Measuring Seebeck Coefficients With Large Thermal Gradients

Apparatus takes measurements and analyzes data automatically. Cylindrical sample is pressed between heater and water-cooled baseplate. Thermocouples at opposite ends of sample provide both temperatures and Seeback voltages. Conveniently shaped samples used, and results calculated by microcomputer and printed out.

Wood, C.↗

Measuring Specific Heats at High Temperatures

Flash apparatus for measuring thermal diffusivities at temperatures from 300 to 1,000 degrees C modified; measures specific heats of samples to accuracy of 4 to 5 percent. Specific heat and thermal diffusivity of sample measured. Xenon flash emits pulse of radiation, absorbed by sputtered graphite coating on sample. Sample temperature measured with thermocouple, and temperature rise due to pulse measured by InSb detector.

Vandersande, Jan W.↗

Continuous Carrier Optical Phase Optometric Measurement over Coherent Optical Communication Link

An apparatus for measuring a distance between a first and second terminal includes a frame counter for determining a number of data frames traversing a distance between the first terminal 105 and the second terminal, a frame bit counter for determining a number of data clock bits offset between a transmitted data frame and a concurrently received data frame, a data clock phase detector for determining a phase difference between an RF data clock for the transmitted data frame and an RF data clock for the concurrently received data frame, and an optical carrier phase detector for determining a phase difference between an optical carrier used to transmit the transmitted data frame and an optical carrier for the concurrently received data frame. The distance between the first and second terminal is determined from a round trip transit time T between the first and second terminals.

Yang, Guangning↗

Gel Precursors as Glass and Ceramic Starting Materials for Space Processing Applications Research

The crystallization kinetics and glass forming ability of reluctant glass formers is investigated. This could ultimately aid the formation of bulk samples of unique glass compositions outside of normal glass forming regions allowing the optimization of certain properties of the glass. One important aspect of processing in space is the containerless undercooling of molten substances. Theoretically, the extent of undercooling can be greatly enhanced by solidifying in the absence of heterogeneous nucleation resulting from contact with crucibles or molds. Techniques were established for the measurement of crystallization kinetics and critical cooling rates. The glass formation ability and crystallization kinetics of Ga2O-43CaO and several Al2O3-CaO compositions were measured. An apparatus was set up to measure the temperature of spherical samples on a thermocouple at large cooling rates. The time and temperature of nucleation is recorded and the probability of nucleation at various cooling rates can be measured.

Downs, R. L.↗

Glass Formation in Reluctant Glass Formers

The crystallization kinetics and glass forming ability of reluctant glass formers is investigated. This could ultimately aid the formation of bulk samples of unique glass compositions outside of normal glass forming regions allowing the optimization of certain properties of the glass. One important aspect of processing space is the containerless undercooling of molten substances. Theoretically, the extent of undercooling can be greatly enhanced by solidifying in the absence of heterogeneous nucleation resulting from contact with crucibles or molds. Techniques were established for the measurement of crystallization kinetics and critical cooling rates. The glass formation ability and crystallization kinetics of Ga2O-43CaO and several Al2O3-CaO compositions were measured. An apparatus was set up to measure the temperature of spherical samples on a thermocouple at large cooling rates. The time and temperature of nucleation is recorded and the probability of nucleation at various cooling rates can be measured.

Ethridge, E. C.↗

Instrument accurately measures small temperature changes on test surface

Calorimeter apparatus accurately measures very small temperature rises on a test surface subjected to aerodynamic heating. A continuous thin sheet of a sensing material is attached to a base support plate through which a series of holes of known diameter have been drilled for attaching thermocouples to the material.

Harvey, W. D.↗

Measuring projectile speed

Apparatus uses optoelectric detector to measure station-to-station time-of-flight of small spherical aluminum projectile down steel barrel. Instrument has been used to study impact resistance of composite materials used in aircraft structural research program.

