Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiplexing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Use of a Multiplexed Photonic Doppler Velocimetry (MPDV) System to Study Plastic Deformation of Metallic Steel Plates in High Velocity Impact

High-velocity impact experiments with a gas gun pose unique challenges, in terms of experimental setup and computational simulation, since the projectile-target interaction creates extreme pressure and temperature within few micro seconds. The objective of this study is to accurately measure the plastic deformation of plates under projectile impact that does not lead to full penetration. In this work, free surface velocities at the back side of target plates are measured using the newly developed Multiplexed Photonic Doppler Velocimetry (MPDV) system, which is an interferometric fiber-optic technique which can measure velocity from the Doppler shift of the light reflected from the moving back surface of the target. The MPDV system allows measurements of velocity from different locations on the target plate using multiple optical fiber probes oriented in specific directions and patterns. Data are reduced using a Fast Fourier transformation (FFT) technique to obtain the free surface velocity profiles. These velocity profiles can present insights into the dynamic behavior of impacted materials under shock loading conditions.

MPDV, multiplexing, high-velocity impact, velocime↗

Readout of X-ray Pulses from a Single-pixel TES Microcalorimeter with Microwave Multiplexer Based on SQUIDs Directly Coupled to Resonators

We have first demonstrated the cooperation between an X-ray TES and a directly coupled microwave SQUID multiplexer (D-coup. MW-Mux) in which SQUIDs are directly coupled to resonators. Using D-coup. MW-Mux, we successfully detected the X-ray pulses from a single-pixel TES and evaluated the energy resolution of 11.8 eV FWHM at 5.9 keV. We found this preliminary energy resolution is attributed to non-optimum bias point of the present TES, which can be improved by the future reduction of readout noise.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An antibody-free platform for multiplexed, sensitive quantification of protein biomarkers in complex biomatrices

Sensitive, multiplexed protein quantification remains challenging despite recent advancements in LC-MS assays for targeted protein biomarker quantification. High-sensitivity protein biomarker measurements usually require immuno-affinity enrichment of target protein; a process which is highly dependent on capture reagent and limited in capability to measure multiple analytes. Herein, we report a novel antibody-free platform, which measures multiple biomarkers from complex matrices employing a strategically optimized solid-phase extraction cleanup and orthogonal multidimensional LC-MS. Eight human protein biomarkers with different specifications were spiked into canine plasma as a model investigation system. The developed strategy achieved the desired sensitivity, robustness, and throughput via the following steps: (1) post digestion mixed-mode cation exchange-reverse phase SPE enrichment cleaned up the sample initially; (2) rapid, high-pH peptide fractionation further eliminated background components efficiently while selectively enriched signature peptides (SP) to provide sufficient sensitivity for multiple targets; and (3) trapping-micro-LC-MS analysis delivered high sensitivity comparable to a nano-LC-MS method but with much better robustness and throughput for the final analysis. Compared with a conventional LC-MS assay with direct protein digestion and limited clean-up, analysis with this antibody-free platform improved the LLOQ by 1–2 orders of magnitude for the eight protein biomarkers, reaching as low as 5 ng/mL in plasma, with feasible robustness and throughput. In conclusion, this platform was applied for the quantification of biomarkers of respiratory conditions in patients with various lung diseases, demonstrating real-world applicability.

59 BASIC BIOLOGICAL SCIENCES↗

An automated multiplexed turbidometric and data collection system for measuring growth kinetics of anaerobes dependent on gaseous substrates

Standard methods of monitoring the growth kinetics of anaerobic microorganisms are generally impractical when there is a protracted or indeterminate period of active growth, and when high numbers of samples or replications are required. As part of our studies of the adaptive evolution of a simple anaerobic syntrophic mutualism, requiring the characterization of many isolates and alternative syntrophic pairings, here we developed a multiplexed growth monitoring system using a combination of commercially available electronics and custom designed circuitry and materials. This system automatically monitors up to 64 sealed, and as needed pressurized, culture tubes and reports the growth data in real-time through integration with a customized relational database. The utility of this system was demonstrated by resolving minor differences in growth kinetics associated with the adaptive evolution of a simple microbial community comprised of a sulfate reducing bacterium, Desulfovibrio vulgaris, grown in syntrophic association with Methanococcus maripaludis, a hydrogenotrophic methanogen.

