Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microscope and microscopy.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Hard-X-Ray Phase-Difference Microscopy Using a Fresnel Zone Plate and a Transmission Grating

Novel hard x-ray phase imaging microscopy that simply uses an objective and a transmission grating is described. The microscope generated an image that exhibited twin features of a sample with an opposite phase contrast having a separation of a specific distance. Furthermore, the twin features were processed to generate an image mapping the x-ray phase shift through a simple algorithm. The presence of the grating did not degrade the spatial resolution of the microscope. The sensitivity of our microscope to light elements was about 2 orders of magnitude higher than that of the absorption contrast microscope that was attained by simply removing the grating. Our method is attractive for easily appending a quantitative phase-sensitive mode to normal x-ray microscopies, and it has potentially broad applications in biology and material sciences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Stroboscopic ultrafast imaging using RF strip-lines in a commercial transmission electron microscope

The development of ultrafast electron microscopy (UEM), specifically stroboscopic imaging, has brought the study of structural dynamics to a new level by overcoming the spatial limitations of ultrafast spectroscopy and the temporal restrictions of traditional TEM simultaneously. Combining the concepts governing both techniques has enabled direct visualization of dynamics with spatiotemporal resolutions in the picosecond-nanometer regime. Here, in this study, we push the limits of imaging using a pulsed electron beam via RF induced transverse deflection based on the newly developed 200 keV frequency-tunable strip-line pulser. We demonstrate 0.2 nm spatial resolution at high magnifications and elucidation of Lorentz imaging using the phase-microscopy method. We also present beam coherence measurements and expand our study using the breathing modes of a silicon interdigitated comb under RF excitation which achieves improved temporal synchronization between the electron pulse-train and electric field. A new RF holder has also been developed with impedance matching to the RF signal to minimize transmission power loss to samples and its performance is compared with a conventional sample holder.

47 OTHER INSTRUMENTATION↗

Novel Applications of Scanning Ultrafast Electron Microscopy (SUEM)

The Scanning Ultrafast Electron Microscope (SUEM) was used to image a wide array samples using a variety of standard and non-standard operating conditions on a custom system built in Org. 8942. The ability of this technique to produce high-quality images was assessed during this one year LDRD. To obtain details about the devices imaged, as well as the experimental details, please refer to the classified report from the project manager, Rich Dondero, or the NSP IA lead, Kristina Czuchlewski.

47 OTHER INSTRUMENTATION↗

An ultrahigh vacuum multipurpose specimen chamber with sample introduction system for in situ transmission electron microscopy investigations

A commercial transmission electron microscope (TEM), with flat-plate upper pole piece configuration of the objective lens, and top-entry specimen introduction was modified by introducing an ultrahigh vacuum (UHV) specimen chamber for in situ TEM experimentation. The pumping and design principles and special features of this UHV chamber, which makes it possible to obtain 5 x 10 to the -10th mbar pressure at the site of the specimen, while maintaining the airlock system that allows operation in the 10 to the -10th mbar range within 15 min after specimen change, are described. Design operating pressures and image quality (resolution of metal particles smaller than 1 nm in size) were achieved. Schematic drawings and design dimensions are included.

Heinemann, K.↗

Cryotomography x-ray microscopy state

An x-ray microscope stage enables alignment of a sample about a rotation axis to enable three dimensional tomographic imaging of the sample using an x-ray microscope. A heat exchanger assembly provides cooled gas to a sample during x-ray microscopic imaging.

Le Gros, Mark↗

Combined Apertureless Near-Field Optical Seconde-Harmonic Generation/Atomic Force Microscopy Imaging and Nanoscale Limit of Detection

A dual atomic force/near-field scanning optical microscope (AFM/NSOM) with an 800-nm ultrafast laser excitation source was used to investigate apertureless, tip-enhanced second harmonic generation (SHG) of ZnO nanowires. Data from far-field single-particle SHG microscopy images and spectra show little to no contributions from band-gap or other emission. The SHG microscope image and the simultaneous tapping mode AFM and apertureless SHG NSOM images indicate that ZnO nanowires exhibit a strong SHG signal consistent with uniform crystallinity, whereas other ZnO particles found with the wires had a variable, weaker SHG signal. Polarization data established values for Chi(33)/Chi(31) close to previous estimates. Our AFM/SHG NSOM data suggest a particle degradation mechanism under atmospheric conditions starting at the endpoints of the nanowire.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Squeezing Noise in Microscopy with Quantum Light

