Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Analytical study of pressure balancing in gas film seals

The load factor is investigated for subsonic and choked flow conditions, laminar and turbulent flows, and various seal entrance conditions. Both parallel sealing surfaces and surfaces with small linear deformation were investigated. The load factor for subsonic flow depends strongly on pressure ratio; under choked flow conditions, however the load factor is found to depend more strongly on film thickness and flow entrance conditions rather than pressure ratio. The importance of generating hydrodynamic forces to keep the seal balanced under severe and multipoint operation is also discussed.

Zuk, J.↗

Analytical study of pressure balancing in gas film seals.

Proper pressure balancing of gas film seals requires knowledge of the pressure profile load factor (load factor) values for a given set of design conditions. In this study, the load factor is investigated for subsonic and choked flow conditions, laminar and turbulent flows, and various seal entrance conditions. Both parallel sealing surfaces and surfaces with small linear deformation were investigated. The load factor for subsonic flow depends strongly on pressure ratio; under choked flow conditions, however, the load factor is found to depend more strongly on film thickness and flow entrance conditions rather than pressure ratio. The importance of generating hydrodynamic forces to keep the seal balanced under severe and multipoint operation is also discussed.

Zuk, J.↗

Influence of Computational Drop Representation in LES of a Droplet-Laden Mixing Layer

Multiphase turbulent flows are encountered in many practical applications including turbine engines or natural phenomena involving particle dispersion. Numerical computations of multiphase turbulent flows are important because they provide a cheaper alternative to performing experiments during an engine design process or because they can provide predictions of pollutant dispersion, etc. Two-phase flows contain millions and sometimes billions of particles. For flows with volumetrically dilute particle loading, the most accurate method of numerically simulating the flow is based on direct numerical simulation (DNS) of the governing equations in which all scales of the flow including the small scales that are responsible for the overwhelming amount of dissipation are resolved. DNS, however, requires high computational cost and cannot be used in engineering design applications where iterations among several design conditions are necessary. Because of high computational cost, numerical simulations of such flows cannot track all these drops. The objective of this work is to quantify the influence of the number of computational drops and grid spacing on the accuracy of predicted flow statistics, and to possibly identify the minimum number, or, if not possible, the optimal number of computational drops that provide minimal error in flow prediction. For this purpose, several Large Eddy Simulation (LES) of a mixing layer with evaporating drops have been performed by using coarse, medium, and fine grid spacings and computational drops, rather than physical drops. To define computational drops, an integer NR is introduced that represents the ratio of the number of existing physical drops to the desired number of computational drops; for example, if NR=8, this means that a computational drop represents 8 physical drops in the flow field. The desired number of computational drops is determined by the available computational resources; the larger NR is, the less computationally intensive is the simulation. A set of first order and second order flow statistics, and of drop statistics are extracted from LES predictions and are compared to results obtained by filtering a DNS database. First order statistics such as Favre averaged stream-wise velocity, Favre averaged vapor mass fraction, and the drop stream-wise velocity, are predicted accurately independent of the number of computational drops and grid spacing. Second order flow statistics depend both on the number of computational drops and on grid spacing. The scalar variance and turbulent vapor flux are predicted accurately by the fine mesh LES only when NR is less than 32, and by the coarse mesh LES reasonably accurately for all NR values. This is attributed to the fact that when the grid spacing is coarsened, the number of drops in a computational cell must not be significantly lower than that in the DNS.

