Search NASA⌕ Search

SEARCH · Search NASA

Results for “MOLECULAR BEAM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Topics in atomic hydrogen standard research and applications

Hydrogen maser based frequency and time standards have been in continuous use at NASA tracking stations since February 1970, while laboratory work at Goddard has continued in the further development and improvement of hydrogen masers. Concurrently, experimental work has been in progress with a new frequency standard based upon the hydrogen atom using the molecular beam magnetic resonance method. Much of the hydrogen maser technology is directly applicable to the new hydrogen beam standard, and calculations based upon realistic data indicate that the accuracy potential of the hydrogen atomic beam exceeds that of either the cesium beam tube or the hydrogen maser, possibly by several orders of magnitude. In addition, with successful development, the hydrogen beam standard will have several other performance advantages over other devices, particularly exceptional stability and long continuous operating life. Experimental work with a new laboratory hydrogen beam device has recently resulted in the first resonance transition curves, measurements of relative state populations, beam intensities, etc. The most important aspects of both the hydrogen maser and the hydrogen beam work are covered.

Peters, H. E.↗

Lunar mass spectrometer test program

The procedures used and the results are described, which were obtained in a test program to demonstrate the performance of a candidate lunar mass spectrometer. The instrument was designed to sample and measure gases believed to exist in the lunar atmosphere at the surface. The instrument consists of a cold cathode ion source, a small quadrupole mass analyzer, and an off-axis electron multiplier ion-counting detector. Instrument resolution, sensitivity, and S/N ratio were demonstrated over the mass range 0-150 amu and over a partial pressure range from ntorr to ptorr. The subject analyzer was also prepared for extended testing, in conjunction with two other candidate instruments, in a large molecular beam vacuum facility.

Torney, F. L.↗

On the determination of thermospheric atomic-oxygen densities with rocket-borne mass spectrometers.

The experimental investigation of the atomic oxygen response of an open-source mass spectrometer conducted in a high-velocity molecular-beam facility is described, and its results are evaluated. These preliminary results illustrate the value of studies of this type and tentatively support the thesis that in rocket flights of open-source mass spectrometers atomic oxygen loss is not a serious problem.

Neir, A. O.↗

Thermospheric temperature measurement technique.

A method for measurement of temperature in the earth's lower thermosphere from a high-velocity probes is described. An undisturbed atmospheric sample is admitted to the instrument by means of a free molecular flow inlet system of skimmers which avoids surface collisions of the molecules prior to detection. Measurement of the time-of-flight distribution of an initially well-localized group of nitrogen metastable molecular states produced in an open, crossed electron-molecular beam source, yields information on the atmospheric temperature. It is shown that for high vehicle velocities, the time-of-flight distribution of the metastable flux is a sensitive indicator of atmospheric temperature. The temperature measurement precision should be greater than 94% at the 99% confidence level over the range of altitudes from 120-170 km. These precision and altitude range estimates are based on the statistical consideration of the counting rates achieved with a multichannel analyzer using realistic values for system parameters.

Hueser, J. E.↗

Infrared spectra of group III A metal oxides

The measurement of infrared frequencies of metal-oxygen species which could be formed in the matrix and to investigate with an oxygen-18 enrichment study the controversy on the vibrational assignments for the suboxide. Several new molecules, Al3O2, Ga3O, In3O, In4O2, IntaO, IntaO2, and In2WO4, were found by mass spectrometric sampling to exist in extremely minor concentrations in the vapor phase. The latter three species were formed by reaction with the crucible materials and were unimportant for an infrared analysis. The infrared spectroscopic measurements were obtained by the matrix isolation technique of molecular beam sampling. The MO2 species were formed by direct reaction between metal and O2 in the matrix. A C2v structure and an O-M-O bond angle near 40 deg was favored for these molecules by analogy with a similar investigation of the alkali metals. The vibrational frequencies which were determined are given.

Lynch, D. A., Jr.↗

Absolute calibration of Apollo lunar orbital mass spectrometer.

Recent experiments were conducted in Langley Research Center's molecular beam system to perform an absolute calibration of the lunar orbital mass spectrometer which was flown on the Apollo 15 and 16 missions. Tests were performed with several models of the instrument using two test gases, argon and neon, in the 1 ntorr to .1 picotorr range. Sensitivity to argon at spacecraft orbital velocity was .00028 A/torr enabling partial pressures in the .01-picotorr range to be measured at the spacecraft altitude. Neon sensitivity was nearly a factor of 5 less. Test data support the feasibility of using the lunar orbital mass spectrometer as a tool to gather information about the lunar atmosphere.

