Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ground-Support Algorithms for Simulation, Processing, and Calibration of Barnes Static Earth Sensor Measurements: Applications to Tropical Rainfall Measuring Mission Observatory

New algorithms are described covering the simulation, processing, and calibration of penetration angles of the Barnes static Earth sensor assembly (SESA) as implemented in the Goddard Space Flight Center Flight Dynamics Division ground support system for the Tropical Rainfall Measuring Mission (TRMM) Observatory. The new treatment involves a detailed analysis of the measurements by individual quadrants. It is shown that, to a good approximation, individual quadrant misalignments can be treated simply as penetration angle biases. Simple formulas suitable for real-time applications are introduced for computing quadrant-dependent effects. The simulator generates penetration angles by solving a quadratic equation with coefficients uniquely determined by the spacecraft's position and the quadrant's orientation in GeoCentric Inertial (GCI) coordinates. Measurement processing for attitude determination is based on linearized equations obtained by expanding the coefficients of the aforementioned quadratic equation as a Taylor series in both the Earth oblateness coefficient (alpha approx. 1/150) and the angle between the pointing axis and the geodetic nadir vector. A simple formula relating a measured value of the penetration angle to the deviation of the Earth-pointed axis from the geodetic nadir vector is derived. It is shown that even near the very edge of the quadrant's Field Of View (FOV), attitude errors resulting from quadratic effects are a few hundredths of a degree, which is small compared to the attitude determination accuracy requirement (0.18 degree, 3 sigma) of TRMM. Calibration of SESA measurements is complicated by a first-order filtering used in the TRMM onboard algorithm to compute penetration angles from raw voltages. A simple calibration scheme is introduced where these complications are avoided by treating penetration angles as the primary raw measurements, which are adjusted using biases and scale factors. In addition to three misalignment parameters, the calibration state vector contains only two average penetration angle biases (one per each pair of opposite quadrants) since, because of the very narrow sensor FOV (+/- 2.6 degrees), differences between biases of the penetration angles measured by opposite quadrants cannot be distinguished from roll and pitch sensor misalignments. After calibration, the estimated misalignments and average penetration angle biases are converted to the four penetration angle biases and to the yaw misalignment angle. The resultant biases and the estimated scale factors are finally used to update the coefficients necessary for onboard computations of penetration angles from measured voltages.

Natanson, G. A.↗

Measurement of Sauter Mean Diameter (SMD) in Diesel Sprays Using a Scattering-Absorption Measurement Ratio (SAMR) Technique

A new diagnostic for the quantification of Sauter Mean Diameter (SMD) in high-pressure fuel sprays has been recently developed using combined optical and x-ray measurements at the Georgia Institute of Technology and Argonne National Laboratory, respectively. This diagnostic utilizes liquid scattering extinction measurements from diffuse back-illumination imaging, conducted at Georgia Tech, and liquid absorption measurements from x-ray radiography, conducted at Argonne’s Advanced Photon Source. The new diagnostic, entitled the Scattering Absorption Measurement Ratio (SAMR), quantifies two-dimensional distributions of path integrated SMD, enabling construction of the spatial history of drop size development within practical fuel sprays. This technique offers unique benefits over conventional drop-sizing methods in that it can be more robust in optically dense regions of the spray, while also providing high spatial and temporal resolution of the corresponding droplet field. The methodology for quantification of SMD distributions using the SAMR technique has been previously introduced and demonstrated in diesel sprays using the Engine Combustion Network Spray D injector, however a more detailed treatment of measurement uncertainties has been needed. In the current work, we present a summary of the various sources of measurement uncertainty in the SAMR diagnostic, like those due to the experimental setup, data processing methods, and theoretical assumptions, and assess how these sources of uncertainty affect the quantified SMD. The spatially-resolved SMD measurements that result from the SAMR diagnostic will be especially valuable to the engine modeling community for the quantitative validation of spray submodels in engine CFD codes. Careful evaluation and quantification of measurement uncertainties is important to support accurate model validation and to ensure the development of more predictive spray models.

