Search NASA⌕ Search

SEARCH · Search NASA

Results for “Motion Segmentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Template-based CTA to x-ray angio rigid registration of coronary arteries in frequency domain with automatic x-ray segmentation

Purpose: A key challenge for image guided coronary interventions is accurate and absolutely robust image registration bringing together preinterventional information extracted from a three-dimensional (3D) patient scan and live interventional image information. In this paper, the authors present a novel scheme for 3D to two-dimensional (2D) rigid registration of coronary arteries extracted from preoperative image scan (3D) and a single segmented intraoperative x-ray angio frame in frequency and spatial domains for real-time angiography interventions by C-arm fluoroscopy.Methods: Most existing rigid registration approaches require a close initialization due to the abundance of local minima and high complexity of search algorithms. The authors' method eliminates this requirement by transforming the projections into translation-invariant Fourier domain for estimating the 3D pose. For 3D rotation recovery, template Digitally Reconstructed Radiographs (DRR) as candidate poses of 3D vessels of segmented computed tomography angiography are produced by rotating the camera (image intensifier) around the DICOM angle values with a specific range as in C-arm setup. The authors have compared the 3D poses of template DRRs with the segmented x-ray after equalizing the scales in three domains, namely, Fourier magnitude, Fourier phase, and Fourier polar. The best rotation pose candidate was chosen by one of the highest similarity measures returned by the methods in these domains. It has been noted in literature that frequency domain methods are robust against noise and occlusion which was also validated by the authors' results. 3D translation of the volume was then recovered by distance-map based BFGS optimization well suited to convex structure of the authors' objective function without local minima due to distance maps. A novel automatic x-ray vessel segmentation was also performed in this study.Results: Final results were evaluated in 2D projection space for patient data; and with ground truth values and landmark distances for the images acquired with a solid phantom vessel. Results validate that rotation recovery in frequency domain is robust against differences in segmentations in two modalities. Distance-map translation is successful in aligning coronary trees with highest possible overlap.Conclusions: Numerical and qualitative results show that single view rigid alignment in projection space is successful. This work can be extended with multiple views to resolve depth ambiguity and with deformable registration to account for nonrigid motion in patient data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

10. Path Modifiers

Toolpaths for additive manufacturing are typically broken into three types: closed-loop, open-loop, and space-filling. Each of these toolpaths serve a specific purpose and are often used in combination to construct an object. The standard implementation of each toolpath commands a constant motion speed and extrusion rate throughout the length of the path. The 3D printer will then make any necessary adjustments during interpolation of the motion, such as accelerating and decelerating when traversing a corner. However, sometimes more finite control and additional pathing can be needed to ensure the successful printing of a path. This chapter will outline path modifiers and how they can be used to enhance the printability of a toolpath by modifying parameters or adding segments.

Roschli, Alex↗

Examination of geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation therapy

Due to the complicated technical nature of gated radiation therapy, electronic and mechanical limitations may affect the precision of delivery. The purpose of this study is to investigate the geometric and dosimetric accuracies of gated step-and-shoot intensity modulated radiation treatments (SS-IMRT). Unique segmental MLC plans are designed, which allow quantitative testing of the gating process. Both ungated and gated deliveries are investigated for different dose sizes, dose rates, and gating window times using a commercial treatment system (Varian Trilogy) together with a respiratory gating system [Varian Real-Time Position Management system]. Radiographic film measurements are used to study the geometric accuracy, where it is found that with both ungated and gated SS-IMRT deliveries the MLC leaf divergence away from planned is less than or equal to the MLC specified leaf tolerance value for all leafs (leaf tolerance being settable from 0.5-5 mm). Nevertheless, due to the MLC controller design, failure to define a specific leaf tolerance value suitable to the SS-IMRT plan can lead to undesired geometric effects, such as leaf motion of up to the maximum 5 mm leaf tolerance value occurring after the beam is turned on. In this case, gating may be advantageous over the ungated case, as it allows more time for the MLC to reach the intended leaf configuration. The dosimetric precision of gated SS-IMRT is investigated using ionization chamber methods. Compared with the ungated case, it is found that gating generally leads to increased dosimetric errors due to the interruption of the 'overshoot phenomena.' With gating the average timing deviation for intermediate segments is found to be 27 ms, compared to 18 ms for the ungated case. For a plan delivered at 600 MU/min this would correspond to an average segment dose error of {approx}0.27 MU and {approx}0.18 MU for gated and ungated deliveries, respectively. The maximum dosimetric errors for individual intermediate segments are found to deviate by up to {approx}0.64 MU from their planned value when delivered at 600 MU/min using gating, this compares to only {approx}0.32 MU for the ungated case.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of 95 GHz gyrotron based on continuous operation copper solenoid with water cooling