Yeager, P. R.↗

Condensation in CO2 free jet expansions. II - Growth of small clusters.

An investigation into the kinetics of molecular clustering processes which occur in the highly supersaturated vapor of a CO2 free jet is described. Terminal cluster concentrations in expansions from room temperature and reservoir pressures in the range from 400 to 900 torr were determined for trimeric CO2 for nozzle diameters of .0076 cm, .015 cm, and .023 cm and in the case of CO2 tetramer and pentamer for .015 cm nozzle diameter. The measurements were made mass spectrometrically in a supersonic molecular beam apparatus. A kinetic analysis was developed from an extension of the critical nucleus concept of nucleation theory and rate equations based on intermolecular collisions. The observed cluster populations could be accounted for by the theory by adopting sticking probabilities of approximately .03 for monomer impinging on dimer, trimer, and tetramer.

Dorfeld, W. G.↗

Time-of-flight measurements of metastable state lifetimes.

A time-of-flight method for measurement of the lifetime of metastable molecules is described. The method is applicable to a molecular beam that has molecules in several different metastable excited states. As compared to methods used previously, the method has the advantages that it does not require selective excitation or quenching of the different states; moreover, it does not require a determination of the relative populations or velocity distributions of molecules in the excited states.

Kaslow, D. E.↗

High-temperature mass spectrometry - Vaporization of group 4-B metal carbides

The high temperature vaporization of the metal-carbon systems TiC, ZrC, HfC, and ThC was studied by the Knudsen effusion - mass spectrometric method. For each system the metal dicarbide and tetracarbide molecular species were identified in the gas phase. Relative ion currents of the carbides and metals were measured as a function of temperature. Second- and third-law methods were used to determine enthalpies. Maximum values were established for the dissociation energies of the metal monocarbide molecules TiC, ZrC, HfC, and ThC. Thermodynamic functions used in the calculations are discussed in terms of assumed molecular structures and electronic contributions to the partition functions. The trends shown by the dissociation energies of the carbides of Group 4B are compared with those of neighboring groups and discussed in relation to the corresponding oxides and chemical bonding. The high temperature molecular beam inlet system and double focusing mass spectrometer are described.

Stearns, C. A.↗

Photolysis of spacecraft contaminants

A molecular beam facility, which was designed to measure photochemical cross-sections, has been constructed at the Athens College science facility. The integration of this vacuum system into an operational photochemical instrument was performed with signal processing consisting of both dc and ac techniques. Of the experiments performed to date on the vacuum ultraviolet photolysis of water vapor, it is apparent that a larger pumping capacity (preferably with differential pumping) is required to improve upon the background signal. Both phase-sensitive detection and ion-counting techniques are recommended for future studies.

Workman, G. L.↗

Laboratory simulation of graphite formation in stellar envelopes

A technique has been developed which permits laboratory simulation of graphite condensation in the envelopes of cool, late sequence stars. Processes in the stellar envelope were simulated by allowing hydrogen-carbon mixtures of typical circumstellar composition and temperature to expand freely into vacuum, cooling and supersaturating the vapor. Expansion products were determined mass spectrometrically through the use of molecular beam techniques. The results of laboratory expansions were scaled to those occurring near M and N stars by comparing the number of collisional events in each case. Kinetic considerations indicate that the important rate process in rarefied envelopes will be C2 formation; consequently scaling by termolecular collisions was employed. Results of this study imply that envelope expansions near M giants contribute at most .01 of the observed interstellar grain density. In the case of pulsating N stars, on the other hand, the results are not inconsistent with previous predictions of essentially complete carbon condensation.

Dorfeld, W. G.↗

High speed hydrogen/graphite interaction

Various aspects of a research program on high speed hydrogen/graphite interaction are presented. Major areas discussed are: (1) theoretical predictions of hydrogen/graphite erosion rates; (2) high temperature, nonequilibrium hydrogen flow in a nozzle; and (3) molecular beam studies of hydrogen/graphite erosion.

Kelly, A. J.↗