Bellan, Josette↗

CFD Parametric Study of Consortium Impeller

Current design of high performance turbopumps for rocket engines requires effective and robust analytical tools to provide design impact in a productive manner. The main goal of this study is to develop a robust and effective computational fluid dynamics (CFD) pump model for general turbopump design and analysis applications. A Finite Difference Navier-Stokes flow solver, FDNS, which includes the extended k-epsilon turbulence model and appropriate moving interface boundary conditions, was developed to analyze turbulent flows in turbomachinery devices. A second-order central difference scheme plus adaptive dissipation terms was employed in the FDNS code, along with a predictor plus multi-corrector pressure-based solution procedure. The multi-zone, multi-block capability allows the FDNS code to efficiently solve flow fields with complicated geometry. The FDNS code has been benchmarked by analyzing the pump consortium inducer, and it provided satisfactory results. In the present study, a CFD parametric study of the pump consortium impeller was conducted using the FDNS code. The pump consortium impeller, with partial blades, is a new design concept of the advanced rocket engines. The parametric study was to analyze the baseline design of the consortium impeller and its modification which utilizes TANDEM blades. In the present study, the TANDEM blade configuration of the consortium impeller considers cut full blades for about one quarter chord length from the leading edge and clocks the leading edge portion with an angle of 7.5 or 22.5 degrees. The purpose of the present study is to investigate the effect and trend of the TANDEM blade modification and provide the result as a design guideline. A 3-D flow analysis, with a 103 x 23 x 30 mesh grid system and with the inlet flow conditions measured by Rocketdyne, was performed for the baseline consortium impeller. The numerical result shows that the mass flow rate splits through various blade passages are relatively uniform. Due to the complexity of blade geometries, the TANDEM blade configurations were analyzed with the multi-zone grid structure. Both the 7.5 deg- and the 22.5 deg-clocking TANDEM blade cases utilized a 80K mesh system. The numerical result of two TANDEM blade modifications indicates the efficiency and the head are worse than those of the baseline case due to larger flow distortion. The gap between the TANDEM blade and the full blade allows the flow passes through and heavily loads the pressure side of the partial blade such that flow reversal occurs near the suction side of the splitter. The flow split at the exit of impeller blades is very non-uniform for TANDEM blade cases, and this will greatly induce the side load on the diffuser. Therefore, the TANDEM blade modification in the present CFD analysis does not improve the performance of the consortium impeller.

Cheng, Gary C.↗

MHD channel performance for potential early commercial MHD power plants

The commercial viability of full and part load early commercial MHD power plants is examined. The load conditions comprise a mass flow of 472 kg/sec in the channel, Rosebud coal, 34% by volume oxygen in the oxidizer preheated to 922 K, and a one percent by mass seeding with K. The full load condition is discussed in terms of a combined cycle plant with optimized electrical output by the MHD channel. Various electrical load parameters, pressure ratios, and magnetic field profiles are considered for a baseload MHD generator, with a finding that a decelerating flow rate yields slightly higher electrical output than a constant flow rate. Nominal and part load conditions are explored, with a reduced gas mass flow rate and an enriched oxygen content. An enthalpy extraction of 24.6% and an isentropic efficiency of 74.2% is predicted for nominal operation of a 526 MWe MHD generator, with higher efficiencies for part load operation.

Swallom, D. W.↗

Transitioning of power flow in beam models with bends

The propagation of power flow through a dynamically loaded beam model with 90 degree bends is investigated using NASTRAN and McPOW. The transitioning of power flow types (axial, torsional, and flexural) is observed throughout the structure. To get accurate calculations of the torsional response of beams using NASTRAN, torsional inertia effects had to be added to the mass matrix calculation section of the program. Also, mass effects were included in the calculation of BAR forces to improve the continuity of power flow between elements. The importance of including all types of power flow in an analysis, rather than only flexural power, is indicated by the example. Trying to interpret power flow results that only consider flexural components in even a moderately complex problem will result in incorrect conclusions concerning the total power flow field.

Hambric, Stephen A.↗

HLPW-4: Wall-Modeled LES and Lattice-Boltzmann Technology Focus Group Workshop Summary

A summary of the nine submissions to the Wall-Modeled LES and Lattice-Boltzmann(WMLESLB) Technical Focus Group (TFG) at the 4th High lift Prediction Workshop is provided. The focus of this TFG was to assess the current capabilities of WMLES and LB methods on a complex high-lift configuration across a wide range of angles-of-attack. Analysis of the submitted data suggests that>250𝑀spatial degrees of freedom are needed to accurately predict pitching moments at high angles-of-attack due to large pressure gradients present on the outboard slat and main element for 𝛼 >17◦(corrected for free-air). While some scatter is reported in pitching moment coefficient at the low-angles of attack (𝛼 <11◦) - excellent agreement is observed between submissions near the 𝐶𝐿,max state. Objective superiority of WMLES methods over RANS can be seen in terms of lack of excess outboard separation; a majority of the WMLES and LB submissions predict wedge-shaped separation patterns consistent with the experimental oil flow. The in-tunnel simulations show excellent agreement with the experiment in terms of a) integrated loads, b) surface flow-topology, and c) mechanism for the onset of inboard stall. Further evidence is provided to demonstrate both qualitative and quantitative superiority of the WMLES submissions over RANS.

