Search NASA⌕ Search

SEARCH · Search NASA

Results for “Low Precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Fabrication of silicon-tipped fiber-optic temperature sensors using aerogel-assisted glass soldering with precise laser heating

We demonstrate the fabrication of fiber-optic Fabry–Perot interferometer (FPI) temperature sensors by bonding a small silicon diaphragm to the tip of an optical fiber using low melting point glass powders heated by a 980 nm laser on an aerogel substrate. The heating laser is delivered to the silicon FPI using an optical fiber, while the silicon temperature is being monitored using a 1550 nm white-light system, providing localized heating with precise temperature control. The use of an aerogel substrate greatly improves the heating efficiency by reducing the thermal loss of the bonding parts to the ambient environment. A desirable temperature for bonding can be achieved with relatively small heating laser power. The bonding process is carried out in an open space at room temperature for convenient optical alignment. The precise temperature control ensures minimum perturbation to the optical alignment and no induced thermal damage to the optical parts during the bonding process. For demonstration, we fabricated a low-finesse and high-finesse silicon FPI sensor and characterized their measurement resolution and temperature capability. The results show that the fabrication method has a good potential for high-precision fabrication of fiber-optic sensors.

Sheng, Qiwen↗

Precise Timing Based on Pulsar Observation for Grid Synchronization

While Global Positioning System signals are widely used as the synchronized timing Sources for wide-area measurement systems for power grid monitoring and control, they are vulnerable to failures and malicious attacks. To address this Problem, an alternative kind of timing sources, the millisecond pulsars, were proposed to serve the power grid as they are more precise and physically indestructible. Millisecond pulsars are a kind of neutron stars that emit radio pulse signals that have extremely stable periods of milliseconds. However, the observed pulse Signals from pulsars cannot be directly used for timing because of their low signal-to-noise ratio and the dispersion effects of interstellar medium. In this paper, the precise timing method based on pulsar observation data is proposed to interpret the pulsar observation data and therefrom to generate precise timing signal for the power grid synchronization. In our proposed method,. incoherent de-dispersion is used on the observation data to mitigate the effect of interstellar medium. dispersion. Then spectrum analysis and segment folding are used to precisely estimate the local pulsar period. Finally the standard pulse per second signal is generated from. the estimated pulsar period and its precision. is analyzed. Experiments with the observation data of the pulsar based timing signal can be more accurate compared to GPS timing signals.

Luo, Xiqian↗

Tuning Phonon Energies in Lanthanide‐doped Potassium Lead Halide Nanocrystals for Enhanced Nonlinearity and Upconversion

Abstract Optical applications of lanthanide‐doped nanoparticles require materials with low phonon energies to minimize nonradiative relaxation and promote nonlinear processes like upconversion. Heavy halide hosts offer low phonon energies but are challenging to synthesize as nanocrystals. Here, we demonstrate the size‐controlled synthesis of low‐phonon‐energy KPb 2 X 5 (X=Cl, Br) nanoparticles and the ability to tune nanocrystal phonon energies as low as 128 cm −1 . KPb 2 Cl 5 nanoparticles are moisture resistant and can be efficiently doped with lighter lanthanides. The low phonon energies of KPb 2 X 5 nanoparticles promote upconversion luminescence from higher lanthanide excited states and enable highly nonlinear, avalanche‐like emission from KPb 2 Cl 5 : Nd 3+ nanoparticles. The realization of nanoparticles with tunable, ultra‐low phonon energies facilitates the discovery of nanomaterials with phonon‐dependent properties, precisely engineered for applications in nanoscale imaging, sensing, luminescence thermometry and energy conversion.

