Search NASA⌕ Search

SEARCH · Search NASA

Results for “Medical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Dose Coefficient Calculation for Use in Dosimetry Assessment of a Fission-Based Weapon

In the event of a fission-based weapon or improvised nuclear device (IND) detonation, dose coefficients can be harnessed to provide dose assessments for defense, emergency preparedness, and consequence management, as well as to prospectively inform the assessment of radiation biomarkers and development of medical prophylaxis countermeasures for defense and homeland security stakeholders and decision-makers. Although dose coefficients have previously been calculated for this group, they would apply specifically to the studied population, the 1945 Japanese cohort, after which their anthropomorphic computational phantoms were modeled. For this reason, applications to other populations may be limited, and instead, an assessment of a more standardized population is desired. We employed a series of computational human phantoms representing international reference individuals: UF/NCI voxel phantom series containing newborn, 1-, 5-, 10-, 15-, and 35-year-old males and females. Irradiation of the phantoms was simulated using the Monte Carlo N-Particle transport code to determine organ dose coefficients under four idealized irradiation geometries at three distances from the detonation hypocenter at Hiroshima and Nagasaki using DS02 free-in-air prompt neutron and photon fluence spectra. Through these simulations, age-specific dose coefficients were determined for individual organs. Various articulated PIMAL stylized phantoms were simulated as well to estimate the effect of body posture on dose coefficients and determine the effect of posture on dosimetric estimation and reconstruction. Results additionally demonstrate that 137 Cs and the Watt fission spectra are not ideal general surrogate sources for fission weapons, which may be considered for experimental testing of medical countermeasures. Supplementary data provided tabulates the compilation of organ dose-rate coefficients in this study.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A new center for heavy ion research

Progress in cancer therapy with ions heavier than protons, i.e., helium, carbon, oxygen and neon, requires research and development capability. Ion research activity, however, is limited from the absence of U.S. accelerator facilities offering ion beams for therapy – placing the U.S. significantly behind Europe and Asia. With dramatic advances in beam delivery and compact accelerators, the potential exists to create a facility that can play a leadership role in particle therapy and ion-based research. This paper announces summary details of a new center for ion therapy research under construction in Waco, TX, in collaboration with recognized accelerator entities both academic and industrial. The advanced accelerator technologies will produce beams for both clinical and research applications, offering a complete range of ions, intensities and energies required by the medical community, including the capability to perform ultra-high dose irradiation (FLASH) research. FLASH, a recent research initiative, which has the potential of reducing cancer treatment toxicities, is an important if not critical capability for a competitive research center – requiring beam intensities well beyond those provided by current medical accelerators. Building a state-of-the-art cancer research center within a comprehensive facility will provide the resources to promote ion therapy in the U.S, including, preclinical/clinical trials and protocols between modalities, and also support broad ion R&D.

43 PARTICLE ACCELERATORS↗

Design Optimization of A generic Fissile Solution for Mo99 production using Electron Beam-based Neutron Generator using MCNP+CFD

Molybdenum-99 ( 99 Mo) is a medical isotope used in 80% of all medical imaging procedures today. However, 99 Mo is not directly administered to patients for imaging; its decay product, technetium-99m ( 99 mTc), is a metastable isotope with a half-life of ~6 hours. Such a short half-life does not allow for production, separation, and application to a patient before decaying further. Therefore, the solution is to produce the precursor to 99 mTc, 99 Mo. 99 Mo has a half-life of 66 hours, long enough to produce the material and send it to the desired location before it fully decays. Under National Nuclear Security Administration’s (NNSA) highly enriched uranium (HEU) minimization mission, the Material Management and Minimization (M3) office leads the Molybdenum-99 (Mo-99) program. A major goal of the Mo-99 program is to develop methods of producing 99 Mo using low enriched uranium (LEU) opposed to the traditionally used HEU domestically in the U.S. Internationally, LEU is the new standard for use in research reactors and isotope production facility. In this study, we introduce a generic fissile solution system for 99 Mo production facility meeting the design requirement of 1) LEU usage as fissile material and 2) subcritical fissile system coupled with a horizontal electron beam (E-beam) accelerator. The focus of this research is to optimize a fissile solution configuration for maximum 99 Mo production yield using MCNP model, and ultimately implement the optimized design with computational fluid dynamics (CFD) model to understand thermal hydraulic behavior and solution convection characteristic. The report consists of two parts: 1) isotope yield calculation and criticality analysis with a wide range of parametric test matrix, and 2) thermal hydraulic analysis for solution mixing and cooling assessment.

