Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Intrinsic thermal interfacial resistance measurement in bonded metal–polymer foils

Heat conduction through bonded metal–polymer interfaces often limits the overall heat transfer in electronic packaging, batteries, and heat recovery systems. To design the thermal circuit in such systems, it is essential to measure the thermal interfacial resistance (TIR) across ~1 µm to 100 µm junctions. Previously reported TIR of metal–polymer junctions utilize ASTM E1530-based two-block systems that measure the TIR by applying pressure across the interface through external heating and cooling blocks. Here, we report a novel modification of the ASTM-E1530 technique that employs integrated heaters and sensors to provide an intrinsic TIR measurement of an adhesively bonded metal–polymer junction. We design the measurement technique using finite element simulations to either passively suppress or actively compensate the lateral heat diffusion through the polymer, which can minimize the systematic error to ≲5%. Through proof-of-concept experiments, we report the TIR of metal–polymer interfaces made from DuPont’s Pyralux double-side copper-clad laminates, commonly used in flexible printed circuit boards. Our TIR measurement errors are <10%. We highlight additional sources of errors due to non-idealities in the experiment and discuss possible ways to overcome them. Our measurement technique is also applicable to interfaces that are electrically insulating such as adhesively joined metal–metal junctions and sputter-coated or welded metal–polymer junctions. Altogether, the technique is capable of measuring TIR ≳10 –5 m 2 KW –1 in bonded metal–polymer foils and can be tailored for in situ measurements in flexible electronics, circuit packaging, and other hybrid metal–polymer systems.

47 OTHER INSTRUMENTATION↗

Quadrupole-mediated dielectric response and the charge-asymmetric solvation of ions in water

Treating water as a linearly responding dielectric continuum on molecular length scales allows very simple estimates of the solvation structure and thermodynamics for charged and polar solutes. While this approach can successfully account for basic length and energy scales of ion solvation, computer simulations indicate not only its quantitative inaccuracies but also its inability to capture some basic and important aspects of microscopic polarization response. Here, we consider one such shortcoming, a failure to distinguish the solvation thermodynamics of cations from that of otherwise-identical anions, and we pursue a simple, physically inspired modification of the dielectric continuum model to address it. The adaptation is motivated by analyzing the orientational response of an isolated water molecule whose dipole is rigidly constrained. Its free energy suggests a Hamiltonian for dipole fluctuations that accounts implicitly for the influence of higher-order multipole moments while respecting constraints of molecular geometry. Finally, we propose a field theory with the suggested form, whose nonlinear response breaks the charge symmetry of ion solvation. An approximate variational solution of this theory, with a single adjustable parameter, yields solvation free energies that agree closely with simulation results over a considerable range of solute size and charge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Temperature estimation in a spatially inhomogeneous flame by diode laser absorption spectroscopy

A two-temperature (2T) model is proposed for estimating the temperature of a spatially inhomogeneous hot zone using single-beam diode laser absorption spectrometry. The proposed algorithm is based on fitting experimental absorption spectra by a linear combination of two database-simulated single-temperature spectra with different temperatures. The model efficiency is experimentally demonstrated when determining the temperature in different flame zones of a Wolfgard – Parker slot burner. The proposed 2T algorithm is used to find the maximum and minimum temperatures in different flame sections, which are compared with local temperatures in the same flame zones measured by the method of coherent anti-Stokes Raman scattering (CARS). It is shown that the maximum temperatures determined by the proposed 2T algorithm are in good agreement with CARS data in flame zones where high-temperature regions prevail. A good agreement between the minimum temperatures obtained by these two methods is also observed for predominantly cold zones. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation of femtosecond interferometry when studying the effect of intense laser irradiation of a transparent medium

A method for comparing experimental and simulation results obtained when transmitting a femtosecond laser pulse through a material is proposed. This method is based on computer reproduction of photographs recorded using femtosecond interferometry. A numerical analysis of the spatial and temporal evolution of an intense (∼10{sup 13} W cm{sup −2}) pulse propagating in the bulk of yttrium aluminium garnet is presented. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral features of colloidal solutions of elongated gold nanoparticles produced by laser ablation in aqueous solutions

The extinction spectra of colloidal solutions of gold nanoparticles produced by laser ablation in water and aqueous solutions of salts using two near-IR lasers with pulse durations of 200 ns and 1 ps are experimentally investigated. The extinction spectrum of the particles formed by ablation in aqueous solutions is characterised by enhanced optical density in the red and IR regions. This feature is due to the formation of elongated gold nanoparticles, as confirmed by transmission electron microscopy. The surface images of a gold target subjected to multipulse laser ablation exhibit micron and submicron structures. (nanophotonics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement accuracy and spatial resolution of a distributed temperature sensor based on a two-pulse differential coherent reflectometer

