Search NASA⌕ Search

SEARCH · Search NASA

Results for “NANOSECOND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Implementation of high-speed data acquisition at DIII-D

Research at the DIII-D National Fusion Facility in San Diego focuses on short pulse plasma discharges that specialize on various shaping profiles. High-speed data collection is a critical component for the operation of many of DIII-D’s diagnostics and is fundamental for capturing high-resolution data used in experimental data analysis. Differing techniques enable the plasma control system (PCS) to perform complex real-time feedback control on microsecond time scales. This work presents a comprehensive overview of data acquisition, focusing on the hardware and software used in reliable data acquisition at DIII-D. The robust nature of the data acquisition system allows for various techniques to coexist seamlessly. However, as modern systems capable of nanosecond resolution become more common, existing architectures will need to be modified. Here, by addressing the key challenges of high-speed data acquisition, DIII-D is able to provide real-time data used in plasma operation and has the ability to acquire high fidelity data needed for future experimental fusion reactors, such as ITER.

Control↗

Advances in mapping of x-ray emission from NIF hohlraums

A newly available ns-gated laser-entrance-hole (GLEH) imager in the National Ignition Facility provides a routine, non-perturbative measurement of hohlraum x-ray emission from inner and outer laser beam deposition regions. The GLEH records the x-ray flux integrated over complex interactions of various part of hohlraum plasma that evolves on a sub-nanosecond time scale. In using these images to unravel hohlraum physics, the first step is to pinpoint the origin inside the hohlraum of the observed x-ray image features. By mapping the hohlraum emission to the GLEH images using high-resolution simulations, one can interpret the GLEH images and gain insight into the hohlraum dynamics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Coating adhesion of a chromate-containing epoxy primer on Al2024-T3 surface processed by laser-interference

In this work, the coating adhesion test results are presented for a primer that was coated on laser-interference structured surfaces of as-received Al2024-T3 specimens, i.e., without employing any polishing, cleaning, or any other surface alteration techniques. All of the laser-interference processing was performed by splitting the primary beam of a Q-switched Nd:YAG pulsed nanosecond laser into two beams and focused them to the same spot. The specimens were spray painted with a chromate-containing epoxy primer, CA7233, compliant to MIL-PRF-23377 Type I Class C2 specification. The adhesion of primer on Al surface with different treatments was assessed using the ASTM D3359 X-cut and cross-hatch tests. It was found that the laser processed specimens meet the performance requirements in the coating adhesion specifications by having a higher or identical ranking for coating adhesion specimens than those prepared with current state-of-the-art chemical conversion or sulfuric acid anodizing. The rastering with either 4 mm/s or 6 mm/s with a laser fluence of 1.78 J/cm2 is recommended to attain acceptable coating adhesion, even higher than that with the anodizing surface treatment.These results indicate that laser-interference shows significant potential as a non-chemical surface preparation technique for these coatings.

36 MATERIALS SCIENCE↗

Spectroscopy and dynamics of the v = 1 levels derived from the OH(D) stretching modes in the I‾∙HDO complex using CW and time-resolved, resonant two-photon infrared excitation of the cryogenically cooled ions

The vibrational energy levels of the two isotopomers adopted by the I‾∙HDO ion-molecule complex occur such that the OH(D) stretching fundamentals span its dissociation energy, thus enabling a spectroscopic investigation of the dynamics displayed by a system prepared in the vicinity of the dissociation threshold. This regime is explored using infrared photoexcitation of the mass-selected complexes cooled in a cryogenic radiofrequency (Paul) ion trap. Survey spectra are obtained at modest resolution using two-color, IR-IR photodissociation with nanosecond lasers to establish the level structure and unimolecular decay dynamics of the v = 1 and 2 levels of the bound OH(D) oscillator. The v = 1 levels are prepared by fixed frequency excitation in the trap and the absorption spectra arising from this excited state are probed by photofragmentation of the complex with a second pulsed IR laser after a variable delay time (0 to 20 ms). The transitions to levels above the dissociation threshold for I‾ + HDO formation are observed to be sharp (~5 cm -1 FWHM). At low pressure, the bound OD (v = 1) population relaxes very slowly (~3 ms), consistent with resonant fluorescence in the IR. The collisional quenching rate constants of this level by the He buffer gas were estimated to be on the order 3 x 10 -12 cm 3 /s based on a crude Stern-Volmer analysis. Here, the rotational fine structure and linewidths (≲0.01 cm -1 FWHM) arising from transitions of the non-bonded OH stretch fundamental of the OD-bound isotopomer that lies just above the dissociation energy are determined using single photon photodissociation by excitation of the 10 K ions with a single-frequency, CW IR laser in the ion trap.