60 APPLIED LIFE SCIENCES↗

Filter Adapters for BI-PAP and CPAP Equipment

Researchers at Los Alamos National Laboratory are researching and designing technology intended to help reduce the exposure of patients and medical staff to pathogens, such as SARS-CoV-2, while providing medical staff the dexterity and flexible work conditions necessary to conduct routine and complex patient care on infected patients. This investigative technology would potentially enable hospitals to adapt, utilize, and repurpose existing Bilevel Positive Airway Pressure (BiPAP) or Continuous Positive Airway Pressure (C-PAP) equipment in the fight against COVID-19, which would potentially save hospitals significant money, reduce exposure to staff and patients, and increase the supply of critically needed devices at a time when supplies are scarce in the market place. A provisional patent has been filed on the technology and we are seeking a commercialization partner to license and further develop the product for commercial purposes, including processing the device through the FDA emergency use authorization or clearance process. One hospital system has indicated that upon FDA authorization or clearance, it would have interest in the product.

42 ENGINEERING↗

Air Evacuation Bridge

Researchers at Los Alamos National Laboratory are researching and designing technology intended to help reduce the exposure of patients and medical staff to pathogens, such as SARS-CoV-2 while providing medical staff the dexterity and flexible work conditions necessary to conduct routine and complex patient care on infected patients. This investigative technology would potentially enable hospitals to adapt, utilize, and re-purpose existing and otherwise infrequently used equipment in the fight against COVID-19, thereby saving hospitals significant money, reducing exposure to staff and patients, and increasing the supply of critically needed devices at a time when supplies are scarce in the market place. A provisional patent has been filed on the technology and we are seeking a commercialization partner to license and further develop the product for commercial purposes, including processing the device through the FDA authorization or clearance process. Once FDA has cleared the product, at least one hospital system has expressed interest in the experimental test components for use in their hospitals.

42 ENGINEERING↗

Performance of Scintillation Detectors Based on Quantum Dots in a Semiconductor Matrix (Final Technical Report)

InAs Quantum Dots (QDs) embedded into GaAs semiconductor waveguide have unique scintillation properties, valuable for nuclear security, medical imaging, and high energy physics. In this work, we developed thick (~25um) epitaxial heterostructres with high luminescence efficiency composed of self-assembled nano-engineered InAs QDs grown by molecular beam epitaxy. In this type of detector, the GaAs matrix acts as a stopping material for charged particles or photons generating electrons captured by the QDs acting as luminescence centers. The QD medium is designed to provide fast capture of electrons into QDs (few ps), high QD luminescence efficiency at room temperature (>50%), and strong red-shift of photoluminescence (PL) from the GaAs absorption edge (>250nm). Typical devices consist of a 10-25um thick GaAs layer with embedded sheets of modulation p-type doped InAs QDs and an InGaAs photodetector tuned to the QD emission wavelength. The thick GaAs layer acts also as a waveguide when layer-transferred onto a low-index substrate. Waveguiding and self-absorption (~1cm -1 ) were studied using photoluminescence with scanning laser excitation and modeled with ray optics approximation and geometrical coupling of high-index waveguide to a collection fiber. Scintillating signals from α-particles were analyzed with both an external photodiode (PD) and an integrated PD which provided an improved optical coupling. In the former case, the external InGaAs PD was air-coupled to the scintillator and had the light collection efficiency of about 1% corresponding to limited light extraction through a planar interface with air due to total internal reflection. The mean charge collected by the integrated PD was in the range of (3÷5)×10 4 photoelectrons per 1 MeV of deposited energy, or ~13-20% of the theoretically achievable light yield. Timing of the integrated device was measured by wire-bonding it to the input of an 8 GHz IC. The scintillation response shows an extremely fast 0.3-0.6 ns decay constant and about 40-70 ps time resolution, limited by the system noise. The combined light yield and decay time makes the InAs/GaAs QD heterostructures the fastest high yield scintillation material reported making it valuable for high energy physics and medical imaging applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Uncertainty Analysis Framework for the Hospital Resource Supply Model for Covid-19