Jordan, J. E.↗

Optoelectronic System Measures Distances to Multiple Targets

An optoelectronic metrology apparatus now at the laboratory-prototype stage of development is intended to repeatedly determine distances of as much as several hundred meters, at submillimeter accuracy, to multiple targets in rapid succession. The underlying concept of optoelectronic apparatuses that can measure distances to targets is not new; such apparatuses are commonly used in general surveying and machining. However, until now such apparatuses have been, variously, constrained to (1) a single target or (2) multiple targets with a low update rate and a requirement for some a priori knowledge of target geometry. When fully developed, the present apparatus would enable measurement of distances to more than 50 targets at an update rate greater than 10 Hz, without a requirement for a priori knowledge of target geometry. The apparatus (see figure) includes a laser ranging unit (LRU) that includes an electronic camera (photo receiver), the field of view of which contains all relevant targets. Each target, mounted at a fiducial position on an object of interest, consists of a small lens at the output end of an optical fiber that extends from the object of interest back to the LRU. For each target and its optical fiber, there is a dedicated laser that is used to illuminate the target via the optical fiber. The targets are illuminated, one at a time, with laser light that is modulated at a frequency of 10.01 MHz. The modulated laser light is emitted by the target, from where it returns to the camera (photodetector), where it is detected. Both the outgoing and incoming 10.01-MHz laser signals are mixed with a 10-MHz local-oscillator to obtain beat notes at 10 kHz, and the difference between the phases of the beat notes is measured by a phase meter. This phase difference serves as a measure of the total length of the path traveled by light going out through the optical fiber and returning to the camera (photodetector) through free space. Because the portion of the path length inside the optical fiber is not ordinarily known and can change with temperature, it is also necessary to measure the phase difference associated with this portion and subtract it from the aforementioned overall phase difference to obtain the phase difference proportional to only the free-space path length, which is the distance that one seeks to measure. Therefore, the apparatus includes a photodiode and a circulator that enable measurement of the phase difference associated with propagation from the LRU inside the fiber to the target, reflection from the fiber end, and propagation back inside the fiber to the LRU. Because this phase difference represents twice the optical path length of the fiber, this phase difference is divided in two before subtraction from the aforementioned total-path-length phase difference. Radiation-induced changes in the photodetectors in this apparatus can affect the measurements. To enable calibration for the purpose of compensation for these changes, the apparatus includes an additional target at a known short distance, located inside the camera. If the measured distance to this target changes, then the change is applied to the other targets.

Liebe, Carl Christian↗

Experimental verification of the thermodynamic properties for a jet-A fuel

Thermodynamic properties for a Jet-A fuel were determined by Shell Development Company in 1970 under a contract for NASA Lewis Research Center. The polynomial fit necessary to include Jet-A fuel (liquid and gaseous phases) in the library of thermodynamic properties of the NASA Lewis Chemical Equilibrium Program is calculated. To verify the thermodynamic data, the temperatures of mixtures of liquid Jet-A injected into a hot nitrogen stream were experimentally measured and compared to those calculated by the program. Iso-octane, a fuel for which the thermodynamic properties are well known, was used as a standard to calibrate the apparatus. The measured temperatures for the iso-octane/nitrogen mixtures reproduced the calculated temperatures except for a small loss due to the non-adiabatic behavior of the apparatus. The measurements for Jet-A were corrected for this heat loss and showed excellent agreement with the calculated temperatures. These experiments show that this process can be adequately described by the thermodynamic properties fitted for the Chemical Equilibrium Program.

Graciasalcedo, Carmen M.↗

Continuous blood densitometry - Fluid shifts after graded hemorrhage in animals

Rapid fluid shifts in four pigs and two dogs subjected to graded hemorrhage are investigated. Arterial blood density (BD), mean arterial pressure (MAP), central venous pressure (CVP), arterial plasma density (PD), hematocrit (Hct) and erythrocyte density were measured. The apparatus and mechancial oscillator technique for measuring density are described. Fluid shifts between red blood cells and blood plasma and alterations in the whole-body-to-large vessel Hct, F(cell) are studied using two models. The bases of the model calculations are discussed. A decrease in MAP, CVP, and BP is detected at the beginning of hemorrhaging; continued bleeding results in further BD decrease correlating with volume displacement. The data reveal that at 15 ml/kg blood loss the mean PD and BD dropped by 0.99 + or - 0.15 and 2.42 + or 0.26 g/liter, respectively, and the Hct dropped by 2.40 + or 0.47 units. The data reveal that inward-shifted fluid has a higher density than normal ultrafiltrate and/or there is a rise in the F(cell) ratio. It is noted that rapid fluid replacement ranged from 5.8 + or - 0.8 to 10.6 + or - 2.0 percent of the initial plasma volume.

Hinghofer-Szalkay, H.↗

An experimental modal testing/identification technique for personal computers

A PC-based system for mode shape identification is evaluated. A time-domain modal identification procedure is utilized to identify the mode shapes of a beam apparatus from discrete time-domain measurements. The apparatus includes a cantilevered aluminum beam, four accelerometers, four low-pass filters, and the computer. The method's algorithm is comprised of an identification algorithm: the Eigensystem Realization Algorithm (ERA) and an estimation algorithm called Minimum Model Error (MME). The identification ability of this algorithm is compared with ERA alone, a frequency-response-function technique, and an Euler-Bernoulli beam model. Detection of modal parameters and mode shapes by the PC-based time-domain system is shown to be accurate in an application with an aluminum beam, while mode shapes identified by the frequency-domain technique are not as accurate as predicted. The new method is shown to be significantly less sensitive to noise and poorly excited modes than other leading methods. The results support the use of time-domain identification systems for mode shape prediction.

