Search NASA⌕ Search

SEARCH · Search NASA

Results for “Life Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Long cycle life microporous spherical carbon anodes for sodium-ion batteries derived from furfuryl alcohol

Spherical micron-sized carbon powders were synthesized from feedstock furfuryl alcohol and tested as anodes in sodium ion batteries (SIBs). A long cycle life of 1000 cycles is achievable with this carbon at C rate (3–4 mg cm –2 loading and i = 200 mA g –1 ) yielding a steady capacity of ca. 115 mA h g –1 . Furthermore, the results from solid-state 23Na MAS NMR analyses of cycled electrodes indicate no correlation in voltage profiles with sodium site nature (graphene or nanopores), which is a new observation in SIB carbon anodes.

25 ENERGY STORAGE↗

BTMS Testing Section

Cell testing is an important part of understanding the performance and life capabilities of state-of-the art energy storage technologies, particularly with respect to the distinct technical and functional requirements posed by the BTMS program. In order to test energy storage components and systems against these requirements, test procedures must be created. System usage scenarios are concurrently being developed with testing of baseline cells intended to illustrate their capabilities relative to a broad set of initial system assumptions. The results from these early performance tests and aging procedures, though only loosely framed by a baseline 1 MWh BTMS system supporting six 350kW DCFC units, will produce both slow and accelerated cycle-life aging information through a mix of empirical observations and modeling.

25 ENERGY STORAGE↗

The Nature and State of Groundwater Contamination at the Nevada National Security Site: What Have We Learned from Decades of Groundwater Analysis? - 20337

The regulatory framework for remediating radionuclide contamination from underground nuclear testing at the Nevada National Security Site (NNSS) is based on a combination of characterization and modeling studies, monitoring, and institutional controls [1]. Currently, tritium is the largest contributor (∼90%) to the estimated 44.6 million-curie radionuclide inventory resulting from underground testing [2]. Because of its short half-life (12.32 years), its relative contribution reduces below 10% of the total radiologic inventory over the next 120 years as a result of radioactive decay. Although tritium levels are observed well above the Safe Drinking Water Act (SDWA) maximum contaminant levels (MCLs) in groundwater, other radionuclides are well below their MCLs except within the nuclear test near-field (nuclear test cavity and chimney) environment. In fact, most device-derived radionuclides are below their MCL in groundwater even in samples collected from this near-field environment. The distribution of radionuclides following the nuclear detonation greatly influences the availability of potential contaminants for groundwater transport. Tritium is initially distributed in the gas phase, later as tritiated water in steam, and finally as liquid water, and is available to groundwater transport away from the near-field environment. Other radionuclides that are mobile in groundwater are {sup 14}C, {sup 36}Cl, {sup 99}Tc, and {sup 129}I though their radiologic inventory is small when compared to tritium. Many radionuclides (e.g. U, Pu, Am) are incorporated to a significant extent into the melt glass at the bottom of the cavity and are accessible to groundwater primarily through the slow process of glass dissolution. These radionuclides are also adsorbed to the surfaces of the crushed rock within the cavity and chimney which limits their migration in groundwater. Although colloid facilitated transport of radionuclides at the NNSS has been observed [3], radionuclide concentrations decrease with time and migration distances due to desorption and colloid filtration processes. Current studies indicate that radionuclides associated with colloids are unlikely to migrate downgradient from NNSS underground nuclear tests at concentrations above the SDWA MCL [4][5]. The results of over 50 years of sampling, along with an understanding of these post detonation processes, indicate that tritium is the only contaminant of concern downgradient of testing and that even tritium will not exceed its MCL in groundwater after ∼120 years. Although other longer-lived radionuclides may continue to be released slowly from the near-field environment they will likely never reach levels exceeding their MCLs in groundwater downgradient of the NNSS. Groundwater monitoring will continue to verify these observations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Precipitate Phase Stability and Mechanical Properties of Alloy 263 and Variants in Wrought or Cast Form