59 BASIC BIOLOGICAL SCIENCES↗

Poly(dimethylsiloxane) microchip-based immunoassay with multiple reaction zones: Toward on-chip multiplex detection platform

In this work, a poly(dimethylsiloxane) (PDMS) microchip-based immuno-sensing platform with integrated pneumatic micro valves is described. The microchip was fabricated with multiple layer soft lithography technology. By controlling the activation status of corresponding valves, reagent flows in the microchannel network can be well manipulated so that immuno-reactions only take place at designated reaction zones (DRZs). Four DRZs are included in the prototype microchip. Since these DRZs are all isolated from each other by micro valves, cross contamination is prevented. Using the inner surface of the all-PDMS microchannel as immunoassay substrate, on-chip sandwich format solid phase immunoassay was performed to demonstrate the feasibility of this immuno-sensing platform. Mouse IgG and fluorescein isothiocyanate (FITC) were used as the model analyte and the signal reporter respectively. Only 10 ul sample is needed for the assay and low detection limit of 5 ng/ml (≈33 pM) was achieved though low-cost polyclonal antibodies were used in our experiment for feasibility study only. The encouraging results from mouse IgG immunoassay proved the feasibility of our microchip design. With slight modification of the assay protocol, the same chip design can be used for multi-target detection and can provide a simple, cost-effective and integrated microchip solution for multiplex immunoassay applications.

60 APPLIED LIFE SCIENCES↗

Multiplex Navigation of Global Regulatory Networks (MINR) in yeast for Improved Ethanol Tolerance and Production

Multiplex navigation of global regulatory networks (MINR) is an approach for combinatorially reprogramming gene expression to manipulate complex phenotypes. We designed, constructed, and mapped MINR libraries containing 43,020 specific mutations in 25 regulatory genes expected to perturb the yeast regulatory network. We selected growth competition experiments for library mutants conferring increased ethanol and/or glucose tolerance. We identified specific mutants that not only possessed improved ethanol and/or glucose tolerance but also produced ethanol at concentrations up to 2-fold higher than those produced by the wild-type strain. We further determined that mutations increasing ethanol tolerance were transferable to a diploid industrial yeast strain. The facile construction and mapping of 43,020 designer regulatory mutations provide a roadmap for how to access and engineer complex phenotypes in future synthetic biology and broader efforts.

09 BIOMASS FUELS↗

Wearable Microsensor Array for Multiplexed Heavy Metal Monitoring of Body Fluids

A flexible and wearable microsensor array is described for simultaneous multiplexed monitoring of heavy metals in human body fluids. Zn, Cd, Pb, Cu, and Hg ions are chosen as target analytes for detection via electrochemical square wave anodic stripping voltammetry (SWASV) on Au and Bi microelectrodes. The oxidation peaks of these metals are calibrated and compensated by incorporating a skin temperature sensor. High selectivity, repeatability, and flexibility of the sensor arrays are presented. Human sweat and urine samples are collected for heavy metal analysis, and measured results from the microsensors are validated through inductively coupled plasma mass spectrometry (ICP-MS). Real-time on-body evaluation of heavy metal (e.g., zinc and copper) levels in sweat of human subjects by cycling is performed to examine the change in concentrations with time. Finally, this platform is anticipated to provide insightful information about an individual's health state such as heavy metal exposure and aid the related clinical investigations.

47 OTHER INSTRUMENTATION↗

Flexible, foldable, actively multiplexed, high-density electrode array for mapping brain activity in vivo

Arrays of electrodes for recording and stimulating the brain are used throughout clinical medicine and basic neuroscience research, yet are unable to sample large areas of the brain while maintaining high spatial resolution because of the need to individually wire each passive sensor at the electrode-tissue interface. To overcome this constraint, we developed new devices that integrate ultrathin and flexible silicon nanomembrane transistors into the electrode array, enabling new dense arrays of thousands of amplified and multiplexed sensors that are connected using fewer wires. We used this system to record spatial properties of cat brain activity in vivo, including sleep spindles, single-trial visual evoked responses and electrographic seizures. We found that seizures may manifest as recurrent spiral waves that propagate in the neocortex. As a result, the developments reported here herald a new generation of diagnostic and therapeutic brain-machine interface devices.

high spatial resolution↗

Multiplexed CRISPR-Cas9-Based Genome Editing of Rhodosporidium toruloides

Microbial production of biofuels and bioproducts offers a sustainable and economic alternative to petroleum-based fuels and chemicals. The basidiomycete yeast Rhodosporidium toruloides is a promising platform organism for generating bioproducts due to its ability to consume a broad spectrum of carbon sources (including those derived from lignocellulosic biomass) and to naturally accumulate high levels of lipids and carotenoids, two biosynthetic pathways that can be leveraged to produce a wide range of bioproducts. While R. toruloides has great potential, it has a more limited set of tools for genetic engineering relative to more advanced yeast platform organisms such as Yarrowia lipolytica and Saccharomyces cerevisiae. Significant advancements in the past few years have bolstered R. toruloides ’ engineering capacity. Here we expand this capacity by demonstrating the first use of CRISPR-Cas9-based gene disruption in R. toruloides . Transforming a Cas9 expression cassette harboring nourseothricin resistance and selecting transformants on this antibiotic resulted in strains of R. toruloides exhibiting successful targeted disruption of the native URA3 gene. While editing efficiencies were initially low (0.002%), optimization of the cassette increased efficiencies 364-fold (to 0.6%). Applying these optimized design conditions enabled disruption of another native gene involved in carotenoid biosynthesis, CAR2 , with much greater success; editing efficiencies of CAR2 deletion reached roughly 50%. Finally, we demonstrated efficient multiplexed genome editing by disrupting both CAR2 and URA3 in a single transformation. Altogether, our results provide a framework for applying CRISPR-Cas9 to R. toruloides that will facilitate rapid and high-throughput genome engineering in this industrially relevant organism.

