Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparison of wind-farm control strategies under realistic offshore wind conditions: wake quantities of interest

Wind-farm control strategies aim to increase the efficiency, and therefore lower the levelized cost of energy, of wind farms. This is done by using turbine settings such as the yaw angle, blade pitch angles, or generator torque to manipulate the wake that negatively affects downstream turbines in the farm. Two inherently different wind-farm control methods have been identified in the literature: wake steering (WS) and active wake mixing (AWM). As one of two companion papers focused on understanding practical aspects of these two wind-farm control strategies using large-eddy simulation (LES), we below analyze the wake quantities of interest for a single wind turbine performing WS and AWM, while the companion article (Frederik et al., 2025) focuses on turbine quantities of interest including power and structural loads for the same computational setup and also includes two-turbine arrays with full and partial wake overlap. The simulations, which are based in the LES solver AMR-Wind, are tailored to have inflow conditions representative of measurements from a site off the East Coast of the US, including with strong veer and low turbulence. The turbine, which is modeled in OpenFAST and coupled to the LES, is the IEA 15 MW, an open-source offshore design. After presenting an overview of the wake recovery for the different wake-control cases, the analysis probes the fluid-dynamic causes for the different performance of the arrays reported in the companion article by examining control volumes around the wakes and the budget of the mean-flow kinetic energy (MKE) within these volumes. In the high veer environment considered, the MKE recovery is dominated by mean convection, and this is shown to especially benefit the WS strategy when a neighboring turbine is directly downstream: there is ≈65 % more available power for a downstream turbine than in the baseline case, and this power is gained primarily through mean convection on the left-tip and top-tip faces of the control volume. However, the case with imperfect knowledge of the exact wind direction favors the pulse-type AWM strategy, largely because of ≈9 % increased turbulent entrainment from aloft versus the baseline that could be related to an apparent resistance to skewing in the pulsed wake. The general reduced effectiveness of helix-type and other individual-pitch-based AWM strategies for inflow with high veer and low turbulence as reported in the companion paper is due, in part, to low magnitudes of phase-averaged turbulent entrainment. Two main findings of this study are thus that veer has a significant impact on the effectiveness of different wake-control strategies and that pulse-type AWM may be a useful strategy when the objective is power maximization in realistic, offshore flow environments with imperfect knowledge of the exact wake overlap position on the downstream turbine.

17 WIND ENERGY↗

Study of eVTOL Charging Impact on Airport Electrical Grids

Growth in commercial air traffic has increased the aviation industry's contribution to global emissions. Aircraft electrification can reduce greenhouse gas emissions along with being efficient and reliable. Advanced air mobility introduces the idea of an advanced and more efficient air transportation system. Electric and hybrid aircraft designs, such as electric vertical takeoff and landing (eVTOL), are being considered for a number of applications, such as urban air mobility, cargo delivery, and medical emergencies. Although the electrification of aircraft provides environmental benefits, their charging needs will place significant demand on the electrical grid. This work presents a grid impact study and infrastructure upgrade requirements analysis of eVTOL charging on a realistic distribution grid through power flow simulation analysis. The case study results show that the eVTOL charging can lead to power quality issues, such as undervoltage and equipment capacity overloading. Grid infrastructure, such as lines and transformers, would need to be upgraded, and voltage management strategies would need to be deployed to accommodate eVTOL charging at an existing airport.

advanced air mobility (AAM)↗

Thermal-Fluid and Thermal-Structural Response of the T-Tube Modular Divertor to Spatiotemporally Varying Heat Loads

