Search NASA⌕ Search

SEARCH · Search NASA

Results for “Liquid helium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Status review of liquid rocket static test range at Iowa State University

The liquid rocket static test range of the Iowa State University incorporates an Aerobee sustainer propulsion system consisting of a pressure fed (helium) liquid bipropellant (hypergolic) rocket engine with a regeneratively fuel-cooled thrust chamber assembly. The paper covers test results to date (including results of four test firings in the water expulsion mode), construction details of the test stand, the laboratory course syllabus, and the environmental impact statement.

Brodsky, R. F.↗

Research Investigation Directed Toward Extending the Useful Range of the Electromagnetic Spectrum

The report discusses completed and proposed research in atomic and molecular physics conducted at the Columbia Radiation Laboratory from July 1972 to June 1973. Central topics described include the atomic spectra and electronic structure of alkali metals and helium, molecular microwave spectroscopy, the resonance physics of photon echoes in some solid state systems (including Raman echoes, superradiance, and two photon absorption), and liquid helium superfluidity.

Hartmann, S. R.↗

Using Electrostriction to Manipulate Ullage in Microgravity

A report proposes to use electrostriction to manipulate the ullage in a tank containing a dielectric liquid in a microgravitational environment. In the original intended application, the liquid would be a spacecraft propellant and the goal would be to force the ullage (comprising bubbles of noncondensible gas) to coalesce at one end of the tank, to enable use of one of the established means of (1) measuring the position of the gas/liquid interface and (2) inferring the quantity of liquid from the measurement. Electrically insulated wires would be installed in the tank, shaped and positioned so that application of a suitably high potential (e.g., 1 kV) between adjacent wires in successive pairs would give rise to a sufficient electric field gradient along the tank. The resulting electrostriction in the liquid would give rise to a pressure gradient that would force the ullage toward the low-electric-field-magnitude end of the tank. The feasibility of this proposal was demonstrated in an experiment in a tank containing liquid helium aboard an airplane flying a low-gravity arc. The ullage-segregating electrostrictive effect is expected to be considerably greater in other liquids.

Chui, Talso↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and susperfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm, and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (9 cycles at 4.2 K), and superfluid helium temperature (4 cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak-rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10(-9) std-cc/sec, during testing.

Salerno, Louis J.↗

Performance of all-metal demountable cryogenic seals at superfluid helium temperatures

Two all-metal demountable cryogenic seals with an outside diameter of 36.6 mm, inside diameter of 27.2 mm and thickness of 0.51 mm were leak-tested at room temperature (300 K), liquid nitrogen temperature (21 cycles at 77 K), liquid helium temperature (nine cycles at 4.2K) and superfluid helium temperature (four cycles at 1.6 K). Each seal was mounted and demounted for 13 cycles. Thickness measurements at 90 deg intervals along the circumference showed a maximum seal compression of 0.038 mm. Leak rate measurements at all temperatures showed no detectable leak above the helium background level, typically 0.1 x 10 exp -9 std cu cm/s, during testing.

Salerno, L. J.↗

Dynamics and Morphology of Superfluid Helium Drops in a Microgravity Environment

We developed an apparatus that makes it possible to observe and study magnetically levitated drops of superfluid helium. The force on a diamagnetic substance in a magnetic field is proportional to the gradient of the square of the magnetic field B. For the magnetic force on helium to be equal to the gravitational force on Earth, it is necessary for the product of B with the field gradient dB/d z to be 21.5 T(exp 2)/cm. In addition, in order for the magnetic field to provide a stable trap, the value of B(exp 2) must increase in all directions in the horizontal plane that passes through the point where the field/field gradient product in the vertical direction has the critical value of 21.5 T(exp 2)/cm. A specially designed superconducting magnet that meets these specifications has been installed in a large helium dewar with optical access. Helium drops levitated by the magnet can be viewed along the axis of the solenoid. The sample chamber within the bore of the magnet is thermally isolated from the magnet and helium reservoir. Its temperature can be varied between 4 and 0.5 K, the lower part of the range being reached using a He-3 refrigerator. Liquid helium can be injected into the magnetic trap using a small capillary. Once a drop is contained in the trap it can be held there indefinitely. With this apparatus we have conducted a number of different types of experiments on helium drops so as to gain information necessary for performing experiments in space. With magnetically levitated drops we are limited to working with drops of 1 cm. or less in diameter. The shape of the drops larger than a few mm diameter can be distorted by the profile of the magnetic field. The study of phenomena such as the initial motion of the surfaces of two drops as they just make contact, requires the use large drops to resolve the behavior of interest. We have performed a detailed investigation of the shape oscillations of superfluid drops.

