalCAMP: a comprehensive program for the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data

XtalCAMP is a software package based on the MATLAB platform, which is suitable for, but not limited to, the analysis and visualization of scanning Laue X-ray micro-/nanodiffraction data. The main objective of the software is to provide complementary functionalities to the Laue indexing software packages used at several synchrotron beamlines. Here, the graphical user interfaces allow the easy analysis of characteristic microstructure features, including real-time intensity mapping for a quick examination of phase, grain and defect distribution, 2D color-coded mapping of microstructural properties from the output of other Laue indexing software, crystal orientation visualization, grain boundary characterization based on orientation/misorientation calculation, principal strain/stress analysis, and strain ellipsoid representation, as well as a series of additional toolkits. As an example, XtalCAMP is applied to the microstructural investigation of a solution-heat-treated Ni-based superalloy manufactured using a laser 3D-printing technique, and a deformed natural quartzite from Val Bregaglia in the Central Alps.

36 MATERIALS SCIENCE↗

Measuring an ultrashort, ultraviolet pulse in a slowly responding, absorbing medium

Frequency-resolved optical gating (FROG) is a common technique for measuring ultrashort laser pulses using an instantaneous, nonlinear-optical interaction as a fast time-gate to measure the pulse intensity and phase. But at high frequencies, materials are often absorbing and it is not always possible to find a medium with a fast nonlinear-optical response. Here we show that an ultrashort, ultraviolet (UV) pulse can be measured in a strongly absorbing medium, using the absorption as the nonlinear-optical time-gate. To do this, we build on our recent implementation of FROG, known as induced-grating cross-correlation FROG (IG XFROG), where an unknown, higher-frequency pulse creates a transient grating that is probed with a lower-frequency, more easily detectable reference pulse. We demonstrate this with an 800 nm reference pulse to characterize 400 nm or 267 nm pulses using ZnS as the nonlinear-optical medium, which is absorptive at and below 400 nm. By scanning the delay between the two UV pulses which create the transient grating, we show that the phase-sensitive instantaneous four-wave-mixing contribution to the nonlinear signal field can be detected and separated from the slower, incoherent part of the response. Measuring a spectrally-resolved cross-correlation in this way and then applying a simple model for the response of the medium, we show that a modified generalized projections (GP) phase-retrieval algorithm can be used to extract the pulse amplitude and phase. We test this approach by measuring chirped UV pulses centered at 400 nm and 267 nm. Since interband absorption (or even photoionization) is not strongly wavelength-dependent, we expect IG XFROG to be applicable deeper into the UV.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Physics Division Strategic Plan Fiscal Years 2020-2024