In March and April of 2020 there was widespread concern about availability of medical resources required to treat Covid-19 patients who become seriously ill. A simulation model of supply management was developed to aid understanding of how to best manage available supplies and channel new production. Forecasted demands for critical therapeutic resources have tremendous uncertainty, largely due to uncertainties about the number and timing of patient arrivals. It is therefore essential to evaluate any process for managing supplies in view of this uncertainty. To support such evaluations, we developed a modeling framework that would allow an integrated assessment in the context of uncertainty quantification. At the time of writing there has been no need to execute this framework because adaptations of the medical system have been able to respond effectively to the outbreak. This report documents the framework and its implemented components should need later arise for its application.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Irradiation of 20L LEU Uranyl Sulfate Solution for Production of Mo-99

Argonne National Laboratory, with support from the National Nuclear Security Administration’s Office of Material Management and Minimization, is assisting SHINE Medical Technologies in the development of accelerator-driven production of 99 Mo using low-enriched uranium (LEU). Technetium-99m ( 99m Tc), a daughter of 99 Mo, is a workhorse of nuclear medicine, used in approximately 40,000 medical testing procedures each day just in the U.S.

07 ISOTOPE AND RADIATION SOURCES↗

Breakthrough MEG Technology [Slides]

LANL technology is a disruptive innovation to change market dynamics. For medical imaging experts who want to rapidly diagnose brain disorders, our LANL breakthrough MEG solution delivers faster and easier brain imaging without having to go to major urban medical centers.

59 BASIC BIOLOGICAL SCIENCES↗

Welded and Hydrogen Charged Zircaloy-4 and Welded Stainless Steel 347 Property Data and Microstructures for the Target Solution Vessel and Support Lines of SHINE

SHINE Medical Technologies is developing a facility that will produce molybdenum-99 for medical isotope procedures. As part of this facility, a metal tank, called the target solution vessel (TSV), will hold a uranyl sulfite solution. The TSV must withstand neutron irradiation near room temperature and potential corrosion from the aqueous solution. The large cylindrical TSV will be fabricated by welding and will have numerous pipes and connections also attached via welding. The vessel and those pipes will have varying thicknesses so both gas tungsten arc welding (GTAW) and flux-cored arc welding (FCAW) will be necessary to fabricate different sections. The original material under consideration for the TSV was Zircaloy-4 (Zry-4), but it is known to form a hydride which can degrade its mechanical properties. Thus, some investigation here is focused on the effects of hydrogen uptake in the Zry-4. Additionally, the alternative material being considered is AISI 347, a stainless steel. Both materials have little existing data for their neutron irradiation behavior below 100°C, and both have open questions on the weld behavior under neutron irradiation. Testing has focused on characterizing their weld properties with tensile tests and performing neutron irradiation of samples in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL).

07 ISOTOPE AND RADIATION SOURCES↗

Computed Tomography Scanning and Geophysical Measurements of the Wabash No.1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize Mt. Simon core from the Wabash CarbonSAFE project, Wabash No. 1 well. The primary impetus of the work in this report is a collaboration between NETL Research and Innovation Center and the Illinois State Geological Survey at the Prairie Research Institute, University of Illinois Urbana-Champaign in Champaign, Illinois. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/wabash-no-1-well. The Wabash No. 1 well was drilled as part of a U.S. Department of Energy (DOE) funded Carbon Storage Assurance Facility Enterprise field project to assess the feasibility of developing a commercial-scale geological storage complex at the Wabash Valley Resources Integrated Gasification Combined Cycle plant near Terre Haute, Indiana. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in fine-grained structures; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy-related examinations traditionally performed at NETL.