33 ADVANCED PROPULSION SYSTEMS↗

A Method to Estimate Uncertainty in Radiometric Measurement Using the Guide to the Expression of Uncertainty in Measurement (GUM) Method; NREL (National Renewable Energy Laboratory)

Radiometric data with known and traceable uncertainty is essential for climate change studies to better understand cloud radiation interactions and the earth radiation budget. Further, adopting a known and traceable method of estimating uncertainty with respect to SI ensures that the uncertainty quoted for radiometric measurements can be compared based on documented methods of derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM). derivation.Therefore, statements about the overall measurement uncertainty can only be made on an individual basis, taking all relevant factors into account. This poster provides guidelines and recommended procedures for estimating the uncertainty in calibrations and measurements from radiometers. The approach follows the Guide to the Expression of Uncertainty in Measurement (GUM).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simultaneous measurement of tritium and radiocarbon by ultra-low-background proportional counting

Use of ultra-low-background capabilities at Pacific Northwest National Laboratory provide enhanced sensitivity for measurement of low-activity sources of tritium and radiocarbon using proportional counters. Tritium levels are nearly back to pre-nuclear test backgrounds (~2-8 TU in rainwater), which can complicate their dual measurement with radiocarbon due to overlap in the isotope’s respective energy spectra. This activity makes direct dual-isotope measurements challenging without additional chemistry to concentrate the tritium in a sample. We present results of single-isotope proportional counter measurements used to analyze a dual-isotope methane sample synthesized from ~120 mg of H2O and present sensitivity results.

07 ISOTOPE AND RADIATION SOURCES↗

Top-Quark Mass Measurement Using Events with Missing Transverse Energy and Jets at CDF

We present a measurement of the top-quark mass using a sample of tt events in 5.7 fb{sup -1} of integrated luminosity from pp collisions at the Fermilab Tevatron with {radical}(s)=1.96 TeV and collected by the CDF II Detector. We select events having large missing transverse energy, and four, five, or six jets with at least one jet tagged as coming from a b quark, and reject events with identified charged leptons. This analysis considers events from the semileptonic tt decay channel, including events that contain tau leptons. The measurement is based on a multidimensional template method. We fit the data to signal templates of varying top-quark masses and background templates, and measure a top-quark mass of M{sub top}=172.32{+-}2.4(stat){+-}1.0(syst) GeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of neutral gadolinium oscillator strengths using dual-comb absorption spectroscopy in laser-produced plasmas

The oscillator strengths of 43 transitions of neutral gadolinium from 530 to 535 nm were determined based on high-resolution absorption spectra measured by probing a laser-produced plasma (LPP) using time-resolved dual-comb spectroscopy (DCS). Absorption spectra were measured at various time delays, ranging from 33 to 252 µs after the onset of the plasma formation, over which the temperature and number density varied as the ablation plume evolved. A Boltzmann analysis was used to determine the excitation temperature and column density of Gd in the ablation plume, based on measured absorption from 20 Gd I spectral lines with known oscillator strengths. Oscillator strengths were then determined for additional dipole-allowed Gd I transitions identified in the absorption spectra, 19 of which were previously unreported. Oscillator strengths of all measured transitions were compared with literature values when available and show good agreement in most cases. Time-resolved measurement of atomic absorption in the cooling plasma provides access to a range of excitation temperatures and optical densities for the atoms in the ablation plume, allowing repeated measurements under different conditions, thereby improving confidence in the results. The high spectral bandwidth and resolution capabilities of DCS make it well-suited to measuring the dense optical spectrum of Gd, and the technique is applicable to other elements, especially lanthanides and actinides.

