Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEDICAL ELECTRONICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Illumination of serotonin transporter mechanism and role of the allosteric site

The serotonin transporter (SERT) terminates serotonin signaling by using sodium and chloride gradients to drive reuptake of serotonin into presynaptic neurons and is the target of widely used medications to treat neuropsychiatric disorders. Despite decades of study, the molecular mechanism of serotonin transport, the coupling to ion gradients, and the role of the allosteric site have remained elusive. Here, we present cryo–electron microscopy structures of SERT in serotonin-bound and serotonin-free states, in the presence of sodium or potassium, resolving all fundamental states of the transport cycle. From the SERT-serotonin complex, we localize the substrate-bound allosteric site, formed by an aromatic pocket positioned in the scaffold domain in the extracellular vestibule, connected to the central site via a short tunnel. Together with elucidation of multiple apo state conformations, we provide previously unseen structural understanding of allosteric modulation, demonstrating how SERT binds serotonin from synaptic volumes and promotes unbinding into the presynaptic neurons.

59 BASIC BIOLOGICAL SCIENCES↗

µRWELL-PICOSEC: The Development of Fast Timing Resistive Micro-WELL Detector Technology.

We present the development of a new concept of fast timing gaseous detector, the ?RWELL-PICOSEC detector based on Resistive Micro-Well (?RWELL) technology to provide timing resolution in the tens of picosecond range for application as time-of-flight (TOF) technology in the particle physics and medical instrumentation fields. The ?RWELL-PICOSEC technology combined a Cerenkov radiator for the generation of Cerenkov photons from high energy charged particles, a photocathode for the conversion of the produced photons into primary electrons and the ?RWELL foil for the multiplication of the electron to produce large signal on pad segmentation readout. The proof of concept of ?RWELL-PICOSEC is demonstrated with a small single-channel prototype and preliminary timing performance of 90 ps has been measured. Optimization study the amplification structure of ?RWELL-PICOSEC for the improvement of timing resolution is discussed and results on timing performance studies in beam at CERN are presented. The development of large area (100 mm × 100 mm) ?RWELL-PICOSEC and associated multichannel fast readout electronics and data acquisition system are also reported

Weisenberger, Andrew↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

X-Ray Detector for 1 to 30 keV

Array of silicon X-ray detecting diodes measures photon energy and provides image of X-ray pattern. Regardless of thickness of new X-ray detector, depletion region extends through it. Impinging X-rays generate electrons in quantities proportional to X-ray energy. X-ray detector is mated to chargecoupled-device array for image generation and processing. Useful in industrial part inspection, pulsed-plasma research and medical application.

Alcorn, G.↗

The Human Phenotype Ontology in 2024: phenotypes around the world

The Human Phenotype Ontology (HPO) is a widely used resource that comprehensively organizes and defines the phenotypic features of human disease, enabling computational inference and supporting genomic and phenotypic analyses through semantic similarity and machine learning algorithms. The HPO has widespread applications in clinical diagnostics and translational research, including genomic diagnostics, gene-disease discovery, and cohort analytics. In recent years, groups around the world have developed translations of the HPO from English to other languages, and the HPO browser has been internationalized, allowing users to view HPO term labels and in many cases synonyms and definitions in ten languages in addition to English. Since our last report, a total of 2239 new HPO terms and 49235 new HPO annotations were developed, many in collaboration with external groups in the fields of psychiatry, arthrogryposis, immunology and cardiology. The Medical Action Ontology (MAxO) is a new effort to model treatments and other measures taken for clinical management. Finally, the HPO consortium is contributing to efforts to integrate the HPO and the GA4GH Phenopacket Schema into electronic health records (EHRs) with the goal of more standardized and computable integration of rare disease data in EHRs.

