Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC SENSING SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Application of high stability oscillators to radio science experiments using deep space probes

The microwave telecommunication links between the earth and deep space probes have long been used to conduct radio science experiments which take advantage of the phase coherency and stability of these links. These experiments measure changes in the phase delay of the signals to infer electrical, magnetic and gravitational properties of the solar system environment and beyond through which the spacecraft and radio signals pass. The precision oscillators, from which the phase of the microwave signals are derived, play a key role in the stability of these links and therefore the sensitivity of these measurements. These experiments have become a driving force behind recent and future improvements in the Deep Space Network and spacecraft oscillators and frequency and time distribution systems. Three such experiments which are key to these improvements are briefly discussed and relationship between their sensitivity and the signal phase stability is described. The first is the remote sensing of planetary atmospheres by occultation in which the radio signal passes through the atmosphere and is refracted causing the signal pathlength to change from which the pressure and the temperature of the atmosphere can be derived. The second experiment is determination of the opacity of planetary rings by passage of the radio signals through the rings. The third experiment is the research for very low frequency gravitational radiation. The fractional frequency variation of the signal is comparable to the spatial strain amplitude the system is capable of detecting. A summary of past results and future possibilities for these experiments are presented.

Kursinski, Emil R.↗

Demonstration of high sensitivity laser ranging system

We report on a high sensitivity semiconductor laser ranging system developed for the Gravity and Magnetic Earth Surveyor (GAMES) for measuring variations in the planet's gravity field. The GAMES laser ranging instrument (LRI) consists of a pair of co-orbiting satellites, one which contains the laser transmitter and receiver and one with a passive retro-reflector mounted in an drag-stabilized housing. The LRI will range up to 200 km in space to the retro-reflector satellite. As the spacecraft pair pass over the spatial variations in the gravity field, they experience along-track accelerations which change their relative velocity. These time displaced velocity changes are sensed by the LRI with a resolution of 20-50 microns/sec. In addition, the pair may at any given time be drifting together or apart at a rate of up to 1 m/sec, introducing a Doppler shift into the ranging signals. An AlGaAs laser transmitter intensity modulated at 2 GHz and 10 MHz is used as fine and medium ranging channels. Range is measured by comparing phase difference between the transmit and received signals at each frequency. A separate laser modulated with a digital code, not reported in this paper, will be used for coarse ranging to unambiguously determine the distance up to 200 km.

Millar, Pamela S.↗

KLASS: Kennedy Launch Academy Simulation System

Software provides access to many sophisticated scientific instrumentation (Scanning Electron Microscope (SEM), a Light Microscope, a Scanning Probe Microscope (covering Scanning Tunneling, Atomic Force, and Magnetic Force microscopy), and an Energy Dispersive Spectrometer for the SEM). Flash animation videos explain how each of the instruments work. Videos on how they are used at NASA and the sample preparation. Measuring and labeling tools provided with each instrument. Hands on experience of controlling the virtual instrument to conduct investigations, much like the real scientists at NASA do. Very open architecture. Open source on SourceForge. Extensive use of XML Target audience is high school and entry-level college students. "Many beginning students never get closer to an electron microscope than the photos in their textbooks. But anyone can get a sense of what the instrument can do by downloading this simulator from NASA's Kennedy Space Center." Science Magazine, April 8th, 2005

Garner, Lesley C.↗

Integrating Electromagnetic Acoustic Transducers in a Modular Robotic Gripper for Inspecting Tubular Components

Tubular structures are critical components in infrastructure such as power plants. Throughout their life, they are subjected to extreme conditions or suffer from defects such as corrosion and cracks. Although regular inspection of these components is necessary, such inspection is limited by safety-related risks and limited access for human inspection. Robots can provide a solution for automatic inspection. The main challenge, however, lies in integrating sensors for nondestructive evaluation with robotic platforms. As part of developing a versatile lizard-inspired tube inspector robot, in this study the authors propose to integrate electromagnetic acoustic transducers into a modular robotic gripper for use in automated ultrasonic inspection. In particular, spiral coils with cylindrical magnets are integrated into a novel friction-based gripper to excite Lamb waves in thin cylindrical structures. To evaluate the performance of the integrated sensors, the gripper was attached to a robotic arm manipulator and tested on pipes of different outer diameters. Two sets of tests were carried out on both defect-free pipes and pipes with simulated defects, including surface partial cracking and corrosion. The inspection results indicated that transmitted and received signals could be acquired with an acceptable signal-to-noise ratio in the time domain. Moreover, the simulated defects could be successfully detected using the integrated robotic sensing system.