(280.4788) Optical Sensing, (280.5395) Plasma Diag↗

Enhanced Dual Confocal Measurement System

A measurement instrument utilizing dual, chromatic, confocal, distance sensors has been jointly developed by General Atomics (GA) and Sandia National Laboratories (SNL) for thickness and flatness measurement of target components used in dynamic materials properties (DMP) experiments on the SNL Z-Machine (Z). Compared to previous methods used in production of these types of targets, the tool saves time and yields a 4x reduction in thickness uncertainty which is one of the largest sources of error in equation of state (EOS) measurements critical to supporting the NNSA’s Stockpile Stewardship program and computer modeling of high energy density experiments. It has numerous differences from earlier instruments operating on the dual confocal sensor principle to accommodate DMP components including larger lateral travel, longer working distance, ability to measure flatness in addition to thickness, built-in thickness calibration standards for quickly checking calibration before and after each measurement, and streamlined operation. Thickness and flatness of 0.2mm-3.3mm thick sections of diamond machined copper and aluminum can be measured to “sub-micron” accuracy. Sections up to 6mm thick can be measured with as-yet undermined accuracy. Furthermore, samples must have one surface which is flat to within 300µm, lateral dimensions of no more than 50mm x 50mm, and height less than 40mm.

36 MATERIALS SCIENCE↗

Activity measurement of Fe 60 through the decay of Co 60 m and confirmation of its half-life

The half-life of the neutron-rich nuclide, 60Fe has been in dispute in recent years. A measurement in 2009 published a value of (2.62 ± 0.04) × 106 years, almost twice that of the previously accepted value from 1984 of (1.49 ± 0.27) × 106 years. This longer half-life was confirmed in 2015 by a second measurement, resulting in a value of (2.50 ± 0.12) × 106 years. All three half-life measurements used the grow-in of the γ-ray lines in 60Ni from the decay of the ground state of 60Co (t1/2=5.27 years) to determine the activity of a sample with a known number of 60Fe atoms. In contrast, the work presented here measured the 60Fe activity directly via the 58.6 keV γ-ray line from the short-lived isomeric state of 60Co (t1/2=10.5 minutes), thus being independent of any possible contamination from long-lived 60gCo. A fraction of the material from the 2015 experiment with a known number of 60Fe atoms was used for the activity measurement, resulting in a half-life value of (2.72 ± 0.16) × 106 years, confirming again the longer half-life. In addition, 60Fe/56Fe isotopic ratios of samples with two different dilutions of this material were measured with Accelerator Mass Spectrometry (AMS) to determine the number of 60Fe atoms. Combining this with our activity measurement resulted in a half-life value of (2.69 ± 0.28) × 106 years, again agreeing with the longer half-life.

Ostdiek, Karen M.↗

Measurement of the Target-Normal Single-Spin Asymmetry in Deep-Inelastic Scattering from the Reaction He 3 ↑ ( e , e ' ) X

We report here the first measurement of the target-normal single-spin asymmetry in deep-inelastic scattering from the inclusive reaction He 3 ↑ ( e , e ' ) X on a polarized He 3 gas target. Assuming time-reversal invariance, this asymmetry is strictly zero in the Born approximation but can be nonzero if two-photon-exchange contributions are included. The experiment, conducted at Jefferson Lab using a 5.89 GeV electron beam, covers a range of 1.7 < W < 2.9 GeV , 1.0 < Q 2 < 4.0 GeV 2 and 0.16 < x < 0.65 . Neutron asymmetries were extracted using the effective nucleon polarization and measured proton-to- He 3 cross-section ratios. The measured neutron asymmetries shown are negative with an average value of ( - 1.09 ± 0.38 ) × 1 0 - 2 for invariant mass W > 2 GeV , which is nonzero at the 2.89 σ level. Our measured asymmetry agrees both in sign and magnitude with a two-photon-exchange model prediction that uses input from the Sivers transverse momentum distribution obtained from semi-inclusive deep-inelastic scattering.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Variance components in confocal scanning laser tomography measurements of neuro‐retinal rim area and the effect of repeated measurements on the power to detect loss over time