54 ENVIRONMENTAL SCIENCES↗

Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop

The Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop fostered engagement across disciplines on critical topics that impact the development of targeted radionuclide therapies, bringing together scientific and medical professionals actively involved in radiotherapeutic design, optimization testing, patient treatment, and clinical trials along with basic science researchers, whose novel techniques have the potential to further our understanding of targeted radionuclide therapy. Discussion of the applications of radiotherapeutics to pediatric and adult, brain, prostate and blood cancers, and metastatic disease allowed scientific research to be presented in the context of real-world medical applications and provided an important backdrop to the basic research performed in computers, laboratories, and animal facilities. The workshop format, presentations, and panel discussions were designed to consider a holistic approach to the development of systemic and targeted radiotherapies, integrating radiobiology and microdosimetry, biological assessments on the microscale, and physiologically relevant models of tumor and tissue microenvironments. Important needs highlighted in the workshop include better models to assess the biological effects of radionuclide therapy, novel strategies to target radiotherapeutics to disease sites with high specificity, and new dosimetry techniques that address the importance of tumor microenvironments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Core Characterization of Bakken Shale from the Bedwell 33-52-1-1H Well, Sheridan County, Montana

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core of the Bedwell 33-52-1-1H well (API 25-091-21920), a wildcat field in Sheridan County, Montana. The primary impetus of this work is to provide a unique dataset to researchers at universities, national laboratories, geological surveys, and other locations for additional analyses. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/bedwell-33-52-1-1h-well. The equipment and techniques used to characterize the full core were non-destructive, enabling future examinations and analyses to be performed on these cores. However, none of the equipment used was suitable for direct visualization of the pore space in fine-grained structures such as those found in shales; fractures, discontinuities, and millimeter scale features were readily detectable with the methods tested. Imaging with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis. A selection of samples (Table 1) were cored, sliced, and powdered for additional characterization analyses. These analyses did involve destructive subsampling of the full core at discrete sections, and the results are presented here in the context of the larger core description. Selected sections of the core were removed from the full core for detailed analyses using the following destructive techniques: bulk inductively coupled plasma-optical emission spectroscopy (ICP-OES), isolation of carbon and sulfur, Fourier transform infrared (FTIR) spectroscopy, scanning electron microscopy (SEM), and higher resolution CT scan with NETL’s micro-CT scanning systems. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

04 OIL SHALES AND TAR SANDS↗

Separation and purification of Mo-99 produced from natural U 3 0 8 targets via photo-fission

The most-used medical isotope is 99m Tc (t½ = 6.0 h), which comprises over 80% of isotopes used in nuclear medicine today. It is normally derived from its transient equilibrium parent 99 Mo (t½ = 66 h). A recent surge of interest in using the more proliferation-resistant low-enriched uranium (LEU) under the American Medical Isotope Production Act (AMIPA) has presented this technical challenge: can a domestic supplier meet the estimated weekly U.S. demand of 1500 6–day Ci of 99 Mo?

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Current and Future Work on Wound Contamination by Alpha Emitters at Los Alamos [Slides]

Our team calculated ‘clinical decision levels’ at which treatment may be warranted (i.e., bioassay and wound measurements which correspond to specific dose thresholds). The actual risk to the patient corresponding to this dose threshold is uncertain – the CED may not tell the whole story. We recently reviewed LANL medical records to characterize adverse events associated with treatment. Future work should include medical records from other institutions and a review and analysis of data to quantify benefit of treatment with a focus on the question, "What factors predict whether treatment will be beneficial?"