Materials Science↗

SQMS Quantum R&D in Machine Learning, Optimization and Sensing beyond Fundamental Physics Applications

This newly formed team at SQMS under the Ecosystem Thrust is looking to develop capabilities impacting societal advances outside the core domain of HEP and condensed matter physics. We explicitly leverage the experimental and algorithmic innovations developed across all groups as well as connect to broad-scope external projects of the diverse team of PIs. As the inaugural set of projects, we are studying numerically quantum machine learning models inspired by efficiently trainable echo-state and orthogonal neural networks and developing designs for related experiments to be performed on quantum processors based on SQMS SRF cQED technology and Rigetti s transmon arrays. Investigated models exploit ideas and lessons learned from multiple prior work by SQMS team members in a variety of internal and external activities [R1]. Target initial applications include noisy signal processing, potentially captured by quantum sensors or noisy QPUs, as well as simulation and classification of healthcare data. For instance, image reconstruction of the brain s electrical properties by solving the inverse Maxwell equation problem with uncertainty [R2] through a hybrid quantum-classical physics-informed architecture for time-dependent processes [R3]. The group is also investigating the application and development of novel quantum sensors based on magnetic levitation of a superconducting sphere coupled to a superconducting qubit. This coupling enables high-precision measurements of the position of the sphere, which can be used for sensitive detection of forces, enabling practical applications such as gravimetry for geophysics analysis, or accelerometry for GPS-denied navigation [R4] [R1] Rieffel, Eleanor G., Ata Akbari Asanjan, M. Sohaib Alam, Namit Anand, David E. Bernal Neira, Sophie Block, Lucas T. Brady et al. "Assessing and advancing the potential of quantum computing: A NASA case study." Future Generation Computer Systems (2024). [R2] Yu, X., Serrall s, J.E., Giannakopoulos, I.I., Liu, Z., Daniel, L., Lattanzi, R. and Zhang, Z., 2023. Pifon-ept: Mr-based electrical property tomography using physics-informed fourier networks. IEEE Journal on Multiscale and Multiphysics Computational Techniques. [R3] Wudarski, Filip, Daniel OConnor, Shaun Geaney, Ata Akbari Asanjan, Max Wilson, Elena Strbac, P. Aaron Lott, and Davide Venturelli. "Hybrid quantum-classical reservoir computing for simulating chaotic systems." arXiv preprint arXiv:2311.14105 (2023). [R4] Higgins, Gerard, Saarik Kalia, and Zhen Liu. "Maglev for dark matter: Dark-photon and axion dark matter sensing with levitated superconductors." Physical Review D 109.5 (2024): 055024.

Venturelli, Davide↗

Carbon-13 Radiofrequency Amplification by Stimulated Emission of Radiation of the Hyperpolarized Ketone and Hemiketal Forms of Allyl [1- 13 C]Pyruvate