The design work for 2nd harmonic 95 GHz, 50 kW gyrotron based on continuous operation copper solenoid is presented. Thermionic magnetron injection gun specifications were calculated according to the linear trade off equation, and simulated with CST program. Numerical code is used for cavity design using the non-uniform string equation as well as particle motion in the “cold” cavity field. The mode TE02 with low Ohmic losses in the cavity walls was chosen as the operating mode. The Solenoid is designed to induce magnetic field of 1.8 T over a length of 40 mm in the interaction region with homogeneity of ±0.34%. The solenoid has six concentric cylindrical segments (and two correction segments) of copper foil windings separated by water channels for cooling. The predicted temperature in continuous operation is below 93 °C. The parameters of the design together with simulation results of the electromagnetic cavity field, magnetic field, electron trajectories, and thermal analyses are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Evolution of Short-wavelength Torsional Alfvén Waves

We analyze nonlinear evolution of torsional Alfvén waves in a straight magnetic flux tube filled in with a low- β plasma, and surrounded with a plasma of lower density. Such magnetic tubes model, in particular, a segment of a coronal loop or a polar plume. The wavelength is taken comparable to the tube radius. We perform a numerical simulation of the wave propagation using ideal magnetohydrodynamics. We find that a torsional wave nonlinearly induces three kinds of compressive flows: the parallel flow at the Alfvén speed, which constitutes a bulk plasma motion along the magnetic field, the tube wave, and also transverse flows in the radial direction, associated with sausage fast magnetoacoustic modes. In addition, the nonlinear torsional wave steepens and its propagation speed increases. The latter effect leads to the progressive distortion of the torsional wave front, i.e., nonlinear phase mixing. Because of the intrinsic non-uniformity of the torsional wave amplitude across the tube radius, the nonlinear effects are more pronounced in regions with higher wave amplitudes. They are always absent at the axes of the flux tube. In the case of a linear radial profile of the wave amplitude, the nonlinear effects are localized in an annulus region near the tube boundary. Thus, the parallel compressive flows driven by torsional Alfvén waves in the solar and stellar coronae, are essentially non-uniform in the perpendicular direction. The presence of additional sinks for the wave energy reduces the efficiency of the nonlinear parallel cascade in torsional Alfvén waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated registration of multispectral MR vessel wall images of the carotid artery

Purpose: Atherosclerosis is the primary cause of heart disease and stroke. The detailed assessment of atherosclerosis of the carotid artery requires high resolution imaging of the vessel wall using multiple MR sequences with different contrast weightings. These images allow manual or automated classification of plaque components inside the vessel wall. Automated classification requires all sequences to be in alignment, which is hampered by patient motion. In clinical practice, correction of this motion is performed manually. Previous studies applied automated image registration to correct for motion using only nondeformable transformation models and did not perform a detailed quantitative validation. The purpose of this study is to develop an automated accurate 3D registration method, and to extensively validate this method on a large set of patient data. In addition, the authors quantified patient motion during scanning to investigate the need for correction. Methods: MR imaging studies (1.5T, dedicated carotid surface coil, Philips) from 55 TIA/stroke patients with ipsilateral <70% carotid artery stenosis were randomly selected from a larger cohort. Five MR pulse sequences were acquired around the carotid bifurcation, each containing nine transverse slices: T1-weighted turbo field echo, time of flight, T2-weighted turbo spin-echo, and pre- and postcontrast T1-weighted turbo spin-echo images (T1W TSE). The images were manually segmented by delineating the lumen contour in each vessel wall sequence and were manually aligned by applying throughplane and inplane translations to the images. To find the optimal automatic image registration method, different masks, choice of the fixed image, different types of the mutual information image similarity metric, and transformation models including 3D deformable transformation models, were evaluated. Evaluation of the automatic registration results was performed by comparing the lumen segmentations of the fixed image and moving image after registration. Results: The average required manual translation per image slice was 1.33 mm. Translations were larger as the patient was longer inside the scanner. Manual alignment took 187.5 s per patient resulting in a mean surface distance of 0.271 ± 0.127 mm. After minimal user interaction to generate the mask in the fixed image, the remaining sequences are automatically registered with a computation time of 52.0 s per patient. The optimal registration strategy used a circular mask with a diameter of 10 mm, a 3D B-spline transformation model with a control point spacing of 15 mm, mutual information as image similarity metric, and the precontrast T1W TSE as fixed image. A mean surface distance of 0.288 ± 0.128 mm was obtained with these settings, which is very close to the accuracy of the manual alignment procedure. The exact registration parameters and software were made publicly available. Conclusions: An automated registration method was developed and optimized, only needing two mouse clicks to mark the start and end point of the artery. Validation on a large group of patients showed that automated image registration has similar accuracy as the manual alignment procedure, substantially reducing the amount of user interactions needed, and is multiple times faster. In conclusion, the authors believe that the proposed automated method can replace the current manual procedure, thereby reducing the time to analyze the images.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superionic conduction using ion aggregates

