Liquid Oxygen (LO2) propellant conditioning concept testing

Marshall Space Flight Center (MSFC) and industry contractors have undertaken activities to develop a simplified liquid oxygen (LO2) propellant conditioning concept for future expendable launch vehicles. The objective of these activities is to reduce operations costs and timelines and to improve safety of these vehicles. The approach followed has been to identify novel concepts through system level studies and demonstrate the feasibility of these concepts through small-scale and full-scale testing. Testing will also provide data for design guidelines and validation of analytical models. Four different concepts are being investigated: no-bleed, low-bleed, use of a recirculation line, and helium (He) bubbling. This investigation is being done under a Joint Institutional Research and Development (JIRAD) program currently in effect between MSFC and General Dynamics Space Systems (GDSS). A full-scale test article, which is a facsimile of a propellant feed duct with an attached section to simulate heat input from a LO2 turbopump, will be tested at the Cold Flow Facility at MSFC's West Test Area. Liquid nitrogen (LN2), which has similar properties to LO2, will be used in place of LO2 for safety and budget reasons. Work to date includes design and fabrication of the test article, design of the test facility and initial fabrication, development of a test matrix and test procedures, initial predictions of test output, and heat leak calibration and heat exchanger tests on the test article. The tests for all propellant conditioning concepts will be conducted in the summer of 1993, with the final report completed by October, 1993.

Perry, Gretchen L. E.↗

Pressure and heat-transfer distributions in a simulated wing-elevon cove with variable leakage at a free-stream Mach number of 6.9

A concern that ingestion of hot boundary-layer gas past a small, localized seal failure in the cove between the Space Shuttle wing and elevon might threaten unprotected elevon structures led to wind-tunnel tests to define cove environment as a function of leak area. The tests were conducted in the Langley 8-foot high-temperatures structures tunnel using a full-scale representation of the Space Shuttle wing-elevon juncture on the reentry surface. Pressure and heating rates were obtained for both attached and separated turbulent flows on the wing at the cove entrance. Results indicated that (1) for attached turbulent flow on the wing, cove heating progressively increased in severity independent of leak aspect ratio as leak area increased to 100 percent of cove entrance area and (2), for separated turbulent flow over the wing, cove environment was intolerably severe.

Deveikis, W. D.↗

Locating Small Leaks in Large Structures

Test tool for detecting minute leads in bimetal joints, welds, or other locations employs fine-control valve and hypodermic needle. Test item is connected in conventional manner to helium mass spectrometer tuned to read extremely small amounts of helium gas. Uniqueness of method is ability to detect tiny leaks, through surfaces, not discoverable by gross coverage of test structures by helium gas.

Lawler, W. F.↗

Hanford double-shell tank testing program - 15341

The corrosion testing program and Hanford regularly tests waste chemistries to analyze threats and develop new corrosion chemistry guidelines. Over the past few years, the focus of testing has been on the threat of leaked wastes in Tank 241-AY-102 (AY-102). From the tests conducted to date, it appears that the potential waste compositions in the annulus of tank AY-102 do not show a propensity for localized corrosion or stress corrosion cracking. The threat of exterior corrosion from the liquid and moisture in the leak detection pit (LDP) is a potential concern that will continue to be evaluated in the coming year. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 × 10 -5 kg s -1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4 + km 2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1 σ ), when measurements are averaged over 2 min. The results of the synthetic and field data testing show that the new observing system and statistical approach greatly decreases the incidence of false alarms (that is, wrongly identifying a well site to be leaking) compared with the same tests that do not use the NZMB approach and therefore offers increased leak detection and sizing capabilities.

03 NATURAL GAS↗

Production Facility Prototype Blower 1000 Hour Test Results II

Long duration tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks were not included in these tests. Five 1000 hour tests have been completed since the first test was performed in January of 2016. All five 1000 hour tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for each test, including a review of the first and second tests, are included in this report.

42 ENGINEERING↗

Production Facility Prototype Blower 1000 Hour Test Results IV

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Twelve long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All twelve long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the ninth test to the twelfth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, and III.

42 ENGINEERING↗

Production Facility Prototype Blower 1000 Hour Test Results V

Long duration operations tests of the Aerzen GM 12.4 roots style blower in a closed loop configuration provides valuable data and lessons learned for long-term operation at the Mo-99 production facility. The blower was operated in a closed loop configuration with the flow conditions anticipated in plant operation with a Mo-100 target inline. The additional thermal energy generated from beam heating of the Mo-100 disks was not included in these tests. Thirteen long duration 500 to 1000 hour tests have been completed since the first test was performed in January of 2016. All thirteen long duration tests have proven successful in exposing preventable issues related to oil and helium leaks. All blower tests to this date have resulted in stable blower performance and consistency. A summary of the results for the end of the thirteenth test is included in this report. Complete details for the previous tests are shown in the reports, Production Facility Prototype Blower 1000 Hour Test Results, II, III, and IV.

