Search NASA⌕ Search

SEARCH · Search NASA

Results for “Metrology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Quantum Metrology of Noisy Spreading Channels

We provide the optimal measurement strategy for a class of noisy channels that reduce to the identity channel for a specific value of a parameter (spreading channels). We provide an example that is physically relevant: the estimation of the absolute value of the displacement in the presence of phase randomizing noise. Surprisingly, this noise does not affect the effectiveness of the optimal measurement. We show that, for small displacement, a squeezed vacuum probe field is optimal among strategies with same average energy. A squeezer followed by photodetection is the optimal detection strategy that attains the quantum Fisher information, whereas the customarily used homodyne detection becomes useless in the limit of small displacements, due to the same effect that gives Rayleigh’s curse in optical superresolution. There is a quantum advantage: a squeezed or a Fock state with N average photons allow to asymptotically estimate the parameter with a N better precision than classical states with same energy.

Górecki, Wojciech↗

Ultraviolet Fluorescence Imaging for Photovoltaic Module Metrology: Best Practices and Survey of Features Observed in Fielded Modules

As the photovoltaics (PV) industry grows in sophistication, so must the extent to which systems are characterized. UV Fluorescence (UVF) imaging is a valuable, easy-to-perform, high-throughput, nonintrusive technique for characterizing modules in the field and in the lab. However, UVF is still a relatively new technique, and many in the PV industry are still unaware of its potential. We provide a guideline for obtaining, processing, and interpreting UVF images. We have provided a list of considerations for imaging hardware and settings, a suggested pipeline for image processing, and details on a survey of features shown in UVF images. As a result, a new database with UVF images of 7190 modules and another database curated by BrightSpot Automation are publicly available.

14 SOLAR ENERGY↗

Applied Metrology for the Assembly of the Nb 3 Sn MQXFA Quadrupole Magnets for the HL-LHC AUP

The US HL-LHC Accelerator Upgrade Project (AUP) is building Nb 3 Sn quadrupole magnets, called MQXFA, with plans to install 16 of them in the HL-LHC Interaction Regions. Variability in coil size must be dealt with at the assembly level, which requires timely and repeatable measurement of each coil. In this paper we will present the methodology used for coil measurements and the geometrical size data for the coils that have been measured thus far. We will also show the coil measurements of 8 coils before and after cold test. In conclusion, the Leica AT960-MR laser tracker with Spatial Analyzer software acquired to achieve these measurements has been used elsewhere in the project to great effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Increased phase precision of spatial light modulators using irrational slopes: application to attosecond metrology

The ability of spatial light modulators (SLMs) to modify the amplitude and phase of light has proved them invaluable to the optics and photonics community. In many applications, the bit-depth of SLMs is a major limiting factor dictated by a digital processor. As a result, there is usually a compromise between refresh speed and bit-depth. Here, we present a method to increase the effective bit-depth of SLMs, which utilizes a linear slope, as is commonly applied to deal with the zeroth-order effect. This technique was tested using two interferometric transient absorption spectroscopy setups. Through the high harmonic generation in gases producing a train of attosecond pulses and harmonics from solids in the ultraviolet, two pulses are generated that interfere in the far field providing a measurement of the optical phase. An increase in the precision far beyond the limit dictated by the digital processor in the bit-depth was found.

Harrison, Geoffrey R. (ORCID:0000000152141866)↗

Milliradian precision ultrafast pulse control for spectral phase metrology

A pulse-shaper-based method for spectral phase measurement and compression with milliradian precision is proposed and tested experimentally. Measurements of chirp and third-order dispersion are performed and compared to theoretical predictions. The single-digit milliradian accuracy is benchmarked by a group velocity dispersion measurement of fused silica.