61 RADIATION PROTECTION AND DOSIMETRY↗

Monte Carlo Simulations in Support of NorthStar Irradiation Facility Commissioning Procedure

NorthStar Medical Radioisotopes LLC is constructing an irradiation facility at which electron accelerators will induce photo-transmutation (i.e., neutron knockout) of molybdenum-100 (Mo-100) to produce medically useful Mo-99. The facility will house two high-intensity electron RhodotronTM accelerators developed by IBA Industrial. The nominal power of each Rhodotron is 125kW at 40 MeV beam energy. The production target is made of metallic molybdenum enriched with Mo-100 isotope. It will be irradiated by electron beams and will itself play a role in electron conversion to intense X-rays. A full description of the NorthStar target as well as the concept of radiation shielding of the facility can be found in our previous report. The NorthStar irradiation facility is under commissioning now. The goal of the present work is to support the commissioning process by: (1) Studying residual radiation and activation to minimize personnel exposure and inform radiation waste management; (2) Using computational fluid dynamics (CFD) of the irradiated target to ensure the facility design is safe and reliable; and (3) Helping to determine radiation protection requirements during operation. Monte Carlo simulations are used for the analyses. Most of the results are presented as 3D arrays representing spatial distribution of values across simulated geometries: radiation energy depositions, ambient doses, residual isotopes accumulated, and residual doses.

07 ISOTOPE AND RADIATION SOURCES↗

U.S. Department of Energy: National Virtual Biotechnology Laboratory (Technical Report)

With funding from the CARES Act, the U.S Department of Energy (DOE) established the National Virtual Biotechnology Laboratory (NVBL) in March 2020 to address key challenges associated with the COVID-19 crisis. The NVBL brought together the broad scientific and technical expertise and resources of DOE’s 17 national laboratories to help tackle medical supply shortages, discover potential drugs to fight the virus, develop and validate COVID-19 testing methods, model disease spread and impact across the nation, and understand virus transport in buildings and the environment. National laboratory resources leveraged for this effort include a suite of world-leading user facilities broadly available to the research community, such as light and neutron sources, nanoscale science research centers, sequencing and biocharacterization facilities, and high-performance computing facilities. As part of the NVBL framework, DOE rapidly assembled five project teams to (1) identify new targets for medical therapeutics; (2) develop innovations in testing capabilities; (3) provide epidemiological and logistical support; (4) understand viral fate and transport in the environment; and (5) address supply chain bottlenecks by harnessing extensive additive manufacturing capabilities. Each research team was charged with defining high-impact projects that could be completed in a 6-month sprint while coordinating their developments with academia, other government agencies, and the private sector. Within months, NVBL teams used DOE’s high-performance computers and light and neutron sources to identify promising candidates for antibodies and antivirals that universities and drug companies are now evaluating. NVBL researchers also developed new diagnostic targets and sample collection approaches, and supported efforts by the U.S. Food and Drug Administration, Centers for Disease Control and Prevention, and U.S. Department of Defense to establish national guidelines used in administering millions of tests. Researchers used artificial intelligence and high-performance computing to produce near-real-time data analysis to forecast disease transmission, stress on public health infrastructure, and economic impact, which supported decision-makers at the local, state, and national levels. To minimize virus uptake and protect human health, NVBL teams studied how to control indoor virus movement. Researchers also produced innovations in materials and advanced manufacturing that mitigated shortages in test kits and personal protective equipment, creating nearly 1,000 new jobs. Through its NVBL framework, DOE has contributed significantly to the nation’s COVID response, demonstrating in only a few months the critical impact of its national laboratories. NVBL’s accomplishments demonstrate not only the powerful resource represented by DOE’s national laboratories working together to meet national needs, but also the effectiveness of the integrated NVBL framework for rapidly responding to emergencies with research and development solutions. Going forward, the NVBL is poised to apply the unique capabilities and expertise of the national laboratory complex to future national and international emergencies, both natural and engineered. Through this framework, DOE will continue to be an integral component of agency-wide efforts to prepare for and respond to biorisks and other crises. This technical report describes the goals, progress, and results of NVBL’s five project teams—Molecular Design for COVID-19 Therapeutics, COVID-19 Testing, Epidemiological Modeling, Viral Fate and Transport, and Materials and Manufacturing of Critical Supplies—and lists each team’s publications and research output.

42 ENGINEERING↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