13 C hyperpolarized pyruvate is an emerging MRI contrast agent for sensing molecular events in cancer and other diseases with aberrant metabolic pathways. This metabolic contrast agent can be produced via several hyperpolarization techniques. Despite remarkable success in research settings, widespread clinical adoption faces substantial roadblocks because the current sensing technology utilized to sense this contrast agent requires the excitation of 13 C nuclear spins that also need to be synchronized with MRI field gradient pulses. Here, we demonstrate sensing of hyperpolarized allyl [1- 13 C]pyruvate via the stimulated emission of radiation that mitigates the requirements currently blocking broader adoption. Specifically, 13 C Radiofrequency Amplification by Stimulated Emission of Radiation ( 13 C RASER) was obtained after pairwise addition of parahydrogen to a pyruvate precursor, detected in a commercial inductive detector with a quality factor (Q) of 32 for sample concentrations as low as 0.125 M with 13 C polarization of 4%. Moreover, parahydrogen-induced polarization allowed for the preparation of a mixture of ketone and hemiketal forms of hyperpolarized allyl [1- 13 C]pyruvate, which are separated by 10 ppm in 13 C NMR spectra. This is a good model system to study the simultaneous 13 C RASER signals of multiple 13 C species. This system models the metabolic production of hyperpolarized [1- 13 C]lactate from hyperpolarized [1- 13 C]pyruvate, which has a similar chemical shift difference. Our results show that 13 C RASER signals can be obtained from both species simultaneously when the emission threshold is exceeded for both species. On the other hand, when the emission threshold is exceeded only for one of the hyperpolarized species, 13 C stimulated emission is confined to this species only, therefore enabling the background-free detection of individual hyperpolarized 13 C signals. Furthermore, the reported results pave the way to novel sensing approaches of 13 C hyperpolarized pyruvate, potentially unlocking hyperpolarized 13 C MRI on virtually any MRI system–an attractive vision for the future molecular imaging and diagnostics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NASA Tech Briefs, December 2009

Topics include: A Deep Space Network Portable Radio Science Receiver; Detecting Phase Boundaries in Hard-Sphere Suspensions; Low-Complexity Lossless and Near-Lossless Data Compression Technique for Multispectral Imagery; Very-Long-Distance Remote Hearing and Vibrometry; Using GPS to Detect Imminent Tsunamis; Stream Flow Prediction by Remote Sensing and Genetic Programming; Pilotless Frame Synchronization Using LDPC Code Constraints; Radiometer on a Chip; Measuring Luminescence Lifetime With Help of a DSP; Modulation Based on Probability Density Functions; Ku Telemetry Modulator for Suborbital Vehicles; Photonic Links for High-Performance Arraying of Antennas; Reconfigurable, Bi-Directional Flexfet Level Shifter for Low-Power, Rad-Hard Integration; Hardware-Efficient Monitoring of I/O Signals; Video System for Viewing From a Remote or Windowless Cockpit; Spacesuit Data Display and Management System; IEEE 1394 Hub With Fault Containment; Compact, Miniature MMIC Receiver Modules for an MMIC Array Spectrograph; Waveguide Transition for Submillimeter-Wave MMICs; Magnetic-Field-Tunable Superconducting Rectifier; Bonded Invar Clip Removal Using Foil Heaters; Fabricating Radial Groove Gratings Using Projection Photolithography; Gratings Fabricated on Flat Surfaces and Reproduced on Non-Flat Substrates; Method for Measuring the Volume-Scattering Function of Water; Method of Heating a Foam-Based Catalyst Bed; Small Deflection Energy Analyzer for Energy and Angular Distributions; Polymeric Bladder for Storing Liquid Oxygen; Pyrotechnic Simulator/Stray-Voltage Detector; Inventions Utilizing Microfluidics and Colloidal Particles; RuO2 Thermometer for Ultra-Low Temperatures; Ultra-Compact, High-Resolution LADAR System for 3D Imaging; Dual-Channel Multi-Purpose Telescope; Objective Lens Optimized for Wavefront Delivery, Pupil Imaging, and Pupil Ghosting; CMOS Camera Array With Onboard Memory; Quickly Approximating the Distance Between Two Objects; Processing Images of Craters for Spacecraft Navigation; Adaptive Morphological Feature-Based Object Classifier for a Color Imaging System; Rover Slip Validation and Prediction Algorithm; Safety and Quality Training Simulator; Supply-Chain Optimization Template; Algorithm for Computing Particle/Surface Interactions; Cryogenic Pupil Alignment Test Architecture for Aberrated Pupil Images; and Thermal Transport Model for Heat Sink Design.

