Search NASA⌕ Search

SEARCH · Search NASA

Results for “NCSP Integral Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

The conduct of the united states department of energy nuclear criticality safety program hands-on training and education courses - 14621

The United States Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP), funded and managed by the National Nuclear Security Administration (NNSA), offers courses to educate nuclear criticality safety (NCS) engineers, process supervisors, and others, and to provide experimental, hands-on training addressing important characteristics of neutron multiplying systems. This training satisfies the American National Standard Institute/American Nuclear Society (ANSI/ANS)-8.26-2007 requirement for participating in hands-on experiments with fissionable materials and provides awareness and understanding of DOE Orders, Guides and Rules, ANS standards, and hazard identification techniques, as well as control design, implementation, and maintenance in criticality safety evaluations. Since the pilot course was developed in 2011, a variety of courses have been developed for NCS practitioners and process supervisors. Attendees have come from several US and international sites. Through NCSP international collaborations and relationships, students from the Atomic Weapons Establishment (AWE) in the United Kingdom, Atomic Energy of Canada, and the Institute for Radiation Protection and Nuclear Safety in France have participated in these courses in the US. Manager courses are available for process supervisors and operations managers with NCS responsibilities in their daily jobs. Manager courses are taught at Sandia National Laboratory (SNL) and the National Criticality Experiments Research Center (NCERC); they offer a combination of hands-on experiments and classroom discussions. A two-week course is also offered for NCS practitioners, with a week of classroom instruction at Los Alamos National Laboratory (LANL) focused on generation of NCS evaluations, and a week of hands-on training utilizing the critical assemblies at either SNL or NCERC. Cleared students can attend the hands-on training at either SNL or NCERC, and uncleared students can attend at SNL. Courses continue to evolve and continuously improve as important elements of NCS evaluations (e.g., human factors, non-destructive assay (NDA) techniques, process criticality accident lessons-learned, and hand calculation methods) are integrated with criticality safety evaluation exercises. Courses include tours of process operations at SNL, NCERC, and LANL, and interaction with instructors experienced in conducting critical experiments and working in NCS. The NNSA NCSP provides management, funding, and technical direction for these courses and makes them available with no tuition cost to NCS practitioners. This paper provides a status report to the NCS community on the conduct of these courses and how they will likely evolve in the future. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

IER 498: Godiva-IV CAAS benchmark [Slides]

This presentation discusses the benchmark of the IER 498: Godiva-IV criticality accident alarm system (CAAS). It details the goal of the project which is to create a CAAS benchmark capability for Godiva-IV in order to create a shielding benchmark for NCSP software and data, to add geometrically diverse benchmark/benchmarks to the ICSBEP Handbook, to enable more precise measurements at NCERC, and to help assure CAAS performance is as-stated. It also states that work was completed on CED-1 in 2019 and that future work includes the completion of CED-2 in 2020.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity-based Experiment Design Optimization for a Molybdenum Critical Experiment

A lack of intermediate molybdenum benchmarks in the ICSBEP has been identified by LANL, Y-12, and IRSN. This lacking adversely effects criticality safety operations and leaves new differential molybdenum data unvalidated. NCERC is proposing a series of intermediate integral experiments to better the understanding of molybdenum systems. Using MCNP6.2 with the ENDF/B-VIII.0 nuclear data library a single unmoderated and four moderated system designs were identified using a sensitivity optimization method. Each proposed system was found to be at least twice as sensitive to the 95 Mo capture cross section in the URR as the sole existing intermediate molybdenum benchmark in the ISCBEP handbook. The addition of a new molybdenum sensitive intermediate system would improve future nuclear data evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Benchmark Evaluation of one Dimensional Array of HEU Moderated and Reflected by Lucite [Poster]

Two critical experiments with HEU-Lucite were performed using the Planet Universal Critical Assembly Machine at Los Alamos National Laboratory in 2019. HEU foils were interleaved with Lucite in a column stack for moderation and reflection from the square Lucite plates. The evaluation of the experiments is presented. A Monte-Carlo (MCNP6) calculation model was developed for the determination of uncertainties and their effect on the multiplication factor. Experimental uncertainties were found to be low with the overall uncertainty in k eff approximately 240 pcm. The comparison of calculations with experimental data is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status of the International Criticality Safety Benchmark Evaluation Project