Zhang, Zhuolei↗

Flavor-dependent radiative corrections in coherent elastic neutrino-nucleus scattering

We calculate coherent elastic neutrino-nucleus scattering cross sections on spin-0 nuclei (e.g. 40 Ar and 28 Si) at energies below 100 MeV within the Standard Model and account for all effects of permille size. We provide a complete error budget including uncertainties at nuclear, nucleon, hadronic, and quark levels separately as well as perturbative error. Our calculation starts from the four-fermion effective field theory to explicitly separate heavy-particle mediated corrections (which are absorbed by Wilson coefficients) from light-particle contributions. Electrons and muons running in loops introduce a non- trivial dependence on the momentum transfer due to their relatively light masses. These same loops, and those mediated by tau leptons, break the flavor universality because of mass-dependent electromagnetic radiative corrections. Nuclear physics uncertainties significantly cancel in flavor asymmetries resulting in subpercent relative errors. We find that for low neutrino energies, the cross section can be predicted with a relative precision that is competitive with neutrino-electron scattering. We highlight potentially useful applications of such a precise cross section prediction ranging from precision tests of the Standard Model, to searches for new physics and to the monitoring of nuclear reactors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ecologically-Informed Precision Conservation: A framework for increasing biodiversity in intensively managed agricultural landscapes with minimal sacrifice in crop production

Conservation actions are urgently needed to tackle biodiversity loss in intensively managed agricultural landscapes. Production lands are usually heterogeneous and contain low-yield areas that can be set aside for biodiversity conservation without serious yield losses. Here, we introduce Ecologically-Informed Precision Conservation, a framework that integrates yield mapping and ecological theory to select the best areas to create new set-asides while ensuring high crop yields at the farm/landscape level. Long-term yield maps can be generated using globally available satellite data and basic information on field/farm crop yield from farmers. Ecological principles are then used to select the subset of areas with the highest potential for biodiversity conservation by prioritising those that increase connectivity, maximise habitat heterogeneity and decrease landscape grain size. Here, the created non-crop habitats can be permanent and thus ensure biodiversity support over time. In addition, agricultural management efficiency can be enhanced by improving field shapes. The framework provides the basis for a practical, user-friendly tool that informs all interested stakeholders on how to rationalise existing agricultural landscapes using already-existing farming systems and available technologies. High cost-effectiveness from an economic and conservation perspective, along with the creation of heterogeneous non-crop habitats, make our framework a promising solution to re-design agricultural landscapes.

Precision agriculture↗

Time series anomaly detection in power electronics signals with recurrent and ConvLSTM autoencoders

The anomalies in the high voltage converter modulator (HVCM) remain a major down time for the spallation neutron source facility, that delivers the most intense neutron beam in the world for scientific materials research. In this work, we propose neural network architectures based on Recurrent AutoEncoders (RAE) to detect anomalies ahead of time in the power signals coming from the HVCM. Bi-directional gated recurrent unit, bi-directional long-short term memory (LSTM), and convolutional LSTM (ConvLSTM) are developed, trained, and tested using real experimental signals from the HVCM module. The results show a good performance of the proposed RAE models, achieving precision up to 91%, recall up to 88%, false omission rate as low as 20% (i.e. 80% of the anomalies were detected), and area under the ROC curve up to 0.9. The three RAE models provide very comparable performance, with LSTM showing slightly better performance than GRU and ConvLSTM. The RAE models are benchmarked against other anomaly detection methods, including isolation forest, support vector machine, local outlier factor, feedforward and convolutional autoencoders, and others; showing a better performance. Here, the results of this study demonstrate the promising potential of RAE in anomaly detection for real-world power systems, and for increasing the reliability of the HVCM modules in the spallation neutron source.

42 ENGINEERING↗

Sympathetic cooling of positrons to cryogenic temperatures for antihydrogen production

The positron, the antiparticle of the electron, predicted by Dirac in 1931 and discovered by Anderson in 1933, plays a key role in many scientific and everyday endeavours. Notably, the positron is a constituent of antihydrogen, the only long-lived neutral antimatter bound state that can currently be synthesized at low energy, presenting a prominent system for testing fundamental symmetries with high precision. Here, we report on the use of laser cooled Be + ions to sympathetically cool a large and dense plasma of positrons to directly measured temperatures below 7 K in a Penning trap for antihydrogen synthesis. This will likely herald a significant increase in the amount of antihydrogen available for experimentation, thus facilitating further improvements in studies of fundamental symmetries.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Latest results of the Muon g-2 experiment at Fermilab

The muon magnetic anomaly, aμ = g - 2/ 2, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. The Muon g − 2 experiment at Fermilab aims to measure aμ with a final accuracy of 140 parts per billion (ppb). The experiment is based on the measurement of the muon spin anomalous precession frequency, ωa, in a magnetic field. The first result of the experiment, based on the 2018 data-taking campaign, was published in 2021 and it confirmed the previous result obtained at Brookhaven National Laboratory with a similar sensitivity of 460 ppb. In this proceeding, the result based on the 2019 and 2020 datasets is presented and the improvement in the accuracy with respect to the 2018 dataset are discussed.