59 BASIC BIOLOGICAL SCIENCES↗

Earth benefits from space life sciences

Contributions of space exploration which are widely recognized are those dealing with the impact of space technology on public health and medical services in both urban and remote rural areas. Telecommunications, image enhancement, 3-dimensional image reconstructions, miniaturization, automation, and data analysis, have transformed the delivery of medical care and have brought about a new impetus to the field of biomedicine. Many areas of medical care and biological research have been affected. These include technological breakthroughs in such areas as: (1) diagnosis, treatment, and prevention of cardiovascular diseases, (2) new approaches to the understanding of osteoporosis, (3) early detection of genetic birth defects, (4) emergency medical care, and (5) treatment of chronic metabolic disorders. These are but a few examples where technology originally developed to support space medicine or space research has been applied to solving medical and health care delivery problems on Earth.

NASA Center HQS↗

Electronics Demonstrated for Low- Temperature Operation

The operation of electronic systems at cryogenic temperatures is anticipated for many NASA spacecraft, such as planetary explorers and deep space probes. For example, an unheated interplanetary probe launched to explore the rings of Saturn would experience an average temperature near Saturn of about 183 C. Electronics capable of low-temperature operation in the harsh deep space environment also would help improve circuit performance, increase system efficiency, and reduce payload development and launch costs. An ongoing research and development program on low-temperature electronics at the NASA Glenn Research Center at Lewis Field is focusing on the design of efficient power systems that can survive and exploit the advantages of low-temperature environments. The targeted systems, which are mission driven, include converters, inverters, controls, digital circuits, and special-purpose circuits. Initial development efforts successfully demonstrated the low-temperature operation and cold-restart of several direct-current/direct-current (dc/dc) converters based on different types of circuit design, some with superconducting inductors. The table lists some of these dc/dc converters with their properties, and the photograph shows a high-voltage, high-power dc/dc converter designed for an ion propulsion system for low-temperature operation. The development efforts of advanced electronic systems and the supporting technologies for low-temperature operation are being carried out in-house and through collaboration with other Government agencies, industry, and academia. The Low Temperature Electronics Program supports missions and development programs at NASA s Jet Propulsion Laboratory and Goddard Space Flight Center. The developed technologies will be transferred to commercial end users for applications such as satellite infrared sensors and medical diagnostic equipment.

Patterson, Richard L.↗

NASA Tech Briefs, March 2006

Topics covered include: Medical Signal-Conditioning and Data-Interface System; Instruments for Reading Direct-Marked Data-Matrix Symbols; Processing EOS MLS Level-2 Data; Ground Processing of Data From the Mars Exploration Rovers; Estimating Total Electron Content Using 1,000+ GPS Receivers; NASA Solar Array Demonstrates Commercial Potential; Improved Control of Charging Voltage for Li-Ion Battery; Programmable Pulse-Position-Modulation Encoder; Wavelength-Agile External-Cavity Diode Laser for DWDM; Pattern-Recognition Processor Using Holographic Photopolymer; Submicrosecond Power-Switching Test Circuit; Three-Function Logic Gate Controlled by Analog Voltage; Integrated System for Autonomous Science; Montage Version 3.0; Utilizing AI in Temporal, Spatial, and Resource Scheduling; Satellite Image Mosaic Engine; Architecture for Control of the K9 Rover; HFGMC Enhancement of MAC/GMC; Automated Activation and Deactivation of a System Under Test; Cleaning Carbon Nanotubes by Use of Mild Oxygen Plasmas; Generating Aromatics From CO2 on Mars or Natural Gas on Earth; Attaching Thermocouples by Peening or Crimping; Heat Treatment of Friction-Stir-Welded 7050 Aluminum Plates; Generating Breathable Air Through Dissociation of N2O; High-Performance Scanning Acousto-Ultrasonic System; Correction for Thermal EMFs in Thermocouple Feedthroughs; Using Quasiparticle Poisoning To Detect Photons; Estimating Resolution Lengths of Hybrid Turbulence Models; Education and Training Module in Alertness Management; Cargo-Positioning System for Next-Generation Spacecraft; Micro-Imagers for Spaceborne Cell-Growth Experiments; Holographic Solar Photon Thrusters; Plasma-Based Detector of Outer-Space Dust Particles; and Generation of Data-Rate Profiles of Ka-Band Deep-Space Links.