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has continued its work generating evaluations of new and historical criticality benchmark experiments since the last update to the nuclear criticality safety community at the 11th International Conference on Nuclear Criticality Safety (ICNC 2019) in Paris, France. Three additional versions of the ICSBEP Handbook have been published since that update, and the Technical Review Group (TRG) held two in-person (in 2019 and 2023) and three virtual (2020 and 2021) meetings to review and approve additional benchmarks. The 2019 edition of the ICSBEP Handbook included five new evaluations with 79 new configurations, the 2020 version of the ICSBEP Handbook contained five new evaluations totaling 76 new configurations, and the 2021 version of the ICSBEP handbook contained five new evaluations with a total of 57 different configurations. The ICSBEP TRG met in October and December 2021, to review benchmarks for potential inclusion in the 2022 ICSBEP Handbook, with seven evaluations receiving provisional approval pending resolution of review group comments. Final comment resolution for some of these evaluations is currently underway and handbook publication should be completed soon. The ICSBEP TRG met again in person in April 2023 to review benchmarks for the 2023 ICSBEP Handbook, provisionally approving 7 new evaluations. The ICSBEP continues to deliver high-quality, peer reviewed evaluations of experiments relevant to the nuclear criticality safety community.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final Design for Thermal/Epithermal eXperiments using High 240 Pu Content Plutonium/Aluminum Zero Power Research Reactor Plates with Polyethylene Moderator (IER 520 Final Design CED-2 Report)

The US Department of Energy Nuclear Criticality Safety Program (NCSP) convened a multinational Thermal Epithermal eXperiments (TEX) meeting in July of 2011 to discuss the data and experimental needs of criticality safety practitioners. The number one and two priority integral experiment data needs were for 239 Pu and 240 Pu, with special emphasis on cross section performance in the intermediate energy range (from 0.625 eV to 100 keV). LLNL measured five critical configurations with LANL for the plutonium test bed (IER-184) and published the experiments as International Criticality Safety Benchmark Evaluation Project evaluation PUMET-MIXED-002. Modeling of the benchmark configurations using ENDF/B-VIII.0 nuclear data showed significant overprediction of reactivity for configurations that had a large percentage of fissions in the intermediate energy regime. This report documents a variation on the TEX plutonium test bed to provide a test of 240 Pu cross sections, with sensitivity of the configuration to 240 Pu radiative capture and fission cross sections a priority for the design.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Resolved resonance region evaluations of n+ 206,207,208 Pb for fast spectrum applications

Resolved resonance region evaluations of the major isotopes of natural lead, 206 Pb, 207 Pb, 208 Pb, have been per formed to support the development of Generation IV reactors. In this study, validation of nuclear data for lead fast reactors was performed with simulations of shielding benchmarks, integral critical benchmarks, and quasi-differential scattering measurements. Sensitivity analyses of these systems showed that elastic scattering reactions above 100 keV were the dominant reactions driving system performance. The resolved resonance regions (RRRs) of the lead isotopes extend past 100 keV, making the RRR an ideal starting point to evaluate lead cross sections. Since the R-matrix requires knowledge of bound, distant, and observed resonances, it was necessary to evaluate from 10 -5 eV up to the respective limit of the RRR. The 208 Pb RRR evaluation was extended to 1.5 MeV in order to obtain resonance parameters used to calculate new elastic scattering angular distributions up to 1.5 MeV. Resonance parameter uncertainties and covariance were generated using the R-matrix code SAMMY. The new RRR parameters show a direct improvement to the scattering kernel below 1.5 MeV which in turn greatly improves fast critical experiments over ENDF/B-VIII.0.

206Pb↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Particle Swarm Optimization Algorithm for Critical Experiment Design

Nuclear criticality experiments are used to validate nuclear cross section data used by simulation software. This is typically achieved by designing a critical system with a high sensitivity to a certain material’s cross section. Once the experiment has been carried out, a high fidelity model of the system is developed into a benchmark. When this benchmark model is simulated by a transport code, some of the difference between the experimental and computational effective neutron multiplication factor can be attributed to inaccurate nuclear data. Nuclear data evaluators then can make adjustments accordingly to improve cross section data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Godiva IV Central Cavity Neutron Environment Characterization with Threshold Neutron Detectors

Godiva IV is a cylindrical fast burst reactor comprised of approximately 65 kg of highly enriched uranium that is operated by Los Alamos National Laboratory and sited at the National Criticality Experiments Research Center at the Nevada National Security Site in Nevada in the United States. Godiva IV is typically operated at delayed critical and in the regime spanning from sub-prompt to super-prompt bursts. Godiva IV is used for sample irradiations, criticality safety demonstrations, dosimetry studies, and for studying super-prompt behavior. In preparation for both an upcoming experiment to reduce uncertainties in the prompt fission spectrum for 235 U using threshold neutron detectors, and for future research using Godiva IV, it was desired to exercise the process of the selection of threshold neutron detectors/activation foils, radiation metrology, and the subsequent adjustment of the neutron spectrum. For this exercise, nine high purity threshold neutron detectors/activation foils were irradiated in a Godiva IV burst. The foils were then analyzed using a high purity germanium detector in the NCERC counting laboratory to determine end of irradiation specific activities for available IRDFF-II reactions. This work summarizes the Godiva IV foil irradiation, radiation metrology results, and adjusted neutron spectrum. The results of this exercise ultimately characterized the neutron environment inside the sample irradiation cavity inside Godiva IV to a higher degree than previously performed, informed decisions for the upcoming larger scale experiment, and will inform future neutron spectrum characterizations at NCERC.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Godiva IV Burst Reproducibility and Diagnostic Testing