Alloy 263 is a candidate Ni-based superalloy for use in advanced ultra-supercritical (AUSC) power plants that are targeted to operate above 700 °C. Exposure times in this type of environment are considerable with target creep properties specified at 100,000 h making phase stability an important parameter in the alloy selection process. In this investigation, the microstructure of alloy 263 and two modified compositions in both cast and cast/wrought forms were investigated after exposure at 800 °C for various times ranging from 1,000 h to 10,000 h. Tension and creep properties were assessed for all alloys in both forms. Modification to the Ti and Al concentrations successfully slowed down the γ' to η transformation while doubling the γ' fraction. Thin elongated η needles or platelets formed in the wrought products while thicker, plate-like, η precipitates were found in the castings. The effect of the various microstructures on the creep properties were determined using isothermally aged specimens aged at 800 °C for 3,000 h and 10,000 h prior to creep screening. Strong precipitation of the η phase was found to considerably decrease creep life and increase minimum creep rate. By modifying the Ti and Al content, the creep life and ductility of the new formulation tested on specimens isothermally aged for 3,000 and 10,000 h were near that of the nominal alloy in its standard aged condition.

Detrois, Martin↗

Defining the Optimal Planning Target Volume in Image-Guided Stereotactic Radiosurgery of Brain Metastases: Results of a Randomized Trial

Purpose: To identify an optimal margin about the gross target volume (GTV) for stereotactic radiosurgery (SRS) of brain metastases, minimizing toxicity and local recurrence. Methods and Materials: Adult patients with 1 to 3 brain metastases less than 4 cm in greatest dimension, no previous brain radiation therapy, and Karnofsky performance status (KPS) above 70 were eligible for this institutional review board–approved trial. Individual lesions were randomized to 1- or 3- mm uniform expansion of the GTV defined on contrast-enhanced magnetic resonance imaging (MRI). The resulting planning target volume (PTV) was treated to 24, 18, or 15 Gy marginal dose for maximum PTV diameters less than 2, 2 to 2.9, and 3 to 3.9 cm, respectively, using a linear accelerator–based image-guided system. The primary endpoint was local recurrence (LR). Secondary endpoints included neurocognition Mini-Mental State Examination, Trail Making Test Parts A and B, quality of life (Functional Assessment of Cancer Therapy-Brain), radionecrosis (RN), need for salvage radiation therapy, distant failure (DF) in the brain, and overall survival (OS). Results: Between February 2010 and November 2012, 49 patients with 80 brain metastases were treated. The median age was 61 years, the median KPS was 90, and the predominant histologies were non–small cell lung cancer (25 patients) and melanoma (8). Fifty-five, 19, and 6 lesions were treated to 24, 18, and 15 Gy, respectively. The PTV/GTV ratio, volume receiving 12 Gy or more, and minimum dose to PTV were significantly higher in the 3-mm group (all P<.01), and GTV was similar (P=.76). At a median follow-up time of 32.2 months, 11 patients were alive, with median OS 10.6 months. LR was observed in only 3 lesions (2 in the 1 mm group, P=.51), with 6.7% LR 12 months after SRS. Biopsy-proven RN alone was observed in 6 lesions (5 in the 3-mm group, P=.10). The 12-month DF rate was 45.7%. Three months after SRS, no significant change in neurocognition or quality of life was observed. Conclusions: SRS was well tolerated, with low rates of LR and RN in both cohorts. However, given the higher potential risk of RN with a 3-mm margin, a 1-mm GTV expansion is more appropriate.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Biaxial creep performance of CWSR Zircaloy-4 cladding at emulated off-normal conditions of interim dry storage facility

In this study, biaxial creep behavior of hydrided Zircaloy-4 cladding was tested at 500 degrees C. Creep-life was inversely proportional to H-concentration up to 750 wppm. The weakening through hydride reorientation of hydrided specimens was not observed by optical microscopy. The power-law stress exponents and the TEM observation supported the high-temperature climb mechanism dominated the creep behavior in secondary stage.