The vision of the Physics Division (PHY) at Argonne National Laboratory is to continue enhancing its role as a world-leading institution in basic nuclear physics research and its applications. Key to this vision is for PHY to continue to safely and effectively operate and evolve the capabilities of the Argonne Tandem Linac Accelerator System (ATLAS) facility to best serve its users. ATLAS is the Department of Energy (DOE) accelerator facility for low-energy nuclear physics research. The research carried out by PHY covers many themes in contemporary science but can be distilled into five areas of focus. These themes are interconnected, with continuously evolving synergies between the various groups and facilities in PHY and the broader Laboratory. This five-year strategic plan serves to illustrate our current capabilities and new directions related to these five areas of focus (ATLAS also develops an independent strategic plan): Accelerator research and design. The goal of this theme is to design, fabricate, test, and implement novel accelerator systems, with a focus on high-intensity ion and electron systems. These R&D activities have led to enhancements in the ATLAS accelerator system. Among others, the division’s accelerator systems are in use or planned for use at Fermilab, the Advanced Photon Source, and in a broad variety of applications at the Facility for Rare Isotope Beams (FRIB). Atom trapping and fundamental symmetries. The goal of this theme is to explore and exploit the uses of advanced laser cooling and trapping techniques to manipulate atoms. There are three main areas of focus. First is in the application of the atom trap trace analysis (ATTA) technique for age determination of groundwater and ice by using radio-krypton dating. The next two trapping-based programs involve tests of fundamental symmetries in nature: the cooling and trapping of radium-225 with the aim of determining limits on an observation of its electric dipole moment and precision measurements of the beta decay properties of helium-6 to set limits on the tensor coupling constant. This is complemented by measurements of similar properties in lithium-8 and boron-8. Nuclear astrophysics. The goal of this theme is to enhance our understanding of how elements are created in the universe via explosive nucleosynthesis and how stars evolve. To meet the challenges of this theme, many of the capabilities of ATLAS are being enhanced, including the development of new beams through a new in-flight separator (RAISOR) and the anticipated neutron-generator upgrade of the Californium Rare Isotope Breeder Upgrade facility (nuCARIBU). These are coupled to state-of-the-art instruments such as the Canadian Penning Trap, Helical Orbit Spectrometer, Gammasphere, GRETINA, Multi-Sampling Ionization Chamber, the Fragment Mass Analyzer, and Argonne Gas-filled Fragment Analyzer, and a new low-background experimental area for decay studies. Nuclear structure. The goal of this theme is to understand the structure of nuclei, both stable and radioactive, in terms of single-particle properties, their shapes, and the dynamics governing reactions between them. These include questions such as what are the limits of nuclear stability and what are the properties of super heavy nuclei. As with the nuclear astrophysics theme, the capabilities of ATLAS, guided by the ATLAS user community, are continuously being enhanced to this end. The Division has strategic initiatives to play a leading role in the development of instrumentation and research programs at the FRIB. Quantum chromodynamics (QCD) and hadron physics. The goal of this theme is to lead major research programs focused on revealing the quark and gluon structure of protons, neutrons, nuclei, and short-lived mesons and baryons. These involve major programs at Jefferson Lab, Fermilab, and smaller facilities. They are complemented by theoretical endeavors centered on the question of how hadrons and their properties emerge from QCD. Out of these activities arise strategic initiatives to play a major role in the forthcoming Electron-Ion Collider (EIC).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Nanosecond Repetitively Pulsed (NRP) Plasmas: Relationship Between Induced Flow and Plasma Characteristics at Atmospheric Pressure (Final Technical Report)

The local flow fields induced by plasma discharges at atmospheric pressure can play a critical role in aerodynamic flow and combustion control and have significant implications for plasma-based technologies in medicine and environmental engineering. However, the coupling between the plasma characteristics, the geometry and the induced flow field is not well understood. The primary goal of this work is to determine the relationship between the plasma characteristics and the induced flow field for nanosecond pulsed discharges at atmospheric pressure. A comprehensive experimental investigation of plasmas produced by nanosecond high-voltage pulses in a pin-to-pin electrode configuration was conducted, employing several measurement techniques including microwave and laser Rayleigh scattering, optical emission spectroscopy, and high-speed imaging. The flow field induced by the nanosecond plasma was measured and characterized using measurements of the velocity (particle image velocimetry) and density (background oriented schlieren) with unprecedented spatiotemporal resolution. The experimental measurements were complemented by development of a one-dimensional model of the plasma discharge and a high-fidelity computational fluid dynamics (CFD) simulation of the subsequent plasma-induced flow field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Bunch Length Measurements at the CEBAF Injector at 130 kV

In this work, we investigated the evolution in bunch length of beams through the CEBAF injector for 8?770 fC charge per bunch. Using the software General Particle Tracer (GPT), we have simulated beams through the beamline of the CEBAF injector to predict bunch lengths at the location of a beam chopper for comparison with measurements and to validate the model. We performed these simulations with the existing injector using a 130 kV gun voltage. The mea- surements have been done using chopper phase scanning technique for two injector laser drive frequencies 499 MHz and 249.5 MHz. Acknowledgement This material is based upon work supported by the U.S. Department of Energy, Office of Science, Office of Nuclear Physics under contract DE-AC05-06OR23177.

Pokharel, S.↗

Measurement of Magnetic Field using Doppler-Free Saturation Spectroscopy (DFSS) in C-2W FRC Plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on implementing an existing mobile Doppler-free saturation spectroscopy (DFSS) diagnostic to determine the direction of the equilibrium magnetic field within TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening and reveal the Zeeman fine structure of the target emission lines. The collaboration involved the use of ORNL’s recently constructed mobile DFSS diagnostic. The DFSS diagnostic was shipped and installed on C- 2W in February 2023. TAE’s expertise was used to design and construct the mechanic support structures required to mount the optical hardware on C-2W. Additionally TAE provide critical input to minimize the noise imposed on the DFSS signal by vibrations of the mechanic support structure during operations. DFSS data was obtained for over 500 C-2W shots and will continue until the expiration of this CRADA on September 30 th 2023. Over the course of this work, significant progress was made to maximize the signal to noise (SNR) ratio. Analysis of recently acquired data is on-going, however, initial indications are highly suggestive that a DFSS signal above background has been successfully acquired in C-2W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal energy storage devices, systems, and methods