Godiva IV is a fast burst critical assembly located at the Nation Criticality Experiment Research Center (NCERC) in the Nevada National Security Site (NNSS). It is constructed of approximately 65 kg of highly enriched uranium (HEU) fuel alloyed with 1.5% molybdenum for strength. The assembly can be operated at delayed critical or can be used to perform super-prompt critical bursts with temperature rises of up to 250 °C. Several projects with the objective of characterizing Go diva IV are ongoing including characterizations of its radiation emission and thermomechanics. One of the characterization projects is a study of the variability in the relative source emission (or fluence in absolute terms) between bursts that are nominally the same size. There is some inherent variation in the number of fissions, or "size" of the burst, even for bursts where the operators perform identical processes. The source of the variation can be attributed to several factors. The largest contributor is the precision with which the operators are able to determine delayed critical (DC). Operators find DC for every burst operation. The impact of being slightly above or below DC can change the super-prompt critical reactivity and therefore the source term. The temperature of the fuel is another factor. Establishing delayed critical prior to performing a burst act as a control of the bulk temperature coefficient of reactivity.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Official Website of the U.S. Department of Energy's Nuclear Criticality Safety Program

The U.S. Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP) mission is to provide sustainable expert leadership, direction, and the technical infrastructure necessary to develop, maintain, and disseminate the essential technical tools, training, and data to support safe, efficient fissionable material operations within the DOE. The NCSP Website site makes a variety of information available to the criticality safety practitioner, including reference materials, training modules and links to related sites. It assists criticality safety personnel to keep abreast of NCSP activities or current developments in criticality safety via a "What’s New" section within the Website. Convenient access to the many useful features of the Website is available via drop-down menus. The Website is also available to non-DOE and international professionals tasked with ensuring safe operations involving fissionable nuclear materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IRSN Work in Support of NCSP: FY2021 and Plan for Future [Slides]

IRSN and NCSP collaboration has been very fruitful. Despite challenges presented by COVID-19, work has been performed regularly and successfully by video conference. This includes monthly basis meeting with LLNL and LANL and specifics meetings with ORNL and SNL when needed. After two years without any IRSN participation to experiments, ISRN is looking forward to fully participating in the three proposed integral experiments scheduled in 2022. IRSN is working on several new projects including TEX-MOX and TEX-low temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast-Spectrum Critical Assemblies with a Pb-HEU Core Surrounded by a Copper Reflector

The Department of Energy invests tens of millions of dollars each year to develop the next generation of nuclear engineering modeling & simulation (M&S) tools. These M&S tools are used to analyze advanced reactor designs and the safety of current nuclear operations. As computers become more powerful, we are able to enhance resolution in our calculations. This improved resolution is taking us to a point where the limitations of simulation capability are in the quality of data, including our ability to quantify the uncertainty and sensitivity of the data. In order to accurately model systems of interest, the industry must improve key nuclear data measurements and our confidence of how well we understand the data. Thus, M&S tools need evaluated and quality-assured experimental data for validation purposes. The International Criticality Safety Benchmark Evaluation Project (ICSBEP) compiles benchmark experiment data in a handbook that can be used by criticality safety engineers to validate computer codes and cross-section libraries at nuclear facilities. Both critical and subcritical experiments are included in the handbook. Figure 1 organizes all the benchmark evaluations that have been performed by the isotope of interest, in this case Pb, and the neutron energy within the system. Compared to other isotopes of interest for nuclear applications, there are few benchmark evaluations for Pb systems. This has caused the latest nuclear cross-section libraries to over/underestimate changes in the neutron population compared to experimental results. Therefore, this evaluation fills an important knowledge gap in benchmark evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Bayesian Optimization Framework for Imperfect Data or Models

Conventional Bayesian optimization methods implicitly assume that the data and model being optimized are “perfect.” This assumption leads to inaccurate posterior probability distribution functions (PDFs) when applied to “imperfect” data or models. The new Bayesian optimization framework presented in this report provides a way to parameterize the effect of imperfections usually encountered in a prior PDF of generalized data or a model on the posterior PDF. The effects of imperfections are parameterized by a set of constraints imposed on the posterior expectation values of deviations between the data and the model and on their covariance matrix elements. A particular set of values for these constraints conveys an evaluator’s best estimate of the effect of imperfections on the corresponding posterior expectation values. When a prior PDF of generalized data is assumed to be normal, an expression for a posterior PDF satisfying an arbitrary set of constraints is derived analytically for linear models. An analogous iterative algorithm is given for nonlinear models. The corresponding posterior PDF should be used to estimate any posterior expectation values in the presence of imperfections parameterized by that set of constraints. A posterior PDF of a conventional Bayesian optimization method is recovered analytically when all evaluator-specified constraints are set to zero (i.e., in the absence of any imperfections). The analytical expressions derived in this report for normal PDFs and linear models were verified numerically by a Metropolis–Hastings Monte Carlo method. The methods presented herein could be applied to any kind of data or models, including differential cross-section data or integral benchmark experiments.

97 MATHEMATICS AND COMPUTING↗