Source record↗

Cadmium Magnesium Telluride for Next Generation X-Ray Free Electron Laser, Synchrotron and Many Other Applications

We developed a picosecond photodetector based on our Bridgman grown and specially engineered Cadmium Magnesium Telluride (Cd 1-x Mg x Te) single crystal that is sensitive to both optical and x-ray pulses for coarse timing in Free Electron Laser applications. Cd 1-x Mg x Te is a wide bandgap semiconductor material with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma ray radiation, thermal neutrons, and medical imaging. However, for femtosecond optical and x-ray cross correlation, the material has to have very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have very low bulk leakage current, in the 0.10 pA range. Hence the ability to tailor or engineer the material is very crucial. In this paper, picosecond response and the crystal growth of this specially engineered cadmium magnesium telluride material will be presented. Other material characterization and transient measurements will also be discussed along with room temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

The United States Department of Energy and National Institutes of Health Collaboration: Medical Care Advances via Discovery in Physical Sciences

Over several months, representatives from the U.S. Department of Energy (DOE) Office of Science and National Institutes of Health (NIH) had a number of meetings that lead to the conclusion that innovations in the Nation's health care could be realized by more directed interactions between NIH and DOE. It became clear that the expertise amassed and instrumentation advances developed at the DOE physical science laboratories to enable cutting-edge research in particle physics could also feed innovation in medical healthcare. To meet their scientific mission, the DOE laboratories created advances in such technologies as particle beam generation, radioisotope production, high-energy particle detection and imaging, superconducting particle accelerators, superconducting magnets, cryogenics, high-speed electronics, artificial intelligence, and big data. To move forward, NIH and DOE initiated the process of convening a joint work- shop which occurred on July 12th and 13th, 2021. Here, this Special Report presents a summary of the findings of the collaborative workshop and introduces the goals of the next one.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Photoelectron spectroscopy and computational investigations of the electronic structures and noncovalent interactions of cyclodextrin-closo-dodecaborate anion complexes x-CD·B12X122- (x = a, ß, y; X = H, F)

We report a joint negative ion photoelectron spectroscopy (NIPES) and computational study on the electronic structures and noncovalent interactions of a series of cyclodextrin-closo-dodecaborate dianion complexes, ?-CD·B12X122- (? = a, ß, ?; X = H, F). The measured vertical / adiabatic detachment energies (VDEs / ADEs) are 1.15/0.93, 3.55/3.20, 3.90/3.60, and 3.85/3.60 eV for B12H122- and its a-, ß-, ?-CD complexes, respectively; while the corresponding values are 1.90/1.70, 4.00/3.60, 4.33/3.95, and 4.30/3.85 eV for the X = F case. These results show that the inclusion of B12X122- into the CD cavities greatly increase the electronic stability of the dianions. The effect of electronic stabilization for ß-CD is roughly the same as for ?-CD, both being considerably stronger than that for a-CD. Density functional theory (DFT) based geometry optimization reveals that B12X122- are inserted into CDs increasingly deeper from a-CD to ?-CD. The calculated VDEs and ADEs agree with the experiments well, particularly, reproducing the electron binding energy (EBE) trends. The molecular orbital analyses indicate that the most loosely bound photodetached electrons origin from the guest B12X122- moieties. In addition to a shift of all signals to larger EBE, significant changes in the signal patterns are observed. At low EBE, this is due to the splitting of highly degenerate B12X122- orbitals, while at high EBE, photodetachment from CD oxygens contributes to the new bands. The guest B12X122- and host CD nocovalent, size-specific interaction based on the independent gradient model (IGM) and energy decomposition analysis (EDA), is dominated by electrostatic interactions. The analysis further unravels unambiguiously the existence of dihydrogen bonding and how it affects the total energy that stabilizes the host-guest complexes of CDs·B12H122- compared to the general hydrogen bonding interaction in CDs·B12F122-. This work clearly exhibits strong influences on the electronic structures of dodecaborates upon clustering with CDs, with both size (a-, ß-, ?-) and molecular (X = H or F) specificities, thus providing critical molecular-level information on the cyclodextrin-closo-dodecaborate interactions of interest to medical applications, e.g. Boron neutron capature therapy. The NIPES experiments done at PNNL were supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences and Bioscience (X.-B.W.) and was performed at the EMSL, a national scientific user facility sponsored by DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory. H.S. and Z.S. acknowledge the funding support of National Natural Science Foundation of China (Nos.11727810, 61720106009 and 21603074), the Science and Technology Commission of Shanghai Municipality (Nos. 19JC1412200), and the Program of Introducing Talents of Discipline to Universities 111 project (B12024). Z. L. thanks the China Scholarship Council (CSC) for financial support. We acknowledge the ECNU Multifunctional Platform for Innovation (001) and HPC Research Computing Team for providing computational and storage resources. J.W. acknowledges support from the Alexander von Humboldt foundation (Feodor Lynen Fellowship and Rückkehrerstipendium), a Freigeist fellowship of the Volkswagenfoundation and Prof. Vladimir A. Azov for helpful discussions.