Methods, systems, and device for thermal energy storage are provided. For example, some embodiments include a thermal energy storage device that may include: a first casing wall; a second casing wall; and/or multiple support structures located between the first casing wall and the second casing wall. The multiple support structures may provide continuous thermal paths and/or continuous mechanical paths between the first casing wall and the second casing wall. The thermal energy storage device may be fabricated utilizing an additive manufacturing technique, such as direct laser metal sintering. Some embodiments may be manufactured utilizing printed metals, such as an aluminum alloy. In some embodiments, a phase-change material is charged between the first casing wall and the second casing wall. The phase-change material may include paraffin.

Isaacs, Steven↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗

Development of an Ultrahigh-bandwidth Phase Contrast Imaging System for detection of electron scale turbulence and Gigahertz Radio-Frequency Waves

The study of waves and turbulence is vital to the development of future reactor-grade plasma devices developed in the quest for fusion energy. These fluctuations are responsible for moving heat and particles across the magnetic field, and a predictive understanding of them is needed to achieve the density and temperature required to sustain a plasma fusion reaction. While many techniques have been developed for measuring waves and fluctuations, every measurement method has limitations. There are relatively few techniques for measuring very high frequency fluctuations, such as radio frequency waves injected to heat the plasma, unstable waves driven by suprathermal particles, or short wavelength electrostatic waves driven by electron temperature or density gradients. The present project builds upon the proven phase contrast imaging (PCI) technique to extend the response of the diagnostic by orders of magnitude in frequency and almost a factor of ten in spatial resolution. PCI provides a measurement of electron density based on small angle scattering of a CO-2 laser beam by using optical techniques to render a phase shift as an intensity change on a detector. Due to the telecommunications revolution, technological development by manufacturers has focused on components in the near -infrared, so that high- quality lasers and detectors at 1.55 µm are readily available. Shifting PCI design to a new, shorter wavelength has numerous advantages and challenges. Similar detector performance is available with room-temperature arrays with GHz bandwidth, while the detector arrays for 10.6 µm required liquid nitrogen cooling and were therefore limited to a bandwidth of about 1 MHz. Shifting to a shorter wavelength reduces the angle at which the laser beam scatters off of plasma waves, allowing more such scattered components to pass through the aperture of the vacuum vessel port and be collected by the PCI, which increases the spatial resolution. Concomitant with these benefits, various questions of performance arise. At shorter laser wave- length, the sensitivity to mirror and lens quality is increased, the contribution of the laser to the overall system noise is increased, and the sensitivity to vibrations is increased. The custom optical components at the heart of the PCI technique were required to be properly scaled for the shorter wavelength, so fabrication technologies needed to be explored. This project was designed to show that a low noise, high response PCI system at 1.55 µm could be constructed and operated, and then to quantify potential issues to allow extrapolation to a full-size production system providing physics measurements on a large plasma device. The first stage, producing the custom optical component called a Phase Plate, was successfully achieved using two methods. First, an easily reproduced masking and coating technique was able to produce good phase plates with the required parameters. Second, a nanofabrication technique was found to produce extremely high quality phase plates at a competitive price. The PCI constructed with the new phase plates and 1.55 µm laser was found to provide excellent wavelength measurements with the theoretically expected response. The sensitivity to optical surface quality was found to be in line with previous measurements at 10.6 µm. The observed signal-to-noise ratio was similar to the theoretically expected value. The effect of vibrations on PCI was studied with the first measurement of the effect of beam motion on PCI response and comparison to theory, allowing for a quantitative prediction of the effect of vibrations on a production PCI system and the requirements for improved beam stabilization. PCI is an extremely cost-effective method to provide a low noise, absolutely calibrated measurement of plasma fluctuations across a wide spatial scale. This project has shown that a 1.55 µm PCI using modern techniques and components is less expensive than the 10.6 µm PCI of a few years ago, with the largest savings in phase plate fabrication and the infrared detector array.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