TTT↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, J.↗

Estimation of the Unsteady Aerodynamic Load on Space Shuttle External Tank Protuberances from a Component Wind Tunnel Test

At the wake of the Columbia (STS-107) accident it was decided to remove the Protuberance Aerodynamic Load (PAL) Ramp that was originally intended to protect various protuberances outside of the Space Shuttle External Tank from high buffet load induced by cross-flows at transonic speed. In order to establish the buffet load without the PAL ramp, a wind tunnel test was conducted where segments of the protuberances were instrumented with dynamic pressure transducers; and power-spectra of sectional lift and drag forces at various span-wise locations between two adjacent support brackets were measured under different cross flow angles, Mach number and other conditions. Additionally, frequency-dependent spatial correlations between the sectional forces were also established. The sectional forces were then adjusted by the correlation length to establish span-averaged spectra of normal and lateral forces that can be suitably "added" to various other unsteady forces encountered by the protuberance. This paper describes the methodology used for calculating the correlation-adjusted power spectrum of the buffet load. A second part of the paper describes wind-tunnel results on the difference in the buffet load on the protuberances with and without the PAL ramp. In general when the ramp height is the same as that of the protuberance height, such as that found on the liquid Oxygen part of the tank, the ramp is found to cause significant reduction of the unsteady aerodynamic load. However, on the liquid Hydrogen part of the tank, where the Oxygen feed-line is far larger in diameter than the height of the PAL ramp, little protection is found to be available to all but the Cable Tray.

Panda, Jayatana↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Nonlinear quasi-fracture behavior of polymers

This paper deals with the nonlinear quasi-fracture behavior of polymers. Using the finite element method, the quasi-fracture model composed of an isolated craze opening with a nonlinear boundary envelope forces represented by oriented fibril domains is analyzed in simply-stressed rectangular plate. The stress distribution, the displacement profile, as well as the yield or plastic or flow zone adjacent to the craze tips are obtained. It is found that the variation of the stress distribution near the craze tip is not as sharp as that for an elastic crack. The initial load required for yielding or flowing is greater for the quasifracture as compared with that for a classical fracture. Under the same load the yield or flow zone is somewhat smaller as compared with that obtained on the basis of linear elastic-plastic fracture mechanics theory.

Sun, B. N.↗

Spring-Loaded Joule-Thomson Valve

Improved design reduces clogging and maintains constant pressure drop as flow rate varies. Spring-Loaded Joule-Thomson Valve pressure drop regulated by spring pushing stainless-steel ball against soft brass seat. Pressure drop remains nearly constant, regardless of helium flow rate and of any gas contaminants frozen on valve seat. Because springloaded J-T valve maintains constant pressure drop, upstream roomtemperature throttle valve adjusts flow rate precisely for any given upstream pressure. In addition, new valve relatively invulnerable to frozen gas contaminants, which clog fixed-orifice J-T valves.

Jones, J. A.↗

TPSAS-NF1676L-12321-DND

The operation of some networks, such as air transportation networks, can be complicated by congestion through a small subset of nodes. The congestion may be influenced by the connectivity of the network, or by the presence of constraints restricting the flow through particular nodes. This work investigates the effects of both connectivity and node flow constraints on the operation of a network. We develop the Minimax Node Load Problem (MNLP), a multicommodity flow model which minimizes the worst-case flow through any node in a given input network. The optimal solution to this problem provides us with the minimax node load, which we propose as a measure of network congestion. Keeping the number of nodes fixed, we first increase connectivity in a series of networks, and observe that topologies with more distributed connections result in a reduction in the minimax node load. However, when connectivity is increased further, the reductions diminish and are accompanied by solutions with undesirable qualities such as longer commodity paths. We then perform a second set of experiments over the same network, constraining flow through different subsets of nodes at different magnitudes of flow restriction, finding that (1) more constrained nodes lead to the largest increases in minimax node load and (2) constraints on the most connected nodes have the greatest effect on both congestion and commodity path length.

Douglas W Lee↗

TPSAS-NF1676L-12264-DND

The operation of some networks, such as air transportation networks, can be complicated by congestion through a small subset of nodes. The congestion may be influenced by the connectivity of the network, or by the presence of constraints restricting the flow through particular nodes. This work investigates the effects of both connectivity and node flow constraints on the operation of a network. We develop the Minimax Node Load Problem (MNLP), a multicommodity flow model which minimizes the worst-case flow through any node in a given input network. The optimal solution to this problem provides us with the minimax node load, which we propose as a measure of network congestion. Keeping the number of nodes fixed, we first increase connectivity in a series of networks, and observe that topologies with more distributed connections result in a reduction in the minimax node load. However, when connectivity is increased further, the reductions diminish and are accompanied by solutions with undesirable qualities such as longer commodity paths. We then perform a second set of experiments over the same network, constraining flow through different subsets of nodes at different magnitudes of flow restriction, finding that (1) more constrained nodes lead to the largest increases in minimax node load and (2) constraints on the most connected nodes have the greatest effect on both congestion and commodity path length.