Cryogenic ion infrared spectroscopy↗

15 years of spin-echo spectroscopy at SNS-NSE: Looking back and looking forward

High-resolution neutron spin echo (NSE) spectroscopy offers unique insights into the mobility of molecular (sub)structures excited by thermal fluctuations (i.e., Brownian motion) of “soft matter” as polymers in solution and in the melt, in biological matter (e.g., protein motions), membranes, and glasses. The ability to tag substructures using H, D contrast variation to resolve the relevant timescales of dynamics on selected molecular items in liquids, soft matter, and melts is a significant advantage of NSE. Also slow magnetic fluctuations on molecular length scales in the range of nanoseconds, e.g., in spin glasses or topological spin structures, can be accessed. This paper reviews the highlights and peculiarities of the SNS-NSE, based at the pulsed neutron source SNS, during its first 1.5 decades of operation. An outlook and perspectives of research in the domain of high-resolution spectroscopy is given.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation-induced negative optical nonlinearities in fused silica, sapphire, and borosilicate glass

Here, negative nonlinear absorption is reported in neutron- and gamma-irradiated high-OH content fused silica, low-OH content fused silica, sapphire, borosilicate glass, and radiation-resistant borosilicate glass irradiated to total neutron fluences of 3.4 × 10 16 n ∙ cm –2 (42 Mrad γ), 1.7 × 10 17 n ∙ cm –2 (211 Mrad γ), and 3.6 × 10 17 n ∙ cm –2 (433 Mrad γ). Nonlinear absorption coefficients were measured via Z-scan and are on the order of – (10 –14 –10 –10 ) m∙W –1 . The Z-scan also reveals a negative nonlinear index of refraction in neutron- and gamma-irradiated radiation-resistant borosilicate glass on the order of –10 –19 m 2 ∙ W –1 . Thermal annealing at temperatures up to 800 °C is shown to restore these nonlinearities to their positive unirradiated values in all four materials. All Z-scan measurements were performed at 532 nm with a nanosecond pulsed laser. The occurrence of negative nonlinearities may be attributed to the presence of metallic impurities and the resulting saturable absorption. A limited effect of photobleaching is observed in measurements and is quantified in multiple Z-scans.

36 MATERIALS SCIENCE↗

Microstructural evolution of rapidly solidified hypoeutectic Al 10Cu alloy during non-isothermal annealing transients induced by nano-second laser pulses

The evolution of characteristic nonequilibrium features presenting in morphologically distinct regions of rapid solidification (RS) microstructures in a hypoeutectic Al—10Cu (atomic %) in response to non-isothermal annealing transients has been studied by transmission electron microscopy (TEM). The capabilities of the Movie-Mode Dynamic TEM (MM-DTEM) instrument were used to expose select regions of the RS microstructure to sequences of rapid heating and cooling transients induced by nanosecond laser pulses while permitting in-situ observation. Partial melting, microstructural scale coarsening, morphological changes of the nonequilibrium features in the multi-phase RS microstructure, and solid-state phase transformation were observed. Heterogeneous nucleation of nanoscale θ-Al 2 Cu phase involved metastable supersaturated α-Al and the θ'-Al 2 Cu phases, establishing different sets of orientation relationships for the stable θ-Al 2 Cu and α-Al phases. Replacement of banded morphology grains that formed under conditions driven farthest from equilibrium by an equiaxed nanocrystalline structure comprised of α-Al phase, the primary solidification product, and an intergranular network of Al 2 Cu crystals has been attributed to local remelting. Here the experimental approach explored, permitted discovery of mechanistic details of location-specific transformation pathways activated in the multi-phase RS microstructure of hypoeutectic Al—Cu during subsequent nonisothermal transients.