Tungsten (W) is the leading candidate for divertor target plates because of its high melting point (>3000°C), thermal conductivity, and ultimate tensile stress. While W and its alloys are the only solid materials that can survive the high heat fluxes incident on the divertor, W’s low-ductility high ductile-to-brittle transition temperature of ~600°C and relatively low recrystallization temperature (RT) of ~1300°C pose structural (among other) challenges. The objective of this work is to estimate the thermal-fluid and thermal-structural performance of the helium (He)-cooled T-tube divertor, which was originally developed by the Advanced Reactor Innovation and Evaluation Study (ARIES) using numerical simulations. Here, predictions of temperature distributions across the plasma-facing structural component and surface pressures from computational fluid dynamics simulations are used to determine stress distributions using commercial structural finite element modeling software over a range of fusion-relevant conditions. The maximum allowable incident heat fluxes are determined based on the temperature limits imposed by the ITER elastic Structural Design Criteria for In-vessel Components (SDC-IC) and the maximum RT over a range of He mass flow rates and presented in the form of performance design charts. Our recent work found that thermal- structural criteria accounting for the low ductility of W in a finger-type modular divertor constrain the maximum incident heat fluxes to values well below the ITER specifications, and those based on considering only the RT demonstrate that integrated thermal-fluid and elastic structural performance evaluation are required for accurate assessment of divertor performance. This novel analysis of the T-tube considers how nonuniform and transient incident heat fluxes affect its thermal-fluid and thermal-structural performance, as well as the effect of volumetric heating, which can be as great as 27% of the power incident on the divertor surface. The W tile of the T-tube, with its relatively large plasma-facing area of ~15 cm 2 , will likely experience significant spatial variations in incident heat flux. This work therefore assesses whether steady-state incident heat flux profiles with a peak of 10 MW/m 2 and maximum heat flux gradients of 200 MW/m 2 per m exceed the structural limits imposed by the ITER elastic SDC-IC and the maximum RT over a range of fusion-relevant conditions. The effect of transient heat fluxes typical of plasma detachment and reattachment from the target plate due, for example, to gas injection are also evaluated

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Action at a distance: The remarkable coupling of CO 2 uptake to electron transfer in specialized cyanobacterial NDH-1 complexes

Cyanobacteria achieve highly efficient photosynthesis using a CO 2 -concentrating mechanism relying on specialized Type I (NDH-1) complexes. Among these, NDH-1 3 and NDH-1 4 catalyze redox-coupled hydration of CO 2 to bicarbonate, supporting carbon fixation in carboxysomes. The mechanism of coupling electron transfer to CO 2 -hydration by these variant NDH-1 complexes remains unknown. We engineered a Synechococcus PCC7942 strain that expresses exclusively the high flux/low affinity NDH-14 complex, enabling the observation of the coupling of CO 2 hydration to cyclic electron flow in isolation from the other NDH-1 isoforms normally present in cells. We found that inhibition of the CupB protein by the carbonic anhydrase inhibitor ethoxzolamide (EZ) suppressed CO 2 uptake, slowed photosystem I rereduction, and abolished proton pumping as probed by acridine orange fluorescence. These effects were absent in strains lacking Cup proteins, confirming specificity. The results demonstrate that CO 2 hydration and electron transfer through NDH-14 are tightly coupled via proton translocation across the thylakoid membrane. These findings provide direct evidence for the bidirectional interaction in bioenergetic coupling between the plastoquinone reduction and the CO 2 uptake at the distal Zn-site over a span of ~150 Å and support a proton-removal hypothesis involving the proton transfer pathways from the Zn-site of CO2 hydration to an energetically coupled proton loading site evolutionarily repurposed from the ancestral proton pumping mechanism to enable energetic CO 2 uptake.

59 BASIC BIOLOGICAL SCIENCES↗

Balance of Plant Modeling and Real-Time Hardware-in-the-Loop Integration with the Microreactor Automated Control System