36 MATERIALS SCIENCE↗

Large Scale Testing of a Foam/Multilayer Insulation Thermal Control System (TCS) for Cryogenic Upper Stages

The development of high energy cryogenic upper stages is essential for the efficient delivery of large payloads to various destinations envisioned in future programs. A key element in such upper stages is cryogenic fluid management (CFM) advanced development/technology. Due to the cost of and limited opportunities for orbital experiments, ground testing must be employed to the fullest extent possible. Therefore, a system level test bed termed the Multipurpose Hydrogen Test Bed (MHTB), which is representative in size and shape (3 meter diameter by 3 meter long with a volume of 18 cubic meters) of a fully integrated space transportation vehicle liquid hydrogen propellant tank has been established. To date, upper stage studies have often baselined the foam/multilayer insulation (FMLI) combination concept; however, hardware experience with the concept is minimal and was therefore selected for the MHTB. The foam element (isofoam SS-1 171 with an average thickness of 3.5 centimeters) is designed to protect against ground hold/ascent flight environments, and allows for the use of a dry nitrogen purge as opposed to the more complex/heavy helium purge subsystem normally required with MLI in cryogenic applications. The MLI (45 layers of Double Aluminized Mylar with Dacron spacers) provides protection in the vacuum environment of space and is designed for an on-orbit storage period of 45 days. Several unique features were incorporated in the MLI concept and included: variable density MLI (reduces weight and radiation losses by changing the layer density), larger but fewer DAM perforations for venting during ascent to orbit (reduces radiation losses), and roll wrap installation of the MLI with a commercially established process to lower assembly man-hours and reduce seam heat leak. Thermal performance testing of the MHTB TCS was conducted during three test series conducted between September 1995 and May 1996. Results for the ground hold portion of the tests were as expected producing an average heat leak of 63 WattS/M2 at an average foam surface temperature of 170 K. The results of the simulated orbit hold test interval produced heat leaks ranging from 0.085 to 0.22 Watts/squareM at warm boundary temperatures of 164K and 305K, respectively. When compared to the performance for a traditional MLI system, a 60% reduction in orbital heat leak or boiloff was measured. Overall, the MHTB TCS demonstrated satisfactory performance for all mission phases required of a cryogenic upper stage.

Hastings, Leon↗

Hermetic Seal Leak Detection Apparatus

The present invention is a hermetic seal leak detection apparatus, which can be used to test for hermetic seal leaks in instruments and containers. A vacuum tight chamber is created around the unit being tested to minimize gas space outside of the hermetic seal. A vacuum inducing device is then used to increase the gas chamber volume inside the device, so that a slight vacuum is pulled on the unit being tested. The pressure in the unit being tested will stabilize. If the stabilized pressure reads close to a known good seal calibration, there is not a leak in the seal. If the stabilized pressure reads closer to a known bad seal calibration value, there is a leak in the seal. The speed of the plunger can be varied and by evaluating the resulting pressure change rates and final values, the leak rate/size can be accurately calculated.

Kelley, Anthony R.↗

Characteristics of refrigerant leaks from small HVAC&R systems

Reduced use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants is desired. However, many lower-GWP alternatives are flammable, some of higher flammability levels, or A3, and others of lower flammability (A2 or A2L).Safety standards for A2 and A3 flammable refrigerants, including the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 calculate maximum flammable refrigerant charge limits using a fixed 4-minute leak time based on the time to leak 150 g of CO2 through a capillary tube.Actual refrigerant leak times depend on the equipment type, leak location, leak orifice diameter and equipment operation condition (on or off).Five systems were installed in test chambers with leak quantities and rates measured by tracking total system weight during the leak event. Among the major results were that almost all of the system charge was shown to escape the units, >80% within the first 10 minutes.

Patel, Viral↗

Demonstration of rapid and sensitive module leak certification for Space Station Freedom

A leak detection and quantification demonstration using perflurocarbon tracer (PFT) technology was successfully performed at the NASA Marshall Space Flight Center on January 25, 1991. The real-time Dual Trap Analyzer (DTA) at one-half hour after the start of the first run gave an estimated leak rate of 0.7 mL/min. This has since been refined to be 1.15 (+ or -) 0.09 mL/min. The leak rates in the next three runs were determined to be 9.8 (+ or -) 0.7, -0.4 (+ or -) 0.3, and 76 (+ or -) 6 mL/min, respectively. The theory on leak quantification in the steady-state and time-dependent modes for a single zone test facility was developed and applied to the above determinations. The laboratory PFT analysis system gave a limit-of-detection (LOD) of 0.05 fL for ocPDCH. This is the tracer of choice and is about 100-fold better than that for the DTA. Applied to leak certification, the LOD is about 0.00002 mL/s (0.000075 L/h), a 5 order-of-magnitude improvement over the original leak certification specification. Furthermore, this limit can be attained in a measurement period of 3 to 4 hours instead of days, weeks, or months. A new Leak Certification Facility is also proposed to provide for zonal (three zones) determination of leak rates. The appropriate multizone equations, their solutions, and error analysis have already been derived. A new concept of seal-integrity certification has been demonstrated for a variety of controlled leaks in the range of module leak testing. High structural integrity leaks were shown to have a linear dependence of flow on (Delta)p. The rapid determination of leak rates at different pressures is proposed and is to be determined while subjecting the module to other external force-generating parameters such as vibration, torque, solar intensity, etc.