36 MATERIALS SCIENCE↗

Impact of environmental variables on the degradation of photovoltaic components and perspectives for the reliability assessment methodology

Backsheet cracking has been a major issue observed in the field; however, standardized qualification tests, such as IEC61215, are inadequate to reliably identify such failures of PV modules due to the lack of the critical weathering factors applied sequentially or in combination, such as those found in the service environments. To address this problem, in this work we investigated the effects of various environmental variables on the degradation and failure behaviors of the polyamide-based backsheet in PV modules retrieved from five different locations, encompassing a variety of climates, including humid subtropical, hot-summer Mediterranean, tropical savanna climate and hot arid. The correlations between the degradation indicators and the weathering variables were further demonstrated by principle components analysis (PCA). We found strong relationships between: carbonyl formation and reflected solar radiation; hydroxyl formation and module temperature; yellowness and NO2 concentration, while no simple correlation could be found between a specific weathering factor and cracking. By introducing additional stress factors to the aged polyamide-based backsheet films with the novel 'fragmentation test', we successfully reproduced the field cracking behaviour. This study has demonstrated that different degradation modes of PV components respond differently to the environmental stresses encountered in service. Thereby, any accelerated laboratory test based on a single set condition or lacking key environmental variables would be inadequate to assess the long-term performance of PV modules and components. A new reliability-based methodology is proposed to quantitatively link laboratory testing with field results for the service life prediction of PV materials.

14 SOLAR ENERGY↗

Encapsulation of Metallic Na in an Electrically Conductive Host with Porous Channels as a Highly Stable Na Metal Anode

Room-temperature Na ion batteries (NIBs) have attracted great attention because of the widely available, abundant sodium resources and potentially low cost. Currently, the challenge of the NIB development is due primarily to the lack of a high-performance anode, while the Na metal anode holds great promise considering its highest specific capacity of 1165 mA h/g and lowest anodic potential. However, an uneven deposit, relatively infinite volume change, and dendritic growth upon plating/stripping cycles cause a low Coulombic efficiency, poor cycling performance, and severe safety concerns. In this study, a stable Na carbonized wood (Na–wood) composite anode was fabricated via a rapid melt infusion (about 5 s) into channels of carbonized wood by capillary action. The channels function as a high-surface-area, conductive, mechanically stable skeleton, which lowers the effective current density, ensures a uniform Na nucleation, and restricts the volume change over cycles. As a result, the Na–wood composite anode exhibited flat plating/stripping profiles with smaller overpotentials and stable cycling performance over 500 h at 1.0 mA/cm 2 in a common carbonate electrolyte system. Finally, in sharp comparison, the planar Na metal electrode showed a much shorter cycle life of 100 h under the same test conditions.

09 BIOMASS FUELS↗

ALDCP Student Team 7/25/19 Briefing [Slides]

This set of slides documents the activities of the Associate Laboratory Directorate for Capital Projects (ALDCP) student team during the week of July 25, 2019. It summarizes the involvement of the group in the Smart Lab project, and the individual progress of separate projects, including the Life-Cycle Cost Analysis (LCCA) Calculator and Tests, the HVAC Renovation, and the Renovation Feasibility Study, with accomplishments and barriers for each.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Thermal Evaluation of the SAVY-4000 1 Quart Container at High Heat Loads

The SAVY-4000 Safety Analysis Report (SAR) was published in 2013 which established the design life of the container series through physical testing that meets applicable requirements from DOE M 441.1-1, Nuclear Material Packaging Manual. One critical requirement in DOE M 441.1-1 is to set a maximum heat load for the entire series to ensure that throughout the lifetime of the container, each of the components still performs within manufacture specifications. The original maximum decay heat limit has been defined within the SAVY-4000 SAR, which was accomplished by completing a series of tests that heat loaded the SAVY-4000 series and measured the steady state temperature and graded it against manufacture specifications. The container series is comprised of a corrosion resistant 316L stainless steel containment boundary, ceramic composite filter for the prevention of radiological particulate release and a chemically stable O-ring made of Viton ® . Currently, the SAVY 4000 maximum decay heat load is set at 25 Watts and the heat load expected during normal handling and storage is considered sufficient that the SAVY 4000 container requirements will not be the limiting factor for storage of most common material in use at TA-55, e.g. weapons grade oxide, americium, Pu-238 oxide and encapsulated heat sources. The SAVY 4000 lifetime was originally set as 5 years within the SAVY-4000 SAR, but in July 2019 the lifetime was extended to 15 years through a technical basis justification approved by the Department of Energy (DOE) Los Alamos Field Office. The 25 Watt limit applies to all SAVY 4000 container sizes; 1-quart, 2-quart, 3-quart, 5-quart, 8-quart, 12-quart, 5-gallon, and 10-gallon.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CO 2 Mineralization Using Porous Carbon and Industrial Wastes to Make Multifunctional Concrete