Li, Zhipeng↗

Evaluation of Niowave's Proposed Solvent Washing Approach

Niowave, Inc., is a domestic supplier of medical and industrial isotopes from uranium (U) and radium (Ra). The company has recently entered into a cooperative agreement with the U.S. Department of Energy’s National Nuclear Security Administration (NNSA) and plans to deploy a superconducting electron accelerator (LINAC) to fission U for molybdenum-99 ( 99 Mo) production without the need for a nuclear reactor or highly enriched uranium (HEU). NNSA provided funding to the Savannah River National Laboratory (SRNL) to support Niowave in this effort. SRNL evaluated the application of the solvent washing process for Niowave.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Low Temperature Characterization of Ceramic and Film Power Capacitors

Among the key requirements for advanced electronic systems is the ability to withstand harsh environments while maintaining reliable and efficient operation. Exposures to low temperature as well as high temperature constitute such stresses. Applications where low temperatures are encountered include deep space missions, medical imaging equipment, and cryogenic instrumentation. Efforts were taken to design and develop power capacitors capable of wide temperature operation. In this work, ceramic and film power capacitors were developed and characterized as a function of temperature from 20 C to -185 C in terms of their dielectric properties. These properties included capacitance stability and dielectric loss in the frequency range of 50 Hz to 100 kHz. DC leakage current measurements were also performed on the capacitors. The manuscript presents the results that indicate good operational characteristic behavior and stability of the components tested at low temperatures.

Hammoud, Ahmad↗

Neutron Source Facility of the National Science Center “Kharkiv Institute of Physics and Technology” at Kharkiv, Ukraine

Argonne National Laboratory developed, designed, and supported the construction of a state-of-the-art Neutron Source Facility (NSF) at the Kharkov Institute of Physics and Technology (KIPT) in Kharkov Ukraine, under the U.S. DOE NNSA Russian Research Reactor Fuel Return (RRRFR) program. Ukraine approved the return of all highly enriched uranium in the country to Russia prior to the 2012 Nuclear Security Summit in return for the RRRFR program to fund the development, the design, and the construction of the NSF. The facility is designed to produce medical isotopes, train nuclear professionals, support the Ukrainian nuclear industry, and provide experimental capabilities for performing reactor physics, materials, and basic science research. The NSF was successfully started and operated in August 2021. The NSF is the first facility of this type in the world, and it will be used to understand the physics of driven systems for energy production and the disposal of spent nuclear fuels. The NSF consists of a subcritical assembly using low enriched uranium (LEU) fuel driven with an electron accelerator. The NSF target design utilizes tungsten or natural uranium for producing neutrons through photonuclear reactions using 100-MeV electrons. The accelerator power is 100 KW, which produces 3x10 14 neutrons per second from the uranium target. The subcritical assembly is designed to obtain the highest possible neutron flux intensity with an effective neutron multiplication factor of less than 0.98. Passive safety, reliability, and environmental considerations were included in the NSF design. The NSF utilization study shows that this neutron source has the capability of producing different medical isotopes. Several horizontal neutron channels are incorporated for performing applied and basic research. The NSF is configured to accommodate future design upgrades and new missions. The facility design was approved by the Ukraine Academy of Sciences before starting the NSF construction. The construction, the equipment installation, and the operation of the different systems of the NSF were completed and approved by the Ukrainian regulators. In July 2020, the State Nuclear Regulatory Inspectorate of Ukraine (SNRIU) issued a license for the physical startup of the NSF. The construction of facility was completed in early 2021.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fiber-Coupled Acousto-Optical-Filter Spectrometer