The advent of novel microreactor technology has driven a focused effort to explore safety and efficiency improvements that can be achieved through the use of automated system control. Development of control strategies, especially for initial demonstration, requires an adequate surrogate environment to safely research failure modes and control integration with realistic hardware delay. However, efficiency gains from control strategies are improved when the scope of controller action is expanded to include system-level dynamics such as downstream heat extraction and mass flow. For this reason, a balance-of-plant (BOP) model of a representative microreactor system has been developed using the TRANsient Simulation Framework of Reconfigurable Models library in Modelica. This model captures a reactor and primary NaK coolant loop that represent corresponding system components of the Microreactor Applications Research Validation and EvaLuation (MARVEL) design as well as a secondary coolant loop and heat extraction representative of the Microreactor Agile Non-Nuclear Experimental Test Bed (MAGNET). This model configuration allows for hardware-in-the-loop (HIL) integration with microreactor automated control system (MACS) hardware in real time through a Python-based gRPC client. Real-time simulation of model performance with emulated hardware and communication delay suggests that under independent proportional-integral-derivative control of BOP model drum dynamics and downstream heat extraction, stable power load following is achievable. A slight delay in load following, filtering of high-frequency dynamics, and localized temperature fluctation suggest room for improvement through the development of higher-level control strategies. The simulated coupling of the MAGNET facility lays the groundwork for future digital twin analysis with a coupled MACS-MAGNET HIL demonstration.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.↗

Colorado Residential Resiliency and Managed Charging

Validate and model impacts of electric vehicle (EV) home charging on service transformers; analyze diverse grid locations and configurations to determine 'risk factors'; finalize/deliver new design tools and typical EV load curves; improve/issue new construction standards for transformers, secondaries, and services. To ensure residential charging equity, smart charge management strategies will be studied and analyzed with the goal of creating affordable demand charges for customers.

33 ADVANCED PROPULSION SYSTEMS↗

Development of a bench-scale dissolution concept for the direct extraction of nuclear fuel

Current used nuclear fuel reprocessing efforts utilize a hydrometallurgical approach in which the UNF is dissolved in hot nitric acid followed by solvent extraction into an organic solvent to harvest target nuclides. Previous studies have shown that the dissolution and loading process could be combined into a single organic dissolution/extraction step, producing loaded organic in a single step process. This single step process also includes the advantage of selectively targeting key nuclides in the dissolution while leaving undesirable constituents as part of the undissolved solids. This process is referred to hereafter as direct extraction. Ongoing research from multiple national labs has proven the effectiveness of this technique at research scale. Therefore, potential methods to implement direct extraction at both bench and industrial scale have been developed. The key features of potential dissolver system designs were identified via the team at Pacific Northwest National Laboratory and several designs based on industrial counterparts were assessed for feasibility. This report summarizes the advantages and disadvantages of multiple methods, concluding with a path forward to create multiple unique dissolver designs. The first design will be a single stage recirculating eductor mixer. The second design recommendation is a stator rotor static mixing flow loop design. Each dissolver could be utilized separately, simultaneously, or in series to answer questions surrounding reaction kinetics including residence time, provide a proof of concept for targeted extractions of specific nuclides, and inform needs for industrial scale implementation

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pushing the Envelope-Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream: Preprint

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

anisotropic envelope↗

Pushing the Envelope—Moving Dynamic Building Envelope Thermal Energy Storage Systems Mainstream

Buildings contribute to nearly 40% of the U.S. national energy consumption and a significant portion of CO2 emissions. More importantly, disadvantaged communities are disproportionately affected by energy burden and thermal discomfort in their homes. This paper will discuss two novel DOE's BTO supported thermal energy storage (TES) integrated dynamic building envelope technologies, their ability to harvest ambient energy, and improve energy efficiency by reducing HVAC loads and peak electricity demand while enhancing energy and thermal resilience in buildings. The paper will also discuss the recent advancements that have made these systems more affordable and easier to integrate into new and existing buildings. The first solution is a thermally anisotropic building envelope (TABE) system that can redirect ambient thermal energy (heat or coolness) from diurnal outdoor conditions, solar irradiance, and night sky radiation from the envelope to a hydronic loop. The redirected thermal energy can be stored in a TABE-integrated thermal energy storage system and use the stored energy to offset HVAC energy use and peak demand. The second solution is an innovative plug-and-play thermal switch in the form of insertable plugs integrated with a phase change material (PCM). The plug can vary its thermal resistance based on the indoor and outdoor conditions, thus allowing preferential directional heat flow, and enhancing utilization of free ambient cooling and heating to charge/discharge the PCM, much like a solid-state economizer. While the fist solution can be actively controlled, the second solution is passive, requiring no external power, and work solely based on the ambient temperature.