36 MATERIALS SCIENCE↗

Directional amorphization of covalently-bonded solids: A generalized deformation mechanism in extreme loading

Shock compression subjects materials to a unique regime of high quasi-hydrostatic pressure and coupled shear stresses for durations on the order of 1–10 nanoseconds for laser-driven loading of samples. There is, additionally, an attendant temperature increase due to the shock and the mechanisms of plastic deformation in metals whereby dislocations, twins, and phase transitions nucleate and propagate at velocities near the sound speed. Covalently bonded materials have, by virtue of the directionality of their bonds, great difficulty in responding by conventional plastic deformation to this extreme regime of shock compression. Here, we propose that the shear from shock compression induces amorphization, as observed in Si, Ge, B4C, SiC, and olivine ((Mg, Fe) 2 SO 4 ) and that this is a general deformation mechanism in a broad class of covalently bonded materials. The crystalline structure transforms to amorphous along regions of maximum shear stress, forming nanoscale bands, and thereby relaxing the shear component of the imposed shock stress. This process is usually preceded by the emission and propagation of a critical concentration of dislocations.

36 MATERIALS SCIENCE↗

Assessing the vulnerability of solar inverters to EMPs: Port testing, PCI modeling, and protection strategies

Renewable energy sources are becoming an ever-larger contributor to the power grid. These renewable energy sources depend upon the power electronic devices, specifically inverters, being essential for connecting Photovoltaic (PV) generation to the grid. However, the Electromagnetic Pulses (EMPs) caused by the high-altitude nuclear explosions can generate fast broad-band pulses with nanosecond rise time, potentially causing damage or destruction to electronic components. To assess the vulnerability of PV inverters to high-altitude EMPs, the port testing and Pulsed Current Injection (PCI) modeling schemes are proposed based on the port impedance analysis. Wide-band frequency measurements are achieved by fusing impedance results from three vector network analyzers. Then, a PCI model is used to simulate the induced response to EMP, with two typical immunity levels of EC5 and EC8 tested. Here, the experiment successfully excites the induced voltage and current under EMP, where the voltage and current can reach 1500V/40A and 8000V/150Aunder EC5 andEC8, respectively. The port vulnerability analysis results demonstrate that only some ports can survive under EC5. To defend against the impact of EMP, three protection strategies are discussed.

42 ENGINEERING↗

In-situ L-TEM observations of dynamics of nanometric skyrmions and antiskyrmions

Nanometer-scale magnetic skyrmions and antiskyrmions exhibit unique dynamical behaviors in response to external stimuli, which are critical for their applications in low-power-consumption spintronic devices. This review discusses recent advancements in in-situ Lorentz transmission electron microscopy (L-TEM) observations of skyrmion and antiskyrmion dynamics, and demonstrates the manipulation and evolution of these textures in various magnetic materials under electric, magnetic, and thermal stimuli. Specifically, the motion tracking of single skyrmions and their clusters, and the deformation and transformation of skyrmions has been demonstrated in chiral helimagnets FeGe, Co 9 Zn 9 Mn 2 , and Co 10 Zn 10 with precise application of electric currents. Skyrmions can undergo dynamic transitions in current-driven skyrmion motions, from pinned states to linear flows, and even exhibit deformation into elliptical shapes, underscoring their topological robustness and dynamic flexibility. In addition, the manipulation of single antiskyrmions and antiskyrmion-lattice phases in (Fe 0.63 Ni 0.3 Pd 0.07 ) 3 P with S 4 symmetry is discussed, highlighting their high mobility and unique sliding capabilities along stripe domains at room temperature, facilitated by nanosecond pulsed electric currents. Finally, the temperature gradient-driven motion and topological transformation of elliptical skyrmions and antiskyrmions in this same material are investigated. In conclusion, the comprehensive insights gained from the L-TEM imaging technique are pivotal in advancing the design and functionality of next-generation skyrmion/antiskyrmion-based spintronic devices.

(Anti)skyrmion↗

Development of digital electronics for the search of SHE nuclei using GARIS-II/III at RIKEN

This work describes the implementation of a digital data acquisition system for the search and study of short-lived isotopes or superheavy elements at the GARIS-III separator at the RIKEN Nishina Center. Here a reduction to 26 ± 0.5 keV in the average value of the Full Width at Half Maximum of the alpha spectrum at 7.133 MeV was achieved, combined with a reduction of the dead time of the overall system to around a few tens of nanoseconds for the detection of very fast decay chains. Moreover, we measured a reduction of the background induced by particles crossing the implantation detector using pulse shape analysis techniques. The detail of the optimization and analysis will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The CeBrA demonstrator for particle-γ coincidence experiments at the FSU Super-Enge Split-Pole Spectrograph