Quantum-enhanced microscopes capable of probing classically inaccessible material properties have drawn increasing interest, but most proof-of-principle quantum microscopes have not surpassed classical limits. Here, we discuss the promise and obstacles associated with the use of quantum light with reduced noise (‘squeezed’ light) for quantum-enhanced atomic force microscopy, bioimaging, magneto-optical measurements, and Raman spectroscopy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Influence of Polarization Setting on Gold Nanorod Signal at Nonplasmonic Wavelengths Under Differential Interference Contrast Microscopy

Researchers rely on a variety of microscopic techniques for observing and tracking anisotropic nanoparticles in real time experiments. This technical note focuses on the optical behavior exhibited by gold nanorods at nonplasmonic wavelengths under differential interference contrast microscopy (DIC). Intense diffraction patterns appear at nonplasmonic wavelengths, and the behavior of these patterns can be altered by adjusting the surrounding medium or the polarizer setting. Such patterns are absent when linear and crossed polarizations are utilized. Making polarization adjustments is important in DIC microscopy, because it affects bias retardation and image contrast. The nonplasmonic diffraction bands that were observed could potentially be exploited for rotational tracking, but more importantly, researchers should exhibit care in selecting a nanorod sample and the polarization setting when working with DIC microscopy.

36 MATERIALS SCIENCE↗

Solid Phase Characterization of Tank 241-AY-102 Annulus Space Particulate

The Special Analytical Studies Group at the 222-S Laboratory (222-S) examined the particulate recovered from a series of samples from the annular space of tank 241-AY-102 (AY-102) using solid phase characterization (SPC) methods. These include scanning electron microscopy (SEM) using the ASPEX® scanning electron microscope, X-ray diffraction (XRD) using the Rigaku® MiniFlex X-ray diffractometer, and polarized light microscopy (PLM) using the Nikon® Eclipse Pol optical microscope. The SEM is equipped with an energy dispersive X-ray spectrometer (EDS) to provide chemical information.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory-size three-dimensional water-window x-ray microscope with Wolter type I mirror optics

We constructed a laboratory-size three-dimensional water-window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques. It consists of an electron-impact x-ray source emitting oxygen Kα x-rays, Wolter type I grazing incidence mirror optics, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit better than 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm-scale three-dimensional fine structures were resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of coupled vortex gyrations by 70-ps-time- and 20-nm-space-resolved full-field magnetic transmission soft x-ray microscopy

We employed time- and space-resolved full-field magnetic transmission soft x-ray microscopy to observe vortex-core gyrations in a pair of dipolar-coupled vortex-state Permalloy (Ni{sub 80}Fe{sub 20}) disks. The 70 ps temporal and 20 nm spatial resolution of the microscope enabled us to simultaneously measure vortex gyrations in both disks and to resolve the phases and amplitudes of both vortex-core positions. We observed their correlation for a specific vortex-state configuration. This work provides a robust and direct method of studying vortex gyrations in dipolar-coupled vortex oscillators.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laboratory-size three-dimensional x-ray microscope with Wolter type I mirror optics and an electron-impact water window x-ray source

We constructed a laboratory-size three-dimensional water window x-ray microscope that combines wide-field transmission x-ray microscopy with tomographic reconstruction techniques, and observed bio-medical samples to evaluate its applicability to life science research fields. It consists of a condenser and an objective grazing incidence Wolter type I mirror, an electron-impact type oxygen Kα x-ray source, and a back-illuminated CCD for x-ray imaging. A spatial resolution limit of around 1.0 line pairs per micrometer was obtained for two-dimensional transmission images, and 1-μm scale three-dimensional fine structures were resolved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Local triboelectrification of an n-GaAs surface using the tip of an atomic-force microscope

The method of scanning Kelvin-probe microscopy is used to show that the effect of triboelectrification is observed when the tip of an atomic-force microscope interacts with the surface of n-GaAs epitaxial layers. The sign of the change in the potential indicates that the sample surface after triboelectrification becomes more negative. The observed specific features of the phenomena can be attributed to the thermally activated generation of point defects in the vicinity of the sample surface due to deformation caused by the tip.