Project objective: Engineer solid polymeric electrolytes with an optimized, self-assembled, ion network that conducts independently of polymer segmental dynamics. The goal of this project is to engineer an optimized, self-assembled ion aggregate network, by which we can incorporate an aggregate assisted, collective, superionic conduction paradigm into polymeric electrolytes. We do not seek to improve conductivity, although this is a likely result of our approach, but to propose systems in which collective motion is the main conduction mechanism. We believe that once such materials are identified, they will quickly become a subject of research in the solid polymer electrolyte community. With this in mind, we pursue three design strategies: increase ion content in PEG single ion conductors, use mixed anions (including divalent ions as crosslinkers), and introduce swelled polyanion/polycation complexes as a potential ion conducting material.

36 MATERIALS SCIENCE↗

Characterizing Mesoscale Cellular Convection in Marine Cold Air Outbreaks With a Machine Learning Approach

Abstract During marine cold‐air outbreaks (MCAOs), when cold polar air moves over warmer ocean, a well‐recognized cloud pattern develops, with open or closed mesoscale cellular convection (MCC) at larger fetch over open water. The Cold‐Air Outbreaks in the Marine Boundary Layer Experiment provided a comprehensive set of ground‐based in situ and remote sensing observations of MCAOs at a coastal location in northern Norway. MCAO periods that unambiguously exhibit open or closed MCC are determined. Individual cells observed with a profiling Ka‐band radar are identified using a watershed segmentation method. Using self‐organizing maps (SOMs), these cells are then objectively classified based on the variability in their vertical structure. The SOM nodes contain some information about the location of the cell transect relative to the center of the MCC. This adds classification noise, requiring numerous cell transects to isolate cell dynamical information. The SOM‐based classification shows that comparatively intense convection occurs only in open MCC. This convection undergoes an apparent lifecycle. Developing cells are associated with stronger updrafts, large spectrum width, larger amounts of liquid water, lower surface precipitation rates, and lower cloud tops than mature and weakening cells. The weakening of these cells is associated with the development of precipitation‐induced cold pools. The SOM classification also reveals less intense convection, with a similar lifecycle. More stratiform vertical cloud structures with weak vertical motions are common during closed MCC periods and are separated into precipitating and non‐precipitating stratiform cores. Convection is observed only occasionally in the closed MCC environment.