We report on a highly selective experimental setup for particle-γ coincidence experiments at the Super-Enge Split-Pole Spectrograph (SE-SPS) of the John D. Fox Superconducting Linear Accelerator Laboratory at Florida State University (FSU) using fast CeBr scintillators for γ-ray detection. Specifically, we report on the results of characterization tests for the first five CeBr 3 scintillation detectors of the CeBr 3 Array (CeBrA) with respect to energy resolution and timing characteristics. We also present results from the first particle-γ coincidence experiments successfully performed with the CeBrA demonstrator and the FSU SE-SPS. We show that with the new setup, γ-decay branching ratios and particle-γ angular correlations can be measured very selectively using narrow excitation energy gates, which are possible thanks to the excellent particle energy resolution of the SE-SPS. In addition, we highlight that nuclear level lifetimes in the nanoseconds regime can be determined by measuring the time difference between particle detection with the SE-SPS focal-plane scintillator and γ-ray detection with the fast CeBrA detectors. As a result, selective excitation energy gates with the SE-SPS exclude any feeding contributions to these lifetimes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photocathode characterisation for robust PICOSEC Micromegas precise-timing detectors

The PICOSEC Micromegas detector is a precise-timing gaseous detector based on a Cherenkov radiator coupled with a semi-transparent photocathode and a Micromegas amplifying structure, targeting a time resolution of tens of picoseconds for minimum ionising particles. Initial single-pad prototypes have demonstrated a time resolution below σ = 25 ps, prompting ongoing developments to adapt the concept for High Energy Physics applications, where sub-nanosecond precision is essential for event separation, improved track reconstruction and particle identification. The achieved performance is being transferred to robust multi-channel detector modules suitable for large-area detection systems requiring excellent timing precision. To enhance the robustness and stability of the PICOSEC Micromegas detector, research on robust carbon-based photocathodes, including Diamond-Like Carbon (DLC) and Boron Carbide (B 4 C), is pursued. Results from prototypes equipped with DLC and B 4 C photocathodes exhibited a time resolution of σ ≈ 32 ps and σ ≈ 34.5 ps, respectively. Efforts dedicated to improve detector robustness and stability enhance the feasibility of the PICOSEC Micromegas concept for large experiments, ensuring sustained performance while maintaining excellent timing precision.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector↗

Characterization of the optical model of the T2K 3D segmented plastic scintillator detector unit cube

The magnetized near detector (ND280) of the T2K long-baseline neutrino oscillation experiment has been recently upgraded aiming to satisfy the requirement of reducing the systematic uncertainty from measuring the neutrino–nucleus interaction cross section, which is the largest systematic uncertainty in the search for leptonic charge-parity symmetry violation. A key component of the upgrade is SuperFGD, a 3D segmented plastic scintillator detector made of approximately 2,000,000 optically-isolated 1 cm 3 cubes. The SuperFGD cube unit shows promising optical performance, including a high light yield of about 40 photoelectrons (p.e.) per channel, a low cube-to-cube crosstalk rate below 3%, and a sub-nanosecond time resolution of 0.96 ns. By combining tracking and stopping power measurements of final state particles, this novel detector enables precise 3D-imaging of GeV neutrino interactions with reduced systematic uncertainties. A detailed Geant4 based optical simulation of the SuperFGD building block, i.e. a plastic scintillating cube read out by three wavelength shifting fibers, has been developed and validated with the different datasets collected in various beam tests. In this manuscript the description of the optical model as well as the comparison with data are reported.

Neutrino oscillations↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Two-phase accurate multiplexed structured image capture (2pAc-MUSIC)

Multiplexed Structural Image Capture (MUSIC) technique uses modulation of light from a scene prior to imaging to encode the temporal evolution of target into spatial frequency shifts, with each shift corresponding to a unique time and resulting in individual distinct snapshots. Computational-processing of the multiplexed single-shot image can recover the nanosecond-resolution scene evolution. One of the limitations is the loss of spatial resolution of the recovered image due to limitations of the low-pass spatial frequency filtering depth. Here we demonstrated that two images with complementary spatial phases can be used to enhance the spatial resolutions. For this application, 2 Phase Accurate (2pAc)-MUSIC is implemented that a scene is encoded with two complementary phases. The increased spatial information captured reduces the lower frequency noise in the Fourier domain found in single-phase MUSIC. A recovery algorithm combines the 180-degree spatial frequency shifted images into a single scene and applies a spatial filter in the Fourier domain that has a larger depth than previously possible to achieve a scene with increased spatial resolution. The 2pAc-MUSIC can effectively enhance the spatial resolution by removing the overlapping zero-order spatial frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