Shrestha, Som↗

HTGR Multiphysics Application Drivers FY26 Updates

This report summarizes FY26 progress under the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program's high-temperature gas-cooled reactor (HTGR) application driver work, covering a wide range of activities such as code validation and multi-physics code assessment. 1) A detailed SAM model of the High-Temperature Engineering Test Reactor (HTTR) was developed using a unique-block grouping approach, with an extended parallel thermal network method to capture block-to-block conduction and radiation heat transfer, and applied to steady-state simulations of the HTTR 30~MW and 9~MW cases. 2) In another activity, SAM's newly implemented multi-component gas flow model was validated against the Natural convection Shutdown heat removal Test Facility (NSTF) argon ingress experiment, correctly capturing the density-driven suppression and thermal recovery of natural circulation observed when argon is introduced into the air-cooled Reactor Cavity Cooling System (RCCS) loop. 3) For the OECD/NEA High Temperature Test Facility (HTTF) benchmark, we co-led the international benchmark activities as well as the OECD/NEA final benchmark report to be released at the end of this year. 4) Finally, the coupled Griffin-SAM modeling capability for pebble-bed HTGRs was advanced by verifying the Griffin neutronics solution against Serpent Monte Carlo for a realistic non-uniform temperature distribution, resolving several deficiencies in the SAM-to-Griffin temperature transfer scheme, and enabling distinct fuel kernel, moderator, and coolant temperatures for cross section feedback. These new features were demonstrated in a PBR load-following transient.

Lee, Alvin↗

Characteristics of Fluid‐Solid Interaction Constitutive Models Within Poroelastodynamics at Higher Strain‐Rates and Large Deformations Implemented in 1D

The large deformation, mixed formulation, finite element (FE) modeling approach presented in Irwin et al. 2024 is extended herein to include improved constitutive models for representing dynamic solid-fluid interactions at higher strain rates (𝒪⁢(1⁢0 2 −1⁢0 3 )⁢s −1 ) and larger overpressure magnitudes (𝒪⁡(1⁢0 2 )⁢kPa) within a biphasic soft porous material using Theory of Porous Media (TPM) at finite strain. Specifically, these constitutive modeling improvements are the following: (i) a more physically robust constitutive model for pore fluid seepage velocity via inclusion of pore fluid viscous stress, and (ii) a modified deformation-dependent-permeability model and updated hyperelastic constitutive model better suited for handling larger volumetric compressions and extensions. The novelty of the present work is mainly the contribution (i): inclusion of pore fluid viscous stress at higher strain-rate and large deformations, which requires 𝐶 1 continuity in the weak formulation, accomplished by employing Hermite cubic interpolation functions within a mixed nonlinear poromechanical finite element formulation. In (ii), the model is updated to weakly enforce solid phase incompressibility, such that this assumption is not violated numerically, which provides improved numerical stability for achieving larger overpressure magnitudes on 𝒪⁡(1⁢0 2 ) kPa, which were not achievable with the previous Kozeny–Carman model in Irwin et al. 2024. Also in (ii), the volumetric part of the solid skeleton free energy function is modified to ensure proper bounds on the solid skeleton Jacobian of deformation 𝐽 s related to incompressibility of the solid phase. Uniaxial strain, unidirectional flow examples at higher strain rates (𝒪⁢(1⁢0 2 −1⁢0 3 )⁢s −1 ) and larger deformations (up to 0.2 (or 20%) nominal axial strain) demonstrate the improved physical representation—and numerical stability—of these constitutive model improvements.