Source record↗

Autonomous phototaxis of hydrogel swimmers

The design of synthetic soft matter capable of emulating the complex behaviors of living organisms, such as sensing and adapting to their environment, remains an important challenge in developing biomimetic materials. Functionalized hydrogels are ideal candidates for such materials since they are highly responsive to their environment and can be operated in water. In this work, we investigate a hybrid bonding hydrogel composed of peptide amphiphile supramolecular nanofibers covalently attached to a photoresponsive network, in which high-aspect-ratio ferromagnetic nanowires are aligned along the length of the sample, designed to swim under oscillating magnetic fields. This hybrid hydrogel swimmer can autonomously swim toward a light source by utilizing photoinduced interactions between supramolecular and covalent networks reminiscent of phototactic swimming in living systems. Using a combination of experimental techniques and a continuum model incorporating photochemistry, magnetoelasticity, and hydrodynamics, we explain the swimming mechanism and predict phototactic behavior. Our work highlights the potential role of hybrid bonding polymers, which leverage the interplay between supramolecular assemblies and covalent networks. We demonstrate how these polymers can be tailored to react dynamically to their environment, paving the way for developing intelligent and autonomous robotic systems.

Science & Technology - Other Topics↗

Measurement and Simulation of the Magnetic Fields from a 555 Timer Integrated Circuit Using a Quantum Diamond Microscope and Finite-Element Analysis

Quantum diamond microscope (QDM) magnetic field imaging is an emerging interrogation and diagnostic technique for integrated circuits (ICs). To date, the ICs measured with a QDM have been either too complex for us to predict the expected magnetic fields and benchmark the QDM performance or too simple to be relevant to the IC community. In this paper, we establish a 555 timer IC as a “model system” to optimize QDM measurement implementation, benchmark performance, and assess IC device functionality. To validate the magnetic field images taken with a QDM, we use a spice electronic circuit simulator and finite-element analysis (FEA) to model the magnetic fields from the 555 die for two functional states. Furthermore, we compare the advantages and the results of three IC-diamond measurement methods, confirm that the measured and simulated magnetic images are consistent, identify the magnetic signatures of current paths within the device, and discuss using this model system to advance QDM magnetic imaging as an IC diagnostic tool.

74 ATOMIC AND MOLECULAR PHYSICS↗

Surpassing the Energy Resolution Limit with Ferromagnetic Torque Sensors

We discuss the fundamental noise limitations of a ferromagnetic torque sensor based on a levitated magnet in the tipping regime. We evaluate the optimal magnetic field resolution taking into account the thermomechanical noise and the mechanical detection noise at the standard quantum limit. We find that the energy resolution limit, pointed out in recent literature as a relevant benchmark for most classes of magnetometers, can be surpassed by many orders of magnitude. Moreover, similarly to the case of a ferromagnetic gyroscope, it is also possible to surpass the standard quantum limit for magnetometry with independent spins, arising from spin-projection noise. Our finding indicates that magnetomechanical systems optimized for magnetometry can achieve a magnetic field resolution per unit volume several orders of magnitude better than any conventional magnetometer. Here, we discuss possible implications, focusing on fundamental physics problems such as the search for exotic interactions beyond the standard model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NASA Tech Briefs, July 2007

Topics covered include: Miniature Intelligent Sensor Module; "Smart" Sensor Module; Portable Apparatus for Electrochemical Sensing of Ethylene; Increasing Linear Dynamic Range of a CMOS Image Sensor; Flight Qualified Micro Sun Sensor; Norbornene-Based Polymer Electrolytes for Lithium Cells; Making Single-Source Precursors of Ternary Semiconductors; Water-Free Proton-Conducting Membranes for Fuel Cells; Mo/Ti Diffusion Bonding for Making Thermoelectric Devices; Photodetectors on Coronagraph Mask for Pointing Control; High-Energy-Density, Low-Temperature Li/CFx Primary Cells; G4-FETs as Universal and Programmable Logic Gates; Fabrication of Buried Nanochannels From Nanowire Patterns; Diamond Smoothing Tools; Infrared Imaging System for Studying Brain Function; Rarefying Spectra of Whispering-Gallery-Mode Resonators; Large-Area Permanent-Magnet ECR Plasma Source; Slot-Antenna/Permanent-Magnet Device for Generating Plasma; Fiber-Optic Strain Gauge With High Resolution And Update Rate; Broadband Achromatic Telecentric Lens; Temperature-Corrected Model of Turbulence in Hot Jet Flows; Enhanced Elliptic Grid Generation; Automated Knowledge Discovery From Simulators; Electro-Optical Modulator Bias Control Using Bipolar Pulses; Generative Representations for Automated Design of Robots; Mars-Approach Navigation Using In Situ Orbiters; Efficient Optimization of Low-Thrust Spacecraft Trajectories; Cylindrical Asymmetrical Capacitors for Use in Outer Space; Protecting Against Faults in JPL Spacecraft; Algorithm Optimally Allocates Actuation of a Spacecraft; and Radar Interferometer for Topographic Mapping of Glaciers and Ice Sheets.