Meteorology & Atmospheric Sciences↗

Side chain length affects backbone dynamics in poly(3-alkylthiophene)s

Charge transport in conjugated polymers may be governed not only by the static microstructure but also fluctuations of backbone segments. Using molecular dynamics simulations, we predict the role of side chains in the backbone dynamics for regiorandom poly(3-alkylthiophene-2,5-diyl)s (P3ATs). Here, we show that the backbone of poly(3-dodecylthiophene-2-5-diyl) (P3DDT) moves faster than that of poly(3-hexylthiophene-2,5-diyl) (P3HT) as a result of the faster motion of the longer side chains. To verify our predictions, we investigated the structures and dynamics of regiorandom P3ATs with neutron scattering and solid state NMR. Measurements of spin-lattice relaxations (T1) using NMR support our prediction of faster motion for side chain atoms that are farther away from the backbone. Using small-angle neutron scattering (SANS), we confirmed that regiorandom P3ATs are amorphous at about 300K, although microphase separation between the side chains and backbones is apparent. Furthermore, Quasi-elastic neutron scattering (QENS) reveals that thiophene backbone motion is enhanced as the side chain length increases from hexyl to dodecyl. The faster motion of longer side chains leads to faster backbone dynamics, which in turn may affect charge transport for conjugated polymers.

36 MATERIALS SCIENCE↗

Coupling and Decoupling between Stickers and Backbones in Associating Polymers with Terminally Functionalized Side Chains

Associating polymers have recently attracted tremendous attention as self-healing polymers due to the dynamic reversibility of sticker association–dissociation processes. These sticker dynamics inevitably slow significantly as segmental dynamics decelerate below the glass transition temperature that limits the operational temperatures of associating polymers. Using broadband dielectric spectroscopy on a new set of associating polymers composed side chains of various lengths and terminal carboxylic-acid sticker functionality, we discovered an unexpected decoupling near the glass transition (T g ) between the slower backbone and fast sticker motions. These two motions have distinct activation energies for the motion of the sulfur linkage adjacent to the backbone (~22 to 26 kJ/mol) and the carboxylic acid groups (~5 to 8 kJ/mol). A second decoupling appears in the polymer with the longest side chain length at T g – 20 K, reflecting the dynamics of various carboxylic acid binding configurations. Furthermore, our findings open the door to design associating polymers with the capability of sticker association/dissociation at low temperatures.

36 MATERIALS SCIENCE↗

Hadronization at the AdS wall

We describe hadronization events, using the AdS/CFT Correspondence, which display many of the qualitative features expected in QCD. In particular we study the motion of strings with separating end points in a back-reacted hard wall geometry. The solutions show the development of a linear QCD-like string. The end points oscillate in the absence of string breaking. We introduce string breaking by hand and evolve the new state forward in time to observe the separation of two string segments. A kink associated with this breaking evolves to the end points of the string inducing rho meson production. We explicitly compute the rho meson production at the end point.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pattern ANalytics To Support High-performance Exploitation and Reasoning (PANTHER)

Sandia researchers are developing analytic techniques that efficiently detect patterns in high-volume, noisy, remote sensing and other geospatial data, improving an analysts’ ability to detect possibly off-normal events in complex homeland security, nuclear weapons, and emerging threat environments. High-consequence, national security decisions rely on timely, comprehensive answers to complex questions, yet critical gaps in our approach to these questions remain. PANTHER addresses these gaps through fundamental research on: geospatial-temporal feature extraction via image segmentation and classification; geospatial-temporal graph algorithms and computational geometry; and domain-relevant models of human perception and cognition informing the design of analytic systems. PANTHER’s cross-disciplinary R&D approach uses fundamental science and mathematics to understand how to maximize decision systems through rethinking key aspects of geospatial data analysis. New methods in motion and trajectory analysis support both rapid search for known trajectories as well as rapid clustering and anomaly detection. Thus, the perceptual and visual load on users is reduced by providing pattern analytics with elegant visual cues to spatial and temporal characteristics.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Coupled cluster and dislocation dynamics modeling of microstructure evolution in irradiated materials

We develop here a coupled cluster and dislocation dynamics framework to study the microstructure evolution of irradiated materials. The framework not only accounts for the three dimensional diffusion of radiation-generated clusters, but also their interaction with dislocation networks and the resultant climb motion of discrete dislocations within finite crystals. The framework is solved with a superposition solution scheme, and is applied to investigate the evolution of the irradiation-induced dislocation loops in zirconium (Zr), considering the effects of various bias factors including the diffusion anisotropy difference (DAD) of interstitials and interstitial clusters, the dislocation bias of defects to discrete dislocation segments, and the production bias of defects from the radiation cascade. We find that the DAD is the most critical factor influencing the kinetics of the loop evolution in Zr, while the recombination/interaction of mobile defects can induce a strong spatial dependence of the loop evolution together with the DAD. Here, the method is also adopted to study the evolution of interstitial $\langle$a$\rangle$ and vacancy $\langle$c$\rangle$ dislocation loop ensembles consistent with the microstructure observed during irradiation-induced growth of Zr. Our findings not only reveal the spatial dependence of the size and ellipticity of the dislocation loops, but also suggest a limit on the anisotropy factor of interstitials to reproduce the co-growth of $\langle$a$\rangle$ and $\langle$c$\rangle$ loops in zirconium, in good agreement with experimental observations and other simulation results.