36 MATERIALS SCIENCE↗

Multivariate statistics applications in scanning transmission electron microscopy X-ray spectrum imaging

A modern scanning transmission electron microscope (STEM) fitted with an energy dispersive X-ray spectroscopy (EDS) system can quickly and easily produce spectrum image (SI) datasets containing so much information (hundreds to thousands of megabytes) that they cannot be comprehensively interrogated by a human analyst. Therefore, advanced mathematical techniques are needed to glean materials science and engineering insight into the processing-structure-properties relationship of the examined material from the SI data. This review will discuss recent advances in the application of multivariate statistical analysis (MVSA) methods to STEM-EDS SI experiments. In particular, the fundamental mathematics of principal component analysis (PCA) and related methods are reviewed, and advanced methods such as multivariate curve resolution (MCR) are discussed. The applications of PCA and MCR-based techniques to solve difficult materials science problems, such as the analysis of a particle fully embedded in a matrix phase are discussed, as well as confounding effects such as rank deficiency that can confuse the results of MVSA computations. Possible future advances and areas in need of study are also mentioned.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Microscopic subsurface characterization of layered magnetic materials using magnetic resonance force microscopy

This project resulted in the following accomplishments: 1) The invention of scanned probe ferromagnetic resonance microscopy. Upon implementation and refinement this approach was used to measure static and dynamic magnetic resonance properties of ferromagnets with an unprecedented combination of spectral and spatial resolution. 2) Demonstration and study of spin pumping in a pristine ferromagnet across a boundary defined entirely by a magnetic field gradient, and so free of materials discontinuities. 3) First demonstrated highly efficient dynamic spin injection from Y 3 Fe 5 O 12 (YIG) into NiO, an antiferromagnetic (AF) insulator and robust spin propagation in AF NiO over distances up to 100-nm thickness; both spin injection and spin transport are mediated by the AF spin correlations. 4) Demonstration of exceptionally high efficiency conversion of spin current to charge current achieved in spin pumping from the dynamic magnetization of a ferromagnetic insulator into a variety of adjacent metal films. 5) Seminal study of the nature of spin-orbit coupling in d-electron metals that revealed the dominant sensitivity of the d-orbital moment to the d-electron count and revealing the important roles of both d-electron configuration and atomic number in the physics of the spin Hall effect. 6) Demonstration of observation of FMR by means of optically-detected NV diamond relaxometry that provided a highly sensitive, spatially resolved FMR detection method and revealed spin pumping across 100-nm length scales by means of dipolar coupling. 7) Using magnetic field localization, developed for FMR imaging, demonstrated a novel approach to discretizing spin wave modes to improve the characteristics of auto-oscillators driven by pure spin currents produced by the spin Hall effect. 8) We demonstrated large spin pumping signals from propagating high wavevector spinwaves in thin film YIG find that the spin pumping efficiency was insensitive to wavevector thus emphasizing the promise of thin YIG films for spinwave-based spintronics by allowing for predictable down-scaling of device dimensions and enabling a broad range of operational frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Transmission electron microscope studies of extraterrestrial materials

Transmission Electron Microscopy, X-Ray spectrometry and electron-energy-loss spectroscopy are used to analyse carbon in interplanetary dust particles. Optical micrographs are shown depicting cross sections of the dust particles embedded in sulphur. Selected-area electron diffraction patterns are shown. Transmission Electron Microscope specimens of lunar soil were prepared using two methods: ion-milling and ultramicrotomy. A combination of high resolution TEM imaging and electron diffraction is used to characterize the opaque assemblages. The opaque assemblages analyzed in this study are dominated by ilmenite with lesser rutile and spinel exsolutions, and traces of Fe metal.

Keller, Lindsay P.↗

Cryogen-free variable temperature scanning SQUID microscope

Scanning Superconducting QUantum Interference Device (SQUID) microscopy is a powerful tool for imaging local magnetic properties of materials and devices, but it requires a low-vibration cryogenic environment, traditionally achieved by thermal contact with a bath of liquid helium or the mixing chamber of a “wet” dilution refrigerator. We mount a SQUID microscope on the 3 K plate of a Bluefors cryocooler and characterize its vibration spectrum by measuring SQUID noise in a region of sharp flux gradient. By implementing passive vibration isolation, we reduce relative sensor-sample vibrations to 20 nm in-plane and 15 nm out-of-plane. A variable-temperature sample stage that is thermally isolated from the SQUID sensor enables measurement at sample temperatures from 2.8 K to 110 K. We demonstrate these advances by imaging inhomogeneous diamagnetic susceptibility and vortex pinning in optimally-doped YBCO above 90 K.

47 OTHER INSTRUMENTATION↗