42 ENGINEERING↗

Proton beam power limits for stationary water-cooled tungsten target with different cladding materials

The proton beam power limit for a solid-tungsten spallation target is largely determined by beam induced thermomechanical structural loads and decay heat power deposition, while its lifetime is limited by radiation damage and fatigue life of the target materials. In this paper, we studied the power limits of a stationary water-cooled solid tungsten target concept. Tantalum clad tungsten was considered as a reference case. Being a low activation material, zircaloy 2 cladding option was studied and its decay heat driven power limit was compared with the reference case. Zirconium alloys have proven operations records in spallation target and nuclear fission environments, supported by materials data obtained from post irradiation examinations. Recent study also demonstrated feasibility of diffusion bonding zirconium to tungsten using vanadium foil inter layer. Particle transport simulations code FLUKA was used to calculate energy deposition and decay heat power deposition in the target, based on the beam parameters technically feasible at the Second Target Station of the Spallation Neutron Source at Oak Ridge National Laboratory. The energy deposition data were used for flow, thermal, and structural analyses to determine the beam intensity limit on the target concept studied. The decay heat deposition data were used to calculate the transient temperature evolution in the tungsten volumes in a loss of coolant accident (LOCA) scenario to determine its beam power limit. For a 1.3 GeV proton beam, the power limit on a stationary target was 400 kW for a tantalum clad target model and 800 kW for a zircaloy 2 clad target model.

Lee, Yong Joong↗

TRUST Sensors in Environments: Thermocouples (SE-TC), Release FY25

The Delivery Environments Testbeds to Reduce Uncertainty in Simulations and Tests (TRUST) project is a broad project intended to analyze simplified problems experimentally and with modeling and simulation. The purpose of analyzing these simplified problems is to extend solution methods to more complex problems, as well as understand deficiencies and gaps in knowledge of methods currently used in more complex analyses. The TRUST project encompasses several smaller testbeds intended to isolate individual phenomena. The testbed under consideration in this report is the Sensors in Environments: Thermocouples testbed. In previous years, the purpose of this testbed was to quantify uncertainty of thermocouple sensors. To accomplish this, an aluminum plate was placed in a thermal chamber and subject to various types of thermal loading. Thermocouples were placed in various locations on the aluminum plate in various configurations (e.g., embedded in the plate, placed under Kapton tape), and an effort was made to quantify uncertainty in these measurements. Finite element simulations were performed to investigate how sensitive these measurements were to parameters such as the boundary conditions on the plate and material properties. However, a fundamental source of uncertainty in this analysis was the convective heat transfer from the plate. Convective heat transfer is a complex physical phenomenon comprised of a number of interacting sub-processes and is difficult to predict accurately a priori. As such, the main purpose of this testbed in FY25 was to better understand, both experimentally and numerically, the convective heat transfer from the plate. This is a highly applicable problem to several more complex problems, as convective heat transfer occurs in nearly all problems where a body is moving through air. Numerically, this required a two-step approach. First, the air flow in the thermal chamber was in vestigated using computational fluid dynamics. The commercial solver Fluent was used to perform these simulations. From these simulations, a heat transfer coefficient over the surface of the plate was calculated. This heat transfer was then used as boundary conditions for finite element heat transfer simulations within the plate, which were performed using Abaqus. Significant effort was devoted to automating the handoff between these two solvers. Experimentally, previous thermocouple results in the plate were used to validate the time-dependent thermal profiles produced from Abaqus. Further experimental efforts were performed both to help validate the Fluent simulations and to inform its boundary conditions. For example, hot-wire anemometers were used to measure the velocity in the chamber, which would be particularly useful in understanding the chamber inlet velocity. Thermocouple measurements were also taken in the chamber, instead of only on the plate, to serve as validation evidence for the Fluent simulations. Numerical results showed that the Fluent to Abaqus workflow matched previous plate thermocouple measurements well. This type of handoff is useful for more complex experiments, or those that are not able to be examined in as great of detail as this testbed, as it was performed without any experimental input. Experimental results, however, were more mixed. The anemometers proved unreliable, with inconsistent measurements across all anemometers, even at locations that were nearly identical. On the other hand, the thermocouples provided a relatively rich view of the temperature field in the chamber.