Along with substantial benefits and promises of carbon capture and storage (CCS) technologies, significant challenges exist in developing scalable materials and methods for capture and of CO 2 . The overarching objective of this project is to provide a system approach for developing a new CO 2 capture and utilization technology using porous carbon and industrial wastes to make a low-cost, scalable and multifunctional concrete product. The objective of Phase I of this project is to develop and fine-tune activated carbons from different wastes such as plastic wastes to offer a cheap, abundant and scalable feedstock for CO 2 uptake. The objective of Phase 2 is creating a facile protocol to develop a concrete prototype comprising CO 2 adsorbed activated carbon (e.g. from plastic wastes), followed by product validation, life-cycle analysis, and bench-scale testing. The project objectives are designed to specifically obtain a final product and technology that directly addresses the main goals of the DOE’s CCS programs.

01 COAL, LIGNITE, AND PEAT↗

Development of electronically passivating surfaces to enhance battery performance

For many decades, lithium metal batteries (LMBs) have been studied for their high energy density, though they suffer from high reactivity, which safety concerns such as explosions and fires. These events can occur as a result of degradation due to redox reactions and lithium morphology that evolve during cycling. Mostly, the failure is caused by the electrolyte degradation leading to the creation of a solid electrolyte interphase (SEI), which tends to induce electron leakage, lithium dendrite growth, and capacity decay. SEI formation is practically inevitable. This work investigated the minimization of degradation events by modifying different battery configurations. Modifications were made by exchanging electrolytes, electrode surfaces, and even annexing innovative components. Our goal is to achieve a configuration where Li-ion transfer is facilitated, and electron transfer is limited which would enable a longer lithium metal battery life cycle. When performing these modifications and testing their electrochemical performance, a current reduction was observed when the electrodes were spontaneously coated with preformed SEI. Herein several classes of artificial SEI layers are explored for their ability to form passivating layers through use of a redox active molecule.

25 ENERGY STORAGE↗

Build-to-Replace: A New Paradigm for Reducing Advanced Reactor O&M Costs

Nuclear energy is a carbon free source of reliable, resilient, and dispatchable energy that has the potential to feature prominently in a future energy mix. To this end, many new reactor designs are being developed to help reduce cost and improve safety. Operating and maintenance (O&M) costs can make up a significant portion of lifecycle costs. Traditional approaches for nuclear plant design O&M is to perform significant inspections and testing of plant equipment to extend the life of equipment as long as possible. This is contrasted with approaches used in other industries where equipment is replaced when it is no longer functional in lieu of spending time and resources on maintenance. This research investigated the “build-to-replace” approach for new nuclear power plants. A methodology was developed to evaluate the effectiveness of the “build-to-replace” approach. Several scenarios were developed and analyzed using the approach. Modest reductions in O&M costs were obtained in some cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Degradation in Photovoltaic Encapsulant Transmittance: Results of the Second PVQAT TG5 Artificial Weathering Study

The optical degradation of encapsulants from ultraviolet (UV) radiation has historically resulted in a significant loss in performance throughout the life of a photovoltaic (PV) module. IEC test methods have recently been developed to screen for PV encapsulants prone to loss in optical performance. The present study was performed to benchmark polymeric packaging materials relative to IEC 62788-1-4 (covering the measurement of optical transmittance) and IEC 62788-1-7 (on the durability of transmittance), provide feedback toward improvement of the methods, and develop insight regarding optical degradation. Contemporary materials were examined, including: poly(ethylene-co-vinyl acetate) (EVA), thermoplastic polyolefin (TPO), polyolefin elastomer (POE), and polyvinyl butyral (PVB) encapsulants; a poly(ethene-co-tetrafluoroethene)/poly(ethylene terephthalate) (ETFE/PET) transparent backsheet; and a polystyrene (PS) working reference material. The use of silica-, specialty-, and rolled-glass was also compared in laminated coupons. Specimen size was separately examined from 2.5 cm to 12.5 cm. Weathering was performed with a xenon source, using IEC TS 62788-7-2 methods A2, A3, A4, and A5 (chamber temperature of 55 Degrees C, 65 Degrees C, 75 Degrees C, or 85 Degrees C), respectively. Characterizations were made using a UV-VIS-NIR spectrophotometer (transmittance and reflectance, with and without an integrating sphere), a UV-VIS fluorescence spectrophotometer, a camera, and an optical microscope. Performance was analyzed, including solar weighted transmittance, yellowness index, UV cut-off wavelength, and haze (scattering). Separate Arrhenius analyses were performed to assess retention of transmittance and changes in yellowness index. The activation energy for both characteristics was found to range from 15 kJ?mol-1-80 kJ/mol-1, with an average of 48 kJ/mol-1, similar to the average of 45 kJ/mol-1 identified in the previous international PV Quality Assurance Task Force (PVQAT) Task Group 5 (TG5) study of more traditional encapsulants. The separate degradation modes of discoloration and scattering were distinguished in the encapsulants using a comprehensive spectral characterization. Based on these results, the IEC 62788-1-7 pass/fail criteria of 5% change in transmittance was confirmed to identify a known bad encapsulant.