Seidel, George M.↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

Dynamic Characteristics of the Partially Filled Rotating Dewar of the Gravity Probe-B Spacecraft

The dynamical behavior of fluids, in particular the effect of surface tension on partially-filled rotating fluids (cryogenic liquid helium and helium vapor) in a full scale Gravity Probe-B Spacecraft propellant dewar tank imposed by various frequencies of gravity jitters have been investigated. The study of the liquid-vapor interface oscillations due to various frequencies of gravity jitter under different dewar rotating speeds and different levels of background gravity have been numerically simulated. Results disclose the time sequence evolution for the excitation of large amplitude oscillation waves at the liquid-vapor interface. The study shows that slosh waves excited inside the spacecraft propellant tank are characterized by the lowest frequency of the waves initiated, frequencies of the gravity jitters imposed on the propellant system, the levels of background gravity environment, and dewar rotating speeds. Conditions for suppression and amplification of the slosh waves are discussed. It also shows that fluid stress distribution exerted on the walls of the rotating dewar are closely related to the characteristics of slosh waves excited on the liquid-vapor interface in the rotating dewar tank. This can provide a set of data leading toward the control of spacecraft imbalance caused by the uneven fluid stress distribution from slosh waves.

Hung, R. J.↗

Development of a Flexible Seal for a 60 psi Cryogenic Pressure Box

A cryogenic pressure box test facility has been designed and fabricated for use at NASA Langley Research Center (LaRC) to subject 5 ft x 6 ft curved panels to cryogenic temperatures and biaxial tensile loads. The cryogenic pressure box is capable of testing curved panels down to -423 F (20 K) with 54 psig maximum pressure. The key challenge in the design and fabrication of the pressure box was the development of a seal that could remain flexible at -423 F and contain 60 psi gaseous helium as the pressurization gas. A C-shaped seal was developed using a Gore-tex woven fabric. Mechanical testing of the fabric at room and elevated temperature, liquid nitrogen temperature, and liquid helium temperature demonstrated the strength and creep resistance of the material over the desired operating range. A small scale cryogenic pressure box was used to test prototype seals at cryogenic temperatures up to 60 psi. Preliminary tests indicated that excessive leakage was present through the seal. As a result, an aluminized mylar liner was placed inside the Gore-tex seal to reduce leakage through the seal. The final seal configuration resulted in minimal pressure loss during seal testing.

Glass, David E.↗

Germanium resistance thermometer calibration at superfluid helium temperatures

The rapid increase in resistance of high purity semi-conducting germanium with decreasing temperature in the superfluid helium range of temperatures makes this material highly adaptable as a very sensitive thermometer. Also, a germanium thermometer exhibits a highly reproducible resistance versus temperature characteristic curve upon cycling between liquid helium temperatures and room temperature. These two factors combine to make germanium thermometers ideally suited for measuring temperatures in many cryogenic studies at superfluid helium temperatures. One disadvantage, however, is the relatively high cost of calibrated germanium thermometers. In space helium cryogenic systems, many such thermometers are often required, leading to a high cost for calibrated thermometers. The construction of a thermometer calibration cryostat and probe which will allow for calibrating six germanium thermometers at one time, thus effecting substantial savings in the purchase of thermometers is considered.

Mason, F. C.↗

The AXAF/XRS test dewar - A versatile design

The X-Ray Spectrometer (XRS) to be flown on the Advanced X-ray Astrophysics Facility (AXAF) consists of an array of microcalorimeters and an Adiabatic Demagnetization Refrigerator (ADR). The ADR provides an operating temperature of 0.065 to 0.100 K. To support extensive development testing of the ADR and the detector array, a test dewar has been designed and built that surpasses specification requirements. Pumping on the liquid helium bath with a 47 l/s pump, we have achieved temperatures lower than 1.5 K with a hold time in excess of 72 hrs. The dewar can be operated without liquid nitrogen with a hold time of 36 hrs. This feature was incorporated in the design because boiling nitrogen may introduce microphonic noise to the detectors. To further reduce the susceptibility to microphonic vibration a unique suspension system utilizing Kevlar fibers was devised which provides both translational and rotational rigidity to the detector mount. Finally, the dewar is very manageable and may be rotated by only one person.