Roemer, Michael J.↗

High Temperature W-band Complex Permittivity Measurements of Thermally Cycled Ceramic-Metal Composites: AlN:Mo with 0.25 vol% to 4.0 vol% Mo from 25 °C to 1000 °C in Air

An apparatus for measuring the W-band (75-110GHz) complex permittivity of dielectrics at 1000 °C was developed. This apparatus allows for measurements at approximately twice the temperature of previously published high temperature free-space measurement systems while maintaining similar precision. Challenges were addressed related to high temperature measurements, including temperature uniformity, the accuracy of temperature measurements, and preventing temperature related changes to mm-wave measurement systems. The details of complex permittivity extraction from the measured S-parameters are discussed. Sources of error related to permittivity measurement and mathematical models were identified and are discussed in detail herein. Thermally-cycled, mm-wave absorbing, aluminum nitride ceramic composites containing varying levels of molybdenum additives were measured over the range of 25-1000 °C. These measurements were compared to the same composites before thermal cycling. It was found that ceramic composites are largely stable after thermal cycling in terms of dielectric properties despite the presence of visible surface modifications.

Zane W Cohick↗

Sensing device and method for measuring emission time delay during irradiation of targeted samples

An apparatus for measuring emission time delay during irradiation of targeted samples by utilizing digital signal processing to determine the emission phase shift caused by the sample is disclosed. The apparatus includes a source of electromagnetic radiation adapted to irradiate a target sample. A mechanism generates first and second digital input signals of known frequencies with a known phase relationship, and a device then converts the first and second digital input signals to analog sinusoidal signals. An element is provided to direct the first input signal to the electromagnetic radiation source to modulate the source by the frequency thereof to irradiate the target sample and generate a target sample emission. A device detects the target sample emission and produces a corresponding first output signal having a phase shift relative to the phase of the first input signal, the phase shift being caused by the irradiation time delay in the sample. A member produces a known phase shift in the second input signal to create a second output signal. A mechanism is then provided for converting each of the first and second analog output signals to digital signals. A mixer receives the first and second digital output signals and compares the signal phase relationship therebetween to produce a signal indicative of the change in phase relationship between the first and second output signals caused by the target sample emission. Finally, a feedback arrangement alters the phase of the second input signal based on the mixer signal to ultimately place the first and second output signals in quadrature. Mechanisms for enhancing this phase comparison and adjustment technique are also disclosed.

Danielson, J. D. Sheldon↗

M.I.T. Stirling-cycle heat transfer apparatus

The design and construction of a two-cylinder apparatus to measure heat transfer under conditions of oscillating pressure and oscillating flow such as found in Stirling-cycle machines are described. The apparatus consists of two large single-stage air compressors joined by a rigid drive shaft between the two crack shafts, and is powered by a 25-hp variable speed DC motor. The apparatus is capable of measuring heat transfer while velocity and pressure change over the range of dimensionless parameters normally found in Stirling cycle machines. It allows each parameter to be varied independently and easily. Instrumentation for the apparatus is adequate for measurement of pressure, time, gas and wall temperature, wall heat flux, and gas velocity. It yields preliminary data which show that the apparatus and data acquisition are operating satisfactorily and produce reasonable results.

Smith, Joseph L., Jr.↗

Emitted vibration measurement device and method

This invention is directed to a method and apparatus for measuring emitted vibrational forces produced by a reaction wheel assembly due to imbalances, misalignment, bearing defects and the like. The apparatus includes a low mass carriage supported on a large mass base. The carriage is in the form of an octagonal frame having an opening which is adapted for receiving the reaction wheel assembly supported thereon by means of a mounting ring. The carriage is supported on the base by means of air bearings which support the carriage in a generally frictionless manner when supplied with compressed air from a source. A plurality of carriage brackets and a plurality of base blocks provided for physical coupling of the base and carriage. The sensing axes of the load cells are arranged generally parallel to the base and connected between the base and carriage such that all of the vibrational forces emitted by the reaction wheel assembly are effectively transmitted through the sensing axes of the load cells. In this manner, a highly reliable and accurate measurment of the vibrational forces of the reaction wheel assembly can be had. The output signals from the load cells are subjected to a dynamical analyzer which analyzes and identifies the rotor and spin bearing components which are causing the vibrational forces.

Gisler, G. L.↗

Apparatuses and methods for gas flux measurements

Embodiments of the disclosure are drawn to apparatus and methods for determining gas flux measurements. A gas plume may be emitted from a source and may be blown by wind in an environment. A measurement system, such as a light detection and ranging (lidar) system may collect a plurality of gas concentration measurements associated with the gas plume at a plurality of locations in the environment. A gas flux may be determined based on one or more of the gas concentration measurements along with a wind speed at a location associated with the gas plume. In some embodiments, a height of the gas plume may be determined, and the wind speed at the height of the gas plume may be determined and used to determine the gas flux.