Douglas Lee↗

Effects of Unsteady Flow Interactions on the Performance of a Highly-Loaded Transonic Compressor Stage

The primary focus of this paper is to investigate the loss sources in an advanced GE transonic compressor design with high reaction and high stage loading. This advanced compressor has been investigated both experimentally and analytically in the past. The measured compressor efficiency is significantly lower than the efficiency calculated with various existing tools based on RANS and URANS. The general understanding is that some important flow physics in this modern compressor design are not represented in the current tools. To pinpoint the source of the efficiency miss, an advanced test with detailed flow traverse was performed for the front one and a half stage at the NASA Glenn Research Center. In the present paper, a Large Eddy Simulation (LES) is employed to determine whether a higher-fidelity simulation can pick up any additional flow physics that can explain past efficiency miss with RANS and URANS. The results from the Large Eddy Simulation were compared with the NASA test results and the GE interpretation of the test data. LES calculates lower total pressure and higher total temperature on the pressure side of the stator, resulting in large loss generation on the pressure side of the stator. On the other hand, existing tools based on the RANS and URANS do not calculate this high total temperature and low total pressure on the pressure side of the stator. The calculated loss through the stator from LES seems to match the measured data and the GE data interpretation. Detailed examination of the unsteady flow field from LES indicates that the accumulation of high loss near the pressure side of the stator is due to the interaction of the rotor wake with the stator blade. The strong rotor wake interacts quite differently with the pressure side of the stator than with the suction side of the stator blade. The concave curvature on the pressure side of the stator blade increases the mixing of the rotor wake with the pressure side boundary layer significantly. On the other hand, the convex curvature on the suction side of the stator blade decreases the mixing and the suction side blade boundary layer remains thin. The jet velocity in the rotor wake in the stator frame seems to magnify the curvature effect in addition to inviscid redistribution of wake fluid toward the pressure side of the blade.

LES↗

Power flows and Mechanical Intensities in structural finite element analysis

The identification of power flow paths in dynamically loaded structures is an important, but currently unavailable, capability for the finite element analyst. For this reason, methods for calculating power flows and mechanical intensities in finite element models are developed here. Formulations for calculating input and output powers, power flows, mechanical intensities, and power dissipations for beam, plate, and solid element types are derived. NASTRAN is used to calculate the required velocity, force, and stress results of an analysis, which a post-processor then uses to calculate power flow quantities. The SDRC I-deas Supertab module is used to view the final results. Test models include a simple truss and a beam-stiffened cantilever plate. Both test cases showed reasonable power flow fields over low to medium frequencies, with accurate power balances. Future work will include testing with more complex models, developing an interactive graphics program to view easily and efficiently the analysis results, applying shape optimization methods to the problem with power flow variables as design constraints, and adding the power flow capability to NASTRAN.

Hambric, Stephen A.↗

Analysis of Ares Crew Launch Vehicle Transonic Alternating Flow Phenomenon

A transonic wind tunnel test of the Ares I-X Rigid Buffet Model (RBM) identified a Mach number regime where unusually large buffet loads are present. A subsequent investigation identified the cause of these loads to be an alternating flow phenomenon at the Crew Module-Service Module junction. The conical design of the Ares I-X Crew Module and the cylindrical design of the Service Module exposes the vehicle to unsteady pressure loads due to the sudden transition between a subsonic separated and a supersonic attached flow about the cone-cylinder junction as the local flow randomly fluctuates back and forth between the two flow states. These fluctuations produce a square-wave like pattern in the pressure time histories resulting in large amplitude, impulsive buffet loads. Subsequent testing of the Ares I RBM found much lower buffet loads since the evolved Ares I design includes an ogive fairing that covers the Crew Module-Service Module junction, thereby making the vehicle less susceptible to the onset of alternating flow. An analysis of the alternating flow separation and attachment phenomenon indicates that the phenomenon is most severe at low angles of attack and exacerbated by the presence of vehicle protuberances. A launch vehicle may experience either a single or, at most, a few impulsive loads since it is constantly accelerating during ascent rather than dwelling at constant flow conditions in a wind tunnel. A comparison of a windtunnel- test-data-derived impulsive load to flight-test-data-derived load indicates a significant over-prediction in the magnitude and duration of the buffet load. I. Introduction One

Sekula, Martin K.↗