Sorbara, Matteo [INFN, Rome2; Rome U., Tor Vergata↗

A sub-picosecond digital clock monitoring system

We describe a low-cost system designed to monitor wander in digital clocks with a precision of ≤ 1 ps. With this system we have shown that it is possible to track phase variations at the sub-picosecond level by adding noise to a reference clock. As in many cases where a clock is part of a complex distribution network small changes in temperature and other effects can lead to small changes in the clock's phase. As a further demonstration of the system, we have used it to measure the phase changes induced in optical signals in fibers.

47 OTHER INSTRUMENTATION↗

Design and characterization of a phonon-mediated cryogenic particle detector with an eV-scale threshold and 100 keV-scale dynamic range

We present the design and characterization of a cryogenic phonon-sensitive Si detector exploiting the Neganov-Tromov-Luke effect to detect single-charge excitations. This device achieved 2.65(2) eV phonon energy resolution when operated without a voltage bias across the crystal and a corresponding charge resolution of 0.03 electron-hole pairs at 100 V bias. With a continuous-readout data acquisition system and an oine optimum-filter trigger, we obtain a 9.2 eV threshold with a trigger rate of the order of 20 Hz. The detector's energy scale is calibrated up to 120 keV using an energy estimator based on the pulse area. The high performance of this device allows its application to different fields where excellent energy resolution, low threshold, and large dynamic range are required, including dark matter searches, precision measurements of coherent neutrino-nucleus scattering, and ionization yield measurements.

Ren, R↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗

Lowest-order QED radiative corrections in unpolarized elastic electron–deuteron scattering beyond the ultra-relativistic limit for the proposed deuteron charge radius measurement at Jefferson laboratory

Analogous to the well-known proton charge radius puzzle, a similar puzzle exists for the deuteron charge radius, r d . There are discrepancies observed in the results of r d , measured from electron-deuteron (e - d) scattering experiments, as well as from atomic spectroscopy. In order to help resolve the charge radius puzzle of the deuteron, the PRad collaboration at Jefferson Lab has proposed an experiment for measuring r d , named DRad. This experiment is designed to measure the unpolarized elastic e - d scattering cross section in a low-Q 2 region. To extract the cross section with a high precision, having reliable knowledge of QED radiative corrections is important. Here, in this paper, we present complete numerical calculations of the lowest-order radiative corrections in e - d scattering for the DRad kinematics. The calculations have been performed within a covariant formalism and beyond the ultra-relativistic approximation ($m^2_e$ $\ll$ Q 2 ). Besides, we present a systematic uncertainty on r d arising from higher-order radiative corrections, estimated based on our cross-section results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the W-boson angular coefficients and transverse momentum in pp collisions at s=13 TeV with the ATLAS detector

The angular distributions of Drell–Yan lepton pairs provide sensitive probes of the underlying dynamics of quantum chromodynamics (QCD) effects in vector-boson production. This paper presents for the first time the measurement of the full set of angular coefficients together with the differential cross-section as a function of the transverse momentum of the W boson, in the full phase space of the decay leptons. The measurements are performed separately for the W-$$W^-$$ and W+$$W^+$$ channels. The analysis uses proton–proton collision data recorded by the ATLAS experiment at the Large Hadron Collider in 2017 and 2018, during special low-luminosity runs with a reduced number of interactions per bunch crossings (pile-up). The data correspond to an integrated luminosity of 338 pb-1$$^{-1}$$ at a centre-of-mass energy of s=13$$\sqrt{s} = 13$$ TeV. The low pile-up environment provides excellent experimental conditions for high-precision measurements of W-boson production. All results agree with theoretical predictions incorporating finite-order QCD corrections up to order αS2$$\alpha _S^2$$.