Bias factors↗

GQLink: an implementation of Quantized State Systems (QSS) methods in Geant4

Simulations in high energy physics (HEP) often require the numerical solution of ordinary differential equations (ODE) to determine the trajectories of charged particles in a magnetic field when particles move throughout detector volumes. Each crossing of a volume interrupts the underlying numerical method that solves the equations of motion, triggering iterative algorithms to estimate the intersection point within a given accuracy. The computational cost of this procedure can grow significantly depending on the application at hand. Quantized State System (QSS) is a recent family of discrete-event driven numerical methods exhibiting attractive features for this type of problems, such as native dense output (sequences of polynomial segments updated only by accuracy-driven events) and lightweight detection and handling of volume crossings. In this work we present GQLink, a proof-of-concept integration of QSS with the Geant4 simulation toolkit which stands as an interface for co-simulation that orchestrates robustly and transparently the interaction between the QSS simulation engine and aspects such as geometry definition and physics processes controlled by Geant4. In conclusion, we validate the accuracy and study the performance of the method in simple geometries (subject to intense volume crossing activity) and then in a realistic HEP application using a full CMS detector configuration.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-172: A Quantitative Assessment of Lung Tumor Motion Using 4DCT Imaging Under Conditions of Controlled Breathing in the Management of Non-Small Cell Lung Cancer (NSCLC) Using Stereotactic Body Radiation Therapy (SBRT)

Purpose: To study breathing related tumor motion amplitudes by lung lobe location under controlled breathing conditions used in Stereotactic Body Radiation Therapy (SBRT) for NSCLC. Methods: Sixty-five NSCLC SBRT patients since 2009 were investigated. Patients were categorized based on tumor anatomic location (RUL-17, RML-7, RLL-18, LUL-14, LLL-9). A 16-slice CT scanner [GE RT16 Pro] along with Varian Realtime Position Management (RPM) software was used to acquire the 4DCT data set using 1.25 mm slice width. Images were binned in 10 phases, T00 being at maximum inspiration ' T50 at maximum expiration phase. Tumor volume was segmented in T50 using the CT-lung window and its displacement were measured from phase to phase in all three axes; superiorinferior, anterior-posterior ' medial-lateral at the centroid level of the tumor. Results: The median tumor movement in each lobe was as follows: RUL= 3.8±2.0 mm (mean ITV: 9.5 cm{sup 3}), RML= 4.7±2.8 mm (mean ITV: 9.2 cm{sup 3}), RLL=6.6±2.6 mm (mean ITV: 12.3 cm{sup 3}), LUL=3.8±2.4 mm (mean ITV: 18.5 cm{sup 3}), ' LLL=4.7±2.5 mm (mean ITV: 11.9 cm{sup 3}). The median respiratory cycle for all patients was found to be 3.81 ± 1.08 seconds [minimum 2.50 seconds, maximum 7.07 seconds]. The tumor mobility incorporating breathing cycle was RUL = 0.95±0.49 mm/s, RML = 1.35±0.62 mm/s, RLL = 1.83±0.71 mm/s, LUL = 0.98 ±0.50 mm/s, and LLL = 1.15 ±0.53 mm/s. Conclusion: Our results show that tumor displacement is location dependent. The range of motion and mobility increases as the location of the tumor nears the diaphragm. Under abdominal compression, the magnitude of tumor motion is reduced by as much as a factor of 2 in comparison to reported tumor magnitudes under conventional free breathing conditions. This study demonstrates the utility of abdominal compression in reducing the tumor motion leading to reduced ITV and planning tumor volumes (PTV)

60 APPLIED LIFE SCIENCES↗

Active Breathing Control in Combination With Ultrasound Imaging: A Feasibility Study of Image Guidance in Stereotactic Body Radiation Therapy of Liver Lesions