42 ENGINEERING↗

Filament extension atomizers: A study of integration potential into spray dryers for high-viscosity and non-Newtonian fluids

Filament extension atomizers (FEAs) are an emerging class of spray nozzles designed to atomize high-viscosity and non-Newtonian fluids that are challenging for conventional pressure or two-fluid nozzles. In this study, we investigate the influence of roller geometry, surface velocity, roller material, and fluid rheology on the atomization performance of FEA systems using concentrated whey protein suspensions (50–70 wt. %). Extensional and shear rheology experiments, along with high-speed imaging and particle image velocimetry, reveal that filament breakup dynamics are governed by competition between inertial, capillary, and viscoelastic stresses. High roller rotational velocity leads to narrower spray cones, contradicting rheology experiments and suggests a significant inertial contribution to filament breakup. Smaller rollers operating at the same rotational velocity led to broader spray cones consistent with expectations. An FEA nozzle was integrated into a conventional dryer producing particles in the 100 μm range. Results suggest that FEA technology enables atomization of highly viscous fluids at industrially relevant spray cone angles similar to those generated by pressure nozzles, offering a pathway to improve energy efficiency in spray drying by enabling higher solids loading feedstocks. Furthermore, these insights provide critical guidance for optimizing FEA nozzle designs and process parameters across a range of applications.

Energy efficiency↗

In-Field Testing of Components for Feedback and Control of the ITER Disruption Mitigation System

Here, the shattered pellet injection (SPI) method has been chosen as the disruption mitigation system (DMS) for ITER. To protect the device from plasma disruptions that cause damaging heat and electromagnetic loads, SPI is used to inject high-Z material into the plasma. The process of SPI utilizes cryogenic cooling to form solid pellets. Pellets are accelerated down a barrel and into an angled surface, causing the pellet to shatter prior to entering the tokamak chamber. For the DMS to function reliably, the 27 separate shattered pellet injectors planned for ITER must rely on many components to provide accurate feedback data and for control functions. Each component in the DMS is exposed to an elevated background magnetic field depending on its placement and proximity to the plasma chamber. A Helmholtz coil test stand that is operated at Oak Ridge National Laboratory was utilized to test the components in relevant background field levels to assess component performance. This paper details the test design and results for in-field component operation for a variety of components. This list includes the following components: two different network switches for camera connectivity, a VAT fast shutter valve intended to reduce the flow of SPI propellant gas into the torus, a solenoid control valve intended for use in the pellet formation process, pressure/vacuum switches to be used for feedback and control, a printed circuit board piezo pressure sensor to be used to measure breech pressure, and various relays for the high-voltage pulsed power supply used to drive the SPI propellant valve.

Disruption mitigation↗

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

he LBNF absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF absorber radioactive water (RAW) cooling system which is designed as per ASME B31.3 normal fluid service. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 µs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were compared to allowable limits.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pressure Spike in The LBNF Absorber Core s Gun Drilled Cooling Channel from an Accident Beam Pulse

The LBNF Absorber consists of thirteen 6061-T6 aluminum core blocks. The core blocks are water cooled with de-ionized (DI) water which becomes radioactive during beam operations. The cooling water flows through gun-drilled channels in the core blocks. The cooling water is supplied by the LBNF Absorber Radioactive Water (RAW) cooling system which is designed as per ASME B31.3 Normal Fluid Service [1]. An uninhibited beam accident pulse striking the water channels was identified as a credible accident scenario. In this study, it is assumed that the beam pulse hits the Absorber directly without interacting with any of the other upstream beamline components. The beam parameters used for the LBNF beam are 120 GeV, 2.4 MW with a 1.2 s cycle time. The accident pulse lasts for 10 μs. The maximum energy is deposited in the 3rd aluminum core block. For the sake of simplicity, it is assumed that the accident pulse strikes the 1 in. ID water channel directly. The analysis here simulates the pressure rise in the water during and after the beam pulse and its effects on the aluminum piping components that deliver water to the core blocks. The weld strengths as determined by the Load and Resistance Factor Design (LRDF) and the Allowable Strength Design (ASD) are compared to the forces generated in the weld owing to the pressure spike. A transient structural analysis was used to determine the equivalent membrane, peak, and bending stresses and they were com-pared to allowable limits.

43 PARTICLE ACCELERATORS↗