Weintz, Karl F.↗

Calibration of Germanium Resistance Thermometers

Largely completed thermometer-calibration cryostat and probe allows six germanium resistance thermometers to be calibrated at one time at superfluid-helium temperatures. In experiments involving several such thermometers, use of this calibration apparatus results in substantial cost savings. Cryostat maintains temperature less than 2.17 K through controlled evaporation and removal of liquid helium from Dewar. Probe holds thermometers to be calibrated and applies small amount of heat as needed to maintain precise temperature below 2.17 K.

Ladner, D.↗

Analysis of the Cosmic Background Explorer (COBE) helium venting through effects on the orbit

An analysis is described which shows that a helium venting thrust level that is 60 percent higher than the predicted 2.3 millinewtons may be the cause of the unusually high premission-analysis and on-orbit support orbital decay rates and drag correction factors found for the Cosmic Background Explorer satellite. Depletion of the helium allowed a determination of the average mass flow rate and specific impulse. The average mass flow rate of 3.3 mg/sec confirmed the thrust levels indicated by the venting thrust analysis. Liquid helium is used for cooling instruments aboard the satellite.

Cox, C. M.↗

Operation of helium sub-atmospheric multistage cryogenic centrifugal compressor trains: Part 1 – Steady state modeling and speed ratio selection

Helium cryogenic systems which can provide cooling below the normal boiling point of helium (approximately 4.2 K) are often required by superconducting radio-frequency niobium resonators utilized in modern high-energy particle accelerators. Achieving temperatures below 4.2 K generally involves operating a cryogenic vessel with liquid helium under sub-atmospheric conditions, thereby lowering the saturation pressure and corresponding saturation temperature. Over the last several decades, multi-stage cryogenic centrifugal compressor trains (CC’s) have been operated efficiently and reliably within large-scale cryogenic systems to continuously evacuate helium vapor generated by a device within the vessel, maintaining sub-atmospheric conditions in the vessel while pressurizing the return vapor to above atmospheric conditions. Traditionally, these CC systems have been operated using empirically derived control philosophies and insight gathered from previous operational experience. Recent efforts at the Facility for Rare Isotope Beams (FRIB) have been aimed at the development of a theoretical basis to characterize the operation of multi-stage cryogenic centrifugal compressor train and utilizing predictive model results to generate control parameters. The objective of this research was identifying operational points which adequately balance cryogenic system efficiency, stability, and overall ease of operation. Furthermore, this manuscript provides an overview of the predictive model development, characterization of the FRIB cryogenic centrifugal compressors and implementation of the predicted performance results during steady-state system operation.

Compressor train control↗

Helium droplet infrared spectroscopy of the butyl radicals

Butyl radicals (n-, s-, i-, and tert-butyl) are formed from the pyrolysis of stable precursors (1-pentyl nitrite, 2-methyl-1-butyl nitrite, isopentyl nitrite, and azo-tert-butane, respectively). The radicals are doped into a beam of liquid helium droplets and probed with infrared action spectroscopy from 2700 to 3125 cm -1 , allowing for a low temperature measurement of the CH stretching region. The presence of anharmonic resonance polyads in the 2800–3000 cm -1 region complicates its interpretation. To facilitate spectral assignment, the anharmonic resonances are modeled with two model Hamiltonian approaches that explicitly couple CH stretch fundamentals to HCH bend overtones and combinations: a VPT2+K normal mode model based on coupled-cluster with single, double, and perturbative triple excitations [CCSD(T)] quartic force fields and a semi-empirical local mode model. Both of these computational methods provide generally good agreement with the experimental spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Helium refrigerator

An improved helium refrigerator of the type which includes a plurality of counter-flow heat exchangers and has a maximum reserve cooling capacity when the final or low-temperature heat exchanger is substantially filled with liquid helium, and a minimum reserve cooling capacity when the low-temperature heat exchanger is substantially filled with gas. An electrical bridge circuit including a pair of temperature responsive resistors is mounted on the low-temperature heat exchanger for providing a continuous indication of the reserve cooling capacity of the refrigerator.

Ervin R Wiebe↗