We present a model and numerical simulation of a distributed temperature sensor based on a two-pulse differential coherent optical time-domain reflectometer (COTDR). The differential phase measured using a phase-sensitive Rayleigh reflectometer is shown to have a regular component, which is a linear function of temperature, and a random component, which is related to a random distribution of scattering centres in the fibre and restricts the accuracy of measurements of variations in temperature. Measurement accuracy can be improved by reducing the relative contribution of the random component via a decrease in pulse duration and/or an increase in the time delay between pulses. The spatial resolution of a differential two-pulse phase-sensitive reflectometer is shown to be determined by the time delay between pulses and to vary little with pulse duration. At a typical pulse duration (200 ns) and delay time (300 ns), the accuracy in measurements of variations in temperature in the 0.1-K range is 2 % and the spatial resolution is about 30 m. (fibre-optic sensors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Control of the optical properties of gum and dentin tissue of a human tooth at laser spectral lines in the range of 200 – 800 nm

A change in the optical properties of the tissue of the gums and dentin of a human tooth is experimentally investigated in vitro with the application of a 99.5 % glycerol solution. The kinetics of the total transmittance in the spectral range of 200 – 800 nm on characteristic laser lines is studied. It is shown that the effectiveness of optical clearing, expressed as a relative increase in the total transmittance, for gum tissue in the laser radiation range of 200 – 800 nm can vary significantly (by an order of magnitude). In this case, the absolute values of optical transmittance in the UV region are relatively small due to the strong absorption by the endogenous chromophores of the studied tissues, and in the visible and NIR regions, on the contrary, they are significant, which is due to the absence of strongly absorbing chromophores. The effectiveness of dentin clearing in the entire visible and NIR spectral regions is on average 25 % for 300 minutes of immersion of the sample in a 99.5 % glycerol solution. The presented results are necessary for increasing the efficiency of laser therapy and methods for optical monitoring of morphological changes in biological tissues for the purpose of early diagnosis of diseases. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending the operation range of a phase-sensitive optical time-domain reflectometer by using fibre with chirped Bragg gratings

>A record long external-disturbance detection distance of 140 km without employing optical amplifiers in the fibre line is demonstrated by a phase-sensitive optical time-domain reflectometer (Φ-OTDR) using a fibre section with inscribed chirped fibre Bragg gratings (CFBGs). This solution provides simultaneous operation of Φ-OTDR with a standard single-mode fibre at a distance of up to 100 km and with a CFBG fibre section located from the fibre line input point by at least 140 km. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phase-shift speckle-shearing interferometry

We have numerically simulated the process of measuring stress – strain states by the method of speckle-shearing interferometry using the phase-shift technique. A computer model with the possibility of setting its strain and roughness is developed, which includes a model of a diffusely reflecting test object corresponding to the characteristics of a real membrane, as well as a speckle interferometer model that allows speckle interferograms to be obtained for different speckle sizes and angles between interfering beams. The process of reconstructing the object surface topogram from model speckle interferograms by the phase-shift technique is implemented. Using the developed models, a two-dimensional shearogram are obtained, which is a derivative of the strain field of a circular membrane. Comparison of the results of numerical simulation with experimental data shows that the differences (rms deviations) do not exceed 0.02 μm. It is also shown that the error of interferogram reconstruction by the phase-shift technique increases significantly when the test object strains exceed 12 μm. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic wavefront sensors

A brief historical review of the first designs of holographic wavefront sensors (WFS’s) and the concepts lying in their basis is presented. The main directions in the development of these sensors are highlighted and considered. One of these directions implies a two-stage transition from the use of several separate measuring channels with holograms filtering only one Zernike mode: first to the use of one channel with a multiplexed hologram filtering several first Zernike modes, and then to filtering the entire set of Zernike modes with the aid of one combined multiplexed hologram. Another line of research in this field (related to the first one) is the optimisation of the filter hologram structure in order to reduce cross-modulation interferences, increase multiplexing level, etc. One more line of research implements principles of dynamic holography by introducing spatial light modulators into the WFS composition. Hence, the advantages of time multiplexing of holograms can be used. The approach developed by G. Andersen’s team, aimed at adapting the holographic WFS design for operation as an element of adaptive optical system with a zonal corrector, as well as an approach implying development of hybrid holographic sensors, are considered separately. The results of the authors’ studies of holographic WFS’s with application of the methods of Fourier holography (i.e., holography of focused beams, in particular, using diffuse scatterers in a hologram recording channel) are also reported. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods and algorithms for computer synthesis of holographic elements to obtain a complex impulse response of optical information processing systems based on modern spatial light modulators