Source record↗

Redshifts of high-temperature emission lines in the far-ultraviolet spectra of late-type stars

High-dispersion IUE spectra of six late-type stars exhibit small but statistically significant differential redshifts of high-temperature emission lines, like Si IV and C IV, with respect to low-temperature lines like S I and O I. A well-exposed, small-aperture spectrum of the active chromosphere binary Capella (Alpha Aurigae A: G6 II+F9 III) establishes that the high-temperature lines are redshifted in an absolute sense with respect to the accurately determined photospheric velocity of the system at single-line phase 0.50. Several possible explanations for the stellar redshifts are discused, including a warm wind (100,000 K) in which aparent redshifts are produced in optically thick lines by an accelerating outfow, and the downflowing component of a vertical circulation system for which the up-leg portion of the flow is too cool, too hot, or too tenuous to be visible in Si IV and C IV. If the second scenario is true, the stellar redshifts may provide an important phenomenological link to the downflows observed in 100,000 K species over magnetic active regions in the sun.

Ayres, T. R.↗

13 C Radiofrequency Amplification by Stimulated Emission of Radiation Threshold Sensing of Chemical Reactions

Conventional nuclear magnetic resonance (NMR) enables detection of chemicals and their transformations by exciting nuclear spin ensembles with a radio-frequency pulse followed by detection of the precessing spins at their characteristic frequencies. The detected frequencies report on chemical reactions in real time and the signal amplitudes scale with concentrations of products and reactants. Here, we employ Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), a quantum phenomenon producing coherent emission of 13 C signals, to detect chemical transformations. The 13 C signals are emitted by the negatively hyperpolarized biomolecules without external radio frequency pulses and without any background signal from other, nonhyperpolarized spins in the ensemble. Here, we studied the hydrolysis of hyperpolarized ethyl-[1- 13 C]acetate to hyperpolarized [1- 13 C]acetate, which was analyzed as a model system by conventional NMR and 13 C RASER. The chemical transformation of 13 C RASER-active species leads to complete and abrupt disappearance of reactant signals and delayed, abrupt reappearance of a frequency-shifted RASER signal without destroying 13 C polarization. Further, the experimentally observed “quantum” RASER threshold is supported by simulations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Plasma Imaging, LOcal Measurement, and Tomographic Experiment (PILOT): A Mission Concept for Transformational Multi-Scale Observations of Mass and Energy Flow Dynamics in Earth’s Magnetosphere

We currently do not understand the fundamental physical processes that govern mass and energy flow through the Earth’s magnetosphere. Knowledge of these processes is critical to understanding the mass loss rate of Earth’s atmosphere, as well as for determining the role that a planetary magnetic field plays in atmospheric retention, and therefore habitability, for Earth-like planets beyond the solar system. Mass and energy flow processes are challenging to determine at Earth in part because Earth’s planetary magnetic field creates a complex “system of systems” composed of interdependent plasma populations and overlapping spatial regions that perpetually exchange mass and energy across a broad range of temporal and spatial scales. Further, the primary mass carrier in the magnetosphere is cold plasma (as cold as ~0.1 eV), which is invisible to many space-borne instruments that operate in the inner magnetosphere. The Plasma Imaging LOcal and Tomographic experiment (PILOT) mission concept, described here, provides the transformational multi-scale observations required to answer fundamental open questions about mass and energy flow dynamics in the Earth’s magnetosphere. PILOT uses a constellation of spacecraft to make radio tomographic, remote sensing, and in-situ measurements simultaneously, fully capturing cold plasma mass dynamics and its impact on magnetospheric systems over an unprecedented range of spatial and temporal scales. This article details the scientific motivation for the PILOT mission concept as well as a potential mission implementation.