durability↗

Evaluation of Low-cost, Full HD, CMOS Cameras for Use in the Calcine Retrieval Project - 19530

This paper describes results from radiation testing conducted on low-cost, commercial off-the-shelf, full high-definition (HD) resolution (1920 x 1080 p), complementary metal-oxide-semiconductor (CMOS) camera sensors. The purpose of the testing was to evaluate the sensors' suitability for use in the Calcine Retrieval Project by determining their image quality and life expectancy while operating in an ionizing radiation field of 20.0 Gy/h. The two camera sensors tested were the Axis FA1105 and Axis FA1125. These commercial camera sensors were designed for retail security surveillance and have no radiation-hardened (rad-hard) components. In addition to radiation testing, the sensors' field-of-view, resolution, and low-light image quality were tested at several target distances to ensure they meet project requirements. Testing was divided into two phases. During Phase 1, four FA1105 sensors and four FA1125 sensors were tested simultaneously without any shielding in radiation fields of 25.5 Gy/h and 49.3 Gy/h. In Phase 2, three FA1105 and five FA1125 sensors were shielded by 22.2 mm of lead and tested simultaneously in radiation fields of 26.8 Gy/h, 52.3 Gy/h, 143.0 Gy/h, 200.7 Gy/h, 404.6 Gy/h, and 2,317.5 Gy/h. Dose rate values were established using film dosimetry readings. Apertures in the shielding allowed for a 40-degree field of view while shielding all parts of the sensor except for directly in front of the CMOS sensor array. All testing was conducted at the Idaho Accelerator Center in Pocatello, Idaho, using a 450 keV X-ray generator. Sensor images were automatically captured at regular intervals throughout the testing for qualitative evaluation by the test team. Film dosimetry was placed near the sensors to record actual dose totals. The 450 keV setting generates X-ray radiation with an energy level close to the primary gamma energy level produced by the Cesium-137 isotope in the calcine, which is 662 keV. Results from Phase 1 indicate the sensors failed at an average cumulative dose of 226.3 Gy. For a given 20.0 Gy/h field this results in a mean time to failure (MTTF) of 11.3 hours. Recorded images from all sensors showed minimal image degradation due to radiation-induced noise. When the sensors finally failed, the failure mode was an abrupt loss of video. The image went black suggesting some other component in the sensor head besides the CMOS sensor array was responsible for the failure. During a portion of Phase 1 testing, a commercial, rad-hard camera was irradiated in the 25.5 Gy/h field along with the eight Axis FA series sensors. Image quality from the FA series sensors significantly outperformed the image quality of the rad-hard camera in radiation-induced noise tolerance, image resolution, and dynamic range. During Phase 2 testing, all sensors produced excellent images in radiation fields as high as 404.6 Gy/h. One FA1125 sensor was tested at the highest dose rate of 2,317.5 Gy/h. At this dose rate, the image was color shifted towards red and contained a significant amount radiation-induced noise. The sensor did not fail and was producing usable imagery after one hour, at which time the test was ended due to allotted beam-time at the test facility. Eighteen hours after X-rays were shut off, the sensor image returned to normal color and all eight sensors continued to operate without any visible, permanent image degradation. For Phase 2 testing, it was not possible to establish a MTTF since none of the shielded sensors failed during the allotted test time. However, given the highest cumulative dose of 4,142.1 Gy received by a shielded FA1125 sensor, a minimum life expectancy of 207 hours (8.6 days) is predicted while operating in a 20.0 Gy/h field. Test results indicate the radiation tolerance of the FA series sensor's CMOS array, along with the small form factor, full HD image quality, wide dynamic range, and Ethernet standard makes it suitable for short-term use in monitoring and visually documenting waste remediation efforts for the Calcine Retrieval Project at the INL. The sensor's low-cost of about $140 US, compared to commercial rad-hard cameras costing between $5,000 and $7,000 US each, allow them to be used as an affordable, disposable resource for many short-duration, radioactive waste remediation efforts where decontamination of an expensive, commercial rad-hard camera is undesirable or not possible. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maintaining Continuity of Knowledge of Spent Fuel Pools: Field Testing (Final Report)