The possibilities of designing optical devices for data processing and imaging based on the manipulation of coherent light beams by means of spatial light modulators (SLMs) are investigated. A review of commercially available SLMs is presented and the limitations of their complex modulation characteristics are analysed. The main problem of using present-day SLMs is the lack of the ability to modulate directly all states within a unit circle in the complex plane. In this regard, the characteristics of current methods for the synthesis of holographic elements are described that implement a given complex impulse response of the optical system and are optimal for using SLMs with purely amplitude, purely phase, and hybrid amplitude – phase modulation. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-colour digital holographic microscopy based on a Mach – Zender interferometer and a solid-state RGB laser

We have developed a facility for recording colour digital holograms involving a Mach – Zender interferometer and a pulsed solid-state RGB laser, which radiates simultaneously at three wavelengths: 451, 532, and 634 nm. These wavelengths are obtained in the conversion of the radiation of a pulsed Nd{sup 3+} : YAG laser (1064 nm), which operates in the regime of intracavity parametric oscillation at a wavelength of 1570 nm, with the subsequent conversion of its frequencies to the red, green, and blue spectral regions in nonlinear KTP-crystal elements. The combination of this three-wavelength pulsed light source with the Mach – Zender interferometer provides the simultaneous recording of three spectral digital holograms with one matrix RGB radiation detector. Pulsed three-colour digital holography shows promise for the analysis of fast processes and rapidly varying colour phase objects. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Bragg grating inscription in photosensitive materials by an optical replication process

This paper examines the feasibility of producing multiplexed Bragg gratings for use as diffractive optical elements (DOEs) by coherent optical replication of a surface-relief phase grating into thick-film photosensitive materials. The use of such DOEs in light guide plates (LGPs) for optical imaging systems ensures energy-efficient light input into and output from LGPs and allows one to minimise their weight and size. We present simulation results for the interference structure fabrication process and recording of a series of multiplexed diffraction gratings in photosensitive materials. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Holographic reflective Bragg gratings of gain and their role in the operation of high-power pulsed lasers

The influence of reflective Bragg gratings that are formed in an active medium due to the spatial periodic modulation of gain on the spectral properties of lasing are investigated by an example of a pulsed Nd : YAG laser. It is shown that, at a certain choice of the formation regime of reflective gratings of gain, the lasing bandwidth can be reduced by a factor of 3 – 5, with a corresponding increase in the pulse energy and significant improvement of spatial beam quality. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modelling of the laser amplification process with allowance for the effect of the temperature distribution in an Yb : YAG gain element on the thermophysical and lasing characteristics of the medium

A time-dependent three-dimensional model for the laser amplification process has been constructed with allowance for the effect of the temperature distribution on the thermophysical and lasing characteristics of gain media. We have performed numerical modelling of the laser amplification process in the gain elements of a two-stage subjoule-level cryogenic laser amplifier operating at a pulse repetition rate of up to 1 kHz. It has been shown that taking into account the temperature distribution is of critical importance in calculation of cryogenically cooled laser amplifiers pumped with high-power diodes. We have found optimal diode pump parameters at which the maximum achievable pulse energy at the amplifier output can reach 300 and 570 mJ at pulse repetition rates of 1000 and 500 Hz, respectively. (extreme light fields and their interaction with matter)

42 ENGINEERING↗

Photoacoustic methane gas analyser based on a 3.3-μm optical parametric oscillator

We demonstrate a bench-scale prototype of a photoacoustic (PA) methane gas analyser that takes advantage of an optical parametric oscillator (OPO) based on a fan-out MgO : PPLN structure and resonant differential PA detector. The OPO emits in a repetitively pulsed mode (∼1750 Hz) at an idler wavelength of ∼3.3 μm with an average power of ∼40 – 50 mW. Using the prototype laser PA gas analyser, we experimentally demonstrate the feasibility of measuring the background methane concentration in air (∼2 – 3 ppm of CH{sub 4}). The threshold sensitivity of the PA gas analyser (1σ) is determined to be ∼ 49 ppb of CH{sub 4}. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trapping of lithium atoms in a large hollow optical dipole trap

We describe the trapping of lithium atoms in an optical dipole trap about 1 mm in size, with a nearly rectangular potential. The trap has the shape of a cylinder with flat bases. The confinement region is bounded by thin walls produced by light with a frequency blue-detuned from an atomic transition (resonance) frequency by 19 GHz. Before trapping, the gas is collected and cooled in a magneto-optical trap whose centre nearly coincides with the centre of the dipole trap. After switching off the magneto-optical trap, we have photographed the atoms remaining in the dipole trap. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