Dietz, R. N.↗

Risk Evaluation for the Diesel Fuel Leak Near Generator Building TRA-674 at the Advanced Test Reactor Complex

This report describes the risk-based evaluation conducted for the underground diesel fuel leak near Generator Building TRA-674 at the Advanced Test Reactor Complex, located at the Idaho National Laboratory. The risk evaluation process followed the Idaho Risk Evaluation Manual for Petroleum Releases (August 2012) guidance document and used the Idaho Risk Evaluation Computational Software (August 2015) to estimate the human health risks posed by residual contamination. Site-specific data were collected to estimate the representative concentrations of the soil for estimating the cumulative risk. Based on historical and current data, the site does not exceed unacceptable risk to human health receptors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressure Loading with In-Situ Permeability Measurement of SiC Ceramic Matrix Composite Tube

Silicon carbide fiber in a silicon carbide matrix composite (SiC-SiC) has been actively researched as a potential structural material to be used in advanced high temperature gas reactors (HTGR) and as an accident tolerant cladding material for light water reactors (LWR). This ceramic composite material demonstrates desirable properties for use in nuclear reactor core that include retention of strength from ambient to LWR and HTGR operating and accident temperatures and stability under neutron radiation. However, the ceramic composite material must be designed to meet all the necessary, application driven requirements before it could be implemented in a reactor design. As one of the requirements for a fuel cladding material, the composite has to maintain high level of impermeability as to retain fission gases throughout the fuel cycle. General Atomics (GA) had previously reported results on permeability levels obtained by CVI produced SiC-SiC composites. It has been determined that for LWR size cladding tube that is 51 mm long the permeability allocation equivalent to currently used claddings is 7.3 E-10 atm*cc/sec. With high level of attention to possible sources of leaks in a test setup, it has been demonstrated that a CVI SiC-SiC composites produced by GA can achieve a leak rate of 1 E-12 atm*cc/sec, and therefore it meets the permeability allocation for a fuel cladding. Further study showed that a particular SiC-SiC composite tube can remain impermeable after being pressure loaded well above LWR normal operating conditions. In the study done by Deck et al., hoop stress was applied to a composite tube using pressure load on the inside surface in a load-unload stepwise sequence with increasing maximum applied stress at each step and measuring permeability between steps. The tested composite comprised of 70% thickness of SiC-SiC composite which provides fracture toughness and bears a majority of the applied stress and a 30% thickness of monolithic SiC layer on the outside surface to provide an impermeable barrier. The composite remained impermeable up to internal pressure of 56 MPa which is more than 2.5 times greater than a typical pressure at the end of life in a fuel rod.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Hazardous Gas Leak Analysis in the Space Shuttle

Helium tests of the main propulsion system in the Space Shuttle and on hydrogen leaks are examined. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers (MS) to monitor the shuttle environment for leaks. The mass spectrometers are fed by long tubes to sample gas from the payload bay, mid-body, aft engine compartment, and external tank. The purpose is to improve the HGDS, especially in its potential for locating cryogen leaks. Pre-existing leak data was analyzed for transient information to determine if the leak location could be pinpointed from test data. A rapid response leak detection experiment was designed, built, and tested. Large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MS was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MS data. One conclusion is that the backup HGDS sampling frequency should be increased above the present rate of 1 sample per second.

Barile, Ronald G.↗

Fiber Optic Cable Feedthrough and Sealing

A novel fiberoptic hermetic bulkhead feedthrough has been developed which will offer cryogenic sealing at leak rates of 10(exp -11) cc/sec helium. This feedthrough was developed for NASA in response to needs for a hermetically sealed feedthrough which could withstand a range of temperatures from low cryogenic (-196 C), due to liquid fuels and oxidizers, to high temperatures (+200 C) encountered in the proximity of combustion gasses. The development effort will be reported from conceptual design of single and multi-channel feedthrough units with single interconnection interfaces to units with double-ended interconnection interfaces. Various combinations of fiber/buffers are reported with recommendations based on test results. A comprehensive series of environmental and mechanical tests were performed to evaluate the feedthroughs in adverse conditions. Test results are reported including insertion loss, salt spray, sinusoidal vibration, random vibration, mechanical shock, thermal shock and humidity. A second set of feedthrough units was exposed to 3 different types of radiation. Optical transmittance changes during the tests were monitored and leak rate testing was done after each test. State-of-the-art technology in optical fiber feedthroughs constructed with polycrystalline ceramic is presented.

Fan, Robert J.↗