Fiber-coupled acousto-optical-filter spectrometer steps rapidly through commanded sequence of wavelengths. Sample cell located remotely from monochromator and associated electronic circuitry, connected to them with optical fibers. Optical-fiber coupling makes possible to monitor samples in remote, hazardous, or confined locations. Advantages include compactness, speed, and no moving parts. Potential applications include control of chemical processes, medical diagnoses, spectral imaging, and sampling of atmospheres.

Levin, Kenneth H.↗

Elastomeric Sensing of Pressure with Liquid Metal and Wireless Inductive Coupling

This project describes resistance-based soft sensors filled with liquid metal, which permit measurements of large strains (0 percent to 110 percent), associated with small forces of less than 30 Newtons. This work also demonstrates a methodology for wireless transfer of these strain measurements without connected electrodes. These sensors allow intermittent detection of pressure on soft membranes with low force. Adapting these sensors for passive wireless pressure sensing will eliminate the need for embedded batteries, and will allow the sensors to transmit pressure data through non-conductive materials including glass and acrylic. The absence of batteries allows us to embed these sensors into materials for long-term use because the sensors only use passive analog circuit elements. We found the oxidation of the liquid metal (eutectic gallium indium) plays a role in the repeatability of the soft sensors. We investigated how the oxidation layer affected the behavior of the sensor by encapsulating materials (silicone, fluorosilicone, and PVC) with varied permeabilities to oxygen. We measured the effects of mechanical loading on the oxidation layer and the effects of wireless inductive coupling on the oxidation layer. We concluded our research by investigating the effects of embedding self-resonant circuits into polydimethylsiloxane (PDMS). Efforts to design engineered systems with soft materials are a growing field with progress in soft robotics, epidermal electronics, and wearable electronics. In the field of soft robotics, PDMS-based grippers are capable of picking up delicate objects because their form-fitting properties allow them to conform to the shape of objects more easily than conventional robotic grippers. Epidermal devices also use PDMS as a substrate to hold electronic components such as radios, sensors, and power supply circuits. Additionally, PDMS-based soft sensors can monitor human motion with liquid metal embedded within micro-channels. Passive wireless sensors have applications in structural health monitoring and medical health monitoring. Doctors can take wireless blood pressure measurements inside arteries to monitor the progression of heart disease. Glaucoma patients can use this technology to monitor the pressure in their eyes to track the progression of the disease.

Dick, Jacob↗

Enhanced detection of volatile organic compounds (VOCs) by caffeine modified carbon nanotube junctions

Detection of vapor phase analytes and gas molecules is primarily essential for numerous applications including medical diagnostic, environmental monitoring, chemical threat detection, food quality control, and chemical warfare agents. Here, we developed Caffeine functionalized carbon nanotubes (CNTs) random network based vapor quantum resistive sensors (vQRSs) for volatile organic compounds (VOCs) detection. The localized transmission electron microscopy (TEM) image and energy dispersive X-ray spectroscopy (EDS) confirm migration of caffeine to CNT–CNT junction (CNTj). We have recorded more than one order of magnitude higher sensitivity and unique selectivity towards selective VOCs (e.g., acetone, toluene, ethanol, methanol, etc.) with short response time (few seconds) for caffeine modified CNT junction (Caf-CNTj) vQRSs. Molecular dynamics (MD) calculations suggest that the sensitivity of the sensor is diffusion limited, with an advective contribution for ethanol. Furthermore, the designed Caf-CNTj sensors can potentially be important candidate to be a part of electronic nose used for various application such as breath analysis and food quality monitoring.

36 MATERIALS SCIENCE↗