Aad, G↗

Interfacial Effects on Transport Coefficient Measurements in Li-ion Battery Electrolytes

Development of Li + -containing electrolytes with improved transport properties requires reliable, reproducible, and ideally low volume techniques to rigorously understand ion-transport with varying composition. Precisely measuring the complete set of transport coefficients in liquid electrolytes under battery-relevant operating conditions is difficult and the reliability of these methods are sparsely described in electrolyte transport literature. In this work, we apply a potentiostatic polarization-based transport characterization approach typically used for polymer electrolytes to liquid electrolyte systems in an attempt to fully measure all transport coefficients (conductivity, total salt diffusion coefficient, thermodynamic factor and transference number) for the model system of LiPF 6 in an ethylene carbonate—ethyl methyl carbonate (EC:EMC) mixture. Using systematic timescale and statistical analyses, we find that transport coefficients measured using potentiostatic polarization of Li-Li symmetric cells exhibit strong correlation to Li electrode interfacial resistance, indicating that such methods are probing both bulk and interfacial phenomena. This reveals a major roadblock in characterizing electrolyte systems where the interfacial resistance is significantly larger than ohmic electrolyte resistance. As a result, we find that methods that rely on potentiostatic Li metal stripping/plating do not readily result in reliable liquid electrolyte transport coefficients, unlike similar methods for solid polymer electrolytes, where interfacial resistances are typically smaller than electrolyte resistances at the elevated temperatures typically of interest for such electrolytes.

25 ENERGY STORAGE↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon g - 2 experiment at Fermilab

The muon magnetic anomaly aµ = (gµ - 2)/2 is a low-energy observable,which can be both measured and computed to high precision, making ita sensitive test of the Standard Model (SM). In April 2021, the E989 Collaborationat Fermilab National Accelerator Laboratory (FNAL) published the first resultbased on the first year of data taking (Run-1), and in August 2023 a new resultwas published based on two more years of data taking (Run-2 and Run-3). Thenew result was in agreement with the first one and with the previous experimentat Brookhaven National Laboratory (BNL), and the combination of these resultsbrought the uncertainty on the experimental measurement of aµ to the unprecedentedvalue of 0.19 parts per million (ppm). This paper will present details aboutthe improvements and upgrades since the 2021 result, and it will describe the finalstatistical and systematic sources of uncertainty on .a in the 2023 result.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Current Status of Developing Ultrafast Mega-electron-volt Electron Microsope

Recent studies of ultrafast electron microscopy (UEM) techniques show the use of short bunches of relativistic electrons is promising for the development of a new instrument for imaging various materials. Compared to conventional electron microscopes, the main advantage of UEMs with the electron energy of a few MeV is the possibility to study thick samples. We will discuss the progress of UEM design to date, the principal challenges on the way to a high resolution, and possible methods for their mitigation including the design of low-aberration magnetic optics, RF and mechanical subsystems with high stability, and precise collimation of electrons scattered in the samples.

43 PARTICLE ACCELERATORS↗

Measurement of the anomalous spin precession frequency $\omega_a$ in the Muon $g-2$ experiment at Fermilab

The muon anomaly, $a_\mu=(g_{\mu}-2)/2$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model (SM) and a probe for new physics. The current discrepancy between the experimental value and the Standard Model calculation from the Muon $g-2$ Theory Initiative is $a_{\mu}^{exp}-a_{\mu}^{SM}=(251\pm59)\cdot10^{-11}$, with a significance of $4.2\,\sigma$.The Fermilab E989 experiment aims, with the full statistical power, to improve by a factor of four the precision of the measurement.In April 2021 the collaboration published the first measurement, based on the first year of data taking.This paper will present the status of the measurement of the anomalous muon spin precession frequency, $\omega_a$, performed on the datasets collected during Run-2 and Run-3 (2019 and 2020 campaigns), with a preliminary projection of the systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MassIVE MSV000094084 - Data files for manuscript - Selected ion monitoring for orbitrap-based metabolomics: Please open README-data-for-SIM-paper-20240210.doc for details.

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage. Please open README-data-for-SIM-paper-20240210.doc for details. [doi:10.25345/C5JH3DD3K] [dataset license: CC0 1.0 Universal (CC0 1.0)]

Rabinowitz, Joshua↗