Abstract Purpose To estimate the variation in measurements of neuro‐retinal rim area (NRA) determined by confocal scanning laser tomography and consequences for clinical follow‐up. Methods Altogether, 24 healthy subjects were randomized on –320 μ m, Moorfields and Standard NRA plane strategies. Additionally, NRA was measured in 32 glaucoma subjects. Variance components for subjects, visits and measurements were estimated with analysis of variance. Sample sizes required to detect a 6.0 × 10 −2 mm 2 NRA change were estimated assuming a significance level of 0.05 and a power of 0.8. Consequences for independent group, and paired comparison design, respectively, were analysed. Further, precision in estimates within subjects over time was investigated. Results The variation of NRA among subjects was considerably larger than the variation among visits and measurements. For glaucoma subjects, the variation among visits and measurements were of the same order but larger than in healthy subjects. It was found that independent group comparisons require inconveniently large sample sizes. Within‐subject paired comparisons over time require sample sizes of below 15 subjects. The estimated variations for glaucoma subjects imply that 54 months of follow‐up is required for detection of change from baseline. Conclusions The variance for subjects is substantial in relation to those for visits and measurements. Cross‐sectional independent group comparisons of levels of NRA are unsuitable, due to considerable subject variation. Levels of NRA differences within subjects between visits can be estimated with acceptable precision. Neuro‐retinal rim area (NRA) measurement can be used for long‐term follow‐up of glaucoma progression.

Sandberg Melin, Camilla↗

Generation of a Parabolic Trough Collector Efficiency Curve from Separate Measurements of Outdoor Optical Efficiency and Indoor Receiver Heat Loss

The thermal efficiency of a parabolic trough collector is a function of both the fraction of direct normal radiation absorbed by the receiver (the optical efficiency) and the heat lost to the environment when the receiver is at operating temperature. The thermal efficiency can be determined by testing the collector under actual operating conditions or by separately measuring these two components. This paper describes how outdoor measurement of the optical efficiency is combined with laboratory measurements of receiver heat loss to obtain the thermal efficiency curve. This paper describes this approach and also makes the case that there are advantages to plotting collector efficiency versus the difference between the operating temperature and the ambient temperature at which the receiver heat loss was measured divided by radiation to a fractional power (on the order of 1/3 but obtained via data regression) - as opposed to the difference between operating and ambient temperatures divided by the radiation. The results are shown to be robust over wide ranges of ambient temperature, sky temperature, and wind speed.

14 SOLAR ENERGY↗

TH-CD-BRA-05: First Water Calorimetric Dw Measurement and Direct Measurement of Magnetic Field Correction Factors, KQ,B, in a 1.5 T B-Field of An MRI Linac

Purpose: Reference dosimetry in MR-guided radiotherapy is performed in the presence of a B-field. As a consequence the response of ionization chambers changes considerably and depends on parameters not considered in traditional reference dosimetry. Therefore future Codes of Practices need ionization chamber correction factors to correct for both the change in beam quality and the presence of a B-field. The objective was to study the feasibility of water calorimetric absorbed-dose measurements in a 1.5 T B-field of an MRLinac and the direct measurement of kQ,B calibration of ionization chambers. Methods: Calorimetric absorbed dose to water Dw was measured with a new water calorimeter in the bore of an MRLinac (TPR20,10 of 0.702). Two waterproof ionization chambers (PTW 30013, IBA FC-65G) were calibrated inside the calorimeter phantom (ND,w,Q,B). Both measurements were normalized to a monitor ionization chamber. Ionization chamber measurements were corrected for conventional influence parameter. Based on the chambers’ Co-60 calibrations (ND,w,Q0), measured directly against the calorimeter. In this study the correction factors kQ,B was determined as the ratio of the calibration coefficients in the MRLinac and in Co-60. Additionally, kB was determined based on kQ values obtained with the IAEA TRS-398 Code of Practice. Results: The kQ,B factors of the ionization chambers mentioned above were respectively 0.9488(8) and 0.9445(8) with resulting kB factors of 0.961(13) and 0.952(13) with standard uncertainties on the least significant digit(s) between brackets. Conclusion: Calorimetric Dw measurements and calibration of waterproof ionization chambers were successfully carried out in the 1.5 T B-field of an MRLinac with a standard uncertainty of 0.7%. Preliminary kQ,B and kB factors were determined with standard uncertainties of respectively 0.8% and 1.3%. The kQ,B agrees with an alternative method within 0.4%. The feasibility of water calorimetry in the presence of B-fields was demonstrated by the direct determination of Dw and kQ,B. This work was supported by EMRP grant HLT06. The EMRP is jointly funded by the EMRP participating countries within EURAMET and the European Union.

60 APPLIED LIFE SCIENCES↗