Purpose: Accurate tumor positioning in stereotactic body radiation therapy (SBRT) of liver lesions is often hampered by motion and setup errors. We combined 3-dimensional ultrasound imaging (3DUS) and active breathing control (ABC) as an image guidance tool. Methods and Materials: We tested 3DUS image guidance in the SBRT treatment of liver lesions for 11 patients with 88 treatment fractions. In 5 patients, 3DUS imaging was combined with ABC. The uncertainties of US scanning and US image segmentation in liver lesions were determined with and without ABC. Results: In free breathing, the intraobserver variations were 1.4 mm in left-right (L-R), 1.6 mm in superior-inferior (S-I), and 1.3 mm anterior-posterior (A-P). and the interobserver variations were 1.6 mm (L-R), 2.8 mm (S-I), and 1.2 mm (A-P). The combined uncertainty of US scanning and matching (inter- and intraobserver) was 4 mm (1 SD). The combined uncertainty when ABC was used reduced by 1.7 mm in the S-I direction. For the L-R and A-P directions, no significant difference was observed. Conclusion: 3DUS imaging for IGRT of liver lesions is feasible, although using anatomic surrogates in the close vicinity of the lesion may be needed. ABC-based breath-hold in midventilation during 3DUS imaging can reduce the uncertainty of US-based 3D table shift correction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D printer generated thorax phantom with mobile tumor for radiation dosimetry

This article describes the design, construction, and properties of an anthropomorphic thorax phantom with a moving surrogate tumor. This novel phantom permits detection of dose both inside and outside a moving tumor and within the substitute lung tissue material. A 3D printer generated the thorax shell composed of a chest wall, spinal column, and posterior regions of the phantom. Images of a computed tomography scan of the thorax from a patient with lung cancer provided the template for the 3D printing. The plastic phantom is segmented into two materials representing the muscle and bones, and its geometry closely matches a patient. A surrogate spherical plastic tumor controlled by a 3D linear stage simulates a lung tumor’s trajectory during normal breathing. Sawdust emulates the lung tissue in terms of average and distribution in Hounsfield numbers. The sawdust also provides a forgiving medium that permits tumor motion and sandwiching of radiochromic film inside the mobile surrogate plastic tumor for dosimetry. A custom cork casing shields the film and tumor and eliminates film bending during extended scans. The phantom, lung tissue surrogate, and radiochromic film are exposed to a seven field plan based on an ECLIPSE plan for 6 MV photons from a Trilogy machine delivering 230 cGy to the isocenter. The dose collected in a sagittal plane is compared to the calculated plan. Gamma analysis finds 8.8% and 5.5% gamma failure rates for measurements of large amplitude trajectory and static measurements relative to the large amplitude plan, respectively. These particular gamma analysis results were achieved using parameters of 3% dose and 3 mm, for regions receiving doses >150 cGy. The plan assumes a stationary detection grid unlike the moving radiochromic film and tissues. This difference was experimentally observed and motivated calculated dose distributions that incorporated the phase of the tumor periodic motion. These calculations modestly improve agreement between the measured and intended doses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate Accumulation of Dose for Improved Understanding of Radiation Effects in Normal Tissue

The actual distribution of radiation dose accumulated in normal tissues over the complete course of radiation therapy is, in general, poorly quantified. Differences in the patient anatomy between planning and treatment can occur gradually (e.g., tumor regression, resolution of edema) or relatively rapidly (e.g., bladder filling, breathing motion) and these undermine the accuracy of the planned dose distribution. Current efforts to maximize the therapeutic ratio require models that relate the true accumulated dose to clinical outcome. The needed accuracy can only be achieved through the development of robust methods that track the accumulation of dose within the various tissues in the body. Specific needs include the development of segmentation methods, tissue-mapping algorithms, uncertainty estimation, optimal schedules for image-based monitoring, and the development of informatics tools to support subsequent analysis. These developments will not only improve radiation outcomes modeling but will address the technical demands of the adaptive radiotherapy paradigm. The next 5 years need to see academia and industry bring these tools into the hands of the clinician and the clinical scientist.

62 RADIOLOGY AND NUCLEAR MEDICINE↗