Maintaining Continuity of Knowledge (CoK) of spent fuel throughout its life cycle is a key objective of the International Atomic Energy Agency (IAEA). This report describes a project in which two specific technologies, cameras with infrared (IR) imaging capabilities and imaging sonar, were tested to determine their effectiveness in augmenting optical surveillance cameras currently used for maintaining CoK for spent nuclear fuel (SNF) staged in spent fuel pools. Furthermore, the project identifies any modifications required to the technologies to facilitate deployment for international safeguards purposes. This report presents results for the imaging sonar tested at Sandia National Laboratories (SNL) in a mockup spent nuclear fuel pool and for the IR-capable cameras tested by Pacific Northwest National Laboratory (PNNL) in the Oregon State University Training, Research, Isotopes, General Atomics (TRIGA) research reactor.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verification of Maximal Oxygen Uptake in Active Military Personnel During Treadmill Running

Figueiredo, PS, Looney, DP, Pryor, JL, Doughty, EM, McClung, HL, Vangala, SV, Santee, WR, Beidleman, BA, and Potter, AW. Verification of maximal oxygen uptake in active military personnel during treadmill running. J Strength Cond Res 36(4): 1053–1058, 2022—It is unclear whether verification tests are required to confirm “true” maximal oxygen uptake ($\dot{V}_{o2}$max) in modern warfighter populations. Our study investigated the prevalence of $\dot{V}_{o2}$max attainment in U.S. Army soldiers performing a traditional incremental running test. In addition, we examined the utility of supramaximal verification testing as well as repeated trials for familiarization for accurate $\dot{V}_{o2}$max assessment. Sixteen U.S. Army soldiers (1 woman, 15men; age, 21±2 years; height, 1.73±0.06m; body mass, 71.6±10.1 kg) completed 2 laboratory visits, each with an incremental running test (modified Astrand protocol) and a verification test (110% maximal incremental test speed) on a motorized treadmill. We evaluated $\dot{V}_{o2}$max attainment during incremental testing by testing for the definitive $\dot{V}_{o2}$ plateau using a linear least-squares regression approach. Peak oxygen uptake ($\dot{V}_{o2}$peak) was considered statistically equivalent between tests if the 90% confidence interval around the mean difference was within 62.1 ml·kg -1 ·min -1 . Oxygen uptake plateaus were identified in 14 of 16 volunteers for visit 1 (87.5%) and all 16 volunteers for visit 2 (100%). Peak oxygen uptake was not statistically equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between the incremental test and verification test on visit 1 (2.3 ml·kg -1 ·min -1 , [1.3–3.2]) or visit 2 (1.1 ml·kg -1 ·min -1 [0.2–2.1]). Interestingly, $\dot{V}_{o2}$peak was equivalent, apparent from the mean difference in $\dot{V}_{o2}$peak measures between visits for the incremental tests (0.0ml·kg -1 ·min -1 [-0.8to 0.9]) but not the verification tests (-1.2 ml·kg -1 ·min -1 [-2.2 to -0.2]). Modern U.S. Army soldiers can attain $\dot{V}_{o2}$max by performing a modified Astrand treadmill running test. Additional familiarization and verification tests for confirming $\dot{V}_{o2}$max in healthy active military personnel may be unnecessary.

60 APPLIED LIFE SCIENCES↗