Stamm, Jacob↗

Real-time single-element-detection structured illumination optical metrology for laser powder bed fusion

Laser powder bed fusion (LPBF) is a type of metal additive manufacturing which could benefit from improved process monitoring to improve quality control. We demonstrate, for the first time to our knowledge, the coaxial monitoring of melt track formation in steel powder with spatial frequency modulation imaging (SPIFI), an enhanced-resolution imaging technique which uses a photodiode to record one-dimensional images. Using a custom live-display software and a high-speed SPIFI geometry, we offset the SPIFI field of view from the fusing beam to monitor different regions of the LPBF melt pool and surrounding area. This demonstrates the potential of SPIFI to monitor spatial features within the melt pool in real-time with increased data efficiency.

Hunter, Scott (ORCID:0009000886150312)↗

X-ray Computed Tomography as a Metrology Technique for the Analysis of Additively Manufactured Material

X-ray computed tomography (X-ray CT) is an analytical technique used in materials science to non-destructively characterize features in a variety materials like polymer, metals, composites, and explosives. It also has the capability of imaging additively manufacture, machine and assembled parts. The non-destructive imaging allows for the analysis of features (voids and cracks), which give a fundamental understanding of the material characteristics. Additionally, X-ray CT can obtain accurate measurements of dimensional and topographic variations due to different stimuli and assess the accuracy of material production. This study focuses on parts manufactured via metal additive manufacturing (AM). Although AM produces parts faster and easier, the printing process can produce defects (pores and surface roughness) that undermine the part’s mechanical properties and performance. The analysis of 3D printed objects has an asset in that the material has an STL file from which the item was printed, which is not available in many manufactured materials (i.e., foams) due to stochastic structures. For this study, the print accuracy of four additively manufactured cylinders will be assessed via X-ray CTto approximate the surface roughness and visualize any major morphological changes to assess the dimensional accuracy of complex additively manufactured parts. It was concluded that using X-ray CT to measure surface roughness was affective because reasonable surface roughness values were measured. Additionally, itwas determined that small-scale features can be produced via additive manufacturing with strong dimensional accuracy so long as the features are highly complex with sharp grooves.

36 MATERIALS SCIENCE↗

AGR-5/6/7 Irradiation Disassembly and Metrology First Look

The Advanced Gas Reactor (AGR) Fuel Development and Qualification Program was established to perform research and development on tristructural isotropic (TRISO)-coated particle fuel to support deployment of high-temperature gas-cooled reactors (HTGRs), which are graphite-moderated nuclear reactors cooled with helium. This work continues as part of the Advanced Reactor Technologies (ART) TRISO Fuel Program. The overarching program goal is to provide a baseline fuel qualification data set to support licensing, deployment, and operation of HTGRs in the United States. To achieve these goals, the program includes fuel fabrication, irradiations of TRISO fuels and high-temperature materials (e.g., graphite), safety testing and post-irradiation examination (PIE), fuel performance modeling, and fission product transport and source term determination. The ART AGR program has conducted four distinct fuel irradiation experiments in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL). The first of these irradiation tests, designated AGR-1, began in ATR in December of 2006 and ended in November 2009. This experiment was primarily to act as a shakedown test of the multi-capsule test train design and to provide early data on fuel performance that would be used in fuel fabrication process development. AGR-1 fuel kernels were produced on an engineering scale, but the TRISO coatings and cylindrical fuel compacts were fabricated on a laboratory scale. The AGR-1 PIE was completed and the final report was published in 2015. The second irradiation test, AGR-2, started in ATR in June 2010 and ended in October 2013. The AGR-2 irradiation test was designed to provide fuel performance data for coated particles fabricated on an engineering-scale pilot line using a coater with an internal chamber diameter of 150 mm (6 in.). The final PIE report was published in 2021. AGR-3/4, a single irradiation that combined what were originally conceived as the third and fourth tests, was to support the refinement of fission product transport models and to assess the effects of sweep gas impurities on fuel performance and fission product transport. PIE of the AGR-3/4 experiment is still in progress as of this writing. The subject of this report is AGR-5/6/7, the final qualification test of AGR TRISO fuel made entirely at the engineering scale.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