59 BASIC BIOLOGICAL SCIENCES↗

Simulate_PCR for amplicon prediction and annotation from multiplex, degenerate primers and probes

Background: Pairing up primers to amplify desired targets and avoid undesired cross reactions can be a combinatorial challenge. Effective prediction of specificity and inclusivity from multiplexed primers and TaqMan®/ Luminex® probes is a critical step in PCR design. Results: Code is described to identify all primer and probe combinations from a list of unpaired, unordered candidates that should produce a product. It predicts and extracts all amplicon sequences in a large sequence database from a list of primers and probes, allowing degenerate bases and user-specified levels of primer-target mismatch tolerance. Amplicons hit by TaqMan®/Luminex® probes are indicated, and products may be annotated with gene information from NCBI. Fragment length distributions are calculated to predict electrophoretic gel banding patterns. Conclusions: Simulate_PCR is the only freely available software that can be run from the command line for high throughput applications which can calculate all products from large lists of primers and probes compared to a large sequence database such as nt. It requires no prior knowledge of how primers should be paired. Degenerate bases are allowed and entire amplicon sequences are extracted and annotated with gene information. Examples are provided for sets of TaqMan®/Luminex® PCR signatures predicted to amplify all HIV-1 genomes, all Coronaviridae genomes, and a group of antibiotic resistance genes. The software is a command line perl script freely available as open source.

59 BASIC BIOLOGICAL SCIENCES↗

Multiplexing and Demultiplexing Signals for Radiography Application Using the Discrete Fourier Transform

Our goal is to develop an X-ray phase-contrast imaging system that can provide excellent soft tissue contrast of phase, attenuation, and small-angle scatter. We propose to replace the common system of G0, G1, and G2 gradings with a biprism array to replace the G1 grading and introduce a novel X-ray tube designed to replace the motion of the phase stepping grading G2. The proposed X-ray tube uses temporal multiplexing to provide simultaneous virtual “electronic phase stepping.” In this work the discrete Fourier transform is used to separate from the composite measurement individual X-ray phase contrast measurements sampled at different frequencies. The method performs a discrete Fourier transform of a composite refence sequence to obtain using the frequency amplitudes calibration factors needed to extract the X-ray phase contrast measurement amplitudes from the composite image. The composite reference sequence is the sum of the individual sequences, at different frequencies, with amplitudes of one. The method takes the discrete Fourier transform of this composite reference sequence; whereby, the amplitude of each frequency component is compared with the total sum of its stand-alone sequence amplitude. A calibration factor is determined so that the amplitude of this composite reference frequency times the calibration factor must equal the total sum of the sequence amplitude—the zero-frequency amplitude of the discrete Fourier transform of its stand-alone sequence. To demultiplex the composite measured signal these calibration factors are multiplied by the amplitudes of the frequency components of the discrete Fourier transform of the composite X-phase-contrast measurement to obtain the amplitude of each frequency encoded measurement. Using these calibration factors, we demonstrate with the discrete Fourier transform in Mathematica the extraction of individual images from a composite image that one would expect obtaining from our proposed new X-ray phase contrast imaging system. We then demonstrate as an example how using images from X-ray phase contrast data one can calculate phase, attenuation and the dark field images using grading phase step data supplied to use from Microworks, GmbH in Karlsruhe, Germany.

42 ENGINEERING↗

PARA: A New Platform for the Rapid Assembly of gRNA Arrays for Multiplexed CRISPR Technologies

Multiplexed CRISPR technologies have great potential for pathway engineering and genome editing. However, their applications are constrained by complex, laborious and time-consuming cloning steps. In this research, we developed a novel method, PARA, which allows for the one-step assembly of multiple guide RNAs (gRNAs) into a CRISPR vector with up to 18 gRNAs. Here, we demonstrate that PARA is capable of the efficient assembly of transfer RNA/Csy4/ribozyme-based gRNA arrays. To aid in this process and to streamline vector construction, we developed a user-friendly PARAweb tool for designing PCR primers and component DNA parts and simulating assembled gRNA arrays and vector sequences.

59 BASIC BIOLOGICAL SCIENCES↗