79 ASTRONOMY AND ASTROPHYSICS↗

Tunable Electro-optic modulators for lidar systems and atmospheric applications

In global sensing applications using different types of lidars, the spectral range and fine frequency coverages are often limited because of the finite tunabilities of molecular lasers and the number of molecular species that are available. To overcome the above obstacle, we have proposed new broadband frequency tunable electro-optic (EO) modulators that can cover a wide range from the mid-infrared to the visible as lidar sources in atmospheric sensing applications such as high resolution atmospheric molecular spectroscopy, Differential Absorption Lidar (DIAL), and laser radar imaging. The configuration of the proposed new tunable EO modulators includes an electro-optic active crystal element surrounded by a ferrite tuning element which is placed inside a microwave waveguide. The tuning is provided by an external magnetic field, which is either longitudinal or transverse, and the modulator can be either single sideband type or a double sideband type depending on the application required for the spectral purity of the modulator output.

Eng, R. S.↗

Magnetic translator bearings

A magnetic bearing system for enabling translational motion includes a carriage and a shaft for movably supporting the carriage; a first magnetic bearing fixed to one of the carriage and shaft and slidably received in a first channel of the other of the carriage and shaft. The first channel is generally U shaped with two side walls and a back wall. The magnetic bearing includes a pair of spaced magnetic pole pieces, each pole piece having a pair of electromagnetic coils mounted on poles on opposite ends of the pole piece proximate the side walls, and a third electromagnetic coil mounted on a pole of the pole piece proximate the backwall; a motion sensor for sensing translational motion along two axes and rotationally about three axes of the carriage and shaft relative to each other; and a correction circuit responsive to the sensor for generating a correction signal to drive the coils to compensate for any misalignment sensed between the carriage and the shaft.

Hockney, Richard L.↗

Magnetic Solitons and Thickness‐Dependent Magnetization Reversal in Interconnected Helical Nanowire Arrays

By expanding magnetic nanostructures into the third dimension, it is possible to introduce new interactions and realize new forms of magnetic textures and emergent phenomena. Consequently, this unlocks new opportunities for applications in data storage, unconventional computing and sensing by utilizing 3D devices with enhanced functionalities. Connected magnetic nanowires offer a unique platform for applications such as neuromorphic computing due to their tunability and the presence of multiple transport pathways. However to realize this promise, it is necessary to further our understanding of how to locally control the magnetization in 3D, nanowire-based geometries. In this work we show the formation of magnetic domain walls, vortices, anti-vortices, and linked vortex-anti-vortex pairs in interconnected helical nanowire arrays. We show how wire diameter and 3D geometric design can control the states that form and reveal the magnetization reversal mechanism. Hence, we demonstrate this to be a highly tunable system, where the magnetization can be readily reconfigured by an external magnetic field.

3D Nanomagnetism↗

Payload retention device

A payload retention device for grappling and retaining a payload in docked position on a supporting structure in the cargo bay of a space vehicle is presented. The device comprises a two-fault tolerant electromagnetic grappling system comprising electromagnets for attracting and grappling a grapple strike plate affixed to the payload when in proximity thereto and an electromechanical latching assembly comprising a pair of independent latching subassemblies. Each subassembly comprises a set of latching pawls which are driven into latching and unlatching positions relative to a grappled payload by a pair of gearmotors, each equipped with a ratchet clutch drive mechanism which is two-fault tolerant with respect to latching such that only one gearmotor of the four needs to be operational to effect a latch of the payload but is single fault tolerant with respect to release of a latched payload. Sensors are included for automatically sensing the magnetic grappling of a payload and for automatically de-energizing the gearmotors of the latching subassemblies when a latch condition is achieved.

Monford, Leo G., Jr.↗